Design of Multi-Sensors Cooperation Control System for Intelligent Building

Similar documents
Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Design of Classroom Intelligent Lighting System Based on SCM. Jiale Zheng1, a

Design of Mine Safety Detection Alarm Based on Single-chip Mingtao Ma

"Three Preventions" System Design Based On Single-Chip Microcomputer (SCM) Control Jiaxiong Wen

Research on the Monitor and Control System of Granary Temperature and Humidity Based on ARM

Design of Microwave Anti-theft Alarm Based on Microcontroller

The Mode of Urban Renewal Base on the Smart City Theory under the Background of New Urbanization

Design of Intelligent Alarm System Based on GSM Network Shun Qing XU

Design and Implementation of a Real Time Wireless Monitor System for Urinary Incontinence

The Design of MLX90621 Based Intelligent Lighting Control System Hui-jiao Wang*, Meng-meng Liu and Cong-cong Shi

Design and Realization for the Environmental Protection Type of Pig-Farm Model Based on the Sensor Technology

The Design of Temperature Control System for Vegetable Greenhouse

Design of an Infusion Rate Control System Based on Single Chip Microcomputer

Construction of Wireless Fire Alarm System Based on ZigBee Technology

Application of Fuzzy Control in Central Air-conditioning Terminal Units Energy-saving

Design of Intelligent Humidity Sensing Watering System Based on MCU

Construction of An Automatic Power Switch using Infrared Motion Sensor

The design of the human body infrared thermometer

Temperature and humidity controller system based on single chip microcomputer

Design of Intelligent Home Alarm System Based on ARM

Intelligent monitoring system for automobiles

IOT ENABLED FOREST FIRE DETECTION AND ONLINE MONITORING SYSTEM

Design of Cold Light Source System for Medical LED Endoscope

SAFETY PRE-ALARM MONITOR SYSTEM BASED ON GSM AND ARM

ENACTMENT OF SCADA SYSTEM FOR JUDICIOUS DWELLING

Experimental Research on Monomial Cooling Measure of Greenhouse in Summer

[Patil* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

*Corresponding author # Presenting author DOI: /jki th International Working Conference on Stored Product Protection

The design of automatic remote monitoring system for the temperature and humidity based on GPRS Hui ZHANG 1, a, Honghua WANG 2,a

Design of Unmanned Monitoring and Automatic Monitoring System

Design and Implementation of Sewage Treatment Control System

Design of Humidity Monitoring System Based on Virtual Instrument

Hazardous Gas Detection using ARDUINO

Experimental Study of Dual Heater Slider Touchdown Detectability

International Journal of Scientific Research and Reviews

Smart Garbage Monitoring System for Waste Management

Design of Multi-Functional Alcohol Concentration Detecting System Zhang Chong, Zhang Yue

CFD Analysis of Fire Characteristics on Subway Junction Station

2-wire Passive Intelligent Loop (LED) Display Meter

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM.

Multi-sensor System For Indoor Environment Monitoring Zheng-yu Wanga, and Xiao-ru Zhangb

A Design Method Based on Inherent Testability of Remote Control and Monitoring System for Marine Main Engine

Smart Home: Controlling and Monitoring Households Appliances Using Gsm Network

A Survey on implementation of Fire detection System Based on ZigBee Wi-Fi Networks

Android Controlled Fire Fighting Robot

AUTOMATIC STREET LIGHT CONTROL SYSTEM USING MICROCONTROLLER

2-wire Passive Intelligent Loop (LED) Display Meter

All DC Inverter Multi VRF

6367(Print), ISSN (Online) Volume (IJCET) 3, Issue 2, July- September (2012), IAEME

Designation and Construction of Solar Panel-based Washing Machine. Seyed Amin Hashemi 1, Saeed Zamani 2

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

White Paper MEMS Non-Contact Temperature Sensor

Performance evaluation of an innovative fan-coil unit: Low-temperature differential variable air volume FCU

