FAN COIL UNITS. The optimal solution for limited space

Similar documents
T1/B1 OPTIONAL ASEPSIS HYGIENIC AIR HANDLING UNITS. Fully washable & free cold bridge design for food and low temperature applications

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

AIR HANDLING UNITS. Product Profile

ZHK 2000 CUSTOMISED AIR HANDLING UNITS. Environmentally friendly and clean concept solutions for comfort, hospital and industrial applications.

ZHK FI HYGIENIC AIR HANDLING UNIT. Fully washable units for the food and beverage industry

Blower-YEFB-020-3R-1maxVel

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

AIR HANDLING UNITS ZHK 2000

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

EHH SERIES DRAW THROUGH FAN COILS CFM

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

EC Motor Fan Coil Units. IMD-Y Series l/s

LOW STATIC HYDRONIC DUCTED UNIT

DECORATIVE UNITS. Technical IOM manual for under ceiling and floor mount units

Efficient Cooling and Heating. Flexibility Is The Key

YAH SERIES FAN COIL UNITS

OPERATION AND MAINTENANCE MANUAL

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

CASSETTE UNIT. Comfort Circle

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Caice Attenuator Selector - Specifier Edition

Halton Rex 600 Basic R6B - Active chilled beam

PRODUCT GUIDE

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

NEXT DL NEXT DL. rcgroupairconditioning

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

VERTICAL FAN COIL UNITS

CHILLED WATER CASSETTES

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

next DX.U.S* 052.Z2.H6.DC

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Energy. The Energy ducted units have been designed. Heat Recovery Unit

Caice Attenuator Selector - Specifier Edition

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Centeral Station Air Handling Unit

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

Double Skin Air Handling Units

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

LZT High efficiency air to water heat pumps with E.V.I. compressors

next p dw next p dw rcgroupairconditioning

Double Skin Casing Air Handling Units

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Panther Fan Coil Unit

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

QTS SELECTION TECHNICAL BOOKLET

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

AQX Air handling units. Air flow 1, ,000 m 3 /h (350-44,400 l/s)

AIR HANDLER SPECIFICATION

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Air Handling Units. Real HVACR people who understand your needs.

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Indoor Air Quality. For assured. Double Skin Air Handling Units

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Direct Fired Heater Model AD Specification

SECTION AIR COILS

LZA High efficiency air to water heat pumps with HP compressor

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

UniTrane Ductable Units D-line and B-Line

SECTION WATER-SOURCE UNITARY HEAT PUMPS

General Catalogue. FORM SSI - G.C (94)

The technical and dimensional data reported in this manual may be modified in view of any product improvement.

Product Specifications. Vertical Floor Consoles By First Co.

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

KELVIN Clim F497. Kelvin air conditioning

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

NEW GREEN TECHNOLOGY

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

Balancing & Control. Frese OPTIMIZER 6-way. Pressure Independent Control Group

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Halton CHB Active chilled beam with boost function for bulkhead installation

Transcription:

FAN COIL UNITS The optimal solution for limited space

CLEAN AIR SINCE 1963 Euroclima is a company with extensive international operations with four manufacturing facilities in Italy, Austria and India and more than 34.000 m² of production and offices. We specialise in the manufacturing and worldwide distribution of air handling units and fan coil units. Euroclima has a well distributed network of sales and service across Europe, Asia, Middle East and Northern Africa. Our partners in various countries assume a surface covering responsibility for marketing, local servicing and optimal assistance. HOSPITAL AIR TREATMENT SUCCESS STORY Since 1963, Euroclima is a world leading manufacturer in customised air conditioning and ventilation systems. We design, develop, manufacture and commercialise high quality air handling products for all applications, from basic comfort to health care and industrial processes. Euroclima is a company with extensive, high quality European operation and manufacturing facilities located in Italy and Austria. Euroclima is well represented all over the world to provide optimum support, assistance and service to our customers. For the last 50 years, Euroclima shipped more than 100M units all over the world from 100 to 5000 l/s. Pacific HVAC Engineering are our chosen partners for Euroclima. With successful completion of hundreds of projects across a range of industries including; defence, office buildings, universities and shopping centres. There are approximately 5,000 units in operation throughout Australia, New Zealand and Fiji. The success of Euroclima comes from the way we manage projects, understand our clients requirements and customise the FCU for the specific project or application. We offer: Professional and engaging employees, to better serve customers Strong relationships with partners, customers and suppliers Experience and expertise to find innovative solutions Reliable and high quality products 2 COIL UNITS

