FIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator

Similar documents
Flammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm

INDEX FIXED FIRE FIGHTING SYSTEM. 1. High Pressure Co2 System. 2. Local Water Mist System. 3. Deck Foam System. 4. Dry Chemical Powder System

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

PRODUCT MANUAL FIRE EXTINGUISHER. Carbon Dioxide 6.5, 9 & 22.5 Kg Capacity Trolley Mounted (45 kg also as a non standard)

Extinguishers. Commercial Industrial High rise buildings

PRESTO DRY POWDER FIRE EXTINGUISHERS - AB:E

OUT CARBON DIOXIDE (CO2) EXTINGUISHER Certified & Approved to AS/NZS Lightweight Aluminium Cylinder. AS High pressure hose assembly with

FIREWORLD DRY POWDER ABE FIRE EXTINGUISHERS

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

Design and Supply of Fire Equipments. External Fire Fighting Systems.

Technical Data Sheet No. JS-SM-38 DOCUMENT TITLE 3.5KG CARBON DIOXIDE FIRE EXTINGUISHERS

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

w w a. m o c. x e r fi. w u

Foam Wheeled Extinguisher AB Movable fire extinguishers

OPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST

Government of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE

A full range of UK manufactured portable and wheeled fire extinguishers

Portable Fire Extinguishers

Industrial Fire Brigade

HRS035-MS-022-RD 22 (559mm) 19mm x 30m 310mm Fixed Manual. HRS037-GI-019-RD 19 (483mm) 19mm x 36m 350mm Swing Manual

Tender document for Supply/ Installation of New Fire extinguishers & Refilling TENDER NOTICE

Technical Data Sheet No. JS-SM-33 DOCUMENT TITLE. 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2.

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

NUCLEAR POWER CORPORATION OF INDIA LIMITED (A Government of India Enterprise)

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

Operation Refilling and Maintenance Manual SFS-10. Hatsuta Seisakusho Co. Ltd. SFS-10-E1404-(A-012)

HD 6/13 C. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 3 Accessory storage

FIRE EXTINGUISHER. Automatic / Dry Powder, Foam, Co2, Wet Chemical, Trolley Extinguishers


Portable Fire Extinguishers

Risk Management Resources

Institute for Plasma Research Welcomes you all on

Fight or Flee? Extinguisher Basics Extinguisher Use Extinguisher Placement and Spacing Hydrostatic Testing OSHA Requirements Test Your Knowledge

DATASHEET HIGH VOLUME LONG RANGE FOAM MONITOR GPM

IGS-M-SF-01(0) IGS. Iranian Gas Standards. CO2 Fire Extinguisher, Portable Type

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

Subchapter 7. General Industry Safety Orders Group 27. Fire Protection Article 157. Portable Fire Extinguishers. Return to index New query

Cold water compact class HD 6/13 C Plus *EU

Attachment 1. to ClassNK Technical Information No.TEC-0764 Malta Maritime Authority Date Revised 28 August 2008 Page 1 of 10 This Administration Requi

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle.

K 2 Compact. K 2 Compact, ,

Spare parts list ( ) Spare parts list PUZZI 100 *USA

GUILFORD COUNTY SCHOOLS

The Specialist s Choice

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 7 Extinguisher Types Revised

Spare parts list ( ) Spare parts list PUZZI 100

GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES

Appliance Bottom Model :97100 DE 4002 Steam Cleaner (Chemical-Free)

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

Fire Extinguisher Use. Fire Extinguisher Review. and Fire Safety

Spare parts list ( ) Spare parts list Priza

R7521SS COLORS/FINISHES. Stainless Steel 21 15/16" 1 3/16" 8 5/64" 1 25/32" 2 1/8" 23 5/8" Max. 1 3/8" G1/2" Female

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

PROFESSIONAL SUPPLIER

Tank Washing Machines. globally focused on cleaner solutions

COMPONENT MAINTENANCE MANUAL

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

R7520SS COLORS/FINISHES. Stainless Steel 16 9/16" 7 15/16"

