Precision Air Conditioner For Critical Application

Similar documents
AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Chilled Water Precision Air Conditioner for Critical Application

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

AIRSYS-P-SC-MOBILECOOL-OUTDOOR-E1509V01.5 MOBILECOOL-OUTDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.5kW-13.

AIRSYS-P-SC-TELECOOL-E1511V01.3 TELECOOL. Cabinet Cooling Unit. Cooling Capacity:500W-3000W

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

NEXT DL NEXT DL. rcgroupairconditioning

next DX.U.S* 052.Z2.H6.DC

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

next p dw next p dw rcgroupairconditioning

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

Vertical self-contained air conditioner

Precision Cooling. DataMate3000 Series Precision Cooling Systems for Small Equipment Room IT Application

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Aquaflair TRAC-TRAF-TRAH

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

kw COOLING kw HEATING

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

DC Inverter Smart VRF Products(R410A)

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

unico pf unico pf rcgroupairconditioning

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

E U R O V E N T CERTIFIED PERFORMANCE

8-101kW. AlphaCool close control range ADDITIONAL CAPACITIES. NOW AVAILABLE Plus EC fan option kW. Typical applications

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

2013 Product Range Precision Air Conditioners (CRAC)

Component Replacement Guidelines. For AIRSYS Wall Packaged Units. Models

GHE Dehumidifiers for radiant cooling systems with heat recovery

GP SERIES Packaged Chillers

Guide Specifications for InRow Direct Expansion

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Flexible & Innovative. Cooling Solutions

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

Liebert HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control

Refrigerant Type Heat Recovery Unit for Temperature & Humidity Control Room

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

Air Cooled Scroll Chiller

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Screw Water Cooled Chiller SCW210

20-120RT Multi-functional Modular Combination High Efficiency & Energy Saving Keeping Technology Cool

next evo cw next evo cw rcgroupairconditioning

OACS Outdoor Air-Cooled Central Chillers

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

pyxis u pyxis ua NEW rcgroupairconditioning

Concealed Ducted Split Series R-407C MBH

pyxis pyxisa NEW rcgroupairconditioning

Product Brochure Smart Power. Low Profile Ducted

YORK Close Control units

ClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n

Modular Air-cooled Chillers

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N

AIR COOLED CONDENSERS

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

Modular Air Cooled Scroll Chillers

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

gforce Units Data Aire and Data Temp Series

g in n io it d n Co AirnioisCe prmo roretupm Co made in italy

Precision air-handling cabinets. CIATRONIC System Ultimate precision air-conditioning NA C

E U R O V E N T CERTIFIED PERFORMANCE

C+ %RH R22. CUH Series Cooling capacity range kw. Ceiling Concealled Type Air Conditioner For Precision Temperature & Humidity Controls

Compact Ultra Low Temperature Chamber

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Flexible and efficient: Close Climate Control for IT equipment

Liebert HIROSS for Telecom

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

21,8 222 kw COOLING 25,2 236 kw HEATING

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY

The Energy Solutions of Withair Full DC Inverter Ducted Split Air conditioning Catalogue 2017 Take Control of Your Energy Future!

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Air-cooled modular Chiller. Nick Technical Engineer

SCA 620C AIR COOLED SCREW CHILLER

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

System Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons. High Density Presicion Cooling. Kompact.

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Troubleshooting the Indoor AHU as a Standard Product

Evaporadoras Hidrónicas

Precision air handling cabinets Ciatronic MICRO/EXPAIR

Transcription:

AIRSYS-P-SC-DATACOOL-E1312V01.3 Precision Air Conditioner For Critical Application Cooling Capacity: 5.8~30.2kW

DATACOOL product series is one of many data center cooling product family members that AIRSYS offers. It is specially designed for data center cooling application. It incorporates various cutting edge-features. DATACOOL series provides precise humidity, temperature control which is typical of medium/small data centers. The series is designed to work for wide range of -45 ~45 and 24x7 operations. The products meet or exceed high efficiency, high reliability requirement typically seen in the marketplace. Unit Identification DATACOOL. O U DL TP. DXA 5 7... E1 C0 C1 C2 C3 R407. 380/3/50. XXX Separator Character. Power source: Voltage/Phase/Frequent Default=380/3/50(canbe omitted) Separator Character. Refrigerant R407=R407c (Can be omitted) Cabinet Size Code There are 4 types Cabinets: C0,C1,C2,C3 Code For Custom Design 3 alphabetic and numerical code Compressor Type And Number E1: 1 hermetic scroll compressor per unit Nominal Cooling Capacity:kW Cooling Scheme DXA:Direct expansion with air cooled condenser Separator Character. Air Supply Scheme O: Up-front throw U: Bottom throw DL:Replacement,down-front throw TP: Top throw, down-front return(only available for C2,C3 cabinets) Separator Character. Product Series DATACOOL: DATACOOLseries precision air conditioners for small/medium data center, abbr. as DATA. Example: DATACOOL.O.DXA15E1C2. This product name suggests that it is a DATACOOL series, up-front throw air flow, direct evaporative air-cooled with a remote air-cool condenser, nominal cooling capacity of 15KW. This unit has only 1 compressor with cabinet size of C2,charged R407c refrigerant. 02

