TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

Similar documents
Model 4880 Status Output Display Module Manual

ME 3011C / Alarm Indication / Quick Reference Guide

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

MSM - Expansion modules

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

EOTec 2C32 Installation Guide

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

RS485 MODBUS Module 8AI

ACCURATE ELECTRONICS INC

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

EL-OEM-3 OEM Packaged Voltage Data Logger

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

8-Channel Thermocouple Input Ethernet Data Acquisition Module

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

IF-L/RF Protection Switch

Maintenance Manual ALARM SHELF 19D902821P1 & P2. ericssonz LBI-38496C. TABLE OF CONTENTS (Vendor Documentation)

Flair 500 Series Annunciators

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

8-port Unmanaged Industrial Ethernet Switch Hardware Installation Guide

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Engineering Guideline. pac- Carriers Type Universal

PTE0705 Electric Fence Monitor

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

1.1 Remote Annunciator Controller (RAC) and 1 Switch (ATC-600/800) via Modbus TCP/IP Ethernet Gateway

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Added password for IP setup page : Password must be in IP format!

TAZUNA Unit: TAZ-111. PQ roid (Drill Identification System) User s manual. Important

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

P2267 NETWORK INTERFACE

TC Channel Serial-over-T1/E1 Multiplexer. User Manual MNL

Instruction Manual Model Backup Switch, 1 for 8

Table of Contents SECTION PAGE

OPERATION / INSTALLATION

RTD TEMPERATURE SENSING SYSTEM

Universal fault annunciator for panel mounting

Water Detection Controllers

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

Vess A2000 Series. IO Terminal Board. User Information. Version PROMISE Technology, Inc. All Rights Reserved.

Heimdall Radar Traffic Detector

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Standard Industrial Types RI 80-E

Ethernet General Purpose

EX41922 Hardened Unmanaged 2-port 10/100/1000BASE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

STATUS ALARM HISTORY ALARM RESET

INSTALLATION INSTRUCTIONS. Anti Knocking System, AKR 3. Document no.: A SW version:

CASS9000 Standalone FingerPrint Door Access System. User Manual

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

UNC100 Integra Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Analog Input Module IC670ALG630

21-light Remote Annunciator. Owner s Manual

Network converter CC-Link compatible

Fiber Optical Multiplexer

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

Model 1062 Environment Monitor

Digital Heater Element Burnout Detector K8AC-H

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Heimdall Radar Traffic Detector

EX41922-T Hardened Unmanaged 2-port 10/100/1000BASE PoE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

API MARINE BMS4 REMOTE SOUNDING SYSTEM FOR BALLAST AND SERVICE TANKS

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

IP Access FACP Adapters. Installation Guide. Entrada2DMK - IP Access FACP Adapter Kit. Kit Includes: Entrada2DMR - IP Access FACP Receiver

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Heimdall Radar Traffic Detector

ECO N DATE DESCRIPTION OF CHANGE CHG

4 Channel Contact Closure SFP DIN Fiber Link System

Fratech Multipath-IP

Operating Instructions tico Temperature Indicator

Sierra Series 900 Single & Dual Channel System. Instruction Manual

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

T a b l e o f C o n t e n t s

USER MANUAL FOR OPERATING SYSTEM

Temperature Controllers

Symmetra MW Modbus Data Points

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

Model A1700 Series Annunciator

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL

GDC 087R Issue 1 - May Installation and Operation UAS Network/Dropside Interface Unit Model NIU/DIU 7624.