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Frequently asked questions: Intelligent Transmitter Series

A design of automatic boiler intelligent alert system based on the wireless AD hoc network

Temperature and Humidity Monitoring System for Embedded Computer

II. METHODS AND MATERIALS

Development of Open BIM-based Code Checking Modules for the Regulations of the Fire and Evacuation

Design of CO Concentration Detector Based on Infrared Absorption Method

New fire control system design for fire fighting and rescue equipment Jianguo LUO1, a, Zehao BU2, b

The Strategic Thinking on Promoting the Specialized Towns New-Style Urbanization Construction in Guangdong Province

Experimental Study of Initial Process of Frost on Heat Exchanger Surface of Refrigerated Transport Vehicle

Industrial and home safety Management using GSM

Firefighting Robot. I. Introduction

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

Research on Decision Tree Application in Data of Fire Alarm Receipt and Disposal

GSM POWER ALARM SYSTEM

A Smart House in the Context of Internet of Things

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Gas Detection Instrument Based on Wireless Sensor Networks

A Novel Online Cleaning System for Shell and Tube Oil Heat Exchanger

A Study on Improvement of Fire Protection Systems based on Failure Characteristics accodrding to Yearly Variation in Old Commercial Buildings

Participatory budget of Wrocław as an element of Smart City 3.0 concept Dorota Bednarska-Olejniczak Jarosław Olejniczak, PhD

International Journal of Scientific & Engineering Research Volume 9, Issue 2, February-2018 ISSN

The Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Energy Audit. This guide is for a 6 month Silver Award project. It is suitable for both group and individual volunteering.

A Design of IADSS with the Earthquake Detecting Function

Laser Alarm System based on GSM Module Family

DeviceNet Mass Flow Controller, the SEC-Z10D Series

Intelligent Fire Detection and Visual Guided Evacuation System Using Arduino and GSM

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

Indoor thermal comfort by controlling heat transfer through building envelope

DGE 2 EUROPEAN UNION. Brussels, 20 September 2017 (OR. en) 2016/0287 (COD) PE-CONS 28/17 TELECOM 158 FC 54 CODEC 1008

A Real-Time Approach for Home Security and Alert System using CAN Protocol

Break-in Detector and Alarm System

Development of Bionic Air Cooler Used in High Temperature Coal Mine

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Applications of Smart Home system for disabled people for using wireless network

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

Microcontroller based design for Tele-sensing and extinguishing fire

Design of Gear Defect Detection System Based on Machine Vision

Different types of Fire Alarm System

IOT Based Intelligent Bin for Smart Cities

A Low-Cost Intelligent Thermostat Incorporating a Learning Algorithm Based Scheduler and Internet Accessible Control Interfaces

Design and Development of General Purpose Alarm Generator for Automated System

Installation Guide for inbiox60 Series Access Control Panel

Virtual Boundary System Using Passive Infrared Sensor

Ningbo Initiative - APEC High-Level Urbanization Forum 2016

Transcription:

Energy and Power Engineering, 2017, 9, 495-502 http://www.scirp.org/journal/epe ISSN Online: 1947-3818 ISSN Print: 1949-243X Design of Multi-Sensors Cooperation Control System for Intelligent Building Qi-Jiao He, Lin Ye School of Power and Energy, Northwestern Polytechnical University, Xi an 710072, China How to cite this paper: He, Q.-J. and Ye, L. (2017) Design of Multi-Sensors Cooperation Control System for Intelligent Building. Energy and Power Engineering, 9, 495-502. https://doi.org/10.4236/epe.2017.94b055 Received: November 27, 2016 Accepted: March 30, 2017 Published: April 6, 2017 Abstract This paper presents a design of intelligent building control system based on multi-sensors. In order to achieve comfort, low carbon and energy conservation for buildings. The design uses STC89C52 chip, combined with monitoring data of Pyroelectric infrared microwave dual sensor, temperature sensors and light sensors to control the optical system, the temperature control system and the security system. It helps to achieve low carbon and energy conservation. In addition, the energy-saving effect of a medium-sized multimedia classroom was analyzed. We analyze the feasibility of the system. It is proved that the system is low cost, high yield and easy to operate, with strong engineering application value. Keywords Intelligent Building, Multi-Sensors, Control System, STC89C52 1. Introduction In recent years, the global energy shortage and environmental pollution problems have become increasingly serious. The temperature control system technology for buildings cannot update quickly. For example, the increasing problem of air conditioning diseases [1] has proved that the old system cannot guarantee the comfort for people. It is urgent to people to take new technology to achieve comfort with emission reduction at the same time. Furthermore, according to the report of the world energy organization [2], China s total energy consumption in 2030 will reach 15 tons standard coal. At present, China s energy consumption of buildings is 3 times the consumption of other countries in the same latitude, and accounts for 30% - 40% of the total energy consumption of the country, while in energy consumption of buildings, the energy consumption of air conditioners and ventilating equipment accounts for about 55%; DOI: 10.4236/epe.2017.94B055 April 6, 2017

energy consumption of lighting and elevators accounts about 24%. That is to say, each new building means that an increase of energy consumption and emissions, followed by a large number of power consumption, coal consumption [3] [4]. With the development of economy and technology, the technology of automatic intelligent and energy saving control for buildings appears and develops well, and this technology can also achieve energy conservation, comfort and practices. The automatically systems with Real-time adjustment and control are bound to become the mainstream of the future architecture. At present, the building energy conservation is mainly from two aspects: the architectural design and the building intelligent system. The architectural design which is related to energy conservation mainly involves the overall structure of buildings, envelopes and the comfort of indoor environment; and the intelligent buildings depends on the advanced networking technology to realize automatic management for buildings, and realize the electricity, lighting, air conditioning, control security, disaster prevention, transportation equipment for buildings, and office automation is a kind of intelligent control management, which helps to build a modern intelligent building [5]. In order to achieve low carbon and energy conservation for buildings, in this paper, the energy-saving control system of new buildings was studied, combined with multi sensors (Pyroelectric infrared microwave dual sensor, temperature sensor, photoresistor) and the embedded control system which intelligently updates light & shade optical system, air conditioner & fan controlling system, anti-theft & fire security system, in order to reduce building energy consumption, and improve comfort, social productivity and quality of life and energy conservation. 2. Design of System 2.1. Construction of System The energy saving control system consists of eight independent modules: data processing module of Microcontroller, respondent module of pyroelectric infrared microwave dual sensor, indoor and outdoor photometric sampling module, indoor and outdoor temperature sensor and display module, temperature controlling module, lighting controlling module, curtain controlling module, and alarm module. Among these, pyroelectric infrared microwave dual sensors and the photosensitive resistances are besides each lamp, and the temperature sensors are installed in the interior. Three kinds of sensors judge collaboratively, in four operating modes, namely summer normality, winter normality, summer anti-theft, winter anti-theft, and operate respectively for light & shade optical system, air conditioner & fan controlling system, anti-theft & fire security system. 2.2. Design of Light Control System As for lighting problem, according to the difference of time, place, person flow, outdoor light intensity, controlling systems use the preset value control mode 496

