DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

Similar documents
MERIT SERIES Downflow

MERIT SERIES Upflow / Horizontal

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

MERIT SERIES Downflow

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

ELITE SERIES Downflow - High Efficiency Blower Motor

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

MERIT SERIES Downflow

ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

8+* Bulletin No November 1997

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

ML 1 93 UH 070 x P 36 B

MERIT SERIES Upflow / Horizontal

ML 1 80 UH 070 X E 36 B

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

MERIT SERIES Upflow / Horizontal

MERIT SERIES Up Flow / Horizontal

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

13 GEP A L P - 1 A

AFUE 95% Heating Input 50,000 to 200,000 Btuh

MERIT SERIES Upflow / Horizontal

ELITE SERIES Upflow / Horizontal - Two-Stage Heat

RGE 13 A T - 1 A

AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

GSR21Q PULSE21 SERIES

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17.

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

CB X 32 mv

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

G34M Bulletin #69/ August 2003

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

EL195UH WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. EL195UH SERIES UNITS

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Heavy Duty Transformer. Low Voltage Circuit Breaker. Visit us at For the latest technical information,

TECHNICAL SPECIFICATIONS

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

FG7T (C and L Series)

G32V. Service Literature G32V SERIES UNITS

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

MERIT Series R-410A - Upflow / Horizontal

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

G41UF WARNING. Service Literature G41UF SERIES UNITS. Table of Contents

GHR32Q/V SERIES UNITS

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

TECHNICAL SPECIFICATIONS

Wt. Lbs Model Number (BTUH) Hz

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

RG7D 1-Stage Heat Series

TSTAT0201CW Recommended (sold separately)

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

ELITE Series Variable Capacity

TSTAT0101SC Recommended (order separately)

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

Cooling Capacity CFM in. w.c. (125 Pa)

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

TECHNICAL SPECIFICATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

G6RC Series TECHNICAL SPECIFICATIONS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

MERIT Series R-410A - Upflow / Horizontal

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Transcription:

PRODUCT SPECIFICATIONS GAS FURNACES SLP98UHV DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower Bulletin No. 20577 March 208 Supersedes February 208 MODEL NUMBER IDENTIFICATION AFUE - Up To 98.7% Input - 66,000 to 32,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons Unit Type SL = Dave Lennox Signature Collection Stages P = Precise Comfort Technology SL P 98 UH 070 x V 36 B Cabinet Width B = 7-/2 in. C = 2 in. D = 24-/2 in. AFUE 98 = 98% Configuration UH = Upflow/Horizontal Nominal Gas Heat Input 070 = 66,000 Btuh 090 = 88,000 Btuh 0 = 0,000 Btuh 35 = 32,000 Btuh Nominal Add-On Cooling Capacity 36 = 2-3.5 tons 48 = 4 tons 60 = 4-5 tons Blower V = Variable Speed Blower Motor NO x X = Units meet California Nitrogen Oxides Standard (40ng/J) Indoor coils with the same letter designation will physically match the furnace.

FEATURES CONTENTS L Blower Data... 2 Dimensions - Furnace/Coil Combined Dimensions... 7 Dimensions - Horizontal Position... 5 Dimensions - Upflow Position... 4 Features... 2 Gas Heat Accessories... C E B D G F Installation Clearances... 9 M H Model Number Identification... I Optional Accessories - Order Separately... Optional Accessory Dimensions... 6 Specifications... 0 J Vent Lengths... 3 WARRANTY Duralok Plus Aluminized Steel Heat Exchanger Limited lifetime warranty in residential applications (twenty year transferable), ten years in non-residential applications. All Other Covered Components - Limited ten year warranty in residential applications, one year in nonresidential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. APPROVALS Units are certified by AHRI. Units tested and rated according to US DOE test procedures and FTC labeling regulations. Blower data from unit tests conducted in Lennox Laboratory air test chamber. Approved by the California Energy Commission and meets California Nitrogen Oxides Standard (NOx) limits of 40 ng/j. Energy Star certified units are designed to use less energy, help save money on utility bills, and help protect the environment. ISO 900 Registered Manufacturing Quality System. APPLICATIONS Input capacities of 66,000, 88,000, 0,000 and 32,000 Btuh. Variable heat capacity in increments as small as % or as large as needed within minimum/maximum input range. Energy efficiency up to (AFUE) 98.7%. Compact cabinet for upflow, horizontal-right or horizontal-left applications without any internal modifications to the unit. Variable speed blower ideal for zoning applications. Lennox add-on indoor coils, high-efficiency air cleaners and humidifiers can easily be added to furnace. Shipped factory assembled with controls installed and wired. SLP98UHV / Page 2 K A Each unit factory test operated to ensure proper operation. NOTE - FURNACES CANNOT BE TWINNED! Zoning Applications The SLP98UHV furnace is designed to work with the Lennox iharmony Zoning System with the icomfort Communicating Thermostat. The iharmony Zoning System provides direct feedback to the SLP98UHV, controlling both airflow and heat output to precisely match the comfort requirements for up to four zones. HEATING SYSTEM B SilentComfort Technology Patented burner sound enclosure and extra cabinet insulation reduces operating sound levels. C Lennox Duralok Plus Heat Exchanger Assembly Lennox developed heat exchanger assembly consists of primary heat exchanger and secondary condenser coil assembly. Main multi-pass crimped seam design clamshell type heat exchanger. Constructed of heavygauge, aluminized steel. Designed for normal expansion and contraction with maximum efficiency and minimum resistance to air flow. D Secondary heat exchanger condenser coil constructed of aluminum fins fitted to stainless steel tubes. Coil is factory tested for leaks. Condensate drain header box assembly located on front of coil.

