Securing your safety

Similar documents
- CONSTRUCTION FIRE SAFETY STANDARDS

- CONSTRUCTION FIRE SAFETY STANDARDS

National Fire Authority


Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Maintenance of Fire Systems

Howler Go-Link Evacuation Alarm

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

H&S Forum. Fire Safety Policy Glascote Academy

Cygnus Wireless Alarm System

FIRE SAFETY POLICY. Executive Management Team. Health, Safety and Fire Steering Group.

Guidance Document on Caravan and Camping Sites Fire Safety Equipment Requirements

Managing Fire Safety Through Construction. Reece Walker Arup Fire Engineer

UK Timber Frame Association

Fire Safety Policy. Signed Date September on behalf of the Management Committee. on behalf of The Woodlands

New Fire Safety Order

FIRE SAFETY FOR PRE-SCHOOLS AND CHILDCARE FACILITIES GENERAL GUIDANCE COUNTY COMMITTEE LIMERICK CHILDCARE

WARM WELCOME RISK ASSESSMENTS & HOMESTAY FIRE/GAS SAFETY

Guide to choosing the right portable Fire Extinguisher. Produced in association with the UK Fire Association

Millfield Schools Fire Risk Prevention Policy

Fire Risk Assessment 2016

FIRE RISK ASSESSMENT

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

FIRE POLICY ST.GEORGES AND OUR LADY QUEEN OF PEACE PARISHES OF WORCESTER INTRODUCTION. Fire is one of the most common workplace hazards.

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System

Cadet Entry Level Award(ELA) Part Four. Fire Safety

UNIVERSITY COLLEGE LONDON PREMISES FIRE SAFETY HANDBOOK. Regulatory Reform (Fire Safety) Order 2005 DARWIN BUILDING

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

TECHNICAL SPECIFICATION FOR FIRE DETECTION & ALARM SYSTEM INCLUDING FIRE EXTINGUISHERS

Design Guidelines Fire Safety in New and Refurbished Buildings

The Mungo Foundation. Fire Safety Policy and Procedure

Fire Safety Policy and Procedure

Extinguishers. Commercial Industrial High rise buildings

Princess Court Cornbrook Park Road Old Trafford Manchester M15 4FE

University of London

A basic guide to... Fire Safety for Scout Premises

BS Selection and positioning of portable fire extinguishers. Click Arrow to Start

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

1. A fire certificate is issued under Section 76 of the Occupational, Safety and Health ActNo. 28 of 2005.

The Social Accountability International (SAI) Fire Safety Checklist

FIRE SAFETY INSPECTION REPORT

16 Steps to fire safety. Promoting good practice on structural timber construction sites Version 4.1 May 2017

Construction Products Regulation (CPR) Update. Graham Simons Technical Manager, FIA

Fire Safety Awareness Workbook

Fire risk management plan. MH/05/Revised/06/17

GDST Fire Safety Strategy March 2016

Fire Risk Assessment Guidance

EAST DEAN & FRISTON VILLAGE HALL FIRE RISK ASSESSMENT

FIRE RISK ASSESSMENT

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

Your specialist partner for total electrical compliance. Electrical Testing

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

Fire Risk Assessment Borough High Street

FIRE SAFETY AWARENESS

Fire on construction sites. A guide to loss prevention

Peponi House Preparatory School Nairobi, Kenya. Peponi House Fire Risk Prevention Policy

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

FIRE SAFETY INSPECTION REPORT

Employers Responsibilities

Basic Fire Safety Awareness Training.

Fire Risk Assessment. Guidance Notes. Location details. Risk Rating. Assessors. General notes

FIRE SAFETY INSPECTION REPORT

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

Fire Risk Assessment 2017

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

NEW. ECO WELFARE UNIT Compact. Sustainable. Portable.

PREMISES FIRE SAFETY LOGBOOK

Fire Risk Assessment - HMO (including accommodation with integrated fire systems)

Fun Foundations Day Nursery Fire Safety Risk Assessment

Fire Risk Assessment

THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514)

1970s building housing main school reception and support offices. Well managed buildings with no significant risk of a fire occurring.