to set up light intensity exactly and manage it reasonably, and this helps not only save energy expenses, but also to extend the service life of the lighting equipment. The pyroelectric infrared microwave dual sensor next to the lamp is used to detect whether there are people in the region. If there is a person in the range of the human body infrared sensor module, it will output high level to the microcontroller I/O port to carry out the corresponding operation. The light intensity of surroundings of lights and curtains are measured by the photoresistor, and after this each light and curtains will carry out their signals [6]. If the Lighting system detects the emergence of a people, the system will start work. If people in the chamber with dark light, it will open lights in this area, and if the light is strong, it will choose not to turn on the lights. Each lamp works independently, in order to save energy as much as possible. If the person leaves the room, the lighting system will automatically close. The curtain system, whether or not detected people, is open by default. When the outdoor temperature is higher than 30 degree, or the light intensity of a curtain is higher than a certain threshold, the system will automatically close the curtains; until the outdoor light intensity is below the warning level, this helps to pull the curtains to reduce the aging and damage caused by the summer sun. On this basis, we can use only one button to switch to the projection mode, and also close the corresponding curtains and lamps, in order to create a better projection experience for audiences. In addition, the manual control of the curtain can also be controlled by the physical buttons. The personalized design is very convenient and quick. 2.3. Design of Temperature Control System Temperature control system is aimed primarily to adjust target of air conditioning and fans. Temperature control system module adopt temperature sensor DS18B20, which has a smaller size, higher accuracy, wider applicable voltage, using first-line bus, making a good test in the practical application of temperature effect [7]. Using temperature sensors to detect indoor and outdoor temperatures, combined with indoor and outdoor temperature determines different seasons to adopt different logic. Comparing the sensor signals and system settings, in order to make the appropriate operation of the air conditioning, fan. Meanwhile, the combination of Pyroelectric infrared microwave dual sensor data, namely people distribution inside and the number of people inside the room dynamic partitioning wind direction and speed control, with indoor and outdoor temperature at room temperature instead of a single overall judgment judge. At the same time, the use of fans with air-conditioning work, quickly lower the temperature, so temperature control was maintained at 26 C - 27 C, which is both effectively save resources and improve human comfort, when it is detected that staff leave the room, immediately turn off the fan, delayed 15 minutes turn off air conditioning, choosing the delay to reduce the waste of resources caused by frequent 497

switching machine. 2.4. Design of Security System In this modular system, fire prevention function work in real time. Upon detecting a temperature higher than 45 C, it informs warning center immediately via the communication bus, and the buzzer sounding to alert the floor staff, the maximum extent possible to reduce the loss of fire. Anti-theft mode controls on and off through a physical buttons. In the anti-theft mode turned on, embedded system controls whether an alarm sounds or not. If someone invaded, informs warning center immediately via the communication bus. Communication bus adopts paved telephone line in order to reduce costs. 3. Design of Hardware & Software 3.1. Design of Hardware The system adopts STC89C52 as the core of control which is a low-power, high-performance CMOS8 bit microcontroller with 8 K code space, 512 K of data storage space, which can use the serial port to download directly. On a single chip, with dexterous 8 CPU and in-system programmable Flash, so STC- 89C52 provide highly flexible, ultra-effective solution for many embedded control applications. Figure 1 shows minimum system diagram of Microcontroller (STC89C52) [8]. Figure 1. Minimum system diagram of Microcontroller (STC89C52). 498

The system adopt hardware Q74 pyroelectric infrared sensor to monitor whether someone appears indoor, adopting DS18B20 temperature sensor to detect indoor and outdoor temperature, and using photoresistor to detect the light intensity indoor. Figure 2 shows a circuit diagram of the system hardware. 3.2. Design of Software Control System The system adopts STC89C52 as the core of control in charge of logic operation of the entire system, so the good or bad software design is the key to whether the stable operation of the system and the ability to achieve design features. In the modular scheme is adopted in the software implementation, the entire software designed by initialization module, interrupt processing module, data display module and output real-time module of four modules, the corresponding module C programming language program in the microcontroller. After debugging, it expected to achieve control of light control system, temperature control systems and security systems. Figure 3 shows a software system of design flow. 4. Energy Saving Analysis & Environmental Impact Assessment According to the survey, the vast majority of domestic construction does not use energy-saving measures, and energy consumption is more serious. The intelligent building energy-saving control system is a reasonable design for the current Figure 2. A circuit diagram of the system hardware. 499