E F FEATURES HEATING SYSTEM (continued) Compact size of complete heat exchanger assembly permits low overall design of furnace cabinet. Heat exchanger assembly has been laboratory life cycle tested in excess of industry standards. Lennox Designed Header Box Header box on end of condenser coil collects flue condensate for disposal through condensate drains. The drains are located on each side of the cabinet for easy field installation of condensate drain trap. Only one drain is used, the other drain is sealed. Condensate drain trap is included with the unit for field installation. Lennox Designed Flue Condensate Trap Assembly Condensate trap assembly is mounted outside the conditioned air stream. Assembly can be mounted on either side of cabinet in upflow applications. Assembly is mounted below the cabinet in horizontal applications. See Dimension Drawing and Installation Instructions. Can also be mounted remotely (up to 5 ft. away) from unit. 90 street elbow furnished for ease of drain trap installation. Drain connection can be made with field provided PVC pipe or PVC coupling. Drain cap on trap allows easy cleaning and winterizing. Inshot Burners Aluminized steel inshot burners provide efficient, trouble-free operation. Burner venturi mixes air and gas in correct proportion for proper combustion. Burner assembly is removable from the unit as a single component for ease of service. Variable Capacity Gas Control Valve Variable capacity gas control valve adjusts capacity output in increments as small as % or as large as needed. 24 volt redundant combination valve combines manual shut off switch (On-Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control. G H Variable Speed Combustion Air Inducer Three-phase variable speed inducer motor is controlled by the SureLight Control. Overload protected (auto-reset). Heavy-duty blower prepurges heat exchanger and safely vents flue products. Operates only during heating cycle. Pressure Switches (Two-Stage) Prove Combustion Air Inducer operation before allowing gas valve to open. Limit Control Automatic reset, primary limit is accurately located on vestibule panel on all units. Optional Accessories Altitude Pressure Switch Kit Required for proper unit operation on installations above 7500 ft. Natural Gas to LPG/Propane Conversion Kit Required for field changeover from natural gas to LPG/ Propane. Includes gas valve and orifices. LPG/Propane to Natural Gas Conversion Kit Required for field changeover from LPG/Propane to natural gas. Muffler (US Only) Significantly reduces outdoor operating sound levels. Two-inch diameter muffler is optional for 070 through 0 input models. NOTE - Two-inch muffler is optional for the 0 input model with a maximum vent pipe length of up to 29 ft. Three-inch diameter muffler is optional for 0 and 35 input models. NOTE - Three-inch muffler is optional for the 0 input model with a minimum vent pipe length of 30 ft. Installed vertically in the exhaust piping. See Optional Accessory Dimension Drawing. Flame Rollout Switch Manual reset switches are factory installed on burner box. Switch provides protection from abnormal operating conditions. SureLight Hot Surface Ignitor Tough, reliable, long-life, trouble-free performance. Silicon nitride ignitor. Cemented to steatite block for protection against current leakage. Ignition leads are constructed of nickel plated copper and are enclosed in high temperature Teflon insulation for dependable operation. SLP98UHV / Page 3

FEATURES DIRECT VENT SEALED COMBUSTION SYSTEM Furnace features a sealed combustion system and can only be installed in Direct Vent (two pipe) applications. In Direct Vent applications, combustion air is supplied from outdoors and flue gases are discharged outdoors. NOTE - Lennox has approved the use of DuraVent PolyPro and Centrotherm InnoFlue manufactured vent pipe and terminations as an alternative to PVC vent pipe. Must be ordered separately. Tested and listed to the ULC S636 standard in Canada. The polypropylene venting system must follow the uninsulated and unconditioned space vent lengths listed in the table on Page 4. Refer to the Installation Instructions for additional details. Optional Accessories Termination Kits Facilitates installation of combustion air intake pipe and flue exhaust pipe. Refer to venting table in this bulletin to determine pipe size needed and proper termination kit required. See Optional Accessories table and dimension drawings. Termination Kit - Concentric 2 or 3 inch kit contains concentric termination assembly, reducer bushing and 45 elbow. 2 inch kit for -070 model contains an outdoor exhaust accelerator. Kit requires single hole penetration of roof or wall for installation. Roof Termination Flashing Kit is available for use with 2 inch Kits. CSA certified. Termination Kit - Flush-Mount Kit contains flush-mount termination, accelerator, mounting template and hardware. Kit may be used with 2, 2-/2 or 3 in. pipe. Termination Kits - Wall Assembly Close Couple (US Only) 2 or 3 inch kit consists of close-couple, side-by-side PVC piping with galvanized steel wall cover plate for sealing and isolating piping penetration of the wall. Piping spacing and length is sized for proper wall installations. CSA certified. Close Couple WTK (Canada Only) 2 or 3 inch kit contains one insulated faceplate, one insulated exhaust pipe, elbow and fittings. I J Wall Ring 2 inch kit contains 2 stainless steel outside seal caps, 2 galvanized steel inside seal caps, 4 seal rings for the caps and 8 inch insulation sleeve for sealing and isolating intake and exhaust piping penetration of wall. Maintain a maximum of 6 inches between the inlet and outlet openings in the installation of the pipes. Roof Termination Flashing Kit 3 inch kit contains two neoprene rubber roof flashings for vertical venting through a roof. Vent pipe and insulation not furnished. Flashing Kit can also be used with 2 inch Concentric Vent Termination Kits used in vertical venting rooftop applications. BLOWER Variable Speed Direct Drive Blower Each blower assembly statically and dynamically balanced. Change in blower speeds is easily accomplished by simple DIP switch changes on the SureLight control. See Blower Performance tables. Blower assembly easily removed for servicing. Variable Speed Blower Motor Variable speed motor maintains specified air volume from 0 though 0.8 in. w.g. (heating) and 0 through.0 in. w.g. (Cooling) static range. Variable speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Motor is controlled by the SureLight Control. Motor is equipped with ball bearings and is resiliently mounted. When furnaces are used with the iharmony Zoning System and the icomfort Communicating Thermostat, the blower motor operates from predetermined minimum - maximum air volumes to satisfy zone requirements. SLP98UHV / Page 4

