SPRAYING MANUAL. Adhesives That Outperform

Similar documents
Roofing Adhesive SARNACOL 2172 Spray

OUR REEFER REPAIR ADHESIVE RANGE. Adhesives That Outperform

SLS Etch Primer. 300g aerosol, 250ml tin, 500ml tin, 1L tin, 4L tin

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range

Application Instructions

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range

ROOFING TECHNICAL BULLETIN #07-12

Cameo White January (first two digits indicate the month of expiration, 01 12)

Aqueous Thermostatic Surface Mounted Bar Shower Valve With Fast Fit Connections

INSTRUCTION MANUAL W-400

Installation & Operation Instructions Nr _EN_Manual

Models: GW/R-T GW/R-2-T GW/R-3-T

ExoAir Fluids & TREMproof 260 Spraying Guide

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

Vacuum Bonding of Safety and Architectural Glass Laminates

The FTA-02 Fiber Arranger

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

ExoAir Fluids & TREMproof 260 Spraying Guide

Underfloor Heating Installation Guide

Wagner Product Training

Dehydrator. This construction will dehydrate fruits and vegetables, helping preserve them and concentrating their flavour.

Pot Belly Black. Overview. Suitable Surfaces

Page 1 of 18. Part# /5/2013

ST-1 Surface Treatment

INSTALLATION INSTRUCTIONS FOR. ProTek RIGID VINYL WALLCOVERING

ad notam MOUNTING SYSTEM FOR RECESSED IN-WALL APPLICATION

Traditional Rigid Riser With Eight Inch Rose

Instructions for Coating Fimbel Garage Door Panels

R7520SS COLORS/FINISHES. Stainless Steel 16 9/16" 7 15/16"

CORNICE FOR INDIRECT LIGHTING

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

ENRGY CURB APPLICATION GUIDE FOR TPO ROOFING SYSTEMS

NOVITHERM TM Heat Reflectors Installation Guide

Installation Manual EF5000 NZ

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

ASSEMBLY INSTRUCTIONS HOODED GAS GRILL Model: UC-SBP

Induction K heater

In-Wall Slide-out OEM INSTALLATION MANUAL. In-Wall Slide-out OEM Installation Manual

The upright hot water pressure washer for professionals.

Model HD 3000 Part No High Pressure Washer Operator Manual

Installation Instructions. Earth Shower Tray 226CAW 1214RN. Earth 226CAW.indd 1 07/08/ :44

PATIO HEATER OPERATING & MAINTENANCE INSTRUCTIONS MODEL No. PHT3. Stainless

Installation Manual PS-225 & PS-275

INSTALLATION INSTRUCTIONS

TH01 Molding, Bodyside

Optimum. Installation Instructions. A Shower Tray 1. Flange Plate. Screws. Bottle Trap. Extendable Flexi Waste Pipe. Drill Bit.

SC300 BEFORE USE PLEASE READ THE MANUAL AND SAFETY INSTRUCTIONS.

PS-2/ES Automated pack & tag machine with IndES fastening system

Assembly instructions

PORTABLE SMART WASHER

Beautifully Traditional

Chiltern Model Steam Engines

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

INSTALLATION MANUAL REFRIGERATION IK008 INTEGRATION KIT WTB4600, KTM4602, WTB5400, KTM5402, WBE4500, KBM4502, WBE5300, KBM5302, WFB4204, WRB5004

Dovre 250 Cast Iron Gas Stove

Built-in Gas Hob CZ55554 CZ55571

GETZ MANUFACTURING PART NO.: MODEL: SV1 100 PR VACUFILL SYSTEM (Revised 6/7/05)

THE INSTRUCTIONS IN THIS MANUAL APPLY TO KENT GAS FIRES. CONTENTS:-

GETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14)

ELECTRIC ASH CAN Model: CVACASH500 Part No:

3M Aerosols. Electrical Products Division. 3 Innovation

Beautifully Traditional

Storage stable liquid urea-formaldehyde adhesive for the furniture and wood industry

P.O.D. Pressure On Demand

SIMPLY UNCOMPLICATED TANNING SYSTEMS Training Manual

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

U.1347LS. Perrin & Rowe Kitchen Filtered Hot Water Dispensers 2 3/8" 5 1/2" 10" 6 1/2" 3 7/8" Ø1 7/8" 1 3/4" MAX Ø1 1/4" HOLE

OPERATING MANUAL AUTOMATIC SPRAY GUN CLEANERS UG7500 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

600mm Electric Cooktop with Solid Elements

NORDYNE has received reports of malfunctioning TXV valves in ton split systems and package units.

