P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

Similar documents
FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

FG-L Technical Data Sheet

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

P/N _F NSF Certified June 2010

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

PWEE Technical Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

RLNIE with INNOVATOR II

RL with INNOVATOR II No Heat Doors

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

RM with INNOVATOR Doors

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

RLT with INNOVATOR Doors

Nosing Heater. Return Grill Heater

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

Engineering Plan Views

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

RMN with INNOVATOR Doors Technical Data Sheet

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

LifeLine Premier RLNIE

LWU Technical Data Sheet

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

RL with INNOVATOR Doors

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

NFW, NCW, NFWG, NCWG, NFWE, NCWE

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

Installation & Service Manual

MD Medium Temperature Self Contained Open Vertical Merchandisers

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

Installation & Service Manual

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

MD Medium Temperature Self Contained Open Vertical Merchandisers

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

Medium Temperature Bulk Produce and Bakery Merchandisers

Installation & Service Manual

BCH Medium Temperature Merchandisers

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

Reach-in Merchandisers

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

F-6 Multi-deck Frozen Food Wall Merchandisers

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

Self-Contained MERCHANDISERS. February

RFLNS, RFMNS & RFLTM Freedom Line

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

Service Merchandisers

Ultra Low Front Rear Load Medium Temperature

EcoVision Door Manual

Self-Contained MERCHANDISERS. October

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

Service Merchandisers

Installation & Service Manual

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers

SERIES NAV S Display Merchandisers

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

RFLN & RFMN Freedom Line

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

Low Temperature. Installation & Operation Manual. Keep in store for future reference. Single Deck Wall & Island Merchandisers P/N F

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

ONRB ONRB. Narrow Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

Field Top Mounted Condensing Unit

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

Transcription:

FG Technical Data Sheet NSF Certified March 2017 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item Part # Description Wiring Item # FAN ASSEMBLIES, AND THERMOSTATS A. 4W Standard Energy Efficient Fan Assembly (1) 0477653 Fan Motor, Evaporator (MO.4410544) 0464847 Fan Blade (FB.4780649) B. Optional Adjustable Refrigeration Thermostat (2) C. 0398557 Defrost Termination Thermostat (3) (Electric Defrost only) (CT.4440611) D. 0481370 Heater Switch (4) (Koolgas Defrost only) (CT.4440738) HEATERS E. 208V Evaporator Defrost Heaters (5) 3016522 6 ft case (HE.4850620) 3016524 8 ft case (HE.4850603) 3016527 12 ft case (HE.4850571) Data sheet-excel-fg Item Part # Description Wiring Item # HEATERS (CONTINUED) F. 208V Drip Pan Defrost Heaters, Electric (6) 0444300 6 ft case (HE.4850609) 0462160 8 ft case (HE.4850636) 0444296 12 ft case (HE.4850572) 120V Drip Pan Defrost Heaters, Koolgas (7) 0465906 6 ft case (HE.4850628) 0465907 8 ft case (HE.4850622) 0465908 12 ft case (HE.4850623) G. Nosing Anti-sweat Heaters (8) 0495006 6 ft case (HE.4850684) 0495007 8 ft case (HE.4850685) 0495008 12 ft case (HE.4850686) H. Return Grille Anti-sweat Heaters (9) 0495010 6 ft case (HE.4850688) 0495011 8 ft case (HE.4850689) 0495012 12 ft case (HE.4850690) I. Return Glass Anti-sweat Heaters (10) 0489808 6 ft case (GL.4967587) 0474778 8 ft case (GL.4987838) 0474779 12 ft case (GL.4987839) Note: Revision K: Added high glide refrigerant note. Other changes marked by bar, underline or circle. 2017 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM Spanish P/N 0538911

Engineering Plan Views PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 11-2012 F / FG 3 in. (77 mm) Required Air Gap 41 ½ (1054) A B D 43 (1114) 4 ¼ (108) Dimensions shown as inches and (mm). 41 ½ (1054) 4 ½ (115) 8 (203) 24 (612) Electrical Field Concection Electrical Stub Up Area 6 x 6 (152 x 152) Waste Outlet Wireway 26 ½ (673) NOTE: Case-to-Case Electrical Comections are made IN FRONT OF SPLASHGUARD. 4 ¾ (120) Splashguard C FRONT Refrigeration Outlet Waste Outlet 10 (263) 26 ¼ (665) 12 (307) 30 ¼ (767) 31 (804) 33 ½ (851) 42 (1065) 6 ft 8 ft 12 ft General (A) Case Length (without ends or partitions) 73 3 /4 (1872) 96 3 /8 (2448) 144 1 /2 (3670) (Each end and insulated partition adds 2 in. (51 mm) to case line up.) Maximum O/S dimension of case back to front (includes bumper) 42 (1065) 42 (1065) 42 (1065) Back of case to front of splashguard 33 1 /2 (851) 33 1 /2 (851) 33 1 /2 (851) Back of case to O/S edge of front leg 30 1 /4 (767) 30 1 /4 (767) 30 1 /4 (767) Distance between edges of external legs and center legs 48 1 /2 (1232) 41 1 /2 (1054) 41 1 /2 (1054) Distance between edges of center legs NA NA 43 7 /8 (1114) Distance between front legs and splashguard 3 1 /8 (82) 3 1 /8 (82) 3 1 /8 (82) Electrical Service (Electrical Field Wiring connection point) (B) RH End of case to center of stub up area 58 3 /4 (1492) 84 1 /4 (2140) 132 3 /8 (3363) Back of case to center of stub up area 24 (612) 24 (612) 24 (612) Length of electrical wireway Wireway 26 1 /2 (673) 26 1 /2 (673) 26 1 /2 (673) (C) RH End of case to LH end of wireway 67 3 /4 (1720) 90 1 /8 (2289) 138 1 /4 (3511) Waste Outlets (One each end) (D) RH End of case to the center of LH waste outlet 61 1 /2 (1562) 84 1 /4 (2140) 132 3 /8 (3363) RH End of case to the center of RH waste outlet 12 1 /8 (307) 12 1 /8 (307) 12 1 /8 (307) Back O/S of case to center of waste outlets 31 5 /8 (804) 31 5 /8 (804) 31 5 /8 (804) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) Refrigeration Outlet Back of case to center of refrigeration outlet 26 1 /4 (665) 26 1 /4 (665) 26 1 /4 (665) RH end of case to center of refrigeration outlet 8 (203) 8 (203) 8 (203) 2 of 7 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 FG Technical Data Sheet

