Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates

Similar documents
Biotage VacMaster 10 & 20 Sample Processing Station. Operation Manual

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Automated Fractionation System that Increases Recovery and Optimize Precision of Solid Phase Extraction Methodology

How Important is Performance to your SPE Method Development?

Methods of solid phase extraction. Methods of solid phase extraction

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

Solvent Evaporation. Fast, Reliable and Affordable

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

An Automated SPE Procedure and Analysis for the Extraction of Chlorpromazine and Thioridazine from Plasma Application Note 213

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

Spark Holland introduces

FREESTYLE SPE UNIQUE POSSIBILITIES FOR SOLID PHASE EXTRACTION

300 series HPLC autosamplers

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

Fundamentals of Solid-Phase Extraction (SPE): Principles and Practical Tips for Developing Sample Preparation Methods

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

Supra-Clean and Supra-Poly SPE Solutions. Solid Phase Extraction Columns

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

Thermo Scientific Dionex SolEx SPE Cartridges

Product Guide for Ludger Clean Post-endoglycosidase and Post-exoglycosidase Clean-up Plate

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

Without the Dry Down. Successful Bioanalytical Sample Preparation. Microelution 96-Well SPE Plates

Agilent Vac Elut SPS 24 Manifold User Guide

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

Systems. Visit us at

Evaporators, Sealers and other Equipment

vwr.com. L a b o r a t o r y P u m p s + S y s t e m s

Reliable elimination of particles and micro organisms PAGE Protein Precipitation Fast and effective sample clean up of biological samples

XENOSEP. SPE Systems for EPA Method 1664A. The Easiest, Most Cost Effective Way to Increase Productivity

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Rapid Quantification of Polar and Semipolar Pesticide Metabolites with Combined Online SPE and Direct Injection

MICROPLATE EVAPORATORS

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

Application Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.

ELISA NIMBUS. Automated ELISA Processing System

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

APPLICATION NOTE DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. APPLICATION NOTE As of July 2017, Version: 1.

Sensitive Determination of Microcystins from Environmental Waters Using On-Line SPE

JSB is an authorised partner of DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. i n s p i r a t i o n m e e t s i n n o v a t i o n!

Gagnez avec «David» Mighty MEPS contre les cartouches «Goliath» SPE

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

Sample Preparation Solid Phase Extraction Disks Cartridges. Horizon Technology, Inc. Salem, NH USA

HydroSpeed plate washer for 96- and 384-well formats

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

Pretreatments to LLE

AppNote 3/2009. Automation of Solid Phase Extraction Methods using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

Solvent Evaporation. Fast, Reliable and Affordable

API 2000 LC/MS/MS TurboIonSpray Ion Source Manual

HydroSpeed plate washer for 96- and 384-well formats

VACUSAFE. The aspiration system for safe disposal of liquids

FORENSICS GLASS BLOCK MANIFOLD INNOVATION THROUGH CHEMISTRY

On Line SPE LC/MS/MS Applications

Application Note. Authors. Abstract

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

Purge and Trap Troubleshooting Made Easy?

Standard Operating Procedure for Oil & Grease Method EPA1664A

RESOLUTION OIV-OENO MONOGRAPH ON TANNINS UPDATE OF THE METHOD FOR DETERMINATION OF POLYPHENOLS

New Designs and Formats in Solid-Phase Extraction Sample Preparation

Heto PowerDry LL1500 Freeze Dryer

160 EXTRACTION. Liquid/Liquid Extraction Apparatus. Continuous Liquid/Liquid Extraction with Built-in SLOW-DRY Concentrator

This document is a preview generated by EVS

CENTRIFAN PE. Evaporation the Easy, Environmental Way. Reliable Results for Small Samples. Small Volume Evaporator GREEN.