K FEATURES CONTROLS SureLight Control (icomfort Communicating) Advanced control communicates information about various operating parameters in the furnace to the optional icomfort Communicating Thermostat to constantly maintain the highest level of comfort, performance and efficiency available. Auto Configuration - On start-up the control automatically sends a description of the unit to the optional icomfort Communicating Thermostat to automatically configure the number of stages and features available. Connections for connecting a conventional heating/ cooling thermostat are also provided on the control. Control also features: Innovative AirFlex technology allows custom blower settings based on the application. Precise Comfort Technology automatically adjusts blower speed and heat input in increments as small as % or as large as needed for greater temperature control. Variable-speed combustion air inducer is controlled by the Surelight Control. Prior to ignition, a pre-purge cycle for 5 seconds is initiated. After the main burners are turned off, a post-purge cycle for 20 seconds is run. Thermostat Control - Designed to operate in a variable capacity mode. The unit will automatically adjust firing rate based on demand and changing conditions. For optimal performance, the use of a high-quality, digital two-stage thermostat with adjustable settings for first stage/second stage, on/off differentials and adjustable stage timers is recommended. Furnace Input Staging Options Thermostat Type icomfort Communicating Thermos t at Two-Stage (Conventional) Single-Stage (Conventional) Input Staging Available Variable Capacity (increments as small as %) Four Stage (35, 60, 80, 00%) Variable Capacity (increments as small as %) Two-stage (70% and 00%) Three-Stage (35%, 70% and 00%) SureLight Ignition Control - Ignition control continuously monitors line voltage and maintains the igniter power at a constant level to provide consistent lighting and maximum igniter life. Safety Controls - Flame sensor utilizes flame rectification for safe and reliable operation. Should flame fail to ignite, control will initiate 4 reattempts at ignition before locking out unit operation for 60 minutes. Watchguard type circuit automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. Display LED - Seven segment LED displays alphanumeric information related to diagnostics as well as system operation and status. Diagnostic codes are held in non-volatile memory, immune from power interruptions. Holds up to ten diagnostic codes in order of occurrence for recall on demand. Port on blower door allows for easy viewing. DIP Switch Settings (Note - DIP switches settings are not used with icomfort Communicating Thermostat) Select Thermostat used - Single-Stage or Two-Stage. Select Operation Mode - Two-Stage, Three-Stage or Variable Capacity. Two selectable second stage recognition times (7 and 2 minutes) are available on the control when the furnace is used with a single-stage thermostat. When used with a two-stage thermostat, furnace will only initiate second stage operation with a second stage thermostat demand. Heating Speeds - A combination of DIP swtich settings allow Normal, 7.5% increase, 5% increase, 7.5% decrease or 5% decrease motor speed selection within heating speed selected for fine tuning air volume. See Blower Performance tables. Cooling Speeds - A combination of DIP switch settings allow Normal, 0% increase or 0% decrease motor speed selection within cooling speed selected for fine tuning air volume. See Blower Performance tables. Blower Speed Ramping (Cooling Mode) - DIP switch settings allow one of four blower speed profiles during cooling operation. Profile A (factory setting) - Motor runs at 50% for 30 seconds, then at 82% for 7-/2 minutes, then at 00% (if needed) until demand is satisfied. Once demand is met, motor runs at 50% for 30 seconds, then ramps down to stop. Profile B - Motor runs at 82% for 7-/2 minutes and then at 00% (if needed) until demand is satisfied. Once demand is met,motor ramps down to stop. Profile C - Motor runs at 00% until demand is satisfied. Once demand is met, motor runs at 00% for 60 seconds, then ramps down to stop. Profile D - Motor runs at 00% until demand is satisfied. Once demand is met, motor ramps down to stop. SLP98UHV / Page 5

FEATURES CONTROLS (continued) Dehumidification (Active or Humiditrol Option) - A jumper on the control control must be clipped to enable active dehumidification and/or operation with a Humiditrol Whole-Home Dehumidification System. A humidity controlling thermostat or device is also required. During a call for cooling, air volume is automatically reduced, forcing humidity removal by the air conditioner or heat pump system. After the humidity has reached the desired set-point the cooling air volume returns to its designed rate. A dehumidification signal from the thermostat reduces the cooling cfm to 70% of the requested cooling cfm. Dual-Fuel Operation - A jumper on the control must be clipped to enable operation with a single or two-stage heat pump. The indoor blower is started without delay when a call for heat is received. Two-Stage Compressor Operation - A jumper on the control must be clipped to enable operation with a two-stage compressor. The cooling blower speeds for first and second stage cooling will be dictated by the applicable DIP switch settings. Lennox System Operations Monitor Connection - Monitors outdoor unit operation (communicating mode). Blower On Time (Heating) - Blower on time is fixed at 30 seconds, blower off time is adjustable from 60, 90, 20 and 80 seconds (factory setting - 90 seconds). Blower Off Time (Cooling) - For air-conditioning applications, blower on time is 2 seconds following thermostat demand for cooling. Blower off delay is 30 seconds at 50% of high cool cfm (factory default). Controls evaporator humidity by controlling blower and compressor speed on two-stage outdoor units when used with icomfort Communicating Thermostat or ComfortSense 7500 thermostat. Continuous Blower Speed - Adjustable continuous blower speed is a percentage of the high cooling speed selection. There are four selectable options (via DIP switch settings) of 28%, 38% (default setting), 70% and 00%. Accessory Terminals - Two accessory terminals furnished for additional power supply requirements for 20 volt (less than amp) power humidifiers and powered air cleaners. One 24 volt humidifier output furnished for non-powered humidifiers. Control is factory installed in the unit control box. 24 Volt Transformer Furnished and factory installed in control box. 40VA transformer has circuit breaker wired in series. Field Wiring Make-up Box Furnished for line voltage wiring. Factory installed internally on left side of furnace. Box may be installed internally or externally on either side of furnace. Optional Accessories icomfort S30 Ultra-Smart Thermostat (part of the icomfort Residential Communicating Control System) The icomfort S30 Thermostat recognizes and connects to all icomfort Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort Communicating products to simplify system setup. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Also displays service alerts and reminders. Dealer Dashboard features online real-time monitoring of installed icomfort Communicating systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Works with Amazon Alexa-enabled products. Easy to read 7 in. high definition color display (measured diagonally). Conventional outdoor units (not icomfort Communicating) can easily be added and controlled by the icomfort S30 Thermostat. Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 8-gauge standard thermostat wiring. Definition Color Display, Mag-Mount, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation. See the icomfort S30 Thermostat Product Specifications bulletin in the Controls section for more information. SLP98UHV / Page 6

FEATURES CONTROLS (continued) Optional Accessories (continued) icomfort Wi-Fi Thermostat (part of the icomfort Residential Communicating Control System) The icomfort Wi-Fi Thermostat recognizes and connects to all icomfort Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort Communicating products to simplify system setup. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Also displays service alerts and reminders. Dealer Dashboard features online real-time monitoring of installed icomfort Communicating systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Easy to read 7-inch color screen (measured diagonally). Conventional outdoor units (not icomfort Communicating) can easily be added and controlled by the icomfort Wi-Fi Thermostat. Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 8-gauge standard thermostat wiring. See the icomfort Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. ComfortSense 7500 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/2 Cool. Auto-changeover. Dual-fuel control with optional outdoor sensor. Controls dehumidification during cooling mode and humidification during heating mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. See the ComfortSense 7500 Product Specifications bulletin in the Controls section for more information. Remote Outdoor Temperature Sensor Used with the icomfort Communicating Thermostats and ComfortSense 7500 thermostat. When installed outdoors, sensor allows thermostat to display outdoor temperature. Sensor is auto-detected when connected to thermostat. NOTE - Sensor is required for Humiditrol applications. NOTE - The outdoor sensor is furnished as standard with icomfort Communicating outdoor units, optional for conventional units. Thermostat Thermostat (icomfort Communicating Thermostat or programmable/non-programmable) is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book for selection. Night Service Kit Contains most commonly used service parts: Furnace control Ignitor Flame sensor Gas valve Transformer Service Manual SLP98UHV / Page 7

