70E Pressure Booster. Bell & Gossett. Bulletin D-215D. Efficient Operation. Easy to Select and Install. Quick Set-up through EZ Start

Similar documents
Soft Start Series MP700 Solid State, Reduced Voltage

Across-the-Line SERIES MP300 Combined Manual and Automatic

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

Variable Frequency Drive SERIES MP800 VFD

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

SECTION PACKAGED HEAT TRANSFER SYSTEM

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Drawing Submittal Package

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

FTA550 JOCKEY PUMP CONTROLLERS

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

opti-visor ultra-efficient chiller plant automation Typical specification

Spectron LSN (Life Safety Network) Suggested Specifications

LMR Electric Fire Pump Controllers Features

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Construction Electrical

LMR Electric Fire Pump Controllers Features

Drawing Submittal Package

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

SECTION PLUMBING EQUIPMENT

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

SECTION PLUMBING EQUIPMENT

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

DIESEL Engine Fire Pump Controllers Features

SECTION ROTARY-SCREW WATER CHILLERS

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Transfer Switch Features

DGC-1000 DIGITAL GENSET CONTROLLER

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

FDF Foam Pump Controllers Features

Centro-Matic Automated Lubrication Systems System Controls

CTO BOOSTER SPECIFICATION

DGC-500 DIGITAL GENSET CONTROLLER

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Transfer Switch Features

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Hydroflo Prepackaged Pumping Systems

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Technical Data Submittal Document

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Med Touch Master Alarm

ULTRA-SAFE Explosion-proof Duct Heaters

New Versa IC Platform

RTD TEMPERATURE SENSING SYSTEM

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

.2 Section Waste Management and Disposal.

Tri-Tech Medical Inc.

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

Power Flame Incorporated

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

Control and power circuit fusing to meet N.E.C.

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

INVITATION TO TENDER ITT NO. PS KILLARNEY COMMUNITY CENTRE ENERGY UPGRADE ADDENDUM NO. 2

Domestic Pump Condensate Transfer Equipment

Med Touch Combination Alarm Conversion Kits

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Lift Station Level Controller

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Sequence of operation

Integrated Automation Instrumentation & Terminal Devices

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

DIESEL Engine Fire Pump Controllers Features

I/A Series 716C 1/16 DIN Temperature Controller

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

PACKAGED AIR COOLED Product Data Catalog

SECTION FIRE PUMPS 1.00 PART 1 & GENERAL Description of Work. A. Provide pumps for fire suppression Section Includes

Industrial Grade Gas Detection Detecting The Difference

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent

ULTRA-SAFE Explosion-proof Duct Heaters

Guide Specification Model CTG Automatic Transfer Switch

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

Cutting Edge Compressor Technology

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

Transcription:

Bell & Gossett Bulletin D-215D 70E Pressure Booster Efficient Operation Easy to Select and Install Quick Set-up through EZ Start Serial Communication Economical Configuration Bell & Gossett Excellence Packaged Systems Group

Microprocessor Control Panel Exclusive Bell & Gossett Design Internal Diagnostics Differential Temperature No Flow Shut Down Automatic or Manual Operation NEMA 1 Enclosure UL listed cul or CSA Certified IEC Magnetic Starters with Integral Overload Protection Fuses for Short Circuit Protection User-Friendly Operator Interface User Selectable Pump Staging Methods: -kw (True Power) -Amps (RMS) -Flow (GPM) (flow sensor required) -Pressure (PSI) EZ Start through Quick Setup Parameter Backup through Save and Load Menu On-screen Help Function On-line Diagnostics Log Menu Visual Alarm Messages -High and Low Suction Pressure Alarms -High and Low System Pressure Alarms -High Temperature Alarm -Overload Failure Alarm Manual or Automatic Pump Alternation Pump Exercise Feature kw and Amp Transducer with On-Board Calibration Real Time Clock Scheduled Start/Stop of System Elapsed Time Meters Suction and Discharge Pressure Displays Virtual H-O-A Switches Energy Management System Interface Hardwire Communication: Pump Run Indication Start/Stop Digital Input Alarm Indication System Auto/Manual Indication Serial Communication: Above points plus Pressure, Temperature and Power Measurement System Flow - with Optional Flow Meter Pump Alternation No Flow Shut Down Status Optional Features NEMA 4 or 12 Enclosure Low Level Cutout with Alarm (used when drawing from a tank) High Level Cutout (used when filling a tank) Differential Pressure switches (for pump failure indication) Flow Meter (for staging to flow or for gpm display) NEMA Starters Short Circuit Protection for Each Pump via Circuit Breakers Audible Alarm Flow Switch No Flow Shutdown Phase Monitoring Pressure Switch (for redundant low suction cutoff) Factory Assembled Pressure Booster System Bell & Gossett Series 1531 Pumps Copper Headers with choice of end cap locations Cla-Val Pressure Reducing Valves Thermal Relief Mechanism Pump/PRV Isolation Valves ISO 9001 Certified Facility UL Listed Pumping System