An Advanced Heat Exchanger for the Agilent 1290 Infinity Thermostatted Column Compartment

Q Trap LC/MS/MS TurboIonSpray Ion Source Manual. About This Manual... 1 Conventions Introduction... 3 Features... 4

Evaporation Biotage

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

Thermo Scientific KingFisher Pure RNA Plant Kit Revision 1.0

ACQUITY UPLC H-Class Sample Manager - Flow Through Needle Operator s Overview and Maintenance Information

Direct Injection and Online SPE LC/MS/MS for the Determination of Pharmaceuticals and Personal Care Products (PPCPs) in Water Samples

detectors UltiMate 3000 Variable Wavelength Detectors

Auto SPE-06Plus Solid Phase Extraction System. Reeko Instrument USA

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Customised HPLC Systems for Highest Performance

CentriVap. Centrifugal Vacuum Concentrators and Cold Traps

CryoFit. Handling of Flow Cell and Capillaries. User Guide. Version 002

Zoom Microplate Washer and Washer-Dispenser. Reliable Solutions for Your Daily Work

DETERMINATION OF PAH In Particulate Matter PM10 With SPE/EVAporation

Use of Automation to Achieve

HydroFlex FLEXIBLE AND RELIABLE MICROPLATE STRIP WASHING AND VACUUM FILTRATION IN A COMPACT, MODULAR PLATFORM. 21 CFR Part 11* 98/79/EC IVD-D*

SPE-DEX Automated Extraction System. Users Guide

Rain Forest Quick Guide

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

TYPES AND APPROPRIATE INJECTORS

The KingFisher Family

MultiPurpose Sampler MPS robotic series

Thermo Scientific KingFisher Viral NA Kit Instruction Manual Rev. 1.2

API LC/MS/MS TurboIonSpray Ion Source Manual Table of Contents

Description of a Standard 125 ml Separatory Funnel

CENTRIVAP CENTRIFUGAL CONCENTRATORS & COLD TRAPS

Development Centre for Evaporation and Thermal Separation Technologies

Chromatography. Research Supplies. 2014/2015 Catalog

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

RapidVap Dry Evaporation Systems

Agilent 1290 Infinity II Vialsampler Data Sheet

DYE QUALITY CONTROL REFERENCE MATERIAL KIT

Agilent 1290 Infinity II Online SPE Solution

Nexera-i Specifications Prominence-i Specifications

Transcription:

TN114 Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates New approaches to the quantitation of drugs and metabolites in biological fluids have increased the need for high throughput methodologies to avoid the traditional laboratory bottleneck of sample preparation. Solid phase extraction in a 96-well plate format such as ISOLUTE -96 Fixed Well Plates or ISOLUTE Array 96-well Plates is a solution to this problem. See Figure 1 for schematic of SPE 96-well plate. Figure 1. SPE using the 96-well Format Schematic of a 96-well SPE plate. Each cell represents a SPE column with reservoir, sorbent bed, and outlet. Chemistry Data Sheet The principles of SPE are the same, whether you are using standard format SPE columns, fixed well format ISOLUTE-96 plates, individual ISOLUTE Array columns/wells or complete (or partially complete) ISOLUTE Array plates. The main difference between SPE in columns (or individual wells) compared to plates is that it is not possible to individually control the flow of the various solvents through the cells of the plate. When using individual columns/wells, solvent flow through the column can be controlled using stopcocks. 96-well plates are processed on a vacuum manifold that applies vacuum to the whole plate, not the individual cells. The flow of solvents is therefore not controlled for each individual well, but over the whole plate. For this reason, certain physical handling parameters should be optimized to ensure trouble-free SPE in this format. Under optimized conditions, the variation in liquid flow across a 96-well SPE plate (either ISOLUTE-96 or ISOLUTE Array plates) has been found to be very similar to that found for the equivalent standard column format processed on a standard vacuum manifold. Typical RSDs are approximately 15% for all formats. As well as small changes to typical operating procedures during the SPE stages, care should also be taken during post SPE manipulations (e.g. sample evaporation/concentration, reconstitution, transfer to autosampler vials etc.) to minimize any potential problems in the plate format. It is useful to refer to individual wells by their row/column identifier (e.g. A3, H4).

