Industries. As a premier global manufacturing company, we believe that great brands are

Similar documents
Eaton is a global leader with expertise in:

EFBW series - BiWire Ultra control panel

Cooper Industries (UK) Ltd

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Conventional systems Product Name

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

System 800 Addressable Fire Detection & Alarm System

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Installation, Operating and Maintenance Manual

Installation and user manual for the BiWire / Conventional Repeater Panel

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Emergi-Lite Orbis detectors

Fire Product Catalog

OPERATION AND INSTALLATION MANUAL

Conventional Fire Detection

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

Door Release Power Supply

Conventional Fire Alarm System 2014 V1.2

Xenex Conventional Fire Detection & Alarm System

FEC400 Series. Installation Manual

4 wire conventional alarm system

Control Panel Engineering and Commissioning Instructions

Intelligent Security & Fire Ltd

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Addressable and Conventional Fire Protection

Fire Signalling. Signalling Solutions

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

The complete conventional fire warning system

MINERVA MZX125 Digital Addressable Fire Detection System

Control Panel User Guide

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

CONTENTS NBM-06 Bell (6") Page 1

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

General Routing Interface

Analogue addressable devices

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

5000 INSTALLATION GUIDE

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Intelligent Security & Fire Ltd

Menvier Fire System MF9300

Conventional Leaflets

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Fire Signalling. Signalling Solutions

Excel-EN Conventional Fire Control Panel

Sita200plus. 200detectors. Single loop analogue addressable System

Conventional Smoke Detectors KFAPO

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Touch Screen 1 loop Addressable Fire Alarm Panel

An introduction to... Sigma

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

MINERVA MX. 800 Series Ancillary Equipment

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

Cooper Fire Systems. UL Listed Range

MINERVA MZX125. Digital Addressable Fire Detection System

Series 65 Product Guide MAN 3036

USER MANUAL & MAINTENANCE GUIDE OG OO

Installation, Commissioning & Operating Manual

Installation and Operating Instructions

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

Intelligent addressable fire alarm control panel

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Control Panel User Guide

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Application, Installation, Operation & Maintenance Manual

Specification/ Data Sheet

SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE

FEC403EN Installation Manual

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Consultant Specification AGILE Wireless Fire Detection System

SECURIT 700L PLUS ENGINEERING MANUAL

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

QA16 Addressable System

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Evolution Analogue Addressable Fire System

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

D-Tect 2 GJD300 Quad PIR Movement Detector

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Control Panel User Guide (TO BE RETAINED BY THE USER)

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Transcription:

JSB Fire Systems

ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier global manufacturing company, we believe that great brands are built on high quality and excellent service. Which is why our brands have earned leading positions in the markets we serve. Cooper Safety specialises in products designed to save lives and protect property in commercial, industrial and residential buildings. It s just one of the seven divisions that continue to uphold our reputation through unparalleled sales support and customer service. 2

Bi-Wire 7 Fire Panels 11 Repeater Panels 13 Multi-Mode Detector 15 Standard Base 17 Sounder Base 19 Beacon Base 21 Sounder Beacon Base 23 Callpoints 25 Wall Sounder 27 LED Beacon 29 Relay Modules Conventional 33 Fire Panels 41 Repeater Panels 43 Detectors 45 Standard Base 47 Relay Base 49 Remote Indicator 51 Callpoints 53 Bell 55 Flush Sounder 57 Surface Sounders 59 High Output Wall Sounder 61 Xenon Beacons 63 Xenon Sounder Beacons 65 Compact Door Retainers Ancillaries and Test Equipment 67 Power Supply Unit 3

About us Cooper Safety Fire Systems Cooper Fire offers a comprehensive range of JSB fire detection products suitable for most small standard installations and installations requiring BS5839 Pt1 & Pt6 compliance. Cooper Fire manufacture a wide range of products and offers complete fire solutions, not just individual components. A complete system can be specified from a single source, confident in the knowledge that all the components have been specifically designed and tested to ensure they are all fully compatible with each other and will function as a truly integrated fire detection and alarm system. It is absolutely vital that all the elements of a fire detection system are fully compatible with each other. To support this philosophy, a large multi-disciplined research and development team is based in the UK at the Cooper Doncaster facility, responsible for the integration of the very latest technology into the design of our comprehensive range of fire products. 4

Bi-Wire Product Range Bi-Wire Contents Page 7 Control Panels FX2200BW Range Page 23 Callpoints FX201 and FX203 Page 11 Repeater Panel FXRP2200BW Page 25 Wall Sounder FX009 Page 13 Multi-Mode Detector FXN922 Page 27 LED Beacon FXN004BW Page 15 Standard Base FXN520 Page 29 Relay Modules FXN01124V and FXN011230 Page 17 Sounder Base FXN521BWS Page 19 Beacon Base FXN521BWB Page 21 Sounder Beacon Base FXN521BWSB 5

Bi-Wire System Architecure The JSB Bi-Wire systems is based on standard conventional system technology, but it also incorporates additional functionality to enable the callpoints, detectors and sounders for each separate zone to be wired on a single common circuit. This enables the control panel to use a single circuit per zone for connection of detectors, sounders, LED beacons and relays. Even though the panel continually powers the sounders, control functionality incorporated within the sounders enables them to only be activated in the event of a fire alarm condition. By combining both the detection and the alarm annunciation wiring into a single circuit, considerable savings in installation time and cabling can be achieved. Although adding Bi-Wire technology to the detectors and the sounders does slightly increase the equipment costs this is more than offset by the substantial savings in installation and cabling cost. Zone 1 Zone 2 Zone 3 Zone 4 6

Bi-Wire Product Range FX2200BW Range Control Panels Patented Technology semi-recessing back box (for 4 and 8 zone panel) FX2204BWHMO 4 zone control panel simple user interface Overview The JSB range of Bi-Wire control panels are designed with Cooper patented 2 wire technology (Patent Number GB2293257) and also includes patented Self-Check detector features (Patent Number EP:02253889). Bi-Wire conventional detectors, sounders, LED beacons, and relay modules, all share the same zone wiring, delivering significant savings in both cable and installation costs. All panels in this range have the facility to flash detector LED s in a zone to facilitate the location of any wiring fault in that zone, thereby simplifying the fault finding process. The 4 and 8 zone panels provide enhanced features, which includes HMO programming per zone via the easily accessible DIP switch. If a zone is programmed for HMO and a fire occurs in that zone, only the sounders in that zone will sound, if the fire is cleared within 2 minutes, the panel will reset automatically, otherwise the sounders in all the zones will operate. Features 2, 4, and 8 zone panels Self-Check features Detectors, sounders and relay modules share same wiring Repeater output on 4 and 8 zone panel Class change facility Selectable fire/fault relay Supports up to 20 detectors and 20 sounders / ancillaries per zone Detector removal indication Maintenance-free poly switch Weekly test/walk test facility Benefits Minimise cabling requirements Reduced installation time Maximises installation savings 4 and 8 zone panels HMO compliant Simplified fault finding process Improved system integrity 7