South Australian Regulatory Requirements

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire

'Safety, Signs and Signals' Results For JOE BLOGGS. Safety, Signs and Signals. Summary

FIRE SAFETY MANAGEMENT PLANS DEVELOPMENT GUIDE A GUIDE TO DEVELOPING

THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS

FIRE SAFETY RISK ASSESSMENT

OAKTHORPE PRIMARY SCHOOL FIRE RISK ASSESSMENT POLICY NOVEMBER 2016

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

Well managed building mean risk is normal. Fire action notices should be displayed by all alarm break glass call points.

Date Issued: December 14, 2017 Revision: 2.1

Design and Supply of Fire Equipments. External Fire Fighting Systems.

Emergency Response Procedures Contractors Instruction. Building nformation

Fire Safety. A TUC guide for trade union activists

IFC Significant Changes from the 2009 to the 2015 Edition Tier 1

Standards: Issues and Challenges

Paddy McDonnell P.I.I.E., H.Dip.SHWW., Grad. IOSH., G.I.Fire.E., MIITD.,MNFPA Technical Director Phoenix Safety Training Services

Fire Safety Plan Information. For Construction and Demolition Sites

PREMISES FIRE SAFETY HANDBOOK

Fire Safety Policy Date: 0

Reliance Fire Protection Systems

Bristol City Council Private Rented Sector Fire Safety Standards

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Fire Safety Register

Ruishton C of E Primary School

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

1.4 Provide and fix the following ironmongery.

Transcription:

working with

FIRE STATISTICS There are around 11 construction site fires everyday in the UK Estimated costs to the industry are 400m per year, or over 1m a day! All sites and buildings under construction are susceptible to fire Blazes occur regardless of simplicity or complexity of the project at hand. The dangers of construction site fires are material: they destroy property and equipment, cost money, and delay or even permanently halt projects. But much more importantly, fires cost lives.

Fire Safety Legislation HSE Fire Safety Guidelines for construction sites (HSG168; 223) HSG168 is relevant to all construction projects aimed at all with a role in developing, managing and applying safety standards on site. Covers location of materials FPA, CC, JCOP It s a code to prevent fires on construction site, to protect not only the buildings but also the occupants Distribution panels, amount of protection required, servicing intervals and other hazards on site.

Fire Safety Legislation The Structural Timber Association s 16 Steps to Timber Frame Construction document. Guidance for all involved in the design, manufacture and erection of timber frame buildings. It represents the strongest recommendations and advice for all clients Electrically operated fire warning devices must always be used in timber frame. These devices should be linked to detection devices strategically places around the structure. British Standards Institution works closely with the FIA to supply a range of fire safety standards from emergency lighting, to fire detection and alarm systems, and fixed firefighting equipment. BS5839 (locating and servicing and alarms) BS 5306 (Locating and servicing extinguishers)

Development of Fire Safety 2017 2007 7

+ 32 other

Current Challenges In Construction Government Regulation Lack of Training Time Constraints Rising Costs

Best Practice

Onsite Fire Safety Recommendations HOUSING As a g uide there should be 1 fire point every 30m or every 6 houses that are under construction. For example a project with 100 units may actually only be building 6-8 units at each phase; therefore only 1 fire point trolley will be required which can be moved around as the site progresses. Wheeled Fire Point Trolley, c/w: Double Contractor Trolley 9kg Powder Extinguisher 9ltr Foam Extinguisher Extinguisher ID, Fire Point & Fire Action Signag e Suitable Alarm can be a wireless standalone or radio-linked versions which have to be audible above the noise of a construction site. APPARTMENTS Ref JCOP 9th Edition Page 16, point 11.3 Exting uishers must be located in conspicuous positions near to exits on each floor. Wheeled Fire Point Trolley, c/w: Double Contractor Trolley 9kg Powder Extinguisher 9ltr Foam Exting uisher Exting uisher ID, Fire Point & Fire Action Signage Suitable Alarm can be a wireless standalone or radio-linked versions which have to be audible above the noise of a construction site.