Sample Processing/liquid Handling The speed of manually dispensing the conditioning solvent, equilibration solvent, sample, interference elution solvents and analyte elution solvent using the 96-well format can be greatly enhanced using a standard multi-port (8 or 12 position) dispenser. Solvent is dispensed simultaneously into every well of a column (i.e. A1 to H1) or row on the plate. There are also a number of automated liquid handling systems available which are suitable for SPE use. The Different 96-well SPE Plate Formats Available ISOLUTE-96 Fixed Well Plates ISOLUTE-96 fixed-well plates consist of 96 (8 x 12 matrix) fixed position wells packed with SPE sorbent the industry standard format. The nominal volume of each well is approximately 1.2 ml, and sorbent bed masses typically range from 25 100 mg per well (10 mg for resin based sorbents). ISOLUTE Array 96-well Plates ISOLUTE Array 96-well Plates and SPE columns have been designed for scientists who require a versatile SPE format that is compatible with both high and low sample throughput. The ISOLUTE Array system consists of individual SPE columns (1 or 2 ml volume, typically 10 100 mg sorbent bed mass) that can be processed using a traditional vacuum manifold (e.g. VacMaster TM -10 or -20 Sample Processing Manifolds) in exactly the same way as standard 1 ml ISOLUTE SPE Columns. Alternatively the individual ISOLUTE Array columns can be fitted into a 96 position (8 x 12) base plate for processing as a standard 96-well SPE plate using a plate format vacuum manifold (e.g. VacMaster-96 Sample Processing Manifold). The plate assembly can be complete (8 x 12 wells in place) or partially complete (any number of columns up to 96 in place). If using a partially complete ISOLUTE Array plate, the empty positions must be blocked off using base plate plugs. Populating the Array Base Plate Populate the ISOLUTE Array base plate with Array columns of the chosen configuration as follows: Place the base plate on the VacMaster-96 manifold lid. Fill positions A1 up to A12 as required, ensuring the columns are aligned correctly using the well alignment/removal tool, and press firmly into place. Fill positions B1 to H1 ensuring the columns are aligned correctly, and press firmly into place. Using the filled positions as a guide, place the remaining columns in position until the desired number of wells are filled. Using the leveling tool, press the columns firmly into place. Seal any remaining empty positions with strips of 8 base plate plugs. The ISOLUTE Array plate is now ready for use. Processing the 96-well SPE Plates The VacMaster-96 manifold is designed for processing both the ISOLUTE-96 and ISOLUTE Array plate formats. 2

Six-step SPE The most commonly used mode of solid phase extraction in bio-analytical applications is six-step SPE. It can produce extracts of biological fluids (plasma, serum, urine) having high purity, and concentrated analytes (drugs and/or metabolites). This mode involves 6 steps as follows: Sample pre-treatment Solvation (conditioning) Equilibration Sample loading Interference elution Analyte elution (A brief description of each of these steps is given below. Please request Chemistry Data Sheet TN110 for a full description of each of these steps, and other modes of operation of SPE). Chemistry Data Sheets describing the use of specific ISOLUTE sorbents are also available. Sample Pre-treatment See relevant Chemistry Data Sheets for specific sorbents. As stated previously the chemistry of SPE remains the same for 96- well format. Dilution Factors As biological fluids (particularly plasma or serum samples) can vary significantly in their viscosity from sample to sample, it is important to use dilution to lower and standardize the viscosity of the samples, to ensure even, reproducible flow from well to well, and minimize well blockage. In general, the greater the dilution factor, the more even the results. In order to maintain the control of both chemical and physical parameters, dilution with a suitable BUFFER is recommended. See Figure 2 for the effect of dilution on flow rate. As plasma varies in viscosity, this is a guideline to dilution only. Buffer 1:9 1:5 1:2 1:1 Undiluted Plasma NO FLOW 0 10 20 30 40 50 Relative flow rates (µl/min) Figure 2. Flow rates of 250 µl of undiluted plasma, and plasma diluted with buffer, using 25 mg ISOLUTE Array plate 3

