SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

Similar documents
Standard Specifications

Standard Specifications

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

OIL FILM DETECTOR (Long-distance correspondence Version)

General Specifications

General Specifications

Features. Drop-in type detector

Nexera-i Specifications Prominence-i Specifications

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

Bristol Babcock Oil Content Monitor "oil in water"

SIMRAD GD10PE IR GAS DETECTOR

PUV, PIR and PFO Series BROCHURE

SIMRAD GD10 IR GAS DETECTOR

Dust Concentration Meter

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

CLARITY II TURBIDIMETER

Oil-in-Water Monitoring. for. Marine and Industrial. Applications

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

General Specifications

Zirconia Oxygen Gas Analyzers

IN-SITU ZIRCONIA OXYGEN ANALYZER <HART communication>

PRODUCT SPECIFICATIONS

Mercury Vapor Monitor VM-3000

CMT MANUAL 6. NMC SENSORS

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

General Specifications

Technical Information OUSTF10

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

IN-SITU ZIRCONIA OXYGEN ANALYZER

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

Technical Information OUSTF10

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

APPLIED. OMA-406R Rackmount Process Analyzer

PARTICULATE EMISSION MONITORING

UV I UNIT030W / UV I UNIT055W

Series 5000 Hydrazine Analyzer Model 60002

OMA-300 Process Analyzer

Turbimax CUE21 / CUE22

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

for Drinking Water Systems

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

VM-3000 Mercury Vapor Monitor

Complete Gas Analysis

UV - flame detector dual fuel burners for intermittent burner operations

Temperature Controllers

UV Flame Supervision System

OPTISENS TUR 2000 Technical Datasheet

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Dräger Polytron Pulsar 2 Open Path Gas Detector

Technical Information OUSAF21

Class 1 laser beam sensor safe for your eyes

WASTEWATER Online UV%Transmission Analyzer

Specifications Wavelength Range: 190 nm to 800 nm continuous

Low Temperature Zirconia Oxygen Analyzer

VM-3000 Mercury Vapor Monitor

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Ronan Model X96S Series Weighing System

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

VIQUA is an ISO9001:2008 registered company specializing in the design, manufacture and sale of ultraviolet systems for:

Technical Information OUSAF22

General Specifications

Intelligent ph Converter PH400G. PH400G Intelligent ph Converter. Bulletin 12B7C1-01E.

Dissolved Oxygen Analyzers

IN-SITU ZIRCONIA OXYGEN ANALYZER

Class 1 laser beam sensor safe for your eyes

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Class 1 laser beam sensor safe for your eyes

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

Gas cylinder scale Model GCS-1

Inductive Conductivity

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Technical Information OUSAF44

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

The Commercial LED Lighting Specialist

Installation Instructions

General Specifications

KUBOTA Double suction volute pump

Oil-in-Water Monitoring. for. Marine and Industrial. Applications

Technical Information OUSAF12

BS-1015BSW. WARNING Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.

General Specifications

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Data Sheet. >>AMTAX inter 2

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Series Temperature Controller Instruction Sheet

Turbimax CUE21 / CUE22

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Transcription:

ISO-14001 ISO-9001 SPECIFICATION SHEET ORGANIC POLLUTION MONITOR Model: OPM-410A The Model OPM-410A monitors organic pollution in water from industrial effluent, rivers etc.. The design and construction of this latest model is based on decades of development and field experience. The instrument features a direct-insertion detector that eliminates the need for extractive sample conditioning systems. The instrument provides a reliable, low maintenance solution for organic pollution monitoring. FEATURES Direct insertion detector Extractive sample conditioning system is not required. The direct insertion detector eliminates the need for complex sample conditioning and pump systems, increasing reliability and reducing maintenance requirements. Self-diagnostics. The instrument continuously performs internal checks to ensure correct operation. Compact and lightweight design. Weight of the sensor section has been reduced by 75% (compared to previous model) making handling and installation much simpler. The main instrument frame is made from lightweight FRP (Fibre Reinforced Plastics), which has the additional advantage of being corrosive resistant. Accurate calibration Zero/Span calibration can be accurately performed using the stabilization monitoring function. Automatic temperature correction works with span calibration using standard solutions (potassium hydrogen phthalate). Easy span check Span check can be simply carried out using a built-in optical calibration filter. Wide measurement range and automatic range switching: Absorbance up to 2.5Abs can be measured with manual/automatic range switching (4 ranges available). Accurate turbidity correction Built-in turbidity correction function accurately corrects for the turbidity value. COD conversion output Output signal for UV absorbance minus VIS (visible light) absorbance can be provided as a COD conversion value. Sample extraction version also available By installing the optional sample-receiving tank, the measurement can be performed by extracting sample from the process stream. STANDARD SPECIFICATIONS Product Name Model Measurement Object Measurement Method Measurement Cell Cell Cleaning : Organic pollution monitor (UV instrument) : OPM-410A : Organic pollution in effluent : Dual-wavelength absorptiometry (UV 254nm/visible light 365~435nm continuous measurement) : Immersed parallel cell (6, 10, 25mm) as specified by customer : Automatic cleaning of measurement cell inner wall by a wiper system. Measurement Range : Absorbance 0~0.5/0~1.0/ 0~2.0/0~2.5 (Manual/automatic switching) Ambient Temperature : -5~40 o C Sample Temperature : 0 ~ 45 o C (no freezing) Standard Liquids Zero : Zero calibration water such as distilled water Span : Potassium hydrogen phthalate solution Output signals : Isolated from ground, UV absorbance, UV-VIS absorbance, VIS absorbance or COD conversion value 4~20mA DC (Max. load 600Ω) 0~1V DC (Max. load 100Ω - optional) Other Signals Alarm contact outputs Input Contact Signals Power Requirements Power Consumption : Insufficient sample signal Light source lamp cut-off signal Power cut-off (leakage) signal Sample cut-off signal Under cleaning signal High concentration alarm Range switching signal Instrument failure signal (including lamp degradation, cell window fouling, water leakage, light receiver degraded) Contact rating 30V DC, 0.3A : Cleaning command signal; The signal to start the cleaning program remotely Pulse contact input (Voltage free) when the command is given. Make time 0.1~1sec. Contact rating 30V DC, 0.3A : 100V AC±10%, 50/60Hz (other operating voltages available as options). : Approx. 70VA Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1