Fixed Fire Extinguishing Equipment and Systems

WHAT IS FIRE? In order to have a fire, there must be three elements: Heat -- enough to make the fuel burn

RULES FOR STATUTORY SURVEY OF SEA-GOING SHIPS. FIRE-FIGHTING EQUIPMENT AND ESCAPE EQUIPMENT 2017 January

K Air Con. Induction motor regulation and swivel-mounted joint. Vario Power Jet Short 360 with infinitely variable pressure

FIRE EXTINGUISHER SERVICING & MAINTENANCE INSTRUCTIONS

Cold water compact class HD 5/12 C

HD 5/12 C + Mobility. Accessory storage

Cold water compact class Xpert HD 7125 *AU. Standard accessories: High-pressure hose 10 m Spray lance 380 mm Anti-twist system Pressure cut-off

Mobile hot water pressure washers

Capital Projects Group Fire Extinguishers Specification

LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM

WHY CHOOSE AN EXTREME DUTY MULTI VAC INDUSTRIAL VACUUM SYSTEM?

ENGINEERING STANDARDA FOR FIRE FIGHTING HOSE BOX AND / OR SHELTER ORIGINAL EDITION NOV. 1993

Portable Fire Extinguishers

Portable & Mobile Fire Extinguishers MARINE EQUIPMENT DIRECTIVE (MED - WHEELMARK) 2017 EDITION 1

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

Cold water HD 9/18-4 ST

Salt Lake Community College FIRE EXTINGUISHER TRAINING

FIRE EXTINGUISHERS & CHEMICAL

Mobile cold water pressure washers POSEIDON 4

Attachment 1. to ClassNK Technical Information No. TEC-1077 Isle of Man Ship Registry Manx Shipping Notice SOLAS II-2 The Maintenance and inspection o

Cold water compact class HD 5/15 C

Mobile hot water pressure washers NEPTUNE 7

Professional mobile cold water

Twin-Agent Fire Fighting/Securing Systems Specifications

K K 2.350, ,

K K 2.120, ,

K Specifications. Max. Water Volume

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

THÔNG BÁO KỸ THUẬT TÀU BIỂN TECHNICAL INFORMATION ON SEA-GOING SHIPS

With combustion engine HD 801 B. Equipment: Trigger gun Extended highpressure. Technical data

K 2 Compact Car. Hooked on tidiness. Sits comfortably in the hand. Integrated accessory storage on the device. Full cleaning power

K 2 Compact. Hooked on tidiness. Sits comfortably in the hand. Full cleaning power

K 4 Compact. K 4 Compact, ,

Mod. 140 Suction/Discharge syringe Ø 40mm - Capacity 250cc. Mod. 150 Suction/Discharge syringe Ø 50mm - Capacity 500cc

PLUS SIZE EXTINGUISHERS CEASEFIRE PLUS

Guidance on the construction of CO 2 systems

Transcription:

FIRE EXTINGUISHERS Chapter 2 - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator

CO2 FIRE EXTINGUISHER - Dielectric test at 35000 V at 1mtr distance. - Use on electrical equipment up to 1000 v at 1 mtr distance min. - Paint : Epoxy Coating RAL 3000 - Discharge Hose : Rubber SBS hose reinforced with steel wire - Extinguishing Agent : Carbon dioxide is a odorless and color less gas. Weigh about 1.5 times the air - Use : Pick up the extinguisher from the wall hanger and keep it in hand at the inferior leverage. Pull out the safety pin from the valve and keep in the other hand the handle of the horn. Squeeze the upper lever of the valve and aim the jet at the base of the burning material, sweep the extinguishing agent right and left uniformly in the fire. Technical Data Model Type Cap. Temperature Disch. Time Jet Length Working Test Net Weight Width (mm) Heigh t 14251 Co2 5kg -30 +60 14s 3m 51.7 bar@20 250bar 15kg 180 785 - Note : Mounting bracket available on request