Solvation Solvation is usually necessary to prepare the sorbent for the extraction process. For certain sorbents the sorbent bed should not be allowed to dry out after solvation. It is recommended that wells are initially conditioned with an excess of methanol (or other suitable solvent) loaded under gravity or low vacuum (-2 "Hg). This has the effect of making the flow of subsequent solvent/sample loading steps more even across the plate. Typical Volumes Bed Mass Solvation Volume 10 mg 220 µl 25 mg 500 µl 100 mg 2 ml It has been noted that if the top frit is allowed to become dry (i.e. the level of solvation solvent drops below the surface of the frit material), it can be difficult to induce the flow of the next aqueous step using a low vacuum. This is due to the hydrophobic nature of the frit material, and is not related to the sorbent type (applies equally to silica based and resin based sorbents). The following procedures apply to each subsequent aqueous step of the method. There are various procedures that can help minimize this. Processing regimes differ slightly between low bed mass (10 and 25 mg) and higher bed mass (50 and 100 mg) plates. Processing Procedures 10 mg In general, all steps can be loaded under gravity. Under these conditions, frits are unlikely to dry out, and flows of subsequent steps will be unaffected. 25 mg In general, all steps can be loaded under gravity, although some variation in flow may occur under these conditions. If necessary, a low vacuum ( 2 "Hg) is ample to give a good flow rate and is not high enough to dry the frits. 50 and 100 mg For best results, approximately 5% methanol should be added to all subsequent aqueous steps (provided this does not affect analyte recovery). All wells should be loaded with no vacuum, and a pulse of high vacuum ( 10 "Hg, 2 seconds) applied to initiate flow. The vacuum should then be reduced to 2 "Hg. In general we recommend that as long as sufficient capacity is obtained from a 10 or 25 mg bed mass, that this configuration be the bed mass of choice for 96-well plate based SPE methods. If the subsequent step has a high % organic component, the hydrophobicity of the frit will be overcome by the solvent, and flow should occur without problems. For ISOLUTE Array plates, it is possible to optimize vacuum levels on individual wells on a standard vacuum manifold (eg VacMaster-10 or -20 manifold), and transfer directly to the plate for increased throughput. 4

Equilibration To maximize retention of the analyte by the sorbent, the column is treated with a solvent that is as matrix-like as possible. A typical volume of equilibration solvent is 0.2 1 ml/50 mg of sorbent. Sample Loading Load the diluted sample as follows:- 10 mg Load under gravity 25 mg Load under gravity, OR apply a low vacuum of 2" Hg, either during or after sample application 50 and 100 mg plate Apply a low vacuum of 2" Hg, either during or after sample application, OR load sample into all wells with no vacuum, followed by a pulse of 5 to 10 "Hg, reduced to 2" Hg after 2 seconds Interference Elution The purpose of interference elution is to selectively remove undesired compounds from the sorbent without eluting the analytes. A typical volume of interference elution solvent is 0.2 1 ml /50 mg of sorbent. Interference elution should be carried out under minimum vacuum. Sorbent drying may be necessary to remove excess solvent prior to elution. In the plate format, it is not easy to visually judge whether an individual well is dry. Any drying regime therefore should be clearly specified in terms of drying time and vacuum required. A typical drying time for subsequent elution with water miscible solvents is about 30 seconds per 10 mg sorbent at -10 "Hg. If a water immiscible solvent is used for elution, drying times would be significantly longer. We recommend that the optimum conditions be determined experimentally for individual applications. Elution Prior to elution, ensure that the collection plate has been inserted into the VacMaster-96 manifold, in the correct alignment (i.e. position A1 on the extraction plate is aligned directly above position A1 on collection plate). This will ensure that individual samples are not confused. Replace the polypropylene lid of the VacMaster-96 manifold and ISOLUTE-96 or ISOLUTE Array plates. Ensure that the extraction plate outlets are correctly positioned, and inserted into the collection plate wells. Spacers are available to raise collection plates, and ensure penetration. This is important to prevent cross contamination between wells. Apply the elution solvent and allow to flow under suitable vacuum conditions as appropriate to bed mass. For all bed masses, a pulse of vacuum at the end of elution will ensure that all elution solvent is collected. Minimum elution volumes as low as 100 µl for 25 mg sorbent mass may be achieved with robust/optimized SPE methods. Flow control is important to ensure reproducibility. 5