Materials Sensor (wetted parts) Measurement cell Drive Transmitter case Construction Transmitter Self-stand frame (opt) Sensor Weight Sensor Transmitter Mounting Sensor Transmitter : Cast SUS316 equivalent : Quartz glass : SUS316, urethane rubber : AD12 (corrosion resistant cast aluminium) : Outdoor installation type (JIS protection class 3); 192(W) x 120(D) x 491(H)mm : 380(W) x 500(D) x 1500(H)mm : Immersion type; 435(H) x170(dia)mm : Approx. 6.8Kg (exclusive of cable weight) : Approx. 7Kg (FRP frame 12Kg) : Special mounting device (windup device) : Self-stand frame (standard) or pole. The pole for mounting should be prepared separately. PERFORMANCE Repeatability Linearity Zero drift Span drift Response rate OPTIONS Modification parts for 10mm cell Modification parts for 6mm cell Modification parts for custom cell Sample conditioning system. RELATED EQUIPMENT Load calculator PRINCIPLE OF OPERATION : Within ±2%FS : Within ±2%FS : Within ±2%FS/week : Within ±2%FS/week : Within 30sec. for 90% response : Use the load calculator CALD-131 when the cumulative load determination is required. Surface Finish : Munsell 5PB 8 /1 Cable Ports Connection Cable Installation : Gland socket for Ø15 cable, 4pcs : Between sensor and transmitter, 1pc (Ø15, standard length 10m, coated with soft PVC) : Free from vibration, impacts and corrosive vapours. Air Inlet : The transmitter case interior can be purged by air. Rc 1 /4 plugged when not in use. Air pressure : 0.02Mpa (0.2Kgf/cm 2 ) The light from a low-voltage mercury lamp, powered by a high stability circuit, passes through the measurement cell, and then through a UV (band pass) filter which allows only the light of wavelength ( =254nm) to pass through and also a VIS (band pass) filter which allows only the light of wavelength ( =365~435nm) to pass through. The wavelengths of light selected by each filter then reach the UV sensor and the VIS sensor and are converted to DC voltages Vuv and Vvis. These voltages are converted to absorbance Auv and Avis by the microprocessor controller. The difference between Auv and Avis ( Auv- Avis) is converted to the output signal by a V/I converter to eliminate the effect of suspended solids. MEASUREMENT SYSTEM DIAGRAM Page 2 Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0

DIMENSIONS Sensor Indicator Transmitter Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 3

INSTALLATION EXAMPLES Installation example of self-stand frame Installation of sampling type installation (optional) Example of immersion type installation Page 4 Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0

Windup device for UV instrument (Standard) Chain hanging system Windup device for UV instrument (2 guide pipes system) Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 5

PRODUCT CODE *1 Line frequencies 50Hz and 60Hz available *2 When a custom line voltage is applied, install a stepdown transformer (model ZP, for 100V AC separately. To be separately procured.) *3 Three different outputs; UV, UV-VIS, VIS or COD conversion value are available. (VIS and COD conversion value are switched of 0.5/1.0/2.0/2.5 absorbances. This function is equipped as a standard. When a load calculator is combined with the monitor, the range of the monitor should be fixed. *4 AUTO means the automatic range switching of 0.5/1.0/2.0/ 2.5 absorbances. This function is equipped as a standard. When a load calculator is combined with the monitor, the range of the monitor should be fixed. *5 The extension cable may be routed up to 30m. *6 Select No frame when the FRP frame is not required. *7 When the sampling type is selected, the windup device and the sample tank (of UV instrument) OPM-410W need not be ordered. *8 Hanging with two 3.5mm chains utilizing the feature of OPM- 410 is recommended as the simplified installation method. (When this method is employed, two eye bolts are supplied with the sensor.) *9 When there is no wall near the guide pipe of windup device, the sensor may be unexpectedly rotated. Select the 2-guide pipe type in such a case. (Spare parts) (Code number) Hanging chain assembly 6140970K Chain stopper 122E164 DKK-TOA CORPORATION Do not operate products before consulting instruction manual. International Operations: DKK-TOA Corporation 29-10, 1-Chome, Takadanobaba, Shinjuku-ku, Tokyo 169-8648 Japan Tel: +81-3-3202-0225 Fax: +81-3-3202-5685 Representative Office (Europe): DKK-TOA European Representative St. Johns Innovation Centre, Cowley Rd., Cambridge CB4 0WS UK. Tel : +44 (0)1223-526471 Fax : +44 (0)1223-709239 http://www.toadkk.co.jp Information and specifications are for a typical system and are subject to change without notice. Page 6 Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0