FEATURES L M CABINET -profile, narrow width cabinet allows easy installation in upflow or horizontal applications. Heavy-gauge, cold rolled steel construction. Pre-painted cabinet finish. Flanges provided on supply air opening for ease of plenum connection or alignment with indoor coil. Fully insulated cabinet with foil faced insulation on sides and back of heating compartment and sealed mat faced insulation in blower compartment. Sealed blower compartment. Inner blower compartment access panel seals blower compartment from air leakage. Complete service access. Safety interlock switch automatically shuts off power to unit when inner blower compartment access panel is removed. Gas piping and electrical inlets are provided in both sides of cabinet. Return Air Entry: For bottom/end return-air entry, remove furnished bottom seal panel from cabinet. For side return-air entry (upflow applications only), corners are marked on either side of cabinet for return air cut-outs. On furnaces with side return air and condensate trap on the same side of the cabinet, a field fabricated transition or optional Return Air Base is required when using an IAQ product higher than 4-3/6 in. installed next to the unit and serviced from the front. IAQ products higher than 20 in. require a field fabricated transition. See dimension drawings. NOTE - 60C and 60D size units that require air volumes over 800 cfm must have one of the following:. Single side return air and Optional Return Air Base with transition that must accommodate required 20 x 25 x inch air filter to maintain proper velocity. 2. Bottom return air. 3. Return air from both sides. 4. Bottom and one side return air. See Blower Performance Tables for additional information. Coil Match-up All furnaces exactly match Lennox cased upflow indoor coils and horizontal indoor coils with same letter designation (A, B, C, D) in model number. No adaptor required. Engaging holes furnished on cabinet for alignment. Lennox uncased coils match furnaces without any overhang but require an optional adaptor base or field fabricated transition to match furnace opening. See coil bulletin for additional information. Leakage Cabinet All models have less than 2% air leakage and meet ANSI/ASHRAE Standard 93-200 Method of Test for Determining the Air Tightness of HVAC Equipment. Optional Accessories Condensate Drain Heat Cable Kits Self-limiting wattage heat cable prevents condensate drain from freezing in unconditioned areas. Available in 6 or 24 ft. lengths. Crawl Space Vent Drain Kit Allows venting through a crawl space for upflow and horizontal applications. Includes 2 or 3 in. sanitary tee, 2 in. PVC assembly, PVC boot and clamp. Kit for Canada is certified to ULC S636. Horizontal Suspension Kit Provides suspension of unit and indoor coil in horizontal applications. Allows complete service access. Consists of corner mounted hanging brackets with vibration isolators, return air end support rail and hardware for assembly. Metal hanging straps must be field provided. Return Air Base On furnaces with side return air and condensate trap on the same side of the cabinet, a field fabricated transition or Return Air Base is required when using an IAQ product higher than 4-3/6 in. installed next to the unit and serviced from the front. IAQ products higher than 20 in. require a field fabricated transition. Must be used for 60C and 60D models with air volumes over 800 cfm in upflow applications when only one side return is required. Cabinet is shipped flat for easy field assembly and is pre-painted steel to match the furnace. Gasketed for tight seal. See Dimension Drawing. SLP98UHV / Page 8

FEATURES CABINET (continued) Performance Economizer (Commercial Applications Only) Designed for applications requiring outdoor air to be utilized in a commercial HVAC system. Allows the entry of fresh outdoor air for free cooling, reducing the requirement for mechanical cooling. Heavy gauge galvanized steel cabinet lined with thick fiberglass insulation. Mixed air sensor, outdoor air sensor and 24VAC transformer furnished. Approved for California Title 24 building standards. ASHRAE 90.-200 compliant. See separate Product Specifications bulletin for additional information and available control and sensor options. NOTE - Economizer is not icomfort Communicating compatible. Air Filter and Rack Kit for Upflow Side Return Air Applications - Not for use with Return Air Base Washable or vacuum cleanable polyurethane frame type filter and external side return air rack available for field installation. Available in single and ten pack kits. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. Field installs on either side of unit cabinet. See dimension drawing. INDOOR QUALITY See Indoor Air Quality section and Lennox Price Book for a complete list of indoor air quality products (air purification systems, high efficiency air filters and filter cabinets, UV lights, humidifiers, fresh air ventilation system and heat/energy recovery systems). FILTER (not furnished) Filter and provisions for external mounting must be field provided. Optional Accessories Air Filter and Rack Kit for Horizontal Return Air (End) Applications Washable or vacuum cleanable polyurethane frame type filter and external end return air rack available for field installation. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. See dimension drawing. INSTALLATION CLEARANCES Sides Rear Top/Plenum Front Front (service/alcove) Floor 0 inches (0 mm) 0 inches (0 mm) inch (25 mm) 0 inches (0 mm) 24 inches (60 mm) 2 Combustible NOTE - Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ ANSI-Z223.) or the National Standard of Canada CAN/CSA-B49. Natural Gas and Propane Installation Code. NOTE - In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ANSI-Z223.) or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA-B49.. Allow proper clearances to accommodate condensate trap and vent pipe installation. 2 Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring. SLP98UHV / Page 9

SPECIFICATIONS Gas Model No. SLP98UH070XV36B SLP98UH090XV36C SLP98UH090XV48C Heating AHRI Reference No. 47925 47926 47927 Performance AFUE 98.% 98.% 98.2% Maximum Input - Btuh 66,000 88,000 88,000 Output - Btuh 64,000 85,000 85,000 Temperature rise range - F 50-80 60-90 50-80 Gas Manifold Pressure (in. w.g.) 3.5 / 0.0 3.5 / 0.0 3.5 / 0.0 Nat. Gas / LPG/Propane Minimum Input - Btuh 23,000 3,000 3,000 Output - Btuh 22,000 30,000 30,000 Temperature rise range - F 35-65 35-65 35-65 Gas Manifold Pressure (in. w.g.) 0.5 /.5 0.5 /.5 0.5 /.5 Nat. Gas / LPG/Propane static - in. w.g. 0.8 0.8 0.8 Connections in. Indoor Blower SLP98UHV / Page 0 Intake / Exhaust Pipe (PVC) 2 / 2 2 / 2 2 / 2 Gas pipe size IPS /2 /2 /2 Condensate Drain Trap (PVC pipe) - i.d. 3/4 3/4 3/4 with furnished 90 street elbow 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt with field supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT Wheel nominal diameter x width - in. 0 x 9 0 x 9 x Motor output - hp /2 /2 3/4 Tons of add-on cooling 2-3 2-3.5 2.5-4 Air Volume Range - cfm 339-365 520-360 528-770 Electrical Data Voltage (Maximum Amps) 20 volts - 60 hertz - phase Blower motor full load amps 7.7 7.7 0. Maximum overcurrent protection 5 5 5 Shipping Data lbs. - package 38 55 65 NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. SPECIFICATIONS Gas Model No. SLP98UH090XV60C SLP98UH0XV60C SLP98UH35XV60D Heating AHRI Reference No. 47928 47929 479220 Performance AFUE 98.7% 98.% 98.4% Maximum Input - Btuh 88,000 0,000 32,000 Output - Btuh 87,000 06,000 28,000 Temperature rise range - F 50-80 50-80 55-85 Gas Manifold Pressure (in. w.g.) 3.5 / 0.0 3.5 / 0.0 3.5 / 0.0 Nat. Gas / LPG/Propane Minimum Input - Btuh 3,000 39,000 46,000 Output - Btuh 30,000 38,000 45,000 Temperature rise range - F 35-65 35-65 35-65 Gas Manifold Pressure (in. w.g.) 0.5 /.5 0.5 /.5 0.5 /.5 Nat. Gas / LPG/Propane static - in. w.g. 0.8 0.8 0.8 Connections in. Indoor Blower Intake / Exhaust Pipe (PVC) 2 / 2 2 / 2 2 / 2 Gas pipe size IPS /2 /2 /2 Condensate Drain Trap (PVC pipe) - i.d. 3/4 3/4 3/4 with furnished 90 street elbow 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt 3/4 slip x 3/4 Mipt with field supplied (PVC coupling) - o.d. 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT 3/4 slip x 3/4 MPT Wheel nominal diameter x width - in. x x x Motor output - hp Tons of add-on cooling 3-5 3-5 3.5-5 Air Volume Range - cfm 375-295 554-225 634-290 Electrical Data Voltage (Maximum Amps) 20 volts - 60 hertz - phase Blower motor full load amps 2.8 2.8 2.8 Maximum overcurrent protection 20 20 20 Shipping Data lbs. - package 65 75 90 NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces.