Step 1 Step 2 70E's Three-Step Selection Process System Demand: GPM 0-215 = 3" Up to 375 = 4" Up to 835 = 6" Required Pump Total Dynamic Head 1. System Discharge Pressure Required: psig x 2.31 = ft (A) 2. Pump Package Pressure Drop: 2.2 psig x 2.31 = 4.62 ft (B) 3. PRV Pressure Drop (see Chart A): Pump Flow GPM psig x 2.31 = ft (C) (Chart A) 100 90 80 70 60 50 40 GLOBE TYPE SIZES 1 1 /2" 2" 2 1 /2" 3" Chart A PRV Pressure Drop 30 20 10 98 PRESSURE DROP - PSI 7 6 5 4 3 2 1 20 30 40 60 70 8090 200 2000 50 100 500 1000 FLOW RATE - GALLONS PER MINUTE (WATER) 4. Suction Pressure from City Supply or Tank* psig x 2.31 = ft (D) *Note NPSH requirement of final pumps selected. Required Pump Total Dynamic Head = A + B + C - D = ft + ft + ft - ft = ft (TDH) Step 3 Use the ESP-Plus Pump Selection program or Bell & Gossett published pump curves to select pumps. If you cannot find a model number to fit your application, call your local Bell & Gossett representative for a booster that will fit.

70E 2-PUMP DIMENSIONS MODEL # (see back cover) A (max) B (max) 21A, 2AA, 2KF, 2KG, 2RF, 2RG 51.13" 48.50" 22A, 22E, 29A, 29E, 2BA, 2BE 51.13" 54.00" 22B, 2BB, 2PA, 2PE 51.13" 54.00" 2JE, 2KF, 2QF, 2RF 51.38" 48.50" 23B, 23C, 23H, 2CB, 2CC, 2CH 51.38" 46.75" 24C, 24D, 24J, 2DC, 2DD, 2DJ 51.13" 48.38" 25A, 2EA 52.13" 54.75" 26B, 2FB, 2LA, 2LE, 2SA, 2SE 53.38" 56.63" 2ME, 2MF, 2TE, 2TF 52.50" 54.75" 2NF, 2NG, 2UF, 2UG 52.63" 54.75" 26A, 26E, 2FA, 2FE 53.75" 56.63" 27B, 27C, 27H, 2GB, 2GC, 2GH 52.50" 49.88" 28C, 28D, 28J, 2HC, 2HD, 2HJ 52.63" 49.25" *C dimension is no greater than 36" for motor frame sizes of 284JP or less. 59.50" A B C 70E 3-PUMP DIMENSIONS MODEL # (see back cover) A (max) B (max) 31A, 3AA 73.13" 48.50" 32A, 32B, 32E, 3BA, 3BB, 3BE, 39A, 39E 73.25" 54.00" 3PA, 3PE 73.25" 54.00" 3JE, 3JF, 3KF, 3KG, 3QE, 3QF, 3RF, 3RG 73.38" 48.50" 33B, 33C, 33H, 3CB, 3CC, 3CH 73.38" 46.63" 34C, 34D, 34J, 3DC, 3DD, 3DJ 73.38" 48.38" 35A, 3EA 74.13" 54.75" 36A, 36B, 36E, 3FA, 3FB, 3FE, 3LA, 3LE 74.38" 56.63" 3SA, 3SE 74.38" 56.63" 3ME, 3MF, 3NF, 3NG, 3TE, 3TF, 3UF, 3UG 74.50" 54.75" 37B, 37C, 37H, 38C, 38D, 38J, 3GB, 3GC 74.50" 49.88" 3GH, 3HC, 3HD, 3HJ 74.50" 49.88" *C dimension is no greater than 36" for motor frame sizes of 284JP or less. 59.50" A B C