Figure 3. A software system of design flow. shortage, with a medium-sized multimedia classroom at the University as an example, the system of energy-saving effect as shown in Table 1. By comparison, the use of the system in each classroom can save 2368.5 kwh of electricity per year, saving 46.3 percent. Equivalent to an annual saving of classroom fired 0.95 ton, reducing C emissions 0.64 ton, 2.36 ton of CO 2 emissions reduction. The system can effectively reduce the amount of waste energy construction sector, on the one hand to achieve the energy saving purpose, on the other hand to improve the life and safety of electrical equipment, and only on the basis of the original circuit was modified without updating existing electrical equipment, low cost, high yield, easy to operate, with high engineering value. 5. Conclusion With the development of society, high energy-consuming products have been 500

Table 1. The system of energy-saving effect. Before use (kwh) After use (kwh) Energy savings Lamps 1555.2 920.7 40.8% Air Conditioning 2808 1446.1 48.5% Ceiling Fans 748.8 373.7 50.1% Buzzer - 3 - Total 5112 2743.5 46.3% gradually phased out, and the idea of energy conservation and emission reduction enjoy popular support. Building as an essential place for people s production, living, and l earning, optimize the control of energy saving has become the object of study. In this study, the establishment of a multi-sensor based control system, the system using multi- sensor light control system, temperature control system and the security system real-time energy-saving control, and system energy saving test, medium-sized multi-media classrooms each year can save 46.3%, saving 2368.5 kwh. At the same time, with the use of modular design, the user can choose according to their needs which several modules to upgrade to fully meet the individual needs. In the building of energy-saving control system can greatly reduce the energy consumption of buildings, and to make the environment more comfortable. And may be building more low-carbon energy, this will bring certain economic benefits. Acknowledgements The authors acknowledge gratefully the financial support from National Undergraduate Training Program for Innovation and Entrepreneurship (Grant No. 201410699051). References [1] Wu, X.P. (2000)The Volume of Outdoor Air, the Way of Air Distribution and Air Conditioning Diseases. Building Energy & Environment,19. [2] Organization. (2007) WHO. Housing, Energy and Thermal Comfort: A Review of 10 Countries within the WHO European Region. Copenhagen Who Regional Office for Europe. [3] Sun, T.Y., Ma, Q., Huang, J. (2015) Energy-saving Control System Design Based on Internet of Things for building. Value Engineering, 15, 61-64 [4] Yao G.Y, Song L. (2014) Design of Library Lighting Energy Saving System Based on Internet of Things. Applied Mechanics & Materials, 496-500, 1690-1693. https://doi.org/10.4028/www.scientific.net/amm.496-500.1690 [5] Xu Y. (2008) On the Building Automation System of Intelligent Buildings. Intelligent Building Electrical Technology, 2, 15-18. [6] Liu, S.Q., Shi, G. L. (2005) Alarm System with Pyroelectric Infrared Sensors. Electronic Design Engineering, 3, 18-20. [7] Hu, T.M., Qi, J.J. (2008) The design and application of digital thermometer based on DS18B20. Journal of Heilongjiang Institute of Technology, 22, 59-62. 501

[8] Wu, J., Hou, W., Zheng, B. (2011) A Temperature Control System Based on STC89C52 MCU. Computer Knowledge and Technology, 7, 902-903. Submit or recommend next manuscript to SCIRP and we will provide best service for you: Accepting pre-submission inquiries through Email, Facebook, LinkedIn, Twitter, etc. A wide selection of journals (inclusive of 9 subjects, more than 200 journals) Providing 24-hour high-quality service User-friendly online submission system Fair and swift peer-review system Efficient typesetting and proofreading procedure Display of the result of downloads and visits, as well as the number of cited articles Maximum dissemination of your research work Submit your manuscript at: http://papersubmission.scirp.org/ Or contact epe@scirp.org 502