MUTE BUZZER SCROLL Bi-Wire Control Panels - FX2200BW Range Technical Specification FX2202BW FX2204BWHMO FX2208BWHMO 2 zone Bi-Wire panel 4 zone Bi-Wire panel 8 zone Bi-Wire panel Standards EN54 Pt2 & Pt4 EN54 Pt2 & Pt4 EN54 Pt2 & Pt4 EN50130-4: 1996 EN500081-1: 1992, EN61000-2-2: 1994 EN50130-4: 1996 EN500081-1: 1992, EN61000-2-2: 1994 EN50130-4: 1996 EN500081-1: 1992, EN61000-2-2: 1994 Specification Number of Zones 2 4 8 Detectors per Zone 20 20 20 Sounders per Zone 20 20 20 Alarm Circuit Load per Zone 150mA 150mA 150mA End of Line Devices Active end of line monitoring unit Active end of line monitoring unit Active end of line monitoring unit Auxiliary Fire Signal/Fault Output 1A 24V dc single pole changeover contacts 1A 24V dc single pole changeover contacts 1A 24V dc single pole changeover contacts HMO Facility NO Yes (on all zones) Yes (on all zones) Mains Input Voltage 230V ac 10% +15% 230V ac 10% +15% 230V ac 10% +15% Operating Voltage 24V dc 24V dc 24V dc Standby Duration 24 hours 24 hours 24 hours Battery 1 x 2.1Ah (sealed lead acid) 1 x 3.2Ah (sealed lead acid) 2 x 3.2Ah (sealed lead acid) Recharge Period 24 hours 24 hours 24 hours Environmental Operating Temperature -5 C to +40 C -5 C to +40 C -5 C to +40 C Humidity (non condensing) 0 to 75% RH 0 to 75% RH 0 to 75% RH Physical Construction PC PC PC Dimensions 260mm x 212mm x 72mm 332mm x 270mm x 92mm 332mm x 270mm x 92mm Weight 5.2kg 5.8kg 6.0kg Ingress Protection IP30 IP30 IP30 Cable Entry Top: 6 x 20mm entries with blanking plugs, Top: 12 x 20mm entries with blanking plugs, Top: 12 x 20mm entries with blanking plugs, rear cable entry aperture rear cable entry aperture rear cable entry aperture Dimensions H D1 W 1 2 3 4 5 H (mm) W (mm) D1 (mm) D2 (mm) 2 zone 212 260 72-4 and 8 zone 270 332 45 47 Back Box (4 and 8 zone) 264 325 76 - Cut-out (mm) if back box used 4 and 8 zone H 265 x W 327 x D 47 D2 Note: If surface mounting add D1 and D2 to obtain depth dimension. Product s FX2202BW FX2204BWHMO FX2208BWHMO FX22003300MB Bi-Wire 2 zone control panel Bi-Wire 4 zone control panel, HMO Bi-Wire 8 zone control panel, HMO Semi-recessing back box (for 4 and 8 zone panel) 8

Bi-Wire Control Panels - FX2200BW Range Installation 1. A full set of Installation and user instructions is supplied with each panel to assist the installer to carry out the work efficiently and safely, and the user to perform routine tests. 2. Panels are designed for wall mounting and can be either surface or semi-flush mounted, via 4 x screw fixing holes on back of housing using the drill template supplied. Recessed mounting requires an appropriate cut-out for the steel semi-recessing box (optional extra), which is screw fixed in to the wall recess. Panel is then screwed to back box via 4 x screw fixing holes (Note: Single zone panel cannot be recessed). 3. Mains power supply cable must be routed via the designated 20mm conduit entry on the top or aperture on rear of the housing. The mains terminal block is provided with maintenance free poly switch protection. 4. 12 conduit entries are provided on the top of the housing for zone, alarm and output cables. Blanking plugs are supplied for un-used entry holes. 5. Standby batteries connected via push-on terminal connectors. 6. End of line (EOL) devices are supplied with the panel and must be fitted at the end of each zone 7. Front cover is screw fixed. System log book is stored behind hinged door. 8. Walk test feature permits single person commissioning (installer) for fast and efficient commissioning prior to handover. User Interface 1. Stylish and robust compact panel with simple 5 button keypad control of all functions. 2. Simple "one-shot" weekly user test with auto-reset facility. 3. Comprehensive power, fire and fault LED indicators and integral piezo buzzer for on-board fire or fault indication. 4. Battery high/low voltage alarm facility. 5. Neat log book storage facility behind hinged door. Interface Options 1. Class change input facility. Terminals provided to activate alarms without triggering a fire condition, typically used to indicate school/college class change. 2. Programmable volt free contact relay capable of switching 24V dc 1A for remote signalling of fire or fault conditions. Selectable by jumper link. System Functionality 1. Normal and supervisor mode facility. Supervisor mode protected by 4 digit security code to prevent unauthorised use. 2. Supervisor mode provides access to test mode, where a "one-shot" test facility can be initiated by the user. When in operation, the user has a short period of time in which to put a call point into fire condition, after which the system automatically resets and returns to normal mode. 3. Commissioning walk test feature permits the system to be easily tested after installation and prior to handover. The panel automatically resets and returns to normal operation after a detection device has been tested. Each device can then be tested in turn via the same procedure. 4. Supervisor mode also provides facility to disable the following for maintenance or other purposes: Each detection zone independently The outputs (sounders/beacons) 9

Bi-Wire Control Panels - FX2200BW Range Standard Panel Connections - FX2202BW VOLT FREE CLASS CHANGE CONTACT TO OPERATE SOUNDER CIRCUITS CLOSE TO OPERATE SOUNDERS AUXILLARY RELAY 1 2 3 DETECTORS, CALLPOINTS AND SOUNDERS (REFER TO INDIVIDUAL WIRING DIAGRAMS) TO ZONE 2 1 2 3 EOLM-1 TX1 L N E CLASS NO C NC - + - + CHANGE AUXILLARY 1 2 CIRCUIT COMBINED ZONAL/SOUNDER CIRCUITS Standard Panel Connections - FX2204BWHMO and FX2208BWHMO 1 2 3 1 2 3 EOLM-1 DETECTORS, CALLPOINTS AND SOUNDERS (REFER TO INDIVIDUAL WIRING DIAGRAMS) 1 2 3 1 2 3 EOLM-1 FIRE RELAY FAULT RELAY VOLT FREE CLASS CHANGE CONTACT TO OPERATE SOUNDER CIRCUITS AS PER ZONES 1 & 2 (ONLY ON 8 ZONE PANEL) AS PER ZONES 1 & 2 L N E F3 C NO NC AUXILLARY CIRCUIT C NO NC AUXILLARY CIRCUIT +12V +0V TX+ TX- CLASS - + - + - + - + - + - + - + - + 12V dc CHANGE 1 2 3 4 5 6 7 8 SUPPLY F1 ZONE CARD NOTE: 1. If a base sounder is used as a dedicated sounder(no detector fitted) connect the EOLM or negative out to terminal 2, instead of terminal 3 10