SUGGESTED SPECIFICATION FOR THE 70E PRESSURE BOOSTER Furnish and install where shown on the drawings 70E Pressure Booster System(s) Model number as manufactured by ITT Bell & Gossett. The electrical service to be provided shall be: Volts Hertz Phase. Each unit shall have the capacity of GPM at a discharge pressure of psig when supplied with a minimum suction pressure of psig. Pumps shall have the following duty points: (1) GPM @ TDH w/ HP, RPM (2) GPM @ TDH w/ HP, RPM (3) GPM @ TDH w/ HP, RPM The unit shall be constructed with copper headers type L. Unit shall be rated for 150 psig working pressure. Headers shall be constructed to be easily removed to allow for service access and moving the unit through doorways. The unit shall be complete with Bell & Gossett Series 1531 horizontally mounted bronze fitted pumps. Pumps shall be rated for a minimum of 175 psig working pressure. Casings shall have gauge ports and vent and drain ports at top and bottom of casing. Motors shall meet NEMA specifications and shall be of the size, voltage,and enclosure called for on the plans. The pump manufacturer will be one in the same as the pressure booster manufacturer to ensure single source unit responsibility. The manufacturer will have in place a quality assurance program and shall be ISO 9001 certified. The manufacturer shall be in the business of manufacturing pressure boosters for a minimum of 30 years and shall have a minimum product liability insurance of $5,000,000 per occurrence. Proof of certification and insurance shall be provided at time of submittal. Entire package shall be constructed to UL Category QCZL Packaged Pumping Systems and listed by UL or equal prior to shipment. A globe pattern, in-line combination pressure reducing (PRV) and check valve assembly shall be installed on each pump discharge. The valve shall have an epoxy coated body with a bronze disc. The valve pilot shall be direct acting, adjustable, spring-loaded, normally open diaphragm valve. Isolation valves shall be provided for each pump/prv set. Pumps shall be protected from thermal buildup, when running at noflow, by a common thermal relief mechanism. The Technologic solid state, programmable, constant speed pump logic controller shall be provided by ITT Bell & Gossett. The controller shall be specifically designed for constant speed pressure boosting applications. The controller shall be function to a proven program that safeguards against potentially damaging electrical and hydraulic conditions including: motor overload low level low and high suction pressure no flow low and high system pressure pump failure high system temperature The entire pump logic controller assembly shall be listed and bear the label of a nationally recognized test lab. The pump logic controller shall be listed and bear the label of Underwriters Laboratories (UL), cul or CSA. The Pump logic controller shall be microcomputer based and hold its software in non-volatile memory. On-line field modified data entries, such as stage point, or method of staging, shall be stored in flash memory with capbility to prevent accidental loss of data due to voltage surge or spike. In the event of a complete power outage, all factory preset data values remain stored and available for recall by the operator. The pump logic controller shall be powered by 115V AC power from the control power transformer within the control enclosure. The control panel shall be equipped with a regulated 24VDC power supply to power analog input signals. The Pump logic Controller shall be capable of receiving four 4-20 ma analog input signals and two RTD signals. The staging of pumps shall be user-selectable based on kilowatts (kw), current (Amps), flow (GPM) or pressure (PSI). kw shall be true power derived from a B&G transducer. Amps shall be RMS from the kw transducer. Both kw and Amps shall be microcontroller calibrated with calibration held in non-volatile memory. PSI shall be derived from a B&G supplied pressure transducer with a 4-20 ma analog input. Optional flow shall be derived from a B&G supplied and calibrated transducer with a 4-20 ma analog input. The control enclosure shall conform to NEMA 1 requirements and it shall include motor starters, overloads, control power transformer and microprocessor with NEMA 4 rated operator interface. The pump logic controller shall alternate the pumps automatically based on a user defined time period, scheduled, manually from the operator interface, or via serial interface. The Technologic controller shall have off line and on line diagnostic software. Off line diagnostics shall consist of CPU, non-volatile and RAM memory test. The controller shall have digital input diagnostics, display test, and analog and digital I/O user tests. Fault information may be accessed by interrogating the pump logic controller through its HELP and log keys. A data-logging feature provides historical information of key events with date and time stamps. Log information includes alarms, pump run timers, system on/off times, and pump cycle counters. The data log displays the minimum, maximum and average values of temperature, pressure and flow. It is also capable of displaying kilowatt-hours. The pump logic controller shall be powered by 115V/1Ph/60Hz or 50 Hz power. The incoming power and I/O circuitry shall reject electromagnetic (EMI) and radio frequency interference (RFI). All digital outputs shall be externally isolated. The pump controller shall be capable of operation in ambient conditions of 0 C to +50 C and a humidity range of 10% to 90%, non-condensing. All external sensors/transmitters and switches shall be powered by the pump logic controller through its integral 24VDC power supply. Overvoltage protection shall be on-board. All analog inputs shall be provided with current limit circuitry to provide short circuit protection and safeguard against incorrect wiring of sensors. The pump logic controller shall operate the pump(s) in a pre-determined manner as indicated in the Sequence of Operation. The controller's user interface shall contain a 4 line x 20 character liquid crystal display with 1/4" characters. The pump logic controller shall be capable of operating in automatic, manual or off-line diagnostic modes. One level of password and software security shall be provided for protection of field modifiable data. The pump controller shall be capable of communicating with the Building Automation System (BAS) by both hardwired and serial communications. The following communication features shall be provided to the BAS in hardwired form via digital outputs: Remote system start/stop input System alarm output Pump on/off status indication Auto/manual status indication The following communication features shall be provided to the Building Automation System via an RS-485 port utilizing BACnet MS/TP, Johnson Controls Metasys N2, or Modicon Modbus protocols. LonWorks shall be provided through RS-232 port. 1. Individual analog inputs 2. Individual pump failure 3. Individual pump on/off status 4. Start/Stop command and status 5. System flow when optional flow sensor is provided 6. Pressure, Temperature, Power measurement 7. General alarm indication 8. No flow shutdown status 9. Pump alternation The pump logic controller shall provide the following standard userselectable features: low suction pressure alarm and cut out high suction pressure alarm and cut out low system pressure alarm high system pressure alarm and cut out visual alarm messages no-flow shut down pump failure alarm high temperature alarm and cut out low level alarm and cut out overload failure alarm automatic or manual alternation