Operation Range and Control Accuracy Operating Range Ambient Temperature -15 ~+45 ; it can operate in as low as -40 when equipped with low-ambient enhancement option Refrigeration tubing horizontal length: The combined gas and liquid length in horizontal no more than 30 meters. (Please consult with the factory or dealer if range is over the limit.) Refrigeration tubing vertical differences Outdoor unit above the indoor unit: 20 meters Outdoor unit below the indoor unit: 5 meters (Please consult with the factory or dealer if range is over the limit.) Control Precision Temperaturerange:15~35 ; Precision:±1 ; Relative Humidity range: 35%~80%,precision:±5% Application ICT applications Small/Medium MCS Call centers or text message process centers Micro-wave or satellite base stations Mobile telecom-equipment room Small/Medium data centers or computer rooms Network operation centers PUS and battery housing Hot spots or regions within large data centers CT and MRI computer/electronic rooms Medical clinic facilities Industry production or processing plants Precision control environment or labs Standard or calibration chambers Precision machine shops Museum and records keeping environment System Schematic Indoor Outdoor Compressor Return air Supply air Supply fan Evaporator Condenser Condenser fan Sight glass Drier&Filter Expansion valve Liquid reciver 03

Product Features High Efficiency DATACOOL product series was designed with high energy efficiency in mind. The product adopts highefficiency components (such as compressors and fan motors) and efficient structure design to achieve system EER above 2.9. Energy-efficient Running Modes This product series offers two running modes: standard and energy-saving mode. When application requires very accurate Temperature or HR control accuracy, standard mode can be chosen; otherwise energy-saving mode is chosen and can deliver 10% or energy saving. Condenser Fan Speed Control Controlling the condenser fan speed will not only reduce the fan motor s energy but also the whole refrigeration systems. Efficient Air Distribution DATACOOL series offers 4 flow patterns: (up-front throw,bottom throw, replacement and top throw). Clients can pick the most suitable to match their data centers. Up-front throw (return at the lower) mode does not raised floor, is the least demanding installation, and widely accepted in small electronic housing; since hot air tends to go and stay at top and cold stays at bottom, this mode delivers worse energy efficiency comparing with the other 2 modes by 2~5%. See charts below. Bottom throw requires raised-up floor. Comparing withup-front throw, it offers easy air distribution of hot passage and cold isle. This distribution results higher energy saving benefits, also higher infrastructure cost. See charts below. Replacement flow allows air temperature and distribution close to its natural tendency as shown below. It reduces cooling capacity loss as hot cold air mix and doesn t require raised-up floor. It usually delivers better energy saving results. Don t put any obstacles in front of the supply ducts otherwise air short circuit may occur. Top throw standard static pressure at the outlet is 50 Pa, it usually apply to the site that need connect air duct, to achieve better temperature distribution and more flexible unit placement. Filter DATACOOL series uses washable synthetic fiber filters with G4 rating, i.e. it can filter out 80% of 5μ large particles, 20% of 1μ, should meet conventional data center requirements. Styles DATACOOL series main body frames and base are typically in black, follow mainstream industry standards in terms dimensions and styles. It offers compact structures, small foot-print, light weight and easy of moving and handling within confined spaces. Reliability DATACOOL series uses only top quality parts and best brands for its compressors, fan motors, expansion valves, controllers to ensure system high availability and reliability. Unit Systems are designed three levels of access control to reduce risks by human errors or workmanship. Units are also configured with various protection and alarm systems to reduce down-time, such high/low pressure, compressor over-heat, humidifier, heaterover current, fan motor over-drive, high- & low-temp protections and filter clogging etc. heat load=0.5kw/m 2 heat load=0.5kw/m 2 heat load=0.5kw/m 2 Temperature profile of the room Over flow Under flow Displacement flow Temperature 33/91 29/84 24/75 20/68 15/59 Temperature 35/95 30/86 25/77 20/68 15/59 Temperature 34/93 30/86 25/77 20/68 15/59 04