Bi-Wire Product Range Repeater Panel FXRP2200BW FXRP2200BW repeater panel Overview To complement the JSB FX2200BW range a repeater panel is available for connection to the 4 and 8 zone panels. This repeater has been specifically designed for ease of installation requiring only 2 interconnecting wires from the main panel this compared with up to 16 wires on many conventional panels represents a large cost saving both on material and labour. Further repeater panels can be cascaded. again only using 2 wires. With stand by time not effected by the number of repeaters connected to each panel as each repeater has its own main supply and standby battery. The repeater is suitable for up to 8 zones and displays all the same functions as the main panel, but with the addition of a indicator test facility. Features Facility for signalling to repeater panel provided as standard on 4 and 8 zone panel Charger with built in temperature compensation Displays essential information at other key locations in a large building/site Zone fire and fault conditions Test mode in operation Zones or alarm lines in disabled mode Benefits Repeater matches the style and appearance of the main control panel Repeater panel requires only a single pair of wires to receive signals from main control panel, plus local mains power supply, reducing cost of installation Cost saving 11

MUTE SCROLL BUZZER Bi-Wire Repeater Panel - FXRP2200BW Dimensions H D2 D1 W 1 2 3 4 5 H (mm) W (mm) D1 (mm) D2 (mm) 260 212 45 77 Technical Specification FXRP2200BW Bi-Wire repeater panel Specification Distance 2km Mains Input Voltage 230V ac -15%, +10% Standby Duration 24 hours Battery 1 x 1.2Ah (sealed lead acid) Recharge Period 24 hours Environmental Operating Temperature -5 C to +40 C Humidity (Non Condensing) 0 to 75% RH Physical Construction PC Dimensions (H x W x D) 260mm x 212mm x 122mm Weight 3.6kg Ingress Protection IP30 Compatibility Suitable for use with JSB Bi-Wire fire systems Installation 1. Wall mounted by means of 4 fixing screws. 2. Cable entry at back. 3. 12 top entry gland holes with push out blanking plugs. 4. 4 separate rear access cable entry facilities. 5. Local mains supply required and must be routed via the designated 20mm conduit entry in the top or the rear of the housing. Device Overview 1. Supplied with integral power supply and standby battery. System Functionality 1. Supplied with integrated power supply and stand by battery. 2. Provides local indication of essential information e.g fire, fault and disablement. 3. Suitable for use with Bi-Wire 4 and 8 zone control panels. Standard Connection MAX CABLE LENGTH 2km TO ADDITIONAL REPEATERS (IF REQUIRED) RECOMMENDED CABLE SIZE 1.00mm² L N E + - REPEATER OUTPUT CONNECTIONS L N E + - LINE INPUT CONNECTIONS + - LINE OUTPUT CONNECTIONS BI-WIRE CONTROL PANEL (4 OR 8 ZONE) BI-WIRE REPEATER PANEL Product s FXRP2200BW FX22003300MB Bi-Wire repeater panel Semi-recessing back box 12

Bi-Wire Product Range Multi-Mode Detector FXN922 red LED, fire condition amber LED, smoke sensing fault FXN922 multi-mode detector flashing amber LED, wiring fault Overview The JSB Bi-Wire multi-mode detector has a dual patent, and incorporates both Bi-Wire and Self-Check features, as well as having 5 different modes within a single detector. This multi-mode detector can be configured to operate as either an optical detector, opto/heat multi-sensor or 1 of 3 heat detector modes (A1R, BS, CS) using the four position switch located at the back of the detector. The detector, having Self-Check facilities, has a dual LED indicator. The red LED is lit continuously to indicate alarm condition, the amber LED when lit continuously indicates a smoke sensing chamber fault or that the detector has reached the limit of its contamination compensating ability. The amber LED can also be pulsed from the panel to locate wiring faults thereby saving time and cost by facilitating the fault finding process. Features Chamber monitoring and drift compensation dual LED Self-Check facility 360 viewable LED design Benefits 5 modes in 1 detector Unobtrusive design Common mounting base Improved system integrity 13

Bi-Wire Multi-Mode Detector - FXN922 Dimensions D Dia Dia (mm) D (mm) D (mm) (excl base) (incl base) Detractor 104 42 55 Technical Specification FXN922 Bi-Wire multi-mode detector Standards EN54 Pt5 & Pt7 2000: A1 2002 Specification Operating Voltage 15V dc to 30V dc Standby Current 70µA Startup Current (for 20s max) 340µA Alarm Current 25mA (max) Heat Detector Class (as define by EN54-5:2000) A1R, BS, CS programmable Alarm Temperature (static) 60 C A1R, 77 C BS, 92 C CS Visual Indication Red (alarm) Amber (fault) Environmental Operating Temperature -10 C +50 C Humidity (Non Condensing) 0 to 93% RH Physical Construction PC/ABS Colour White Dimensions Excluding Base (H x Dia) 42mm x 104mm Including Base (H x Dia) 55mm x 104mm Weight (excluding base) 78g Ingress Protection IP40 Compatibility Suitable for use with JSB Bi-Wire fire systems Switch Settings Installation User Interface On On 1. Detectors are fixed and wired via common mounting base. 2. Cable entry into base can be rear or side. 3. A locking facility is provided which can be activated if required to prevent unauthorised detector removal without the use of a special tool. 4. Positive click mechanism incorporated to provide clear indication when detector is correctly located in base. 1. Red LED to indicate alarm condition. 2. Amber LED to indicate chamber fault/drift compensation limit 3. All wiring connections are via a common mounting base (supplied separately). 1 2 3 4 Off Note: For wiring information please see FXN520 base SW1 SW2 SW3 SW4 Opto - OFF OFF OFF Opto / Heat - OFF OFF ON Rate of rise - ON OFF OFF Fixed heat BS - ON OFF ON Fixed heat CS - ON ON OFF HMO ON - - - Latching alarm OFF - - - Product s FXN922 Bi-Wire multi-mode detector 14

