MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Similar documents
Gagnez avec «David» Mighty MEPS contre les cartouches «Goliath» SPE

300 series HPLC autosamplers

Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Rapid Quantification of Polar and Semipolar Pesticide Metabolites with Combined Online SPE and Direct Injection

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

Direct Injection and Online SPE LC/MS/MS for the Determination of Pharmaceuticals and Personal Care Products (PPCPs) in Water Samples

How Important is Performance to your SPE Method Development?

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

Fundamentals of Solid-Phase Extraction (SPE): Principles and Practical Tips for Developing Sample Preparation Methods

Application Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

Thermo Scientific Dionex SolEx SPE Cartridges

On Line SPE LC/MS/MS Applications

Spark Holland introduces

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

Automated Fractionation System that Increases Recovery and Optimize Precision of Solid Phase Extraction Methodology

Application Note. Authors. Abstract

Sample Preparation Solid Phase Extraction Disks Cartridges. Horizon Technology, Inc. Salem, NH USA

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

Sensitive Determination of Microcystins from Environmental Waters Using On-Line SPE

Purge and Trap Troubleshooting Made Easy?

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

AppNote 3/2009. Automation of Solid Phase Extraction Methods using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

Solid Phase Extraction (SPE) for the Analysis of Semivolatile. According to EPA Method 625. Derick Lucas, PhD R&D Sample Preparation Chemist

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Auto SPE-06Plus Solid Phase Extraction System. Reeko Instrument USA

Supra-Clean and Supra-Poly SPE Solutions. Solid Phase Extraction Columns

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Reliable elimination of particles and micro organisms PAGE Protein Precipitation Fast and effective sample clean up of biological samples

An Automated SPE Procedure and Analysis for the Extraction of Chlorpromazine and Thioridazine from Plasma Application Note 213

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

Chromatography. Research Supplies. 2014/2015 Catalog

Pretreatments to LLE

SCION 436-GC. Dimensions and Weights

An Automated Method for the Selective Solid Phase Extraction of Ochratoxin A from Wheat Using Molecularly Imprinted Polymers

Online SPE-UHPLC-MS. CHRONOS for Control & System Integration. Flexible autosampler for sample preparation. Superior UHPLC system for analysis

DETERMINATION OF PAH In Particulate Matter PM10 With SPE/EVAporation

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

Customised HPLC Systems for Highest Performance

Scaled Down EPA Methods 8270 and 625 Solid Phase Extraction of 100 ml Samples or Less

FREESTYLE SPE UNIQUE POSSIBILITIES FOR SOLID PHASE EXTRACTION

General Animal Injections

MultiPurpose Sampler MPS robotic series

Methods of solid phase extraction. Methods of solid phase extraction

XENOSEP. SPE Systems for EPA Method 1664A. The Easiest, Most Cost Effective Way to Increase Productivity

TYPES AND APPROPRIATE INJECTORS

CALIDUS tm the Modular micro Gas Chromatograph

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

Use of Automation to Achieve

APPLICATION NOTEBOOK FOR AFFINIMIP SPE

An Advanced Heat Exchanger for the Agilent 1290 Infinity Thermostatted Column Compartment

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

Biotage VacMaster 10 & 20 Sample Processing Station. Operation Manual

IMPROVING THE QUANTITATIVE REPRODUCIBILITY OF AN ATMOSPHERIC PRESSURE CHEMICAL IONISATION SOURCE FOR GC/MS AND GC MS/MS ANALYSIS

New Designs and Formats in Solid-Phase Extraction Sample Preparation

GC Injectors. GC Injectors

Tool-free LC connections for HPLC, UHPLC and nano LC systems

Agilent 1290 Infinity II Vialsampler Data Sheet

This document is a preview generated by EVS

PURITY GRADES OF LAB REAGENTS

detectors UltiMate 3000 Variable Wavelength Detectors

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

FREESTYLE always ready

SPME-FFA Field Sampler

Installing the Agilent CE ESI-MS Sprayer Kit (G1607A)

JSB is an authorised partner of DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. i n s p i r a t i o n m e e t s i n n o v a t i o n!