L eather Care & Cleaning

BQ-260/260L. Important Information BOOK BINDER

R7521SS COLORS/FINISHES. Stainless Steel 21 15/16" 1 3/16" 8 5/64" 1 25/32" 2 1/8" 23 5/8" Max. 1 3/8" G1/2" Female

3 Water Based Foam Adhesive

READ CAREFULLY AND KEEP FOR FUTURE REFERENCE

How to Build A State-of-the-Art, High Yielding Aeroponic Growing System

OPERATING INSTRUCTIONS AND OWNER S MANUAL PORTABLE BUDDY RADIANT HEATER

START-UP AND CLEAN-UP PROCEDURES

c. Oko-Tex (European environmental health standard)

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Equipment Specifications / Applications Guidelines

PLD3151S. Assembling & Use && Maintenance Manual Manual. Electric Spray Gun. English WARNING: READ INSTRUCTIONS MANUAL BEFORE USING USING PRODUCT.

Maxit. Operation and Maintenance Manual

TERRACE AND PATIO HEATER HLB-2400/ 2650 SERIES

INSTALLATION GUIDE Novitherm TM heat reflector panels

Rhinoskin Spray On Insulation Ceramic Insulation Coating

Installation Manual EF5000 AUS & NZ

HW-17 Record Cleaning Machine Setup and Instruction Manual

CONTENTS. Fuji Limited 2 Year Warranty

Propane Flame Projector Safety instructions and operating manual

INSTRUCTION MANUAL. UBES60SS2 60cm 4 Solid plate electric hob

by PRIMUS Portable Buddy Compact Propane Heater User Manual and Product Specifications

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Important Information

Care and Use Instructions

INSTALLATION GUIDE AND CHECKLIST

Product 3M Fastbond 3M Fastbond. Base: Polychloroprene Polychloroprene

Hardscape Cleaning. Hardscape Cleaning Protocol with EaCo Chem, Inc.

Transcription:

SPRAYING MANUAL Quin Global UK Unit 1, Ruthvenfield Avenue Inveralmond Industrial Estate Perth, PH1 3WB www.quinglobal.com www.tensorglobal.com sales.uk@quin-global.com 0845 381 22 33 Adhesives That Outperform

CONTENTS Spray Patterns Preparation Application Bonding Techniques Changing to a New Canister Disposing of an Empty Canister

SPRAY PATTERNS PREPARATION IDENTIFYING SPRAY PATTERNS **IMPORTANT** ALWAYS CHECK WHAT TYPE OF SPRAY PATTERN YOUR ADHESIVE HAS BEFORE SPRAYING. 1. Screw the larger hose nut to the gun thread (clockwise) and fully tighten with a spanner. Check hose is securely attached. TYPES OF SPRAY PATTERN It is imperative that you ensure what type of spray pattern the adhesive will be released from the container in; failure to identify this can lead to improper applications and undesired results. To confirm the product s spray pattern, simply check the label and a property icon (like the one pictured left and listed below) will indicate this. 2. Screw the smaller hose nut to the canister (clockwise) and fully tighten with a spanner. Check the hose is securely attached. WEB SPRAY MIST SPRAY PEBBLE SPRAY SNOWFLAKE SPRAY Description: The easiest visual comparison that can be made to a Web spray is that of a spider s web, hence the name! Description: Mist spray adhesives are released from the container as a fine mist, which creates a light and consistent droplet pattern on the surface it is sprayed upon. Description: Pebble sprays are similar to Mist sprays however the pattern is made up of larger droplets, but still giving a smooth and consistent pattern on the surface. Description: Snowflake spray adhesives have a High build, large flake spray pattern which resemble snowflakes across the surface for single-sided bonds. 3. Turn on the valve on the canister anticlockwise until fully open. Check connections for any leaks and if any occur tighten connections. DO NOT TURN THE CANISTER VALVE OFF UNTIL THE CANISTER IS EMPTY (this is to prevent the adhesive curing in the hose and gun). 4. On initial use, or if the product has been standing for more than 12 hours, the hose and gun may require a purge. Do this by pulling the trigger and adjusting the flow by turning the adjustment screw at the back of the gun (anticlockwise to open and clockwise to close). Dispense and discard adhesive until a consistent spray pattern is achieved.