HUM-M2 Humidity Sensor Module Description

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

AO Annunciator Module

SPLIT-DECODED CONTROLLER

Built-on speed controller for GMPM plug fan with permanent magnet motor

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

Public Safety DAS Annunciator Panel

Model T B Intraoffice T1 Repeater User Manual

Eclipse Nursecall Systems Ltd. Clipper Plus & Clipper ID. Document V.2.1b (Basic) ENS. Freedom Through Technology

Transcription:

Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal Specifications Size: (L122 x W123 x H104 mm) Series Interface: Half duplex RS-485 with transformer isolation Cable Type: CAT5 UTP/STP Ethernet Cable Surge Protection: 10KV Transfer Rate: 2.5Mbps, 5Mbps, 10Mbps, 20Mbps IO Isolation Voltage: 2.5KVrms Output Types: NPN open collector Darlington transistors Switch Capacity: each output channel is 350mA/channel maximum at 24V DC Response Time: On to Off about 50μs, Off to On about 8μs Over Current Protection: 3A (max) for each port (8-channel) Input Voltage: +24 VDC ±10% Power Consumption: 6W typical Working Temperature: 0 ~ 60 C Ordering Information 107-D108-XN 64-channel digital output with NPN IO interface Label CN1 CN2 R_CN3 L_CN3 R_CN5 L_CN5 R_CN6 L_CN6 R_CN7 L_CN7 R_CN8 L_CN8 Function Motionnet Communication Control Connector Motionnet Communication Control Connector Power Connector Power Connector 1

LED Description Disp Label Disp Label Disp Label 00 Port#0 Bit0 14 Port#1 Bit4 30 Port#3 Bit0 00 03 04 07 10 13 14 17 20 23 24 27 30 33 34 37 P 0 P 1 R E PORT#1 PORT#2 PORT#3 00 01 02 03 04 05 06 07 PORT#0 01 Port#0 Bit1 15 Port#1 Bit5 31 Port#3 Bit1 02 Port#0 Bit2 16 Port#1 Bit6 32 Port#3 Bit2 03 Port#0 Bit3 17 Port#1 Bit7 33 Port#3 Bit3 04 Port#0 Bit4 20 Port#2 Bit0 34 Port#3 Bit4 05 Port#0 Bit5 21 Port#2 Bit1 35 Port#3 Bit5 06 Port#0 Bit6 22 Port#2 Bit2 36 Port#3 Bit6 07 Port#0 Bit7 23 Port#2 Bit3 37 Port#3 Bit7 10 Port#1 Bit0 24 Port#2 Bit4 P0 DC 24V 11 Port#1 Bit1 25 Port#2 Bit5 P1 DC 5V 12 Port#1 Bit2 26 Port#2 Bit6 R RUN 13 Port#1 Bit3 27 Port#2 Bit7 E ERROR Connector Reference Motionnet communication control connector 1 NC Reserved 2 NC Reserved 3 D+ Differential D+ signal 4 NC Reserved 5 NC Reserved 6 D- Differential D- signal 7 NC Reserved 8 NC Reserved Power connector 1 24V DC 24V 2 GND DC 24V ground 3 FG Field ground 2

I/O control connector R_CN5 1 Out_00 Port#0 Bit0 Output 2 Out_01 Port#0 Bit1 Output 5 Out_02 Port#0 Bit2 Output 6 Out_03 Port#0 Bit3 Output 7 Out_04 Port#0 Bit4 Output 8 Out_05 Port#0 Bit5 Output 11 Out_06 Port#0 Bit6 Output 12 Out_07 Port#0 Bit7 Output R_CN6 1 Out_10 Port#0 Bit0 Output 2 Out_11 Port#0 Bit1 Output 5 Out_12 Port#0 Bit2 Output 6 Out_13 Port#0 Bit3 Output 7 Out_14 Port#0 Bit4 Output 8 Out_15 Port#0 Bit5 Output 11 Out_16 Port#0 Bit6 Output 12 Out_17 Port#0 Bit7 Output R_CN7 1 Out_20 Port#0 Bit0 Output 2 Out_21 Port#0 Bit1 Output 5 Out_22 Port#0 Bit2 Output 6 Out_23 Port#0 Bit3 Output 7 Out_24 Port#0 Bit4 Output 8 Out_25 Port#0 Bit5 Output 11 Out_26 Port#0 Bit6 Output 12 Out_27 Port#0 Bit7 Output R_CN8 1 Out_30 Port#0 Bit0 Output 2 Out_31 Port#0 Bit1 Output 5 Out_32 Port#0 Bit2 Output 6 Out_33 Port#0 Bit3 Output 7 Out_34 Port#0 Bit4 Output 8 Out_35 Port#0 Bit5 Output 11 Out_36 Port#0 Bit6 Output 12 Out_37 Port#0 Bit7 Output 3