DYE QUALITY CONTROL REFERENCE MATERIAL KIT

Order all the parts and accessories needed at one time Reduced learning curve for rapid implementation

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014

APPLICATION NOTE DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. APPLICATION NOTE As of July 2017, Version: 1.

Agilent InfinityLab Online SPE Solution

Agilent GC Sampler 80/120 SPME Option

Aromatics and Oxygenates in Gasoline June2018

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

Sample Prep Perspectives

Systems. Visit us at

INJECTORS Purge & Trap General Operating Procedures continued

Use of Automation to Achieve High Performance SPE

SEC-MALS Noise Assessment and Cleaning Guide

WELCOME TO ELLUTIA CHROMATOGRAPHY SOLUTIONS

The KingFisher Family

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

FIXED GAS ANALYZER (FGA)

Agilent 1290 Infinity II Online SPE Solution

Typical Sample Preparation Process & Highlighted Areas for Horizon Technology SmartPrep Extractor Automation and XcelVap Evaporation

Nexera-i Specifications Prominence-i Specifications

Tekmar-DOHRMANN The 3100 Sample Concentrator From ManualLib.com

APPLICATION NOTEBOOK FOR SOLID PHASE EXTRACTION

RESOLUTION OIV-OENO MONOGRAPH ON TANNINS UPDATE OF THE METHOD FOR DETERMINATION OF POLYPHENOLS

HISTORY OF VARIAN CAPILLARY INJECTORS

FREESTYLE QUATTRO ACCECLEAN ELUVAC GPC COLUMNS IMMUNOAFFINITY COLUMNS SAMPLE SAMPLE PREPARATION PRODUCTS PREP

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

Introduction to the Fusion TOC Analyzer

SmartPrep Automated SPE Cartridge Extractor II Module

[ ACQUITY QDa DETECTOR ] SEPARATING BEYOND QUESTION BRINGING THE POWER OF MASS DETECTION TO YOU

Universal NanoFlow Sprayer Installation and Maintenance Guide

Transcription:

- Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples from hours to minutes Eliminate all extra steps between sample preparation and sample injection Reduce buffer and solvent volume from milliliters to microliters Reduce the sample volume needed to as little as 10 µl PATENT PENDING AUSTRALIA & PACIFIC REGION CHINA EUROPE INDIA JAPAN MIDDLE EAST USA

What is? is Micro Extraction by Packed Sorbent and is a new development in the fields of sample preparation and sample handling. is the miniaturization of conventional SPE packed bed devices from milliliter bed volumes to microliter volumes. The approach to sample preparation is suitable for reversed phases, normal phases, mixed mode or ion exchange chemistries. is available in a variety of common SPE phases. The Barrel Insert and Needle Assembly (BIN), (Patent Pending) contains the stationary phase, and is built into the syringe needle (Figure 1). FIGURE 1 Schematic of the BIN in the syringe needle. Why use? Historically, many sample preparation methods used liquid-liquid extraction (LLE) which required large volumes of sample, solvents and time. The advantages of SPE over LLE are that SPE takes much less time, can be developed into a fully automated technique, requires much less solvent and offers selectivity. performs the same functions as SPE the removal of interfering matrix components and the selective isolation and concentration of analytes. increases the advantages of conventional SPE in the following ways: Significantly reduces the time needed to prepare and inject samples. Can be combined with LC or GC automation - the extraction step and injection step are performed on-line using the same syringe. Significantly reduces the volume of solvents needed. Ability to work with samples as small as 10 µl versus several hundred µl for SPE. Sample Size and Sensitivity Sample volumes may be as little as 10 µl, or by taking multiple aliquots of 100 µl or 250 µl, samples of 1 ml or larger may be concentrated. Automation The capability to extract samples and make injections on-line using a single device reduces both sample processing times and the need for operator intervention. Sorbent Life Typical BIN life for extraction of whole plasma sample is conservatively about 40 to 100 samples. This significantly increases for cleaner samples. Carry Over The small quantity of phase in the BIN can be easily and effectively washed between samples to reduce the possibility of carryover. This washing process is simply not practical with off-line SPE devices. With automation of washing can occur while the previous sample is running. Flexible and Easy to Use The dimensions of the sorbent bed ensure that the performance remains identical to conventional SPE devices when used for extraction of similar samples. BINS can be used for sample volumes as small as 3.6 µl making them particularly well suited to on-line use with LC-MS analysis of volume limited samples.

