Additional deviations may possibly be found if a complete type test is carried out on the product.

Similar documents
LOW VOLTAGE DIRECTIVE 2006/95/EC

LOW VOLTAGE DIRECTIVE 2006/95/EC

INTERNATIONAL STANDARD

CE marking & your legal obligations

CE Marking and Technical Standardisation

ENGLISH USER S MANUAL PRE SOAKER 3600

AS/NZS IEC :2013

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

4) Intrinsic Safety Certification

Installer: (Name, address, telephone)

Installer: (Name, address, telephone)

Datasheet - MZM 100 ST2-1P2PWREM-A

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Datasheet - MZM 100 ST-SD2PREM-A

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

Datasheet - MZM 100 B ST2-SD2PREM-A

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Installer: (Name, address, telephone number)

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

Living with the Construction Products Directive - The Role of the Notified Bodies

CE marking & your legal obligations

Installer: (Name, address, telephone number)

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

INSTRUCTION MANUAL (ATEX)

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

INTERNATIONAL STANDARD

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

Kitchen Appliance Lift INSTRUCTION MANUAL

Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR)

The New EMC Directive 2004/108/EC

Alarm Switchgear AS1-M

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

Chain saws (electric mains powered and battery powered)

INSTRUCTION MANUAL (ATEX / IECEx)

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

Edition 6, From serial no Publ. no Orwak 5030-CE. Operating manual

INTERNATIONAL STANDARD

TECHNICAL NOTICE GH/GHO/GAE V

INSTRUCTION MANUAL (ATEX / IECEx)

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

Statistics on RAPEX notifications (November 2017)

INTERNATIONAL STANDARD

Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

Installer: (Name, address, telephone)

Declaration of Conformity Declaration of Performance Notes

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

PQS Independent type-testing protocol

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTERNATIONAL STANDARD

Stationary and Portable Spas Important Safety Information

EU-TYPE EXAMINATION CERTIFICATE

INSTRUCTION MANUAL (ATEX / IECEx)

Council Directive 93/68/EEC of 22 July 1993 amending Directives

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

Installation / Monitoring Technique

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

Consumer Products Services Germany GmbH Türkheim Germany

Audible warning devices for external alarm

Motorised swing doors User manual (translation of the original instructions) IP2225EN

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

The New EMC Directive 2004/108/EC

ERTIFICATE. No. P This Nemko Certificate replaces the Certificate issued 27 March 2003 due to an error in the Factory listing.

Latch key safety limit switches Technical data

New Legal Framework Carlo Casati

Test report. ifesesws^ Date: Number: T /17 Project file: C Pages: Product: Fixed general purpose LED luminaire

INTERNATIONAL STANDARD

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

DECLARATION OF PERFORMANCE

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY

INTERNATIONAL STANDARD NORME INTERNATIONALE

Declaration of Performance

CE marking of fire-resistant doors the right way!

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L

a guide to the interpretation of

COMMISSION DELEGATED REGULATION (EU)

LOVAG TEST INSTRUCTION IEC/EN

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

DIRECTIVES. DIRECTIVE 2009/142/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 relating to appliances burning gaseous fuels

INTERNATIONAL STANDARD

Electromagnetic Locking Devices Performance Requirements

Electrical Equipment (implementing the Low Voltage Directive)

INTERNATIONAL STANDARD

Gas Appliances Directive - Advisory Committee. Comité Consultatif de la Directive Appareils a Gaz

DECLARATION OF PERFORMANCE

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

INTERNATIONAL STANDARD

Operating instructions

DECLARATION OF PERFORMANCE

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Transcription:

Diary No. 13EV4171 Reference No 1315333 MARKET SURVEILLANCE TEST REPORT - LVD The tests cover parts of the requirements for AC adapter stated in the standard SS-EN 60950: 2006 + A11 + A1 + A12 and EN 50075. References to clauses are given to SS- EN 60950: 2006 + A11 + A1 + A12, unless stated otherwise. Additional deviations may possibly be found if a complete type test is carried out on the product. Deviations are graded according to three levels with corresponding codes. The first level, serious criticism, corresponds to code 3, criticism to code 2 and remark, to code 1. DESCRIPTION OF TEST SAMPLE Type of product: Replacemant AC Adapter Manufacturer: - Retailer: - Type designation: A1184 Rating: AC INPUT: 100-240V, 1.5A, 50/60Hz DC OUTPUT: 16.5V, 3.65A Serial number: - EAN-code: - Certification marks: - CE marked: Yes Others: - RESULT The table below shows the number of criticisms according to the various codes. Code: Number: Serious criticism (3): - Criticism (2): 2 Remark (1): 1 TEST AND INSPECTIONS PERFORMED Clause 1.7.1 Power rating Clause 2.10 Clearances, creepage distances and distances through insulation (excluding internal distances in components) Clause 4.2 Mechanical strength Clause 4.6 Openings in enclosure Clause 5.1 Touch current Clause 5.2 Electric strength test 1(2)

