Diary No. 13EV4171 Reference No 1315333 MARKET SURVEILLANCE TEST REPORT - LVD The tests cover parts of the requirements for AC adapter stated in the standard SS-EN 60950: 2006 + A11 + A1 + A12 and EN 50075. References to clauses are given to SS- EN 60950: 2006 + A11 + A1 + A12, unless stated otherwise. Additional deviations may possibly be found if a complete type test is carried out on the product. Deviations are graded according to three levels with corresponding codes. The first level, serious criticism, corresponds to code 3, criticism to code 2 and remark, to code 1. DESCRIPTION OF TEST SAMPLE Type of product: Replacemant AC Adapter Manufacturer: - Retailer: - Type designation: A1184 Rating: AC INPUT: 100-240V, 1.5A, 50/60Hz DC OUTPUT: 16.5V, 3.65A Serial number: - EAN-code: - Certification marks: - CE marked: Yes Others: - RESULT The table below shows the number of criticisms according to the various codes. Code: Number: Serious criticism (3): - Criticism (2): 2 Remark (1): 1 TEST AND INSPECTIONS PERFORMED Clause 1.7.1 Power rating Clause 2.10 Clearances, creepage distances and distances through insulation (excluding internal distances in components) Clause 4.2 Mechanical strength Clause 4.6 Openings in enclosure Clause 5.1 Touch current Clause 5.2 Electric strength test 1(2)
Diary No. 13EV4171 Reference No. 1315333 LIST OF DEVIATIONS 1. Manufacturer s name or trad-mark is missing (Cl. 1.7 acc. to standard EN 60950: 2006 + A11 + A1 + A12) Code: (2) 2. Electric strength test between primary and secondary output, required 3000V, break down at 2500V. Electric strength test on transformer between primary and secondary, required 3000V, break down at 2600V. (Cl. 5.2 acc. to standard EN 60950: 2006 + A11 + A1 + A12) Code: (1) 3. Clearances and creepage distances in transformer, required clearance 4.0mm and creepage 4.8mm. Actual measured distance 2.5mm. (Cl. 2.10.3 and 4 acc. to standard EN 60950: 2006 + A11 + A1 + A12) Code: (2) 2(2)
NOTIFICATION UNDER ARTICLE 9 OF THE LOW VOLTAGE DIRECTIVE Notification no. SE-14-02 1. Name of the notifying authority a) Member State: Sweden b) Full name and address, telephone and fax numbers, e-mail of the department and of the competent official supplying the information: Swedish National Electrical Safety Board P.O. Box 4 S-681 21 Kristinehamn; Sweden Tel: + 46 550 851 00 Fax: + 46 550 851 01 E-mail: info@elsakerhetsverket.se 2. Identification of the equipment a) Name and description: Replacemant AC Adapter b) Brand and type: Unknown brand, typedesignation is A1184 c) Name and address of the owner of the brand: Unknown d) Name and address of the manufacturer or importer: Man: Imp: Riset Adapterexperten AB Vasängsvägen 126 302 58 Halmstad, Sweden e) Other countries in which the equipment is placed on the market: Unknown f) Electrical specifications (voltage, wattage, class of protection against electric shock, IP classification): AC INPUT: 100-240V, 1.5A, 50/60Hz DC OUTPUT: 16.5V, 3.65A
3. Proof of conformity a) CE marking: yes no b) Other directive(s) covered by CE marking: yes which one(s)? EMC no c) Other markings: d) Written declaration of conformity: available requested not requested acceptable not acceptable not available g) Technical documentation: available requested not requested acceptable not acceptable not available h) Report drawn up by a notified body: available requested not requested Name of the notified body: Reference number of the report: not available
4. Details of the measures taken a) manufacturer importer into the EEA Type of measure: importer to Sweden removal from circulation prohibition of the placing of the equipment on the market general measures making the placing of the equipment on the market subject to specific conditions other b) manufacturer Importer into the EEA Importer to Sweden Date: 2014-01-29 Reference: Method of notification: 13EV4171 By letter 5. Reasons for the measures taken Non-conformity with Article 2 of the Low Voltage Directive resulting from a shortcoming in the applicable standard(s) Standard(s) reference: Non-conformity with Article 2 of the Low Voltage Directive resulting from a faulty application of the applicable standard(s) Standard(s) reference: EN 60950 Where no standard applied, non compliance with the rules of good engineering practice as referred to in Article 2 of the Low Voltage Directive
6. Brief description of faults, nature of hazards and/or shortcomings in standards observed Manufacturer s name or trad-mark is missing. Electric strength test between primary and secondary output, required 3000V, break down at 2500V. Electric strength test on transformer between primary and secondary, required 3000V, break down at 2600V. Clearances and creepage distances in transformer, required clearance 4.0mm and creepage 4.8mm. Actual measured distance 2.5mm. 7. Additional information annexed copy of test reports 2 (pages) photographs 1 (pages) copy of declaration of conformity distribution chain others Date: 2014-01-29 Karl-Hugo Hult Head of Department Martin Gustafsson