OPTIONAL ACCESSORIES - ORDER SEPARATELY NOTE - FURNACES CANNOT BE TWINNED! B Width Models C Width Models D Width Models CABINET ACCESSORIES Horizontal Suspension Kit - Horizontal only 5W0 5W0 5W0 Return Air Base - Upflow only 50W98 50W99 5W00 Performance Economizer (Commercial Only) 0U53 0U53 0U53 CONDENSATE DRAIN KITS Condensate Drain Heat Cable 6 ft. 26K68 26K68 26K68 24 ft. 26K69 26K69 26K69 Crawl Space Vent Drain Kit US 5W8 5W8 5W8 Canada 5Z70 5Z70 5Z70 CONTROLS icomfort S30 Thermostat 2U67 2U67 2U67 icomfort Wi-Fi Thermostat 0F8 0F8 0F8 Remote Outdoor Air Temperature Sensor X2658 X2658 X2658 (for dual fuel and Humiditrol ) 2 Discharge Air Temperature Sensor 88K38 88K38 88K38 ComfortSense 7500 Thermostat 3H4 3H4 3H4 3 Remote Outdoor Air Temperature Sensor (for dual fuel and Humiditrol) X2658 X2658 X2658 FILTER KITS 4 Air Filter and Rack Kit Horizontal (end) Size of filter - in. 87L96-8 x 25 x 87L97-20 x 25 x 87L98-25 x 25 x Side Return Single 44J22 44J22 44J22 Ten Pack 66K63 66K63 66K63 Size of filter - in. 6 x 25 x 6 x 25 x 6 x 25 x NIGHT SERVICE KIT Night Service Kit 0U37 0U37 0U37 TERMINATION KITS Direct Vent Applications Only. See Installation Instructions for specific venting information. Termination Kits Concentric US - 2 in. 7M80 69M29 - - - 3 in. - - - 60L46 60L46 Canada - 2 in. 44W92 44W92 - - - 3 in. - - - 44W93 44W93 Flush-Mount US - 2, 2-/2 or 3 in. 5W 5W 5W Canada - 2, 2-/2 or 3 in. 5W2 5W2 5W2 Wall - Close US - 2 in. 22G44 - - - - - - Couple 3 in. 44J40 44J40 44J40 Wall - Close Canada - 2 in. 30G28 - - - - - - Couple WTK 3 in. 8J20 8J20 8J20 Roof 2 in. 5F75 5F75 - - - Wall Ring Kit 2 in. 5F74 5F74 - - - Roof Termination Flashing Kit (2 flashings) 3 in. 44J4 44J4 44J4 Remote Outdoor Temperature Sensor is used with conventional (non-icomfort Communicating) outdoor units (sensor is furnished with icomfort Communicating outdoor units). Allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol applications. 2 Optional for service diagnostics. 3 Remote Outdoor Temperature Sensor for ComfortSense 7500 Thermostat must be connected directly to the thermostat, Do not connect it to the SureLight control. 4 Cleanable polyurethane frame type filter. NOTE - Termination Kits (44W92, 44W93, 30G28, 5W2, 8J20) and Crawl Space Vent Drain Kit (5Z70) are certified to ULC S636 standard for use in Canada only. GAS HEAT ACCESSORIES Input Altitude Pressure Switch Kit Natural Gas to LPG/Propane Kit LPG/Propane to Natural Gas Kit 750-0,000 ft. 0-7500 ft. 0-7500 ft. Muffler (US Only) 070 4T65 65W77 70W87 5Y66 (2-inch) 090 4T65 65W77 70W87 5Y66 (2-inch) 0 4T65 65W77 70W87 5Y66 (2-inch) 6A56 (3-inch) 35 4T65 65W77 70W87 6A56 (3-inch) Two-inch diameter muffler (5Y66) is optional for 0 input model with a maximum vent pipe length of up to 29 ft. Three-inch diameter muffler (6A56) is optional for 0 input model with a minimum vent pipe length of 30 ft. SLP98UHV / Page