CO2 FIRE EXTINGUISHER 1 Frame of the trolley 2 Cylinder 27Ltr 3 3/4" Handwheel valve 4 Siphon tube 5 Discharge hose 6 Discharge apparatus 7 Carvon dioxide 8 Wheel 300mm 9 Safety pin 10 Washer ring fibre 11 Protection cap 12 Safety disc 13 Swivel coupling 3/8" Specification - Type : Stored pressure type - Capacity : 20Kg - Fire Rating : B - Material : Steel 34CrMo4 - Cylinder : 230mm - Dimension : H 965mm x W 410mm x D 600mm - Operating Pressure : 60 Bar at 20 - Test Pressure : 250Bar according 97/23/EC - Temperature Range : -30 + 60 - Extinguisher Agent : Carbon Dioxide - Propellant : Carbon Dioxide - Total Weight : 68 Kg - Range of Discharge : 4 Mtr - Discharge Time : 32 Sec.

POWDER FIRE EXTINGUISHER - Dielectric test at 35000 V at 1mtr distance. - Use on electrical equipment up to 1000 v at 1 mtr distance min. - Paint : Epoxy polyester powder coating RAL 3000 U.V - Discharge Hose : Rubber hose reinforced textiles - Internal Cartridge : Capacity 55g, high pressure seamless steel, tested at 250 bar - Extinguishing Agent : Dry powder produced according to EN615 & ISO9000. Not corrosive, abrasive and toxic for humans & animals - Use : Pick up the extinguisher from the wall hanger and keep it in hand at the inferior leverage. Pull out the safety pin from the valve and keep in the other hand the handle of the horn. Squeeze the upper lever of the valve and aim the jet at the base of the burning material, sweep the extinguishing agent right and left uniformly in the fire. Technical Data Model Type Cap. Temperature Disch. Time Jet Length Working Test Net Weight Width (mm) Heigh t 14167 Powder 6kg -30 +60 18s 7m 13 bar@20 26bar 11kg 190 560 Spare Part Product No. Internal CO2 cartridge 21060 Dry Powder ABC 31150 - Note : Mounting bracket available on request

POWDER FIRE EXTINGUISHER - Dielectric test at 35000 V at 1mtr distance. - Use on electrical equipment up to 1000 v at 1 mtr distance min. - Paint : Epoxy polyester powder coating RAL 3000 U.V - Discharge Hose : Rubber hose reinforced textiles - Internal Cartridge : Capacity 55g, high pressure seamless steel, tested at 250 bar - Extinguishing Agent : Dry powder produced according to EN615 & ISO9000. Not corrosive, abrasive and toxic for humans & animals - Use : Pick up the extinguisher from the wall hanger and keep it in hand at the inferior leverage. Pull out the safety pin from the valve and keep in the other hand the handle of the horn. Squeeze the upper lever of the valve and aim the jet at the base of the burning material, sweep the extinguishing agent right and left uniformly in the fire. Technical Data Model Type Cap. Temperature Disch. Time Jet Length Working Test Net Weight Width (mm) Heigh t 14194 Powder 9kg -30 +60 20s 7m 13 bar@20 26bar 16kg 200 545 Spare Part Product No. Internal CO2 cartridge 20208 Dry Powder ABC 31140 - Note : Mounting bracket available on request

FOAM FIRE EXTINGUISHER - Dielectric test at 35000 V at 1mtr distance. - Use on electrical equipment up to 1000 v at 1 mtr distance min. - Paint : Epoxy polyester powder coating RAL 3000 U.V - Discharge Hose : Rubber hose reinforced textiles - Internal Cartridge : Capacity 55g, high pressure seamless steel, tested at 250 bar - Extinguishing Agent : Special formula AFFF based, by the interaction of two extremely powerful product, reaching very high performance specially agent class A, B and F fire. - Use : Pick up the extinguisher from the wall hanger and keep it in hand at the inferior leverage. Pull out the safety pin from the valve and keep in the other hand the handle of the horn. Squeeze the upper lever of the valve and aim the jet at the base of the burning material, sweep the extinguishing agent right and left uniformly in the fire. Technical Data Model Type Cap. Temperature Disch. Time Jet Length Working Test Net Weight Width (mm) Heigh t 14392 Foam 9L 0 +60 34s 5m 15bar @20 30bar 15kg 225 540 Spare Part Internal CO2 cartridge Foam Liquid, AFFF 17% Product No. 20177 33396 - Note : Mounting bracket available on request

