CP1-C5 COMPACTOR SPECS 2009

Similar documents
ENVIRO-PAK. Operation and Maintenance Manual. Manufacturer of

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

University Apartments on Brooklyn PROJECT MANUAL

Understanding the Benefits of Compaction

Revitalize Building Mechanical Systems (4619)

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

SECTION FIRE PUMP AND CONTROLS

Always keep this manual in a safe readily accessible location. MODEL SERIAL SERVICE COMPANY TELEPHONE NUMBER

SECTION WATER-TUBE BOILERS

Emery County Senior Center Green River 06/07

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

SECTION AIR DOORS

Owner & Operator Manual

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Construction Standards Page

SECTION GENERATOR PARALLELING CONTROLS

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

Design & Construction Standards, Revised January

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

Vertical Downstroke Baler. Designed For: * Warehouses * Retail Chains * Distribution Centers * Manufacturing Plants *

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION DOMESTIC WATER HEATERS

BuildingName The Description of the Project P DOCUMENTS

Q: Oil heater installed in hydraulic tank? A: We require an oil heater thermostatically controlled installed on the Hydraulic tank.

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

Owner & Operator Manual

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

SECTION Fire Pumps

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

SECTION ENCLOSED CONTROLLERS

SECTION AUTOMATIC TRANSFER SWITCHES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

TC-720 RECYCLING BALER

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

BWS 1000 OPERATION AND MAINTENANCE MANUAL

CP-711. Stationary Compactor

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

RESIDENTIAL APPLIANCES DIVISION 11 - EQUIPMENT PN A

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION AUTOMATIC TRANSFER SWITCHES

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

D. Reference Standards (Utilize latest editions available):

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

Process Protection. MFA 4P Motion Failure Alarm

SECTION COMPRESSED-AIR EQUIPMENT FOR LABORATORY FACILITIES

Engineering Specifications

SECTION SECURITY TESTING AND COMMISSIONING

SECTION FAN COIL UNITS

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION ELECTRIC WATER HEATERS

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

FIRE SUPPRESSION SPRINKLER SYSTEM

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

STANDARD TECHNICAL SPECIFICATION FOR LEVEL SWITCH (FLOAT/DISPALCER TYPE) VOLUME - IIB. SPECIFICATION No: PES

BLG77 Rising Fenced Barrier

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

CP-4101 CP-4101-HD. Stationary Compactor

SECTION DOMESTIC WATER PUMPS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

SECTION AIR COMPRESSORS AND ACCESSORIES

PART GENERAL 1.01 SECTION INCLUDES

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

I. INSTALLATION INSTRUCTIONS

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

SECTION STEAM CONDENSATE PUMPS

C&M REAR FEED Long-stroke Vertical Down-stroke Baler for Baling Multi-Materials

IN2 Lighting Control Devices

CONTENTS AUTOMATIC TRANSFER SWITCHES

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

SECTION STEAM CONDENSATE PUMPS

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

SECTION SPRINKLER SYSTEMS

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

EXPERIENCE RESULTS WITH HIGH DENSITY COMPACTORS

B. Section Identification for Fire Suppression Piping and Equipment.

B. Product Schedule: For appliances. Use same designations indicated on Drawings.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

STR-Series Indirect-Fired Air Turnover Units

Material Design for Central Chutes

SECTION CUSTOM FABRICATED LABORATORY EQUIPMENT. This section specifies necropsy // dissecting tables // and // animalcage

A. Product Data: Include rated capacities, furnished specialties and accessories.

Transcription:

SECTION 11172 / 14560 TRASH COMPACTOR This section is based on a system produced by: Architectural Refuse Solutions, LLC 525 Kennedy Road Akron, Ohio 44305 Part 1 GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract, including General and Supplementary Conditions and Division 1, General Requirements, apply to the work specified in this section. 1.2 DESCRIPTION OF WORK A. Work Included: Furnish and install waste compactor Model: CP1-C5 with two 2 cubic yard containers front or rear load and ancillary equipment as indicated on the Drawings and as specified within and as manufactured by Architectural Refuse Solutions, LLC. and represented by Ben F. Perry Co., Inc. at 770-441-9141 1.3 SUBMITTALS A. Product Data: Submit manufacturer s product specifications, performance data sheets and installation instructions. B. Shop Drawings: Submit plans, elevations, and details for work not fully shown by published product data; include rough in dimensions and service connection. C. Quality Assurance/Control Submittals: I. Contractor's Certification that: a. products of this section are manufactured by Architectural Refuse Solutions, LLC b. Manufacturer's certification that installer of manufacturer's product is approved II. Applicable standards a. National Fire Protection Association (NFPA-82, Edition) Standards as referenced herein. b. National Electric Code c. ANSI Z-245-1 (Compactor and Containers) D. Close-out Submittals: a. Operation and Maintenance Data b. Warranty Documents: Issued and executed by the manufacturer and installer of the system. 1.4 QUALITY ASSURANCE Page 1