DESCRIPTION Euroclima double skin self-supporting units are the optimal solution for limited space, mainly used for installation in a false ceiling. Thanks to the double skin construction (23mm sound absorbing rock wool insulation with 20kg/m³), the unit can handle high static pressure drops with excellent acoustic performance. The wide range of heating and cooling capacities, efficient control of room conditions, and the independent user control offered by single room units are major advantages. With unique characteristics and benefits, our units are in a leading position in the market for environmental control. Special features include low noise, cleanliness of filtered air and fresh air makeup either directly from outside or by a central air conditioning system. These benefits provide a guarantee of quality and product rationality in design, efficiency and use. Our units offer a quick installation time and a long operational life due to the utilisation of solid metallic components. KEY FEATURES Low profile design Polyester coated external double skin case EC and AC fan motor options available EC with 0-10V control AC units are complete with 3 speed motors (High/Medium/Low) Chilled water cooling coils available with 4, 5 or 6 rows and 2.1 & 2.5 fins per mm Hot water heating coils available with 1 or 2 rows and 2.1 & 2.5 fins per mm Combined maximum of 6 cooling and 2 heating rows available per unit CONSTRUCTION DS Series: Double skin self-supporting panel 25 mm thick, outer skin 0,8 mm RAL 9010 polyester coating (min 20 μm thickness). Inner skin 0,6 mm galvanized sheet steel. Insulating material rock wool, non-combustible, fire class A1, 20 kg/m³, Rw 31 db(a). Construction made of galvanized frame and galvanized cover sheets with RAL 9010. Optional RAL colour available. Full insulation cover can be applied on request. Inclined drain pans made of galvanized sheet steel additional insulated with 5 mm closed cells self-adhesive polythene fireproof insulation (Class 1 European standard). Optional stainless steel or epoxy powder coating drain pans available. MOTORS Electronic motor (EC) Single phase brushless DC motors in accordance with European Standard ErP2015 n. 327/2011. V230/1Ph/50Hz power supply, working temperature -20 / + 55 C, IP20 or IP40 protection, thermal protection as standard. AC On/off motor Standard motors are suitable for a V230/1Ph/50Hz power supply, with permanently coupled capacitor. Motors provided with selflubricating bearings and cast aluminium enclosure rated to IP22 or IP52, class B with thermal protection. 7 speeds are available, 3 are factory wired to a fan speed switch. For TO series only 3 speeds available. 64 62 72 72 71 60 61 59 59 P% Qv COIL UNITS 3

4 COIL UNITS

SUGGESTED SPECIFICATION FACTORY ACCESSORIES The fan coil units shall be of the EUROCLIMA TH-DS series as distributed by Pacific HVAC Engineering and be of the model and dimensional data as shown in the technical schedule/drawings. Units shall be manufactured from double skin construction with SS304 drain pans. Insulation material shall be rock wool, non-combustible, fire class A1. Cooling, heating capacities and external static pressures shall be as shown on the schedule. Fans shall be forward curved centrifugal type driven by either brushless DC motors or AC motors with 3 speeds as specified in the schedules. TECHNICAL SPECIFICATION COILS Tubes are manufactured from 9,5 mm (3/8 ) OD copper and are staggered for better heat transfer. High efficiency louvered aluminium fins bonded to the tubes. Coil headers made of brass, copper or steel with female connections. Execution suitable for 2-pipe installation or 4-pipe installation. Manual drain and air vent, automatic air vents optional available. Standard connection sides is left, optional right is available. Maximal working pressure 24 bar, maximal water flow temperature 120 C. DRAIN TRAYS Galvanized sheet steel with an epoxy paint finish in both sides. On horizontal units the drain tray is fully insulated with 5mm closed cell politeness foam, which has a class 1 European std fire resistance. On vertical units, insulation only covers all the areas where condensate collects in the tray, which is inclined. Full insulation cover and increased thickness can be applied on request. Alternative insulation types and stainless steel drain trays are also possible. AIR FILTERS WALL THERMOSTATS A variety of thermostats are available, for installation on walls or direct to the units for BMS control and wired to the fan motor in the factory. AIR FILTERS These kits are available with 2 or 3-way valves, for 2 or 4-pipe installation. They can be supplied loose or factory fitted. ELECTRICAL HEATERS Stainless steel AISI 304 with alu-zinc fins, double safety thermostat with manual and automatic over temperature, power contactor, possible to have air flow switch included. Technical and constructional characteristics according to European safety regulations and Australian Standards. Several heating elements can be connected parallel to increase the heating capacity. PLENUMS Supply monoblock plenum with round spigot connections (max. DN 250 mm), return plenum is to be mounted separately. It can be internally insulated with closed cells self-adhesive polyethylene, fireproof insulation (class 1 European standard). TYPICAL APPLICATIONS Commercial and industrial application including Hospitals, Office Building, Shopping Centres and Universities. FACTORY WARRANTY Warranty is a standard 12 months from practical completion. The synthetic media is cleanable and enclosed in a galvanized frame with wire mesh support. Efficiency class is G3 washable filters to F7 48mm Panel Filters with aluminum mesh. COIL UNITS 5

MORE FROM EUROCLIMA T1/B1 OPTIONAL FAN COIL UNITS The optimal solution for limited space ASEPSIS HYGIENIC AIR HANDLING UNITS Fully washable & free cold bridge design for food and low temperature applications CLEANLINE MEDICAL AIR HANDLING UNIT Compact & hygienic solutions for operating theaters integrated controls and dx cooling system 90% EFFICIENCY ETA ACCU HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System ZHK FI HYGIENIC AIR HANDLING UNIT Fully Washable units for food and beverage industry. Stainless steel; fully welded and rounded corners. ZHK 2000 CUSTOMISED AIR HANDLING UNITS Environmentally friendly and clean concept solutions for comfort, hospital and industrial applications. Possible Technical Modifications are possible. PACIFIC HVAC ENGINEERING Pacific HVAC Engineering Queensland Pacific HVAC Engineering Melbourne 1/197 Murarrie Road Murarrie, Queensland 4172, Australia 2/63 Wells Road Chelsea Heights, Victoria 3196, Australia Email: Phone: info@pacifichvac.com tba Email: info@pacifichvac.com Phone : 1300 733 833 +61(3) 9773 3200