How to use Step 1: Pump the sample through the BIN (one or more volumes may be taken). STEP 1 STEP 2 STEP 3 STEP 4 Step 2: Wash the BIN once by pumping 20 µl to 50 µl of wash solution through the BIN to remove interferences. Step 3: Elute the analyte by drawing solvent through the BIN into the syringe barrel. Step 4: Inject the analyte directly into the injector. Pump 50 µl solvent followed by 50 µl wash solution to prepare BIN for the next sample. SAMPLING (1-N TIMES) WASHING ELUTION SOLVENT INJECTION FIGURE 2 When the sorbent is exhausted, or another phase is required, the BIN is easily exchanged by simply unscrewing the locking nut and removing / replacing the BIN. The BIN is easily installed into the syringe housing and then secured by the locking nut. Individual labeling of each BIN insures the use of the correct stationary phase for each extraction. Can Be Semi or Fully Automated Semi-automation of can be achieved by coupling syringes to SGE s evol digital analytical syringe to speed up repetitive SPE and is ideal for rapid method development. For more information on evol ask your local SGE office. can also be fully automated by using XCHANGE syringes on autosamplers such as the CTC PAL for on-line SPE and injection. : MICRO EXTRACTION BY PACKED SORBENT

How Does Perform? Sample preparation for complex biological samples is readily adapted to and reduces the volumes of sample and reagents required for extraction when compared with conventional SPE and other micro extraction procedures. The extraction of xanthine metabolites from raw human urine using a BIN packed with C18, prior to GC-MS analysis, is shown in Figure 3 and the extraction of anesthetics from rat plasma using a BIN packed with C2, prior to LC-MS analysis is shown in Figure 4. ABUNDANCE EXTRACTION FROM RAW URINE THEOPHYLLINE / PARAXANTHINE RETENTION TIME (MINUTES) THEOBROMINE CAFFEINE FIGURE 3 Difficult matrices such as human urine are easily processed using. In this example 100 µl of human urine was aspirated through a C18 BIN (conditioned with methanol and water, water wash). Bound xanthines were eluted with 30 µl methanol, 2 µl injected on a BPX5 column for GC-MS analysis. LIDOCAINE (2.4 µmol/l) EXTRACTION FROM PLASMA ROPIVACAINE (2.5 µmol/l) 2.18 3.29 BUPIVACAINE (3 µmol/l) 5.17 FIGURE 4 Local anesthetics were spiked into rat plasma samples - final concentrations: Lidocaine 2.4 µmol/l, Ropivacaine 2.5 µmol/l and Bupivacaine 3.0 µmol/l. 50 µl of the spiked plasma was aspirated through a C2 BIN, washed with water and eluted using 0.1% HCOOH in 25% Acetonitrile + 75% water onto a C18, 100 X 2.1 mm column. 1 2 3 4 5 6 7 8 9 10 RETENTION TIME (MINUTES)