Bi-Wire Product Range Standard Base FXN520 multi-mode detector for use with the FXN520 standard base FXN922 multi-mode detector FXN520 standard base Overview The JSB Bi-Wire standard base has been specifically designed to be compatible with the JSB Bi-Wire multi-mode detector FXN922. This standard base has been designed for flexibility, simplicity and speed of installation. It incorporates purpose designed devices to provide fault warning if detector is removed whilst maintaining full zone wiring integrity. Features Separate zone in and zone out terminals Stand off fixing feature Selectable detector locking Benefits Quick and simple to install Accepts side entry surface cables The base has a schotty diode in series with the negative terminals to enable fault monitoring and allow the circuit to continue functioning if a detector is removed. 15

Bi-Wire Standard Base - FXN520 Dimensions Technical Specification D Dia (mm) D (mm) 104 22 Physical Construction FXN520 Bi-Wire standard base PC/ABS Colour White Dimensions (Dia x D) 104mm x 22mm Compatibility Suitable for use with JSB Bi-Wire detectors Dia Installation Interface Options 1. Base incorporates a retaining clip to provide positive feedback when detector is correctly fitted. 2. Separate terminals are provided for zone in and zone out connections. 3. Each terminal can accept up to 2 x 2.5mm cables 4. Base incorporates a substantial cable entry aperture in the rear of the base. 5. Breakouts are provided to enable the detector base to sit neatly over surface cables and then enter via the rear entry aperture. 6. Base mounting incorporates a stand off feature to help prevent distortion when mounted on an uneven surface. 7. Fixings are suitable for standard BESA box or direct fixing to suitable surface 8. Optional locking devices (supplied with base) to prevent unauthorised detector removal. 1. JSB Bi-Wire detectors and bases support the use of a remote LED (optional extra FX251D). Standard Connection + VE + remote indicator (optional) Compatible JSB Bi-Wire Control Panelsl -ZONE + 2 1 LED 3 E 4 2 1 LED 3 E 4 EOLM-1 end of line monitor device - VE Product s FXN520 FX251D Bi-Wire standard base Conventional remote indicator 16

Bi-Wire Product Range Sounder Base FXN521BWS multi-mode detector for use with the FXN521BWS sounder base FXN922 multi-mode detector FXN521BWS sounder base Overview The JSB Bi-Wire sounder base has been developed specifically to operate with JSB Bi-Wire control panels and to compliment the multi-mode Bi-Wire detector. The sounder base incorporates a detector mounting base, a detector can be fitted directly to the base, or alternatively an optional cover plate can be used to provide a dedicated discreet stand alone device. Features Can be used with a detector or as a stand alone unit Integral mounting base Integral sounder base Uses patented technology Optional cover plate available Benefits Single point connection reduces wiring requirement and installation time Aesthetically pleasing detector and sounder combination 17

Bi-Wire Sounder Base - FXN521BWS Dimensions Technical Specification Dia Dia (mm) D (mm) 102 40 Standards FXN521BWS Bi-Wire sounder base EN54 Pt3 Specification D Operating Voltage Current Consumption 18V dc to 32V dc 7mA at 24V dc Sound Output @+/- 3dB 90dB(A) at 7mA Tones Continuos 910Hz Environmental Operating Temperature -10 to +55 C Humidity (Non Condensing) 0 to 95 %RH Physical Construction ABS Colour White Dimensions (Dia x D) 102mm x 40mm Weight 0.2 kg Ingress Protection IP40 Compatibility Suitable for use with JSB Bi-Wire fire systems Installation 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface via 2 fixings holes. 3. Cables enter through aperture in base (rear entry only). 4. Main body is then clipped into place on base, main body locks into place when pressed into position. 5. Connections are on front of main sounder body. 6. Detector or cover plate is then fixed to sounder. 7. Detector or cover plate can be locked in place if required. Device Functionality 1. Bi-Wire technology allows conventional detectors, callpoints and sounders to be connected on the same pair of wires. 2. The sounder base further reduces installation time, cost and effort by enabling a detector and sounder to be fixed and wired at a single common point. 3. The sounder base is only suitable for use with the JSB range of Bi-Wire control panels. Standard Connection (when fitted with a detector) + VE + remote indicator (optional) Compatible JSB Bi-Wire Control Panelsl -ZONE + 2 1 LED 3 E 4 2 1 LED 3 E 4 EOLM-1 end of line monitor device - VE NOTE: If sounder, sounder beacon or beacon base is used without the JSB Bi-Wire detector connect both in and out -VE to terminal 2. Product s FXN521BWS Bi-Wire sounder base FXN538COV Sounder cover plates (pack of 5) 18

Bi-Wire Product Range Beacon Base FXN521BWB multi-mode detector for use with the FXN521BWB beacon base FXN922 multi-mode detector FXN521BWB beacon base Overview The JSB Bi-Wire beacon base has been developed specifically to operate with JSB Bi-Wire control panels and to compliment the multi-mode Bi-Wire detector. The beacon base incorporates a detector mounting base, a detector can be fitted directly to the base, or alternatively an optional cover plate can be used to provide a dedicated discreet stand alone device. Features Can be used with a detector or as a stand alone unit Integral mounting base Integral high output LED beacon Uses patented technology Optional cover plate available Benefits Single point connection reduces wiring requirement and installation time Aesthetically pleasing detector and beacon combination 19

Bi-Wire Beacon Base - FXN521BWB Dimensions Technical Specification Dia Dia (mm) D (mm) 102 40 Specification FXN521BWB Bi-Wire beacon base Operating Voltage 18V dc to 32V dc D Current Consumption Flash Frequency 7mA at 24V dc 1Hz Environmental Operating Temperature -10 to +55 C Humidity (Non Condensing) 0 to 95 %RH Physical Construction ABS Colour White Dimensions (Dia x D) 102mm x 40mm Weight 0.2 kg Ingress Protection IP40 Compatibility Suitable for use with JSB Bi-Wire fire systems Installation 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface via 2 fixings holes. 3. Cables enter through aperture in base (rear entry only). 4. Main body is then clipped into place on base, main body locks into place when pressed into position. 5. Connections are on front of main beacon body. 6. Detector or cover plate is then fixed to beacon. 7. Detector or cover plate can be locked in place if required. Device Functionality 1. Bi-Wire technology allows conventional detectors, callpoints and beacons to be connected on the same pair of wires. 2. The beacon base further reduces installation time, cost and effort by enabling a detector and beacon to be fixed and wired at a single common point. 3. The beacon base is only suitable for use with the JSB range of Bi-Wire control panels. Standard Connection (when fitted with a detector) + VE + remote indicator (optional) Compatible JSB Bi-Wire Control Panelsl -ZONE + 2 1 LED 3 E 4 2 1 LED 3 E 4 EOLM-1 end of line monitor device - VE NOTE: If sounder, sounder beacon or beacon base is used without the JSB Bi-Wire detector connect both in and out -VE to terminal 2. Product s FXN521BWB Bi-Wire beacon base FXN538COV Sounder cover plates (pack of 5) 20