OUTDOOR TERMINATION KIT USAGE Input Size 070 090 0 Vent Pipe Diameter (in.) Flush Mount Kit 5W (US) 4 5W2 (CA) Standard Terminations Wall Kit Wall Ring Kit 2 inch 3 inch 2 inch 22G44 (US) 4 30G28 (CA) 44J40 (US) 4 8J20 (CA) 5F74 Field Fabricated Exhaust Accelerator Size Required Concentric Terminations Concentric Kit -/2 inch 2 inch 3 inch 7M80 (US) 4 44W92 (CA) 69M29 (US) 4 44W92 (CA) 60L46 (US) 4 44W93 (CA) 2 3 YES YES YES YES -/2 in. 2 YES - - - - - - 2-/2 3 YES YES YES YES -/2 in. 2 YES - - - - - - 3 3 YES YES YES YES -/2 in. 2 YES - - - - - - 2 3 YES - - - YES YES 2 in. - - - YES YES 2-/2 3 YES - - - YES YES 2 in. - - - YES YES 3 3 YES - - - YES YES 2 in. - - - YES YES 2 YES - - - YES YES 2 in. - - - YES YES 2-/2 YES - - - YES - - - 2 in. - - - YES YES 3 YES - - - YES - - - 2 in. - - - YES YES 35 3 YES - - - YES - - - 2 in. - - - - - - YES NOTE - Standard Terminations do not include any vent pipe or elbows external to the structure. Any vent pipe or elbows external to the structure must be included in total vent length calculations. See Vent Length Tables. Requires field provided -/2 in. outdoor exhaust accelerator. 2 Concentric Kits 7M80 and 44W92 include -/2 in. outdoor exhaust accelerator, required when used with 045 and 070 input models. Accelerator is not used with 090, 0, 35 input models. 3 Flush Mount Kit 5W and 5W2 includes -/2 in. outdoor exhaust accelerator, required when used with 045, 070 and 090 input models. Accelerator is not used with 0 or 35 input models. 4 Termination Kits 30G28, 44W92, 44W93, 5W2 and 8J20 are certified to ULC S636 standard for use in Canada only. VENT LENGTHS - UNINSULATED EXHAUST PIPE IN UNCONDITIONED SPACE Winter Design Temperatures 32 to 2 F 20 to F 0 to 20 F Vent Pipe Diameter PVC Unit Input Size 070 090 0 35 PolyPro InnoFlue Maximum Un-Insulated Exhaust Vent Length (ft.) PVC PolyPro InnoFlue PVC PolyPro InnoFlue PVC PolyPro InnoFlue 2 in. 9 4 2 8 5 N/A N/A 2-/2 in. 7 N/A 0 N/A 2 N/A N/A N/A 3 in. N/A N/A 6 6 8 8 3 3 2 in. N/A N/A 6 4 8 6 N/A N/A 2-/2 in. N/A N/A N/A N/A N/A N/A N/A N/A 3 in. N/A N/A N/A N/A N/A N/A N/A N/A 2 in. N/A N/A N/A N/A N/A N/A N/A N/A 2-/2 in. N/A N/A N/A N/A N/A N/A N/A N/A 3 in. N/A N/A N/A N/A N/A N/A N/A N/A NOTE - Concentric terminations are equivalent to 5 ft. of straight pipe and should be included when measuring total pipe length. Refer to 99% Minimum Design Temperature table provided in the current edition of ASHRAE Handbook-Fundamentals. PolyPro poly-propylene vent pipe is a registered trademark of DuraVent. Innoflue is a registered trademark of Centrotherm Eco Systems. SLP98UHV / Page 2

VENT LENGTHS - FEET STANDARD TERMINATION AT ELEVATION 0-7500 ft. No. of 90 ELL Pipe Size 2 in. 2-/2 in. 3 in. Input 070 090 0 35 070 090 0 35 070 090 0 35 9 69 4 N/A 40 93 43 N/A 62 43 8 4 2 86 64 9 N/A 35 88 38 N/A 57 38 3 09 3 8 59 N/A N/A 30 83 33 N/A 52 33 08 04 4 76 54 N/A N/A 25 78 28 N/A 47 28 03 99 5 7 49 N/A N/A 20 73 23 N/A 42 23 98 94 6 66 44 N/A N/A 5 68 8 N/A 37 8 93 89 7 6 39 N/A N/A 0 63 3 N/A 32 3 88 84 8 56 34 N/A N/A 05 58 N/A N/A 27 08 83 79 9 5 29 N/A N/A 00 53 N/A N/A 22 03 78 74 0 46 24 N/A N/A 95 48 N/A N/A 7 98 73 69 STANDARD TERMINATION AT ELEVATION 750-0,000 ft. No. of 90 ELL Pipe Size 2 in. 2-/2 in. 3 in. Input 070 090 0 35 070 090 0 35 070 090 0 35 66 44 N/A N/A 5 68 N/A N/A 37 8 93 89 2 6 39 N/A N/A 0 63 N/A N/A 32 3 88 84 3 56 34 N/A N/A 05 58 N/A N/A 27 08 83 79 4 5 29 N/A N/A 00 53 N/A N/A 22 03 78 74 5 46 24 N/A N/A 95 48 N/A N/A 7 98 73 69 6 4 9 N/A N/A 90 43 N/A N/A 2 93 68 64 7 36 4 N/A N/A 85 38 N/A N/A 07 88 63 59 8 3 N/A N/A N/A 80 33 N/A N/A 02 83 58 54 9 26 N/A N/A N/A 75 28 N/A N/A 97 78 53 49 0 2 N/A N/A N/A 70 23 N/A N/A 92 73 48 44 CONCENTRIC TERMINATION ELEVATION 0-7500 ft. No. of 90 ELL Pipe Size 2 in. 2-/2 in. 3 in. Input 070 090 0 35 070 090 0 35 070 090 0 35 83 67 2 N/A 30 89 39 N/A 46 39 4 05 2 78 62 7 N/A 25 84 34 N/A 4 34 09 00 3 73 57 N/A N/A 20 79 29 N/A 36 29 04 95 4 68 52 N/A N/A 5 74 24 N/A 3 24 99 90 5 63 47 N/A N/A 0 69 9 N/A 26 9 94 85 6 58 42 N/A N/A 05 64 4 N/A 2 4 89 80 7 53 37 N/A N/A 00 59 N/A N/A 6 09 84 75 8 48 32 N/A N/A 95 54 N/A N/A 04 79 70 9 43 27 N/A N/A 90 49 N/A N/A 06 99 74 65 0 38 22 N/A N/A 85 44 N/A N/A 0 94 69 60 CONCENTRIC TERMINATION ELEVATION 750-0,000 ft. No. of 90 ELL Pipe Size 2 in. 2-/2 in. 3 in. Input 070 090 0 35 070 090 0 35 070 090 0 35 58 42 N/A N/A 05 64 N/A N/A 2 4 89 80 2 53 37 N/A N/A 00 59 N/A N/A 6 09 84 75 3 48 32 N/A N/A 95 54 N/A N/A 04 79 70 4 43 27 N/A N/A 90 49 N/A N/A 06 99 74 65 5 38 22 N/A N/A 85 44 N/A N/A 0 94 69 60 6 33 7 N/A N/A 80 39 N/A N/A 96 89 64 55 7 28 2 N/A N/A 75 34 N/A N/A 9 84 59 50 8 23 N/A N/A N/A 70 29 N/A N/A 86 79 54 45 9 8 N/A N/A N/A 65 24 N/A N/A 8 74 49 40 0 3 N/A N/A N/A 60 9 N/A N/A 76 69 44 35 SLP98UHV / Page 3