Onsite Fire Safety Recommendations TIMBER FRAME Considered a high risk environment. Ref JCOP 9th Edition page 27 Point 23.15 Automatic fire detection must be provided as set out in section 13; these systems must be linked to an alarm receiving centre unless there is a 24 hour security presence on site. Wheeled Fire Point Trolley, c/w: Double Contractor Trolley 9kg Powder Exting uisher 9ltr Foam Extinguisher Extinguisher ID, Fire Point & Fire Action Signage Cygnus Fire Alarm System inc. Call Points, Heat Detectors and Control Panel An Auto Dialler may be required if 24hr site security presence is not available. HIGH RISE Ref JCOP 9th Edition page 22.1 point 22.8 In these circumstances a specific fire risk assessment should be undertaken to develop appropriate provisions. Electrically operated fire alarm systems must be provided throughout the heig ht of the building, comprising breakglass (or similar) call points and sounders on all levels, plus a link to a permanently occupied security office (or similar). Hard wired systems or radio operated wireless systems of proven reliability, performance and coverage are also acceptable. Wheeled Fire Point Trolley, c/w: Double Contractor Trolley 9kg Powder Extinguisher 9ltr Foam Extinguisher Extinguisher ID, Fire Point & Fire Action Signag e Cygnus Fire Alarm System inc. Call Points, Heat Detectors and Control Panel An Auto Dialler may be required if 24hr site security presence is not available.

Onsite Fire Safety Recommendations ELECTRICAL EQUIPMENT E.G. Distribution panels; Ref JCOP 9th Edition Page 15 point 9.6 PLANT & MACHINERY HSG168 Plant & Equipment, pag e 72 Mobile plant should be fitted with an appropriate fire exting uisher (e.g. 1 or 2kg Powder) To protect distribution panels and items of electrical equipment, appropriate exting uishers (such as those containing carbon dioxide) must be provided close to the equipment concerned. JCOP 9th Edition Page 16 point 11.7 Ride-on mechanically propelled site plant should carry an appropriate fire exting uisher where reasonably practicable. - 5kg / 2kg CO2 Fire Exting uisher - 1kg / 2kg Powder Fire Exting uisher

Onsite Fire Safety Recommendations HOT WORKS E.G. Welding or Tar Boilers Adequate spare extinguishers should always be available to cover any hot works. In this regard special caution and provision should be allowed for when tar boilers are to be used; JCOP 9th Edition Page 21 point 16.13(e) The following precautions should be applied when using tar boilers: (e) at least two appropriate fire extinguishers must be to hand; SMOKING AREAS JCOP 9th Edition Pag e 25 Smoking 21.2 (e) Where a smoking shelter is provided it must be: (e) provided with a suitable fire extinguisher. Sing le Fire Exting uisher Stand or Trolley 6Ltr Foam Fire Exting uisher c/w signage 9Kg Powder Fire Exting uisher 9Ltr Foam Fire Exting uisher

Onsite Fire Safety Recommendations TEMPORARY ACCOMODATION UNITS (TAUs) Canteen c/w Full Cooking Facilities (where cooking oils are used) Basic Site Office / Meeting Room Site Office c/w Kitchenette/ Basic Canteen Drying Room Double Fire Exting uisher Stand 6Ltr Wet Chemical Fire Exting uisher 2kg CO2 Fire Exting uisher Fire Blanket Fire Exting uisher and Fire Blanket ID Sig nage Double Fire Exting uisher Stand 6Ltr Foam Fire Exting uisher 2kg CO2 Fire Exting uisher Fire Extinguisher ID Sig nag e Double Fire Extinguisher Stand 6Ltr Foam Fire Extinguisher 2kg CO2 Fire Exting uisher Fire Blanket Fire Exting uisher and Fire Blanket ID Sig nag e Double Fire Extinguisher Stand 6Kg Powder Fire Exting uisher 6Ltr Foam Fire Exting uisher Fire Exting uisher ID Sig nage Compound Area / Fuel Bowser Wheeled Fire Point Trolley that incorporates the following : 9Kg Powder Fire Exting uisher 9Ltr Foam Fire Extinguisher Fire Exting uisher ID and Fire Action Sig nag e Temporary Fire Alarm

Fire 360 12 Steps To Effective Fire Strategy