Single Deck Wall Display with Glass Front Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 2017 energy efficiency standards. Excel FG Dimensions shown as inches and (mm). 3 in. (77 mm) Required Air Gap REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75 F and 55% R.H. MED FF IC Discharge Air ( F) +24 12 22 Evaporator ( F) +19 20 30 Unit Sizing ( F) +17 23 33 Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. Btu/hr/ft MED FF IC Parallel 291 411 421 Conventional 306 431 441 Case-to-Case Connection Refrigeration Outlet FAN COIL DEFROST DATA MED FF IC Frequency (hr) 24 24 24 Defrost Water (lb/ft/day) 0.9 1.05 1.1 (± 15% based on case configuration and product loading). ELECTRIC MED FF IC Temp Term ( F) 48 48 48 Failsafe (minutes) 60 60 60 GAS Duration (minutes) NA 15 18 Estimated Charge ** 6 ft 1.5 lb 24 oz 0.7 kg 8 ft 2.0 lb 32 oz 0.9 kg 12 ft 3.0 lb 48 oz 1.4 kg **This is an average for all refrigerant types. Actual refrigerant charge may vary by approximately 0.5 lb (8 oz / 0.2 kg). NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. OFFTIME Not Recommended Standard Defrost Thermostat Close on rise: close 48 F open 33 F CONVENTIONAL CONTROLS Low Pressure Backup Control CI/CO * MED +12 F / +2 F FF 17 F / 29 F IC 27 F / 39 F Indoor Unit Only, Pressure Defrost Termination* Not Recommended *Use a Temperature Pressure Chart to determine PSIG conversions. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 7

Excel FG Electrical Data 6 ft 8 ft 12 ft Number of Fans 4W Evaporator 1 2 2 Amperes Watts 6 ft 8 ft 12 ft 6 ft 8 ft 12 ft Evaporator Fans 120V 50/60Hz Standard Energy Efficient 0.12 0.24 0.24 8 16 16 230V 50/60Hz Standard Energy Efficient 0.06 0.12 0.12 8 16 16 230V 60Hz Export 0.15 0.30 0.30 24 48 48 230V 50Hz Export 0.18 0.36 0.36 27 54 54 Anti-sweat Heaters (on fan circuit) 120V 50/60Hz Standard 0.65 0.87 1.30 78 104 156 230V 50/60Hz Export 0.34 0.45 0.68 78 104 156 Minimum Circuit Ampacity 120V 50/60Hz Standard Energy Efficient 0.97 1.31 1.74 230V 50/60Hz Standard Energy Efficient 0.60 0.77 1.00 230V 60Hz Export 0.69 0.95 1.18 230V 50Hz Export 0.72 1.01 1.24 Maximum Over Current Protection 120V 20 20 20 Maximum Over Current Protection 230V 15 15 15 Return Glass Anti-sweat Heaters 120V 50/60Hz Standard 0.06 0.08 0.11 7.3 9 13 230V 50/60Hz Export 0.03 0.04 0.06 7.3 9 13 208V Electric Defrost 230V Export Electric Defrost 120V Koolgas Defrost 208V Koolgas Defrost 230V Koolgas Defrost 6.54 7.69 11.54 1360 1600 2400 5.91 6.96 10.43 1360 1600 2400 1.33 1.67 3.33 160 200 400 0.77 0.96 1.92 160 200 400 0.85 1.06 2.12 196 244 488 Standard Lighting None 4 of 7 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 FG Technical Data Sheet

Excel FG Product Data Recommended Usable Cube 1 (Cu Ft/Ft) AHRI Total Display Area 2 (Sq Ft/Ft) Shelf Area 3 (Sq Ft/Ft) 3.69 ft 3 /ft (0.34 m 3 /m) 3.02 ft 2 /ft (0.92 m 2 /m) 2.79 ft 2 /ft (0.85 m 2 /m) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is NONE. ESTIMATED SHIPPING WEIGHT 4 Case Solid End 4 ft 6 ft 8 ft 12 ft (each) lb (kg) 600 (272) 800 (363) 1000 (454) 1200 (544) 50 (23) 4 Actual weights will vary according to optional kits included. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 7

Electric Defrost Standard 120V Neutral 120V Power Brown Band Brown Band Fans Nosing Anti-Sweat Heater Refrigeration Thermostat (Optional) Light Blue To Condensing Unit Defrost Termination Thermostat To Condensing Unit L1 208V Power From Defrost Contactors L2 Red 6 Drip Pan Heater 5 Red Electric Defrost Heaters WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Number = Parts List Item Numbers 6 of 7 U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 FG Technical Data Sheet

Gas Defrost Optional 120V Drip Pan Heater Koolgas Only 7 4 Heater Switch 208V/230V Drip Pan Heater Koolgas Only 7 7 4 Heater Switch 4 Heater Switch 120V Power 120V Neutral L1 L2 L1 L2 WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled Number = Parts List Item Numbers HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 7