WEB SPRAY

WEB SPRAY BONDING TECHNIQUES 1. Prepare the surface to be bonded; ensuring Do not angle spray gun or move in an arc both faces are clean, free of dust, dirt while spraying. Hold gun at 90 to surface and grease. If necessary wipe clean with while spraying. Release trigger at end of proprietary solvent-based cleaner. DO NOT each pass to optimize coverage. USE WHITE SPIRIT, METHYLATED SPIRITS OR CITRUS-BASED CLEANERS. Many man-made boards such as plywood and especially flexi-ply and MDF are very absorbent and will need a primer coat (shown in COVERAGE TOO LIGHT picture). Allow to dry, then apply the normal 2. Hold spray gun at a constant distance of CORRECT APPLICATION, as shown, over between 100-250mm (4-10 ) from the COVERAGE TOO LIGHT top of primer coat. surface, allowing the adhesive to web across the surface with approximately 50- Many substrates should be regarded as 70% overlap to successive passes for thin difficult to bond, e.g. metal faced HPL, laminates to reduce risk of telegraphing (note Colorcore etc. or products with memory correct coat weight must be achieved). (also soft and thick materials may require 2nd or 3rd coat). Best results are obtained by multiple coats rather than one heavy coat which may result in heavy wetting 3. Maintain a constant speed of application of surface and extended drying times. during spraying, applying a consistent Always test before using in production see and thorough coating without allowing disclaimer. COVERAGE TOO HEAVY the adhesive to puddle or heavily wet the surface. Maximum bond strength is achieved Allow adhesive to dry (see product data with coverage of between 80-100%, and a sheets for appropriate drying times). Test for recommended minimum coat weight of 20 dry dryness using back of hand only; surface grams per m2. should be tacky but adhesive should not transfer to skin. Position substrates correctly and press together working from centre 4. Maximum adhesion will be obtained by outwards. Apply adequate pressure using spraying mating faces at 90 to each other, i.e. nip roller or 75mm hand roller and body one face vertically, the other face horizontally. weight as a minimum in order to achieve at Double coating perimeter of face and edges least 35psi at glue line. Note; repositioning is recommended, including areas around is not possible after contact has been made. CORRECT APPLICATION = 20 dry gms/sqm subsequent cutting positions. Immediate trimming/routing is possible. Full strength is achieved after 24-48 hours depending on temperature and humidity. 75mm HAND ROLLER