Post SPE Sample Manipulation When using either ISOLUTE-96 or ISOLUTE Array plates, the analytes are eluted into a collection plate (consisting of an 8 x 12 matrix of collection wells). These plates are available in 1 and 2 ml volumes as standard. The collection plate can be sealed for storage purposes if analysis is not to be performed immediately. Direct Injection To minimize sample manipulation following SPE, analytes should be eluted using a solvent system that is directly compatible with the analytical technique. If the elution solvent is too strong for compatibility with the analytical technique, and further concentration is not required, the eluent should be diluted with mobile phase buffer. The collection plate can then be placed directly onto a 96-position autosampler. Eluent Evaporation/Concentration Depending on the analytical technique/methodology to be used to analyze the extracted samples, it may be necessary to further concentrate, or evaporate and reconstitute the eluent, prior to the analytical stage. Using a 96-well sample concentrator (e.g. SPE Dry TM 96), this step can be performed in the collection plate. In the plate format, it is not easy to visually judge whether an individual well is dry, or what volume of solvent remains. Any drying regime therefore should be clearly specified in terms of instrument, temperature, drying time and gas type and flow rate. See page 7 for solvent evaporation times using the SPE Dry 96 system. 6

SPE Dry 96 solvent evaporation times Solvent * 500 µl/40 C ** 1 ml/40 C 500 µl/60 C ** 1 ml/40 C Water 90 165 46 86 Methanol 14 28 11 20 Methanol/Water 50/50 (v/v) 46 95 28 56 Propan-2-ol 16.5 26 11.5 16.5 Acetonitrile/Water 50/50 (v/v) 51 60 31 36 Methanol/Acetonitrile 50/50 (v/v) 19 24 12 15 Acetonitrile 17 20 12 15.5 Methanol/1% (v/v) NH 4 OH 18 28 13.5 16 DMF 73 105 33 41 Methanol/Methylene Chloride 50/50 (v/v) 12 15.5 7.5 9.5 Methylene Chloride/1% (v/v) NH 4 OH 8.5 11.5 6 8 * 500 µl volumes were in a 1 ml collection plate ** 1 ml volumes were in a 2 ml collection plate 1. Experiments were conducted with flow rate at 50 L/min at the upper manifold and 30 L/min at the lower manifold. 2. Drying gas used was compressed air. Only standard moisture trap was used within the system. Moisture content of ambient air will affect results. 3. All temperatures listed in above table refer to the top head. Bottom unit was 20 C higher. Typical evaporation times (minutes) for commonly used solvents. Forced gas convection heating from above and below each microplate well evaporates solvents up to five times more rapidly than other microplate sample evaporation systems. www.biotage.com UNITED STATES AND CANADA Main Office: +1 434 979 2319 Toll Free: +1 800 446 4752 Fax: +1 434 979 4743 Order Tel: +1 434 220 2687 Order Fax: +1 434 296 8217 ordermailbox@biotage.com UNITED KINGDOM Main Office: +44 1443 811811 Fax: +44 1443 816552 Order Tel: +44 1443 811822 Order Fax: +44 1443 816816 eurosales@eu.biotage.com SWEDEN Main Office: +46 18 56 5900 Fax: +46 18 59 1922 Order Tel: +46 18 56 57 10 Order Fax: +46 18 56 57 05 order@eu.biotage.com GERMANY Tel: +49 7624 90 80 0 Fax: +49 7624 90 80 10 separtis@eu.biotage.com SWITZERLAND Tel: +41 61 743 90 15 Fax: +41 61 743 90 18 separtis@eu.biotage.com AUSTRIA Tel: +43 2231 63167 Fax: +43 2231 63520 separtis@eu.biotage.com JAPAN Tel: +81 422 28 1233 Fax: +81 422 28 1236 order@biotage.co.jp Copyright 2006. All rights reserved. All brand and product names are trademarks or registered trademarks of their respective companies. The information contained in this document is subject to change without notice. TN-114.06