B-Wire Product Range Sounder Beacon Base FXN521BWSB multi-mode detector for use with the FXN521BWSB sounder beacon base FXN922 multi-mode detector FXN521BWSB sounder beacon base Overview The JSB Bi-Wire sounder beacon base has been developed specifically to operate with JSB Bi-Wire control panels and to complement the multi-mode Bi-Wire detector. The sounder beacon base incorporates a detector mounting base, a detector can be fitted directly to the base, or alternatively an optional cover plate can be used to provide a dedicated discreet stand alone device. This sounder beacon base includes all the features of the Bi-Wire sounder base as well as a powerful LED beacon. Features Can be used with a detector or as a stand alone unit Integral mounting base Integral sounder base Integral high output LED beacon Uses patented technology Optional cover plate available Benefits Single point connection reduces wiring requirement and installation time Aesthetically pleasing detector, sounder and beacon combination 21

Bi-Wire Sounder Beacon Base - FXN521BWSB Dimensions Technical Specification Dia Dia (mm) D (mm) 102 40 Standards FXN521BWSB Bi-Wire sounder beacon base EN54 Pt3 Specification D Operating Voltage Current Consumption 18V dc to 32V dc 7mA Sound Output @+/- 3dB 90dB(A) at 7mA Tones Continuos 910Hz Flash Frequency 1Hz Environmental Operating Temperature -10 to +55 C Humidity (Non Condensing) 0 to 95 %RH Physical Construction ABS Colour White Dimensions (Dia x D) 102mm x 40mm Weight 0.2 kg Ingress Protection IP40 Compatibility Suitable for use with JSB Bi-Wire fire systems Installation 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface via 2 fixings holes. 3. Cables enter through aperture in base (rear entry only). 4. Main body is then clipped into place on base, main body locks into place when pressed into position. 5. Connections are on front of main sounder beacon body. 6. Detector or cover plate is then fixed to sounder beacon. 7. Detector or cover plate can be locked in place if required. Device Functionality 1. Bi-Wire technology allows conventional detectors, callpoints, sounders and beacons to be connected on the same pair of wires. 2. The sounder beacon base further reduces installation time, cost and effort by enabling a detector and sounder to be fixed and wired at a single common point. 3. The sounder beacon base is only suitable for use with the JSB range of Bi-Wire control panels. Standard Connection (when fitted with a detector) + VE + remote indicator (optional) Compatible JSB Bi-Wire Control Panelsl -ZONE + 2 1 LED 3 E 4 2 1 LED 3 E 4 EOLM-1 end of line monitor device - VE NOTE: If sounder, sounder beacon or beacon base is used without the JSB Bi-Wire detector connect both in and out -VE to terminal 2. Product s FXN521BWSB Bi-Wire sounder beacon base FXN538COV Sounder cover plates (pack of 5) 22

Bi-Wire Product Range Callpoints FX201 and FX203 FX201 callpoint Overview This attractively designed, simple to install, range of callpoints have been specifically developed to be compatible with JSB Bi-Wire control panels. There are 2 versions of callpoint in this range. The FX201 which can be either surface or flush mounted and the FX203 which is a weatherproof version and can only be surface mounted. All callpoints are supplied as standard with a frangible glass element and a test key for ease of maintenance. Features High visibility status LED Standard and weatherproof versions available Heavy duty terminals Benefits Quick and simple to install Fast fit clip on front cover Single tool for test and access 23

Bi-Wire Callpoints - FX201 and FX203 Dimensions H D H (mm) W (mm) D (mm) Flush mounted 87 87 36 Surface mounted 87 87 57 Weatherproof 87 87 59 W Technical Specification FX201 FX203 Bi-Wire surface/flush mount callpoint Bi-Wire weatherproof callpoint Standards EN54 Pt11 EN54 Pt11 Specification Operating Voltage 18V dc to 30V dc 18V dc to 30V dc Environmental Operating Temperature -10 C to +55 C -25 C to +70 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS Colour Red Red Dimensions (H x W x D) 87mm x 87mm x 57mm (36mm flush) 87mm x 87mm x 59mm Weight 0.2kg 0.2kg Ingress Protection IP24D IP65 Compatibility Suitable for use with JSB Bi-Wire fire systems JSB Bi-Wire fire systems Standard Connection FX201 / FX203 Compatible JSB Bi-Wire Control Panel COMMON 680Ω + + - - WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable Installation 1. Surface callpoint has standard rear BESA fixing facilities. In addition, back box can accept top or bottom surface entry cables. Surface callpoint can also be flush mounted. 2. Callpoint has test facility via special test key to prevent unauthorised operation. 3. Insertion of test key for test purposes and for cover removal is at bottom of callpoint to facilitate ease of access when mounted next to door architrave. 4. Test key is dual function, used to test callpoint operation by simulating activation and also to allow removal of clip on cover to gain access to element. 5. Element is held in place by clip on self locking cover which can only be removed by use of a special tool (callpoint test key). 6. Separate zone in and zone out terminals are provided for all connections. 7. Surface/flush callpoints are IP24D, weatherproof is IP65. User Interface 1. To enable quick and simple installation, callpoints use a fast fit self locking clip on front cover which is very simple to fit, but once in place, can only be removed by use of a special key (supplied). 2. Callpoint is triggered by pressing against the element. Product s FX201 Bi-Wire surface/flush callpoint FX203 Bi-Wire weatherproof callpoint FX5G Spare break glasses (pack of 5) 24

Bi-Wire Product Range Wall Sounder FX009 FX009 wall sounder Overview The JSB Bi-Wire FX009 is a high output wall mounted sounder which is designed to operate with the JSB Bi-Wire fire system. It has a very low current consumption enabling numerous sounders to be connected to each JSB Bi-Wire panel zone. Features High output Low current consumption Volume control Surface or rear cable entry Separate input and output terminals for ease of installation Uses patented technology Benefits Single point connection reduces wiring requirement and installation time Aesthetically pleasing design 25

Bi-Wire Wall Sounder - FX009 Dimensions Technical Specification D H (mm) W (mm) D (mm) 105 105 95 Standards FX009 Bi-Wire wall sounder EN54 Pt3 Specification H Operating Voltage Current Consumption 18V dc to 30V dc 5mA at 24V dc Sound Output 96dB(A) at 24V dc Environmental W Operating Temperature -25 C to +70 C Humidity (Non Condensing) 0 to 95% RH Physical Construction ABS Colour Red Dimensions (Dia x D) 105mm x 105mm x 95mm Weight 0.24kg Ingress Protection IP42 Compatibility Suitable for use with JSB Bi-Wire fire systems Standard Connection FX009 Compatible JSB Bi-Wire Control Panel + + - - WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable Installation 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface using 2 fixing holes. 3. Cable entry can be rear or side. 4. Connections are to connector block on main sounder body. 5. Main body is then clipped into position on mounting base, body locks into position when pressed home. Device Functionality 1. Connected on the same pair of wires as the detectors and callpoints. 2. Volume is adjustable. 3. Same tone as JSB base mounted Bi-Wire sounder enabling both types to be used on the same site. Product s FX009 Bi-Wire wall sounder 26