PEBBLE/MIST SPRAY

PEBBLE/MIST SPRAY BONDING TECHNIQUES 1. Prepare the surface to be bonded; ensuring Do not angle spray gun or move in an arc both faces are clean, free of dust, dirt while spraying. Hold gun at 45 to surface and grease. If necessary wipe clean with while spraying. Release trigger at end of proprietary solvent-based cleaner. DO NOT each pass to optimize coverage. USE WHITE SPIRIT, METHYLATED SPIRITS OR CITRUS-BASED CLEANERS. Many man-made boards such as plywood and especially flexi-ply and MDF are very absorbent and will need a primer coat (shown in COVERAGE TOO LIGHT picture). Allow to dry, then apply the normal 2. Hold spray gun at a constant distance of CORRECT APPLICATION, as shown, over between 200-400mm from the surface, COVERAGE TOO LIGHT top of primer coat. allowing the adhesive to droplet across the surface with approximately 50-70% overlap Many substrates should be regarded as to successive passes for thin laminates to difficult to bond, e.g. metal faced HPL, reduce risk of telegraphing (note correct Colorcore etc. or products with memory coat weight must be achieved). (also soft and thick materials may require 2nd or 3rd coat). Best results are obtained by multiple coats rather than one heavy coat which may result in heavy wetting 3. Maintain a constant speed of application of surface and extended drying times. during spraying, applying a consistent Always test before using in production see and thorough coating without allowing disclaimer. COVERAGE TOO HEAVY the adhesive to puddle or heavily wet the surface. Maximum bond strength is achieved Allow adhesive to dry (see product data with coverage of between 80-100%, and a sheets for appropriate drying times). Test for recommended minimum coat weight of 20 dry dryness using back of hand only; surface grams per m2. should be dry and adhesive should not transfer to skin. Position substrates correctly and press together working from centre 4. Maximum adhesion will be obtained by outwards. Apply adequate pressure using spraying mating faces at 90 to each other, i.e. nip roller or 75mm hand roller and body one face vertically, the other face horizontally. weight as a minimum in order to achieve at Double coating perimeter of face and edges least 35psi at glue line. Note; repositioning is recommended, including areas around is not possible after contact has been made. CORRECT APPLICATION = 20 dry gms/sqm subsequent cutting positions. Immediate trimming/routing is possible. Full strength is achieved after 24-48 hours depending on temperature and humidity. 75mm HAND ROLLER

CHANGING TO A NEW CANISTER DISPOSING OF AN EMPTY CANISTER IMPORTANT: SAFETY GLASSES AND GLOVES MUST BE PUT ON BEFORE STARTING THE DISPOSAL PROCESS 1. Turn off the valve on the canister anticlockwise until fully closed. 2. Pull the trigger on the gun and hold for 10 seconds to expel residual pressure. 1. Lay the empty canister on its side with the valve pointing AWAY from the operator, and well away from sources of ignition. 2. Open the canister valve (anti-clockwise) and release any residual pressure. 3. Unscrew the hose nut and disconnect the hose from the empty canister (move to next page for canister disposal). 3. Stand canister upright. Use a hammer and brass punch or other non-sparking instrument to puncture the friable disc. 4. As long as the user is able to accept responsibility for de-pressurising the canister, it can be disposed of as per your normal scrap metal disposal (subject to local waste restrictions). 4. Connect the hose and gun to the new canister (go to Step 2 of PREPARATION and follow the process through to Step 4). TRANSPORT INFORMATION During transport, the recommended PPE (Refer to MSDS), First Aid Kit and suitable Fire Extinguisher should be readily accessible in the vehicle. IMPORTANT NOTE: THIS PROCESS SHOULD BE FOLLOWED THROUGH IMMEDIATELY AND ADHESIVE SHOULD BE DISPENSED FROM THE NEW CAN OR THE GUN AND HOSE WILL BLOCK AND BECOME UNUSABLE. Keep vehicle well ventilated at all times whilst it contains TensorGrip Spray Contact Adhesive. Secure canister during transportation. If you are not transferring the hose and gun to a new canister you will need to clean it to ensure it can be used again on future jobs. GUARANTEE Before using the product, the user should carry out any necessary tests in order to ensure that the product is suitable for the intended application. Moreover, all users should contact the seller or the manufacturer of the product for additional technical information concerning its use if they think that the information in their possession needs to be clarified in any way, whether for normal use or a specific application of our product. Our guarantee applies within the context of the statutory regulations and provisions in force, current professional standards and in accordance with the stipulations set out in our general sales conditions. The information detailed in the present technical data sheet is given by way of indication and is not exhaustive. The same applies to any information provided verbally by telephone to any prospective or existing customer.

CONTACT If you are having trouble with one of our products or if you require any further information, please don t hesitate to get in touch. Call: 0845 381 22 33 E-mail: sales.uk@quin-global.com Visit: www.tensorglobal.com www.quinglobal.com Quin Global UK Unit 1, Ruthvenfield Avenue Inveralmond Industrial Estate Perth, PH1 3WB