Product Configurations Standard Configuration Steel frames, base & top power-painted in black Steel front panel, heat and sound plates Scroll compressor Backward curve, centrifugal fan with 3 phase AC powered electronic commuted motor Copper tube aluminum finned evaporator Thermal expansion valve Sight glass Dry filter Liquid receiver Electrode humidifier, available with multi-stage humidifier Stainless steel fin electrical heater, available with multiple capacities G4 air filter Return air and HR sensor Options Backward curve, centrifugal fan with 3Phase, EC powered motor 407C refrigeration type Unit Low-Ambient Startup kit for -20 or lower Filter clogging alarm Supply air temperature sensor Supply air pressure sensor Install stands with adjustable legs Floor water sensor/alarm kit R232 com card RS485 com card Pcoweb card Clock card Com protocol converter Pressure switch/protection Micro-controllersystem Phase protection (only application for 3-phase Unit) Continuous control system for condensing pressure Micro PC control system Electrical Panel for Compressor, fan motor, heater, humidifier Circuitry Compressor, fan motor, heater, humidifier etc. connectors Transformer(s) for auxiliary circuitry and microcontroller Note:Above configurations is only available for C1~C3 cabinets Heater/Humidifier Configuration Table Heater capacity (kw) Humidifier capacity (kg/h) 5E1C0 7E1C0 13E1C0 7E1C1 10E1C1 13E1C1 15E1C2 18E1C2 22E1C3 25E1C3 30E1C3 2.3 4.5 6 9 12 13.5 3 5 8 10 13 15 Note: standard configuration, option available, no option available. 05

Remote Control And Monitoring Network The unit can be remote controlled or monitored by many kinds of methods as follows: 3 kinds of local direct cable connection 3 kinds of LAN network connection 4 kinds of wireless network connection Wireless connection types Local area network connection type Wireless connection 1 wireless router wireless communication network LAN connection 1 Cooling unit & Comm. card N1 RS485 card MODBUS protocol RS485-TCP/IP converter with 16 ports Ethernet network cable RS485 Bus N2 Wireless connection 2 Wireless router Wireless connection 3 Mobile phone GSM Mobile communication network GSM module The computer is installed with TCP/IP cardrs485 card RS232 card and IntelliVision plus software N16 N1 Wireless connection 4 LAN connection 2 Mobile phone GSM module RS485 Bus N2 GSM communication network Monitoring Computer N16 Single unit direct connection types Direct connection 1 Units direct connection type Direct connection 2 RS485-RS232 Converter RS485-RS232 Converter N1 RS232 cable RS485 Bus N2 Direct connection 3 Single port RS485-TCP/IP converter Direct connection 4 N16 06

Technical Parameters Indoor Units Unit Model 5E1C0 7E1C0 13E1C0 7E1C1 10E1C1 13E1C1 15E1C2 18E1C2 22E1C3 25E1C3 30E1C3 Supply air scheme(1) O O/U/DL/TP Cooling capacity Total (2) kw 5.8 7.4 13.2 7.6 10.7 13.6 15.4 18.3 22.2 25.4 30.2 Sensible (2) kw 5.2 6.6 11.7 6.9 9.8 12.5 14.2 16.8 20.4 23.4 27.8 Total (3) kw 6.1 7.6 13.4 8.1 11.5 14.2 16.0 18.7 22.6 25.9 30.6 Sensible (3) kw 5.5 6.8 12.1 7.8 10.8 13.3 15.0 17.4 21.0 24.1 28.5 Compressor Type Rotor Hermetic scroll Power input kw 1.6 1.9 3.6 1.9 2.7 3.5 3.7 4.6 5.2 5.9 6.9 Current A 7.2 3.6 6.1 3.4 4.9 5.6 6.5 8.0 9.7 11.2 12.7 Power input kw 1.7 2.0 3.7 1.9 2.9 3.6 3.8 4.8 5.3 6.0 7.1 Current A 7.4 3.8 6.3 3.5 5.1 5.7 6.7 8.2 9.9 11.5 12.9 Fan Qty. of fan n. 1 1 1 1 1 1 1 1 2 2 2 Air volume m 3 /h 1650 1650 2630 2450 2450 2950 3450 3450 5100 6500 6500 External Static pressure(esp) Pa 0 0 0 30 30 30 30 30 50 50 50 Power input kw 0.35 0.35 0.6 0.4 0.4 0.5 0.5 0.5 0.8 1.2 1.2 Current A 1.7 1.7 2.7 0.6 0.6 0.9 0.9 0.9 1.3 2.1 2.1 Heater (4) Type Finned stainless tube Heating capacity kw 2.3 2.3 4.5 2.3 4.5 4.5 6.0 6.0 9.0 9.0 9.0 Working steps n. 1 1 1 1 1 1 2 2 2 2 2 Humidifier (4) Type Electrode Capacity kg/h 3 3 3 3 3 3 5 5 5 8 8 Power input kw 2.3 2.3 2.3 2.3 2.3 2.3 3.8 3.8 3.8 6.0 6.0 OD Model*Qty (5) CMD3x1 CMD4 1 CMD5 1 CMD4 1 CMD4 1 CMD5 1 CME5 1 CME8 1 CME8 1 CME10 1 CME10 1 Power supply Power source 380V/3Ph/50Hz Unit max. operating power input (6) kw 4.9 5.0 9.7 5.3 8.5 9.7 11.8 12.9 16.9 18.2 19.5 Unit max. operating current input (6) A 15.6 10.5 18.0 9.8 15.0 16.4 21.1 23.0 30.0 32.7 34.6 Unit piping connection Condensing water drainage in 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Humidifier water supply in 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 Ref. connecting type Bell mouth thread connection Welding connection Refrigerant gas in 5/8 5/8 5/8 5/8 5/8 5/8 3/4 3/4 3/4 7/8 7/8 Refrigerant liquid in 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 5/8 5/8 Unit external dimensions and Weight Length mm 650 650 650 650 650 650 900 900 1300 1300 1300 Width mm 580 580 580 650 650 650 750 750 750 750 750 Height mm 1910 1910 1910 1910 1910 1910 1910 1910 1910 1910 1910 Weight kg 120 135 155 142 165 180 255 290 370 460 490 Note: (1) O: up-front throw (supplier coming out of up-front louver); D: Bottom Throw; DL: Replacement;TP: top throw, only available for C2, C3 cabinets; (2) Return Air temperature dry bulb 24,humidity at 50%,outdoor dry bulb temperature 35 ; (3) Return Air temperature dry bulb 28,humidity at 40%,outdoor dry bulb temperature 35 ; (4) In this table, only showing the default heater/humidifier default capacities; please refer to Heater/humidifier Configuration Table for other options available for each model if you wish; (5) More detailed parameters can be found in air-cooled condenser catalogue. CMD condenser only offers vertical installation; (6) Max operating power and current: parameters are derived for in the extreme condition when ambient temperature at 45 and unit s electrical heater running at its full capacity to de-humidify. 07