Diary No. 13EV4171 Reference No. 1315333 LIST OF DEVIATIONS 1. Manufacturer s name or trad-mark is missing (Cl. 1.7 acc. to standard EN 60950: 2006 + A11 + A1 + A12) Code: (2) 2. Electric strength test between primary and secondary output, required 3000V, break down at 2500V. Electric strength test on transformer between primary and secondary, required 3000V, break down at 2600V. (Cl. 5.2 acc. to standard EN 60950: 2006 + A11 + A1 + A12) Code: (1) 3. Clearances and creepage distances in transformer, required clearance 4.0mm and creepage 4.8mm. Actual measured distance 2.5mm. (Cl. 2.10.3 and 4 acc. to standard EN 60950: 2006 + A11 + A1 + A12) Code: (2) 2(2)

NOTIFICATION UNDER ARTICLE 9 OF THE LOW VOLTAGE DIRECTIVE Notification no. SE-14-02 1. Name of the notifying authority a) Member State: Sweden b) Full name and address, telephone and fax numbers, e-mail of the department and of the competent official supplying the information: Swedish National Electrical Safety Board P.O. Box 4 S-681 21 Kristinehamn; Sweden Tel: + 46 550 851 00 Fax: + 46 550 851 01 E-mail: info@elsakerhetsverket.se 2. Identification of the equipment a) Name and description: Replacemant AC Adapter b) Brand and type: Unknown brand, typedesignation is A1184 c) Name and address of the owner of the brand: Unknown d) Name and address of the manufacturer or importer: Man: Imp: Riset Adapterexperten AB Vasängsvägen 126 302 58 Halmstad, Sweden e) Other countries in which the equipment is placed on the market: Unknown f) Electrical specifications (voltage, wattage, class of protection against electric shock, IP classification): AC INPUT: 100-240V, 1.5A, 50/60Hz DC OUTPUT: 16.5V, 3.65A

3. Proof of conformity a) CE marking: yes no b) Other directive(s) covered by CE marking: yes which one(s)? EMC no c) Other markings: d) Written declaration of conformity: available requested not requested acceptable not acceptable not available g) Technical documentation: available requested not requested acceptable not acceptable not available h) Report drawn up by a notified body: available requested not requested Name of the notified body: Reference number of the report: not available

4. Details of the measures taken a) manufacturer importer into the EEA Type of measure: importer to Sweden removal from circulation prohibition of the placing of the equipment on the market general measures making the placing of the equipment on the market subject to specific conditions other b) manufacturer Importer into the EEA Importer to Sweden Date: 2014-01-29 Reference: Method of notification: 13EV4171 By letter 5. Reasons for the measures taken Non-conformity with Article 2 of the Low Voltage Directive resulting from a shortcoming in the applicable standard(s) Standard(s) reference: Non-conformity with Article 2 of the Low Voltage Directive resulting from a faulty application of the applicable standard(s) Standard(s) reference: EN 60950 Where no standard applied, non compliance with the rules of good engineering practice as referred to in Article 2 of the Low Voltage Directive

6. Brief description of faults, nature of hazards and/or shortcomings in standards observed Manufacturer s name or trad-mark is missing. Electric strength test between primary and secondary output, required 3000V, break down at 2500V. Electric strength test on transformer between primary and secondary, required 3000V, break down at 2600V. Clearances and creepage distances in transformer, required clearance 4.0mm and creepage 4.8mm. Actual measured distance 2.5mm. 7. Additional information annexed copy of test reports 2 (pages) photographs 1 (pages) copy of declaration of conformity distribution chain others Date: 2014-01-29 Karl-Hugo Hult Head of Department Martin Gustafsson