How Does compare? Accuracy and Precision Table 3 summarizes the precision and accuracy results obtained analyzing Ropivacaine by four sample preparation methods:, Liquid-Liquid Extraction (LLE), conventional SPE and Solid Phase Microextraction (SPME). Compared to SPME, also a µspe technique, demonstrated better precision and accuracy while taking significantly less time to process each sample. Table 4 compares the accuracy, precision, limits of detection and extraction time of with two other µspe techniques, SPME and SBSE (Stirring Bar Sorbent Extraction) for 5 different PAH s extracted from water. The results from the and SBSE techniques are significantly better than SPME but processes each sample 100 times faster than SBSE. TABLE 3 : Comparison of accuracy and precision between and other methods for ropivacaine (local anesthetics) Method Ropivacaine Accuracy Precision (RSD%) Handling time LOD (nm) (%) (Inter-assay) [1] / GC-MS 2 105 5.0 1 min [2] LLE / GC-MS 2 101 3.8 20 min [3] SPE / LC-UV 100 101 3.0 20 min [4] SPME / GC-MS 5 110 6.3 40 min M. Abdel-Rehim / J. of Chromatography B, 801 (2004) 317-321 TABLE 4 : Comparison of accuracy and precision of, SPME and SBSE for the analysis of PAH s in water. Compound Accuracy Precision RSD Limit of detection Extraction time (%) (%) (ng/l) (min) SPME SBSE SPME SBSE SPME SBSE SPME SBSE Anthracene 84 81 99 12 3 6 5 100 1.2 2 30 200 Chrysene 107 81 100 1 4 5 5 90 0.2 2 30 200 Fluoranthene 100 84 100 9 4 4 5 100 1.2 2 30 200 Fluorene 103 96 97 5 5 4 1 40 0.7 2 30 200 Pyrene 115 86 100 7 3 3 1 40 0.7 2 30 200 M. Abdel-Rehim / J. Chromatog. A 1114 (2006) 234-238 Meps Syringe Options All syringes may be used manually as well as with the listed autosamplers Description # per Part Replacement Pack Number Plunger 100 µl Removable needle MEPS syringe for CTC Analytics, HTA 300A Plus & Varian 8400 systems 1 005291 031826 250 µl Removable needle MEPS syringe for CTC Analytics, HTA 300A Plus & Varian 8400 systems 1 006291 031831 250 µl Removable needle MEPS syringe for CTC Analytics systems 1 006292 031831 100 µl Removable needle MEPS syringe for Agilent systems 1 005292 0318263 250 µl Removable needle MEPS syringe for Agilent systems 1 006293 0318303 100 µl Removable needle MEPS XCHANGE syringe for CTC PAL-xt 1 2928500 2930580 250 µl Removable needle MEPS XCHANGE syringe for CTC PAL-xt 1 2928600 2930680

Is there significant carry over using? Devices used for SPE are traditionally considered to be single use. The precision engineering used in the design and manufacture of allows for simple wash steps and consequently the re-use of the device. To demonstrate this we extracted phenols from waste water and measured the carry over between experiments. TIC 220000 2.4-dichlorophenol 2.4-dimethyphenol 2-chlorophenol phenol 4-chloro-3-methylphenol 2.4.6-trichlorophenol 3 5 7 9 11 13 RETENTION TIME (MINUTES) Phenols 25ppb Extraction 2 Extraction 3 Figure 5 shows the chromatograms for the three 10 µl extractions. The first is labeled phenols 25 ppb, the second is extraction 2, and the third extraction 3. Clearly all of the phenols were eluted in the first 10 µl of Methanol used. One of the most often stated reasons for the use of disposable SPE BINS is the issue of carry over. Results from 5 studies are summarized in Table 1. Utilizing a series of washes using eluent and then wash solution the carry over was virtually eliminated. With a cycle time measured in seconds for this washing takes less than 5 minutes. To accomplish the same for conventional SPE takes an hour or more and uses significant amounts of solvents. Summary Table 2 summarizes the comparison of, SPME and conventional SPE. requires much less time than either SPE or SPME, and shows much better recovery and sensitivity than SPME. also eliminates any intermediate steps between the sample preparation steps and the injection into a GC or LC system. FIGURE 5 Phenols at 25 ppb in alkane contaminated water. 10 x 100 µl cycles on C18 BIN (conditioned with methanol and water). Sample was eluted with methanol 10 µl, 2 µl injected onto a BPX5 column and analyzed by GC-MS. TABLE 1 : Comparison of carryover and wash regime. Wash volume (ul) # of washes and Carry-over Source wash solution PAH s in water 50 µl 4X methanol, 5X water 0.2% - 1% M. Abdel-Rehim / J. Chromatog. A 1114 (2006) 234-238 Anesthetics in 50 µl 4X methanol, 4X water ~ 0.2% (I.S.) M. Abdel-Rehim / J. Human Serum of Chromatography B, 801 (2004) 317-321 Roscovitine in 50 µl 5X methanol/water (95:5, v/v), <0.1% M. Abdel-Rehim / J. plasma and urine 5X water/methanol (90:10, v/v) of Chromatography B, 817 (2005) 303-307\ Roscovitine in 50 µl 4X methanol, 4X water <0.01% M. Abdel-Rehim / J. Human plasma Mass Spectrom. 204;39:1488-1493 Olomoucine in 50 µl 5X methanol/water (95:5, v/v), <0.1% M. Abdel-Rehim et al. / Human plasma 5X water/methanol (90:10, v/v) Analytica Chimica Acta 2005 TABLE 2 : Comparison of BINs, SPME and conventional SPE. Factor BIN SPE SPME Amount sorbent 0.5-2 mg 50-2000 mg thickness 150 mm Sample prep. time 1-2 min 10-15 min 10-40 min BIN use 40 to 100 extractions once 50-70 extractions Recoveries good good low Sensitivity good good low M. Abdel-Rehim / J. of Chromatography B, 801 (2004) 317-321 : MICRO EXTRACTION BY PACKED SORBENT