A. Qualifications: I. Manufacturer: Minimum five (5) years-documented experience producing products specified in this section and shall maintain a servicing and replacement parts system for at least 3 years after installation of equipment. II. Installer: Approved by the Manufacturer, and having a minimum of five (5) years experience. III. The work in this section shall be subject to all applicable provisions of governing building codes and ordinances. 1.5 RELATED WORK BY OTHERS SPECIFIED ELSEWHERE A. The following work is excluded from the scope of work in this section 11175 and is included in other divisions of the specifications for inclusion in the scope of work of others. I. Concrete work Section 03300 Cast in Place Concrete II. Rubbish Chute Section 11175 Chutes and Collectors (See:Architectural Refuse Solutions) III. Floor drains, hose bibs, and sprinkler system Division 15 Mechanical IV.Electrical wiring to control panels, and wiring from control to disconnect box panels Division 16 Electrical 1.6 PRODUCT DELIVERY, STORAGE AND HANDLING A. Protection: Equipment shall be protected at all times from physical damage, dirt, water etc. B. Under no circumstances shall the compactor be used for construction trash, or any other use other than what it was intended for, namely: Normal, Daily Household Garbage Deposits by the end users. 1.7 WARRANTY A. Manufacturer s warranty: Furnish manufacturer s standard one (1) year warranty from date of temporary certificate of occupancy or similar, locally mandated permission to use the project common areas for their intended use. Warranty shall apply to defects in product workmanship and materials. B. Any use other than the intended use described in Section 1.6 B shall cause revocation of the warranty. Part 2 PRODUCTS Page 2

2.1 COMPACTOR A. General I. he compactor shall be a model CP1-C5 container compactor, as manufactured by Architectural Refuse Solutions L.L.C. with manufacturer s standard powder coat finish. B. Operation I. The compactor operation shall be automatically controlled when the compaction chamber fills to the level where the photo sensor activates the compaction ram. II. The compactor ram shall compact the material into the attached container and shall continue to cycle until all refuse is cleared from the chamber. III. When the container is full, the compactor shall automatically shut down and activate the Full display on the LCD read out C. Structural I. The compactor Main Frame/Hopper shall be an integral ¼ plate. II. The Ram shall be ¼ plate top and bottom with a 3/8 plate face. III. Impact plate shall be ¼ reinforced plate. IV.The compactor Floor plate shall be 3/8. D. Hydraulic System I. The Hydraulic System shall include a 4 gpm pump, 5 HP motor, II. 18 gallon gasketed reservoir, and 4 bore x 30 stroke cylinder. a. The Hydraulic System shall be rated at 3000 psi. E. Electrical System I. The electrical System shall include a programmable controller, convertible 208/230/416/440 volt transformer, motor starter with overload protection and NEMA 12 weather proof enclosure. II. All components are to be U.L. labelled. III. The use of limiting switches and/or relays shall not be acceptable. F. Photo Sensor I. The compactor shall be fitted with a reliable photo electric sensor II. with delayed start up. III. Wiring to the control panel to be in Sealtite or liquid tight connectors & plastic coated sealed conduit. G. Control Panel I. The control panel shall be mounted to the remote power pack and II. shall include a LCD control panel for: manual forward/reverse switch, emergency stop/reset button, faulty sensor light, 80% full, 100% full indicator, control Optional Odor Control System and Optional Fire Panel Monitoring hook up. H. Programmable Controller Page 3

I. The compactor shall be controlled and monitored by a microprocessor II. which shall visually allow the user to read the various operations of the compactor. III. LCD screen will display operations & shall include: photo eye fault, pressure switch failure, overload fault, 80% and 100% full. I. Automatic Shut Off Control I. Compactor door shall be fitted with a magnetic proximity switch to shut the machine down when the access door is opened. II. The compactor shall also shut down after 15 minutes of continuous III. operation indicating possible photo sensor malfunction. J. Performance I. Compactor shall displace not less than 30 cu. yd.of material per hour II. with a cycle time not to exceed 35 seconds. III. A ram face pressure of 51 psi shall insure a total packing force of IV.27,700 lbs. K. Container I. Compactor provider shall furnish two (2 each) 2 cu. yd. Containers per compactor Part 3 EXECUTION 3.1 INSPECTION A. Inspect the areas and conditions under which units are to be installed. Do not proceed with the work until conditions are satisfactory. 3.2 INSTALLATION A. General I. Compactor is to be installed in accordance with approved drawings. B. Field Assembly Work I. Perform minor field assembly work to install certain fragile or projecting II. parts that were not installed at the factory. C. Set, Level and Align I. Set each component of work securely and accurately, level and properly II. aligned with other components and other work. D. Anchorage I. Drill foundation, furnish and install ¾ drop in anchors to secure the compactor legs. E. Motor Rotation I. Check that the motor rotates in the clockwise direction when engaged. 3.3 TESTING AND INSTRUCTIONS Page 4

A. Test each item of operational equipment. Provide maintenance manual. Instruct Owner s operation personnel in proper use, operation and maintenance of equipment. 3.4 MAINTENANCE A. Semi-annually, oil reservoir should be drained and filled with new hydraulic fluid; photo sensor should be cleaned; and hydraulic fittings should be tightened. Part 3 ACCESSORIES 4.1 OPTIONAL ADD-ONS A. Ben F. Perry Co., Inc. Air Solution Control Unit: Deodorizer unit placed in trash room that eliminates odor and is provided with one year supply of solution. * END OF SECTION * Page 5