Bi-Wire Product Range LED Beacon FXN004BW FXN004BW LED beacon Overview The JSB Bi-Wire LED beacon is available to complement audible alarms for use in areas where people may be present who have impaired hearing or areas with high ambient noise levels. LED technology offers a greatly reduced current consumption compared to Xenon types making them ideal for use with fire panels with restricted sounder circuit current capacity. Features Unobtrusive low profile design Low power consumption LED s Choice of flash frequency Choice of power settings Pre-drilled cable entries Benefits Single point connection reduces wiring requirement and installation time Aesthetically pleasing design 27

Bi-Wire LED Beacon - FXN004BW Dimensions Technical Specification D Dia Dia (mm) D (mm) 105 53 Specification Operating Voltage Current Consumption Flash Frequency Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Lens Colour Dimensions (Dia x D) Weight Ingress Protection Compatibility Suitable for use with FX009 Bi-Wire LED beacon 18V dc to 30V dc 6mA at 24V dc 1Hz -10 C to +55 C 0 to 93% RH PC/ABS Red Red 95mm x 53mm 0.1kg IP42 JSB Bi-Wire fire systems Standard Connection FXN004BW Compatible JSB Bi-Wire Control Panel + + - - WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable Installation 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main beacon body. 5. Separate alarm line in / out terminals are provided. 6. Main body is pushed into base and then twisted to lock into place. Interface Options 1. Operates from nominal 24V dc supply and can be connected to any suitably rated Bi-Wire sounder circuit. Product s FXN004BW Bi-Wire LED beacon 28

Bi-Wire Product Range Relay Modules FXN01124V and FXN011230 relay module Overview The JSB Bi-Wire output relay module is designed to provide a simple means of interfacing Bi-Wire systems with external equipment such as door holders. It is simple to install and can switch up to 1A at 230V ac or 24V dc. The major advantage of using an output module is that external switching can easily be achieved without having to wire back to the main control panel. Features Quick and simple to install Connected to zone wiring Relay activates if any zone is triggered Allows simple interfacing with external equipment Benefits The 2 models provide for low or mains voltage switching Compact design Provides simple and convenient external switching 29

Bi-Wire Relay Module - FXN01124V and FXN011230 Dimensions Technical Specification H H (mm) W (mm) D (mm) 150 89 58 FXN01124V FXN011230 Bi-Wire output relay module (24V contacts) Bi-Wire output relay module (230V contacts) Standards EN54 Pt18 EN54 Pt18 Specification Contact Rating 1A 3A Sets of contacts 1 1 Contact Arrangement Change over Change over D W Physical Construction ABS ABS Dimensions (H x W x D) 150mm x 89mm x 58mm 150mm x 89mm x 58mm Weight 0.2kg 0.2kg Ingress Protection IP40 IP40 Compatibility Suitable for use with JSB Bi-Wire fire systems JSB Bi-Wire fire systems Standard Connection Installation Interface Options FXN01124V / FXN011230 Compatible JSB Bi-Wire Control Panel ZONE IN Screen E Earth - + E - + C IN Screen NC NO OUT ZONE OUT 1. Fixes to standard deep double gang back box. 2. Heavy duty terminals provided. 3. Cable entry is via back box. 4. Cables are terminated into terminals on PCB. System Functionality 1. Relay mimics that of a Bi-Wire sounder, whenever the sounders operate, the relay changes over. 1. The Bi-Wire relay module is specifically designed to be connected to a zone circuit of a JSB Bi-Wire system, it is not compatible with any other equipment or application. Relay Connections WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable. Product s FXN01124V FXN011230 Bi-Wire output relay module (24V contacts) Bi-Wire output relay module (230V contacts) 30

Conventional Product Range Conventional Contents Page 33 Control Panels FX2200 Range Page 57 Surface Sounders FX002 and FX002W Page 37 Control Panels FX4200 Range Page 59 High Output Wall Sounder FX007 Page 41 Repeater Panel FXRP2200 Page 61 Xenon Beacons FX004R and FX004B Page 43 Detectors FXN533, FXN632, FXN525 FXN524 and FXN526 Page 63 Xenon Sounder Beacons FX002CR, FX002CA and FX002CB Page 45 Standard Base FXN520 Page 65 Compact Door Retainer FX021240LC and FX02124VLC Page 47 Relay Base FXN520R Page 49 Remote Indicator FX251D Page 51 Callpoints FX201 and FX203 Page 53 Bell FX006 Page 55 Flush Sounders FX003 and FX003W 31

Conventional System Architecture The philosophy of a conventional system revolves around dividing the building into a number of areas called zones. The detectors and callpoints within each zone are then wired on dedicated circuits. In the event of a detector or callpoint being triggered, the panel is able to identify which circuit contains the triggered device and thereby indicate which zone the fire alarm has come from. It is then necessary to manually search the indicated zone to pinpoint the exact cause of the fire alarm. Unwanted Alarms Because most conventional detectors are simple two state devices they can only be in either a normal or fire condition. Although modern components and good system design can go some way to reducing potential problems, it is not uncommon for conventional systems to generate unwanted alarms due to certain operating conditions or transient environmental conditions such as the presence of steam near to a smoke detector. A key development aimed at reducing such unwanted alarms has been the multi-criteria detector. Traditionally, detectors were designed to respond to particular fire phenomena such as heat or the presence of smoke. However, Cooper now offer multi-criteria devices, which contain both a smoke sensing element and a thermal sensing element. The fire alarm decision is taken by analysis of the responses from both elements, resulting in improved detection performance as well as greatly enhanced false alarm suppression. This increases installation complexity by forcing the sounder wiring to follow different routes to that of the detector wiring. When designing a conventional system it is important to ensure that the panel has adequate zone capacity for the size and complexity of the building and that the panel can support the intended sounder circuit wiring and loading. Zone 1 Zone 2 Sounder Circuits In addition to the detection circuits, there is also a need for separate circuits of alarm annunciation devices such as sounders and beacons to signal the existence of a fire alarm condition to the building users. For sounder circuit continuity monitoring to function effectively, sounder circuits have to be wired in a single radial circuit, spurs and tees are not permitted. Almost every conventional fire panel will have facilities for more than one sounder circuit and generally the higher the specification of the panel or the higher the number of detection zones provided, the more sounder circuits will be provided. Normally however there will be less sounder circuits than detection zone circuits so it will be necessary for a sounder circuit to provide cover for more than one zone. Zone 3 Zone 4 32