Barrel Insert and Needle Assembly Options For GC applications, needle is 23 gauge, 0.63mm OD, Cone point style Phase Description For use with # per Part Syringe, P/N Pack Number C18 BIN for Agilent 7693A 005292 and 006293 5 2900601 Silica BIN for Agilent 7693A 005292 and 006293 5 2900602 C8+SCX* BIN for Agilent 7693A 005292 and 006293 5 2900603 C2 BIN for Agilent 7693A 005292 and 006293 5 2900604 C8 BIN for Agilent 7693A 005292 and 006293 5 2900606 Development Kit for Agilent 7693A 005292 and 006293 5 2900605 C18 BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900101 Silica BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900102 C8+SCX* BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900103 C2 BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900104 C8 BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900106 Development Kit for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900105 C18 BIN for CTC Analytics systems using 250 µl syringes 006292 5 2900301 Silica BIN for CTC Analytics systems using 250 µl syringes 006292 5 2900302 C8+SCX* BIN for CTC Analytics systems using 250 µl syringes 006292 5 2900303 C2 BIN for CTC Analytics systems using 250 µl syringes 006292 5 2900304 C8 BIN for CTC Analytics systems using 250 µl syringes 006292 5 2900306 Development Kit for CTC Analytics systems using 250 µl syringes 006292 5 2900305 For LC Applications, needle is 22 gauge, 0.72mm OD C18 BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900401 Silica BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900402 C8+SCX* BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900403 C2 BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900404 C8 BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900406 SCX BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900408 SAX BIN for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900409 Development Kit for CTC Analytics, HTA 300A Plus & Varian 8400 systems 005291 and 006291 5 2900405 C18 BIN for CTC Analytics systems using 250 µl syringe 006292 5 2900501 Silica BIN for CTC Analytics systems using 250 µl syringe 006292 5 2900502 C8+SCX* BIN for CTC Analytics systems using 250 µl syringe 006292 5 2900503 C2 BIN for CTC Analytics systems using 250 µl syringe 006292 5 2900504 C8 BIN for and CTC Analytics systems 006292 5 2900506 SCX BIN for and CTC Analytics systems 006292 5 2900508 SAX BIN for and CTC Analytics systems 006292 5 2900509 Development Kit for CTC Analytics systems using 250 µl syringes 006292 5 2900505 Base material is silica with mean particle size of 45 µm and pore size of 60Å. *C8+SCX BINS are labelled as M1. For an up to date list of published methods visit www.sge.com/products/meps : MICRO EXTRACTION BY PACKED SORBENT

Comparison Table SPE versus SPE Sample Volume 3 ml 50 µl Time Price Solvents Evaporation Step 10 ml 500 µl Yes Unnecessary BR-0238-M RevM SGE Analytical Science 10/2011 www.sge.com