70E MODEL NUMBER IDENTIFICATION 2 1 A 05 B A 3 NUMBER PUMP PUMP PRV HORSE- VOLTAGE CAP LOCATION HEADER (facing front of panel) OF SIZE SIZE SIZE POWER SIZE PUMPS 1750 3500 (2) or (3) (A) 1 1 /4AC 05 = 5HP (B) 1 1 /2AB 07 = 7 1 /2 (C) 2AC 10 = 10 (D) 2 1 /2AB 15 = 15 (E) 1 1 /4BC 20 = 20 (F) 1 1 /2BC 25 = 25 (G) 2BC 30 = 30 (H) 2 1 /2BB 40 = 40 (P) 1 1 /4AC lead, 1 1 /2AB lag (1) 1 1 /4AC (Q) 1 1 /4AC lead, 2AC lag (2) 1 1 /2AB (R) 1 1 /4AC lead, 2 1 /2AB lag (3) 2AC (S) 1 1 /4BC lead, 1 1 /2BC lag (4) 2 1 /2AB (T) 1 1 /4BC lead, 2BC lag (5) 1 1 /4BC (U) 1 1 /4BC lead, 2 1 /2BB lag (6) 1 1 /2BC (7) 2BC (8) 2 1 /2BB (A) 1 1 /2" (9) 1 1 /4AC lead, 1 1 /2AB lag (B) 2" (J) 1 1 /4AC lead, 2AC lag (C) 2 1 /2" (K) 1 1 /4AC lead, 2 1 /2AB lag (D) 3" (L) 1 1 /4BC lead, 1 1 /2BC lag (E) 1 1 /2" lead, 2" lag (M) 1 1 /4BC lead, 2BC lag (F) 1 1 /2" lead, 2 1 /2" lag (N) 1 1 /4BC lead, 2 1 /2BB lag (G) 1 1 /2" lead, 3" lag (H) 2" lead, 2 1 /2" lag (J) 2 1 /2" lead, 3" lag (A) 200-208/60/3 (B) 230/60/3 (C) 460-480/60/3 (D) 575/60/3 (E) 380/50/3 (F) 460/50/3 (A) Both right (B) Both left (C) Suction left, Discharge right (D) Suction right Discharge left 3 = 3" 4 = 4" 6 = 6" COPYRIGHT 2008 BY ITT CORPORATION PRINTED IN U.S.A. 3-08 THE ITT ENGINEERED BLOCKS SYMBOL AND ENGINEERED FOR LIFE ARE REGISTERED TRADEMARKS OF ITT CORPORATION ITT 8200 N. Austin Avenue Morton Grove, IL 60053 Phone: (847) 966-3700 Fax: (847) 966-9052 www.bellgossett.com CANADA ITT R&CW Canada 55 Royal Road Guelph, Ontario, N1H 1T1, Canada Phone: (519) 821-1900 www.ittfpc.ca