FOAM FIRE EXTINGUISHER 1 Cylinder 64 Ltr 2 Valve with safety valve 3 Handwheel valve 4 CO₂cylinder 5 Adaptor for CO2 cylinder 6 Foam nozzle 7 Trigger valve brass 8 Discharge hose 5 mtr 9 Wheels rubber and plastic 10 Sealfire 11 Washer ring fiber 12 Manometer 13 Plastic seal 14 Washer ring 15 Siphon tube 16 Safety valve 17 Filter + coupling 18 Cap for protection foot cylinder Specification - Type : Cartridge type - Capacity : 50 Ltr - Capacity : 50 Ltr - Fire Rating : A, B - Cylinder : 300 mm (0 ~ 15mm) - Dimension : H 1145mm x W 455mm x D 550mm - Operating Pressure : 13 Bar at 20 - Test Pressure : 30 Bar according 97/23/EC - Temperature Range : + 0 + 60 - Extinguisher Agent : Sealfire 2% (AFFF) - Propellant : CO₂3 Ltr - Total Weight : 85 Kg - Range of Discharge : 8 Mtr - Discharge Time : 47 Sec. - Note : Available antifreeze - 20 or - 30 & available with hose 10 mtr length on request.

FOAM FIRE EXTINGUISHER 1 Cylinder 180Ltr 2 Valve with safety valve 3 Handwheel valve 4 Co2 cylinder 5 Adaptor for CO2 cylindet 6 Foam nozzle 7 Trigger valve 8 Discharge hose 5 Mtr 9 Wheels rubber and plastic 10 Sealfire 11 Washer ring fibre 12 Manometer 13 14 15 16 17 18 Plastic seal Washer ring Siphon tube Filter & Coupling Washer black rubber Safety vavle 19 Cap for protection foot cylinder Specification - Type : Cartridge type - Capacity : 150 Ltr - Fire Rating : A, B - Cylinder : 450mm - Dimension : H 1380mm x W 700mm x D 900mm - Operating Pressure : 13 Bar at 20 - Test Pressure : 30 Bar according 97/23/EC - Temperature Range : + 0 + 60 - Extinguisher Agent : Sealfire 2% (AFFF) - Propellant : CO₂6,7Ltr - Total Weight : 230 Kg - Range of Discharge : 8 Mtr - Discharge Time : 150 Sec. - Note : Available antifreeze - 20 or - 30 & available with hose 10 mtr length on request.

FOAM APPLICATOR The portable foam applicators are a supplement to the foam monitors and are supplied in accordance with specified requirements. Sheltered areas not reachable by the foam monitors can be covered by a foam appli-cator. This gives increased flexibility. Different applicators are available, covering varying needs for proportioning ratio, capacity and working pressure for particular vessel. Typically, an applicator needs to be supplied with a fire hose and a foam concentrate container and is stored in a foam station on deck or engine room. Compliance - Oil tankers : The system complies with the requirements in SOLAS Ch.II-, regulation 6. - Chemical tankers : IMO International Code for the Construction and Equipment of Ships Carrying Dimension Coupling Optional Specification - Type : Low expansion branch pipe - Material : Pipe : Stainless steel Casing : Brass Valve : Nickel-plated brass Hose & Suction pipe : Plastic - Connection : 1 1/2" BSP female thread - Faom expansion ratio : Up to 1:15 - Capacity : 215 l/min @ 6 bar - Weight : 4 Kg