DIMENSIONS - INCHES (MM) - UPFLOW POSITION NOTE - 60C and 60D size units that require air volumes over 800 cfm must have one of the following:. Single side return air and Optional Return Air Base with transition that must accommodate required 20 x 25 x inch (508 x 635 x 25 mm) air filter to maintain proper velocity. 2. Bottom return air. 3. Return air from both sides. 4. Bottom and one side return air. See Blower Performance Tables for additional information. -7/8 (48) D 3-/4 (83) EXHAUST OUTLET SUPPLY OPENING 2 Optional Side Return Air Filter Kit is not for use with the Optional Return Air Base. COMBUSTION INTAKE Flue Condensate Trap Assembly Furnished for external field installation on either side of unit. (See installation instructions for additional information.) 7 (78) 2 OPTIONAL SIDE RETURN FILTER KIT (Either Side) 23-3/4 (603) 25 (635) TOP VIEW A B 9/6 (4) -/2 (38) Front Panel 27-3/4 (705) 9-7/6 (494) 9/6 (4) 2 OPTIONAL SIDE RETURN FILTER KIT (Either Side) 33 (838) 6-9/6 (67) Left 9 (229) Right 2-5/8 (32) (Either Side) ELECTRICAL INLET (Either Side) 2 (5) (Either Side) GAS PIPING INLET (Either Side) CONDENSATE TRAP CONNECTION (Either Side) 6-/2 (65) (Either Side) 4-3/4 (375) 6 (406) 23 (584) Side Return Air Opening (Either Side) 4 (356) -/2 (38) FLOW -5/6 (49) 3/4 (9) C Bottom Return Air Opening 3/4 (9) 5/8 (6) 3-/4 (83) 23-/2 (597) Bottom Return Air Opening FRONT VIEW SIDE VIEW SLP98UHV / Page 4 Model No. A B C D in. mm in. mm in. mm in. mm SLP98UH070XV36B 7-/2 446 6-3/8 46 6 406 7-5/8 94 SLP98UH090XV36C SLP98UH090XV48C SLP98UH090XV60C SLP98UH0XV60C 2 533 9-7/8 505 9-/2 495 9-3/8 238 SLP98UH35XV60D 24-/2 622 23-3/8 594 23 584 -/8 283

DIMENSIONS - INCHES (MM) - HORIZONTAL POSITION LEFT-HAND DISCHARGE 6-/2 (65) Bottom 2-5/8 (32) Bottom 6-9/6 (67) Top 9 (229) Bottom CONDENSATE TRAP CONNECTION (Bottom) FLOW ELECTRICAL INLET (Top or Bottom) 27-3/4 (705) 9/6 (4) COMBUSTION INTAKE 2 (5) Top or Bottom TOP VIEW 33 (838) GAS PIPING INLET (Top or Bottom) -/2 (38) Front Panel 3/4 (9) 27-3/4 (705) 9/6 (4) 9-7/6 (494) SUPPLY OPENING B D A FLOW 3-/4 (95) A C 23-/2 (59) RETURN OPENING EXHAUST OUTLET END VIEW 3-/4 (83) -7/8 (48) FRONT VIEW RIGHT-HAND DISCHARGE END VIEW CONDENSATE TRAP CONNECTION (Bottom) FLOW 6-/2 (65) Bottom 2-5/8 (32) Bottom 9 (229) Top 6-9/6 (67) Bottom 2 (5) Top or Bottom 27-3/4 (705) ELECTRICAL INLET (Top or Bottom) -/2 (38) Front Panel TOP VIEW 33 (838) GAS PIPING INLET (Top or Bottom) EXHAUST OUTLET -7/8 (48) 3-/4 (83) 27-3/4 (705) 23-/2 (59) RETURN OPENING C 3-/4 (95) A FLOW A D 9-7/6 (494) SUPPLY OPENING B 9/6 (4) END VIEW 3/4 (9) FRONT VIEW COMBUSTION INTAKE END VIEW 9/6 (4) Model No. A B C D in. mm in. mm in. mm in. mm SLP98UH070XV36B 7-/2 446 6-3/8 46 6 406 7-5/8 94 SLP98UH090XV36C SLP98UH090XV48C SLP98UH090XV60C 2 533 9-7/8 505 9-/2 495 9-3/8 238 SLP98UH0XV60C SLP98UH35XV60D 24-/2 622 23-3/8 594 23 584 -/8 283 SLP98UHV / Page 5

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) HORIZONTAL (END) FILTER KIT 5/8 (6) 24 3/4 (629) -/4 (32) A 5/8 (6) B RETURN OPENING 23 /2 (597) 5/8 (6) FLOW Furnace Cabinet Width Catalog Number A B in. mm in. mm B 87L96 8 457 6-3/4 425 C 87L97 2 533 8-3/4 476 D 87L98 25 635 23-3/4 603 5/8 (6) SIDE VIEW FILTER (Furnished) FRONT VIEW CONDENSATE TRAP (Furnished) Optional Return Air Base (Upflow Applications Only - For use with B, C and D cabinets) FURNACE FRONT FLOW INDOOR QUALITY CABINET (PCO, Filter Cabinet, etc.) IF BASE IS USED WITHOUT IAQ CABINET, A SINGLE RETURN PLENUM MUST COVER BOTH UNIT AND RETURN BASE OPENINGS 3-/4 (83) 7-/4 (84) 23 (584) Overall (Maximum) Unit side return air Opening 5-5/8 (43) Minimum (279) 2 Maximum 4 (356) SIDE RETURN OPENINGS (Either Side) 22-7/6 (570) Overall (Maximum) 7-/2 (446) B Width (50W98) 2 (533) C Width (50W99) 24-/2 (622) D Width (5W00) OPTIONAL RETURN BASE 26-7/8 (683) 23 (584) SIDE VIEW 3/4 (9) NOTE- Optional Side Return Air Filter Kits are not for use with Optional Return Air Base. Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet. Minimum unit side return air opening dimensions for units requiring 800 cfm or more of air (W x H): 23 x in. (584 x 279 mm). The opening can be cut as needed to accommodate plenum or IAQ cabinet while maintaining dimensions shown. Side return air openings must be cut in the field. There are cutting guides stenciled on the cabinet for the side return air opening. The size of the opening must not extend beyond the markings on the furnace cabinet. 2 To minimize pressure drop, the largest opening height possible, up to 4 in. (356 mm), is preferred. SLP98UHV / Page 6