Conventional Product Range FX2200 Range Control Panels log book conveniently stored within panel FX2202 control panel optional recessing back box Overview The JSB FX2200 range of conventional control panels provide a solution to any conventional system requirement. The advanced features include a simple one-shot user test facility, class change contacts, battery voltage alarms and charger temperature compensation, all included as standard to ensure ease of use and high reliability. Attention to detail is emphasised by the neat log book holder feature, allowing essential records to be stored close to hand, ready for quick reference. For larger installations, custom configuration of the panels offers even greater flexibility, allowing project specific requirements to be easily met, in a competitive and cost effective package. Features 1, 2, 4 or 8 zones panels Flexible, high specification system Simple one-shot auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard Custom configured versions available to meet specific project requirements Third party approved Benefits Compact design Surface or semi-flush mounting Numerical access code (no lost keys) 33

MUTE BUZZER SCROLL Conventional Control Panel - FX2200 Range Technical Specification FX2201 FX2202 FX2204 FX2208 1 zone control panel 2 zone control panel 4 zone control panel 8 zone control panel Standards EN54 Pt2 & Pt4 1998, EN54 Pt2 & Pt4 1998, EN54 Pt2 & Pt4 1998, EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130 Pt4 EN50130 Pt4 1996, EN50130 Pt4 EN50130 Pt4 1996, EN50130 Pt4 EN50130 Pt4 1996, EN50130 Pt4 Specification Number of Zones 1 2 4 8 Detectors per Zone 32 32 32 32 Number of Alarm Circuits 2 2 (4 on FX22002CR) 2 (4 on FX22004CR) 4 Alarm Circuit Load 150mA per circuit, 0.3A total 150mA per circuit, 0.3A total 400mA per circuit, 0.8A total 500mA per circuit, 2A total End Of Line Devices Detection circuits: EOLM-1 monitoring unit Detection circuits: EOLM-1 monitoring unit Detection circuits: EOLM-1 monitoring unit Detection circuits: EOLM-1 monitoring unit Alarm lines: 6.8KΩ resistor Alarm lines: 6.8KΩ resistor Alarm lines: 6.8KΩ resistor Alarm lines: 6.8KΩ resistor Auxiliary Fire Signal/Fault Output 5A 24V dc single pole changeover contacts 5A 24V dc single pole changeover contacts 5A 24V dc single pole changeover contacts 5A 24V dc single pole changeover contacts Auxiliary DC Output No No* No* 24V dc fused. 30mA Repeater Port No No* No* Yes Mains Input Voltage 230V ac -15% +10% 230V ac -15% +10% 230V ac -15% +10% 230V ac -15% +10% System Operating Voltage 24V dc 24V dc 24V dc 24V dc Standby Duration 24 hours 24 hours 24 hours 24 hours Battery (Sealed Lead Acid) 1 x 2.1Ah 1 x 3.2Ah 1 x 3.2Ah 2 x 3.2Ah Recharge Period 24 hours 24 hours 24 hours 24 hours Environmental Operating Temperature -5 C to +40 C -5 C to +40 C -5 C to +40 C -5 C to +40 C Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH 0 to 75% RH 0 to 75% RH Physical Construction Polycarbonate housing & back box Polycarbonate housing & back box Polycarbonate housing & back box Polycarbonate housing & back box Dimensions (H x W x D) Surface: 212mm x 260mm x 72mm Surface: 270mm x 332mm x 90mm Surface: 270mm x 332mm x 90mm Surface: 270mm x 332mm x 90mm Recessed: 279mm x 332mm x 122mm Recessed: 279mm x 332mm x 122mm Recessed: 279mm x 332mm x 122mm Weight 5.1kg 5.2kg 5.8kg 6.0kg Ingress Protection IP30 IP30 IP30 IP30 Cable Entry Top: 6x20mm entries with blanking plugs Top: 12x20mm entries with blanking plugs Top: 12x20mm entries with blanking plugs Top: 12x20mm entries with blanking plugs Rear cable entry aperture Rear cable entry aperture Rear cable entry aperture Rear cable entry aperture * Available on the FX2202CR and FX2204CR Dimensions D1 W H (mm) W (mm) D1 (mm) D2 (mm) 1 zone 212 260 72-2 / 4 / 8 zone 270 332 45 47 H 1 2 3 4 5 Cut-out (mm) 2 / 4 / 8 zone 265 x327 D2 Note: If surface mounting add D1 and D2 to obtain depth dimension. Product s FX2201 FX2202 FX2204 FX2208 FX2202CR FX2204CR FXRP2200 FX22003300 MB MFALOG Conventional 1 zone panel Conventional 2 zone panel Conventional 4 zone panel Conventional 8 zone panel Conventional 2 zone panel (configured for use with a repeater) Conventional 4 zone panel (configured for use with a repeater) Conventional repeater panel Steel back box (for use with FX2202/4/8) Fire alarm system log book 34

Conventional Control Panel - FX2200 Range Installation Notes 1. A full set of Installation and User Instructions is supplied with each panel to assist the installer to carry out the work efficiently and safely and the user to perform routine tests. 2. Panels are wall mounted. Surface mounted via 4 x screw fixing holes on back of housing. Use drill template supplied. Recessed mounting requires appropriate cut-out for steel semi-recessing box, which is screw fixed to wall. Panel is then screwed to back box via 4 x screw fixing holes (Note: Single zone panel cannot be recessed). 3. Mains power supply cable must be routed via the designated 20mm conduit entry on the top or rear of the housing. The mains terminal block is provided with maintenance free poly switch protection. 4. Conduit entries are provided on the top of the housing for zone, alarm and output cables. Blanking plugs are supplied for un-used entry holes 5. Rear entry apertures are also provided for back entry. 6. Standby batteries connected via push-on terminal connectors. 7. End of line (EOL) devices are supplied with the panel and must be fitted at the end of each detector and alarm circuit wiring. 8. Front cover is screw fixed. System logbook is stored behind hinged door. 9. Walk test feature permits single person testing for fast and efficient commissioning prior to handover. System Functionality 1. Normal and supervisor mode facility. Supervisor mode protected by 4 digit security code to prevent unauthorised use. 2. Supervisor mode provides access to test mode, where a one-shot test facility can be initiated by the user. When in operation, the user has a period of time in which to put a call point into fire condition, after which the system automatically resets and returns to normal mode. 3. Commissioning walk test feature permits the system to be easily tested after installation and prior to handover. The panel automatically resets and returns to normal operation after a detection device has been tested. Each device can then be tested in turn via the same procedure. 4. Supervisor mode also provides facility to disable the following for maintenance or other purposes each detection zone independently the alarm circuits 5. Non-latching zone facility can be specified on custom configured versions (except 1 zone panel). Enables the direct interconnection of panels in a simple network. 6. An alarm line delay feature can be specified on custom configured versions (except single zone panel). Preset delays of 30 seconds to 2 minutes can be programmed at the factory. Zone LED flashes when fire signal is received and delay is in operation. User Interface 1. Stylish and robust compact panel with simple 5 button keypad control of all functions. 2. Simple one-shot weekly user test with auto-reset facility. 3. Comprehensive power, fire and fault LED indicators and integral piezo buzzer for on-board fire or fault indication. 4. Battery high/low voltage alarm facility. 5. Neat log book storage facility behind hinged door. Interface Options 1. Class change input facility. Terminals provided for switching of alarm circuits to indicate school/college class change 2. Programmable 5A 24V dc relay for remote signalling of fire or fault conditions. Selectable by jumper link. 3. Auxiliary 24V dc output power supply provided as standard for 8 zone panel and 2 and 4 zone configured panels. Detection Capacity 1. Up to 32 detectors per zone. End of line monitoring devices must be fitted and are supplied as standard. 2. Detector circuits are monitored for open circuit, short circuit and detector removal. Alarm Capacity 1. 2 separate alarm lines on 1, 2 and 4 zone panels. Maximum rated load of 150mA (1and 2 zone) or 400mA (4 zone) per line. 2. 4 separate alarm lines on 8 zone panel. 500mA maximum load per line. 3. Alarm lines are monitored for open circuit and short circuit faults. 4. Additional alarm line facilities on custom 2 and 4 zone configured panels. Repeater Panel 1. Repeater matches the style and appearance of main control panels. 2. Facility for signalling to repeater panel provided as standard on 8 zone panel. 3. Specially configured versions of 2 and 4 zone panels available for use with a repeater panel. 4. Displays essential information at other key locations in a large building/site Zone fire and fault conditions Test mode in operation Zones or alarm lines in disabled mode 5. Repeater panel requires only a single pair of wires to receive signals from main control panel, plus local mains power supply, reducing cost of installation. 35