Outdoor Unit Unit Model CMD3 CMD4 CMD5 CME5 CME8 CME10 Capacity kw 9.3 13.7 20.4 20.5 29.6 35.4 Qty. of fan n 1 1 1 1 1 1 Air volume m 3 /h 4400 4100 5600 5600 10100 9700 Power input kw 0.28 0.28 0.37 0.37 0.63 0.63 Current input A 1.3 1.3 1.7 1.7 3.0 3.0 Unit piping connection Refrigerant gas in/mm 5/8" 5/8" 5/8" 19 22 22 Refrigerant liquid in/mm 1/2" 1/2" 1/2" 12 16 16 Unit external dimensions and Weight dimensions Length mm 808 808 1004 1140 1340 1340 Width mm 509 509 509 475 620 620 Height mm 789 789 930 770 1070 1070 Weight kg 29 35 43 47 95 110 (1) Industrial standard operating condition: inlet temperature=35, condenser temperature= 50. Unit Dimensions C0 Up-front throw (air) unit dimensions 08

Unit Dimensions C1 Up-front throw (air) unit dimensions 6 1 2 2 3 4 5 650 1910 650 C1 Bottom throw (air) unit dimensions 09

C1 Replacement (air) unit dimensions C2 Up-front throw (air) unit dimensions 10

C2 Bottom throw (air) unit dimensions C2 Replacement (air) unit dimensions 11

C2 Top throw (air) unit dimensions C3 Up-front throw (air) unit dimensions 12

C3 Bottom throw (air) unit dimensions C3 Replacement (air) unit dimensions 13

C3 Top throw (air) unit dimensions CMD4 dimensions 1 Gas pipe 2 Liquid pipe 3 Cable holes 14

CMD5 dimensions 1 Gas pipe 2 Liquid pipe 3 Cable holes CME8 / CME10 dimensions 15

AIRSYS is a cooling product and solution provider for ICT (Information & Communication Technology) industry. The products include: Air conditioner and Chiller for IT room and large data center Intelligent Control system (BAS) for IT room and data center Air conditioning equipments for telecom shelters Intelligent control system for shelter cooling. Air conditioner and heat exchanger for telecom cabinets. The solution include: Cooling system design System integration Installation and Commissioning Operation and Maintenance AIRSYS is also a global leader in providing cooling solution for Medical Imaging System. AIRSYS Refrigeration Engineering Technology (Beijing) Co. Ltd. Add: No.28, LuGuDong Str., Shijingshan District, Beijing, China Post code: 100040 Tel:+86-10-6865 6161 Fax:+86-10-6865 2453 Callcenter :+86-400-820-5515 www.air-sys.com 16