DIMENSIONS - INCHES (MM) - FURNACE/COIL COMBINED DIMENSIONS UPFLOW POSITION Model No C35/C37/CX35/CX38 Cased C35 Uncased A B A B C35/CX35 C37 CX38 in. mm in. mm in. mm in. mm C35/CX35-8/24A C35/CX35-8/24B C35/CX35-24A C35/CX35-24B C35/CX35-30A C35/CX35-30B C37-25A C37-25B - - - - - - 6-/2 49 49-/2 257 4-/8 359 47-/8 97 CX38-25A CX38-25B 8-/2 470 5-/2 308 6-3/8 46 49-3/8 254 - - - - - - CX38-30A 20-/2 52 53-/2 359 - - - - - - - - - - - - C37-3A C37-3B C35/CX35-30/36A C37-36A C35/CX35-30/36B C37-36B C35/CX35-30/36C C37-36C C35/CX35-36A C35/CX35-36B C37-38A C37-38B CX38-3A CX38-3B CX38-36A CX38-36B CX38-36C CX38-38A CX38-38B 22-/2 572 55-/2 40 20-3/4 527 53-3/4 365 24-/2 622 57-/2 46 22-/4 565 55-/4 403 24-/2 622 57-/2 46 22-3/8 568 55-3/8 407 - - - C37-42B CX38-42B 24-/2 622 57-/2 46 - - - - - - - - - - - - C35/CX35-48B C35/CX35-48C - - - C37-43B C37-43C C37-48B C37-48C CX38-43B CX38-43C CX38-44/48B CX38-44/48C 27-/2 699 60-/2 537 26-/4 667 59-/4 505 24-/2 622 57-/2 46 - - - - - - - - - - - - C35/CX35-49C C37-49C CX38-49C 29-/2 749 62-/2 588 28-/2 724 6-/2 562 C35/CX35-50/60C C37-50/60C CX38-50/60C 27-/2 699 60-/2 537 25-7/8 657 58-7/8 495 - - - C37-60D CX38-60D 25-/2 648 58-/2 486 - - - - - - - - - - - - CX35-60C C37-62C CX38-62C 3-/2 800 64-/2 638 30-5/8 778 63-5/8 66 CX35-60D C37-62D CX38-62D 29-/2 749 62-/2 588 28 7 6 549 A 33 (838) B A B 33 (838) HORIZONTAL POSITION Model A B Number in. mm in. mm CH33 CH33-8A-2F 2-/2 546 54-/2 384 CH33-24/30A-2F, CH33-42B-2F, 26-/2 673 59-/2 5 CH33-36A-2F, CH33-36B-2F, CH33-48C-2F, CH33-60D-2F CH33-36C-2F, CH33-44/48B-2F, CH33-62D-2F 3-/2 800 64-/2 638 CH33-50/60C-2F, CH35 CH35-8A-2F, CH35-24A-2F, CH35-24B-2F, CH35-30B-2F, CH35-30A-2F, CH35-42B-2F, CH35-48B-2F, CH35-36A-2F, CH35-36B-2F, CH35-36C-2F, CH35-42C-2F, CH35-48C-2F CH35-5C-2F, CH35-60D-2F 26-/2 673 59-/2 5 3-/2 880 64-/2 638 SLP98UHV / Page 7

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) FLUSH-MOUNT VENT TERMINATION KIT 5W (US) or 5W2 (CANADA) With 2 or 2-/2 in. (5 or 64 mm) PVC pipe Exhaust Intake (Behind Plate) Seal all openings (typical) With 3 in. (76 mm) PVC pipe Exhaust Intake (Behind Plate) 2-3/8 (60) 2 (305) minimum (recommended) 2 (5) PVC pipe 3 (76) PVC pipe NOTE - PVC pipe and fittings are not furnished When required Use and must be field furnished. Field Provided 2-/2 to 2 in. (64 to 5 mm) Coupling 2-/2 (64) PVC pipe MUFFLERS 5Y66-2-inch 6A56-3-inch 2-Inch - 8-3/4 (476) 3-Inch - 25 (635) 4-/2 (4) (Installed Vertically in the Exhaust Pipe) NOTE - Two-inch mufflers do not have reducers at each end. SLP98UHV / Page 8

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) CONCENTRIC WALL TERMINATION APPLICATIONS CONCENTRIC ROOF TERMINATION APPLICATIONS EXHAUST OUTSIDE WALL INTAKE EXHAUST 2 (305) Minimum Above Average Snow Accumulation FLASHING (Not Furnished) INTAKE CLAMP (Not Furnished) INTAKE 2 (305) Minimum Above Grade or Average Snow Accumulation CLAMP SHEET METAL STRAP (Clamp and sheet metal strap must be field installed to support the weight of the termination kit.) GRADE 7M80 / 69M29 / 44W92 2 inch kits 60L46 / 44W93 3 inch kits See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. A B 6 /2 (65) 6 (52) Cat. No. 7M80 69M29 44W92 (Canada) A B in. mm in. mm 33 3/8 848 6 3/4 425 29 737 5 /2 394 3 /2 (89) 2 in. kits 4 /2 (4) 3 in. kits INTAKE EXHAUST 60L46 38 7/8 987 2 3/6 538 44W93 (Canada) 36 /8 98 9 /2 495 ELBOW (Field Supplied) TERMINATION ASSEMBLY (Furnished) Outdoor Exhaust Accelerator included with 7M80/44W92 NOTE Typical illustration for dimensions only. Design may vary depending on kit ordered. WALL ASSEMBLY TERMINATION KIT RING KIT 5F74 2 inch (5 mm) See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. DIRECT VENT APPLICATION 2 in. (305 mm) - 2 in. (5 mm) dia. exhaust pipe 20 in. (508 mm) - 3 in. (76 mm) dia. exhaust pipe maximum length without support 8 in. (203 mm) minimum 6 in. (52 mm) maximum NOTE 2 in. (305 mm) minimum height above average snow accumulation (from bottom of vent pipe). SLP98UHV / Page 9

OPTIONAL ACCESSORY DIMENSIONS - INCHES (MM) WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE 2 inch (5 mm) 22G44 (US) 3 inch (76 mm) 44J40 (US) See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. If Intake and Exhaust Pipe is less than2 in. (305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. WALL SUPPORT 8 (203) MIN. Between Ends of Exhaust and Intake Pipe 2 (305) MAX. for 2 (5) Dia. Exhaust 20 (508) MAX. for 3 (76) Dia. Exhaust 2 (305) INTAKE 6 (52) Maximum EXHAUST INTAKE 5 (27) /2 (3) FOAM INSULATION (Field Furnished) EXHAUST 8 (203) MIN. 2 (305) Minimum Above Grade or Average Snow Accumulation GRADE 5-/2 (40) 2 (305) Minimum Above Grade or Average Snow Accumulation GRADE 2 (305) MAX. for 2 (5) Dia. Exhaust 20 (508) MAX. for 3 (76) Dia. Exhaust WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE 2 inch (5 mm) 30G28 (WTK Canada) 3 inch (76 mm) 8J20 (WTK Canada) See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. If Intake and Exhaust Pipe is less than2 in. (305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. WALL SUPPORT INTAKE 6 (52) Maximum 2 (305) MAX. for 2 (5) Dia. Exhaust 20 (508) MAX. for 3 (76) Dia. Exhaust 6 (52) MIN. EXHAUST INTAKE 5 (27) 2 (305) /2 (3) FOAM INSULATION (Field Furnished) EXHAUST 6 (52) MIN. 2 (305) Minimum Above Grade or Average Snow Accumulation GRADE 2 (305) MAX. for 2 (5) Dia. Exhaust 20 (508) MAX. for 3 (76) Dia. Exhaust 5-/2 (40) 2 (305) Minimum Above Grade or Average Snow Accumulation GRADE SLP98UHV / Page 20