I/O control connector L_CN5 1 Out_00 Port#0 Bit0 Output 2 Out_01 Port#0 Bit1 Output 5 Out_02 Port#0 Bit2 Output 6 Out_03 Port#0 Bit3 Output 7 Out_04 Port#0 Bit4 Output 8 Out_05 Port#0 Bit5 Output 11 Out_06 Port#0 Bit6 Output 12 Out_07 Port#0 Bit7 Output L_CN6 1 Out_10 Port#0 Bit0 Output 2 Out_11 Port#0 Bit1 Output 5 Out_12 Port#0 Bit2 Output 6 Out_13 Port#0 Bit3 Output 7 Out_14 Port#0 Bit4 Output 8 Out_15 Port#0 Bit5 Output 11 Out_16 Port#0 Bit6 Output 12 Out_17 Port#0 Bit7 Output L_CN7 1 Out_20 Port#0 Bit0 Output 2 Out_21 Port#0 Bit1 Output 5 Out_22 Port#0 Bit2 Output 6 Out_23 Port#0 Bit3 Output 7 Out_24 Port#0 Bit4 Output 8 Out_25 Port#0 Bit5 Output 11 Out_26 Port#0 Bit6 Output 12 Out_27 Port#0 Bit7 Output L_CN8 1 Out_30 Port#0 Bit0 Output 2 Out_31 Port#0 Bit1 Output 5 Out_32 Port#0 Bit2 Output 6 Out_33 Port#0 Bit3 Output 7 Out_34 Port#0 Bit4 Output 8 Out_35 Port#0 Bit5 Output 11 Out_36 Port#0 Bit6 Output 12 Out_37 Port#0 Bit7 Output 4

SW1: node number setting SW1 S W2 1 2 3 4 5 6 1 2 3 4 5 A5 A4 A3 A2 A1 A0 B1 B0 T D T M BK N 1 2 3 4 5 6 SW1 Pin Label On Off 1 A5 1 0 2 A4 1 0 3 A3 1 0 4 A2 1 0 5 A1 1 0 6 A0 1 0 Note that node number = 32 x A5+16 x A4+8 x A3+4 x A2+2 x A1+A0. Default values are all off. SW2: function setting Pin Label Description On Off 1 B0 *Baud-Rate Setting 1 0 SW1 S W2 N 1 2 3 4 5 SW2 2 B1 *Baud-Rate Setting 1 0 3 TD Time-Out Status Latch Enable Disable 4 TM Watch Dog Mode Enable Disable 5 TR Termination Resistance Enable Disable 1 2 3 4 5 6 1 2 3 4 5 A5 A4 A3 A2 A1 A0 B1 B0 T D T M BK The table below shows the settings of transfer rates. Default value is 10Mbps. N 1 2 3 4 5 6 Default Setting B0 B1 Transfer rate OFF OFF 20Mbps ON OFF 10Mbps OFF ON 5Mbps ON ON 2.5Mbps Output Signal Circuit NPN Relay_1NO Output Signal I < 350mA +24V R > 1.2K GND Internal Circuit 5

RS-485 Terminal Resistance When you use 107-D1xx series Module as the last one in Motionnet Ring, it is necessary to put RS-485 terminate resistance on the RJ-45 connector (CN2). Since 2016.07.01, 107-D1xx series has built in TR function, so you could turn on TR to replace RJ-45 terminate resistance Notice It is necessary to attach two EZM-D1xx modules on this terminal to ensure the Motionnet communication. 6