Conventional Control Panel - FX2200 Range Standard Panel Connections - FX2201, FX2202 and FX2204 1 2 3 1 2 3 EOLM-1 DETECTORS AND CALLPOINTS (REFER TO INDIVIDUAL WIRING DIAGRAMS) END OF LINE RESISTORS (6K8) DETECTORS AND CALLPOINTS (REFER TO INDIVIDUAL WIRING DIAGRAMS) 1 2 3 1 2 3 EOLM-1 AUXILLARY RELAY AS PER ZONES 1 & 2 L N E CLASS CHANGE + - + - SOUNDER CIRCUITS NO C NC + - + - + - + - 1 2 3 4 ZONE CIRCUITS Standard Panel Connections - FX2208 1 2 3 1 2 3 EOLM-1 DETECTORS AND CALLPOINTS (REFER TO INDIVIDUAL WIRING DIAGRAMS) END OF LINE RESISTORS (6K8) DETECTORS AND CALLPOINTS (REFER TO INDIVIDUAL WIRING DIAGRAMS) 1 2 3 1 2 3 EOLM-1 FAULT RELAY VOLT FREE NORMALLY OPEN CONTACTS AS PER ZONES 1 & 2 OUTPUT TO REPEATER PANEL F3 L N E NO C NC + - + - + - + - F4 AUXILLARY SOUNDER CIRCUITS F1 CIRCUIT F4 F3 CLASS CHANGE + - + - + - + - + - + - + - + - 1 2 3 4 5 6 7 8 ZONE CIRCUITS + - 24V dc SUPPLY Tx+ Tx- REPEATER OUTPUT 36

Conventional Product Range FX4200 Range Control Panels FX4208 control panel FX4204 control panel multiple top entry cable gland facilities Overview The JSB FX4200 range are high specification conventional control panels designed for a wide variety of building types and sizes. Available in a choice of 2, 4 and 8 zone versions, the FX4200 range is designed for ease of installation and simple operation. The FX4200 range are easy to use, with a simple one-shot test facility to ensure regular mandatory testing can be quickly and regularly accomplished. Other standard features, such as class change, zone or sounder circuit disabling and programmable relay output facilities complete a highly competitive solution. Features 2, 4, or 8 zone panels Competitive system Simple one-shot auto-reset user test facility Programmable fire/fault output relay Zone/sounder circuit disabling Supplied complete with batteries and end of line devices Benefits Simple to Install Understandable end user controls Comprehensive monitoring with LED display 37

Conventional Control Panels - FX4200 Range Technical Specification FX4202 FX4204 FX4208 2 Zone control panel 4 Zone control panel 8 Zone control panel Standards EN54 Pt2 & Pt4 1998, EN54 Pt2 & Pt4 1998, EN54 Pt2 & Pt4 1998 EN50130 Pt4:1996, EN500081 Pt1:1992 & EN61000 Pt2:1994 EN50130 Pt4:1996, EN500081 Pt1:1992 & EN61000 Pt2:1994 Specification Number of Zones 2 4 8 Number of Detectors per Zone 20 20 32 Number of Alarm Circuits 2 2 2 Alarm circuit load 150mA per circuit. 300mA total 400mA per circuit. 800mA total 400mA per circuit. 800mA total End of Line Devices Detection circuits: EOLM-1 monitoring unit. Detection circuits: EOLM-1 monitoring unit. Detection circuits: EOLM-1 monitoring unit. Alarm lines: 6.8K resistor Alarm lines: 6.8K resistor Alarm lines: 6.8K resistor Auxiliary Fire Signal/Fault Output Single pole changeover contacts ratings: 5A 24V dc Single pole changeover contacts ratings: 5A 24V dc Changeover contacts ratings: 5A 24V dc Auxiliary dc output 24V dc fused. 30mA 24V dc fused. 30mA 24V dc fused. 30mA Mains Input Voltage 230V ac +10%-15% 230V ac +10%-15% 230V ac +10%-15% Operating Voltage 24V dc 24V dc 24V dc Standby Duration 24 hours 24 hours 24 hours Battery 1 x 12V 4Ah (sealed lead acid battery) 1 x 12V 4Ah (sealed lead acid battery) 1 x 12V 7Ah (sealed lead acid battery) Recharge Period 24 hours 24 hours 24 hours Environmental Operating Temperature -5 C to +40 C -5 C to +40 C -5 C to +45 C Humidity (non condensing) 0 to 75% RH 0 to 75% RH 0 to 75% RH Physical Construction ABS / Polycarbonate front and metal back box ABS / Polycarbonate front and metal back box ABS / Polycarbonate front and metal back box Dimensions (H x W x D) 300mm x 300mm x 74mm 300mm x 300mm x 74mm 270mm x 395mm x 90mm Weight 4.8kg 4.8kg 7kg Cable Entry Top: 10 x 20mm conduit entries Top: 10 x 20mm conduit entries Top: 18 x 20mm entries Bottom: 1 x 20mm conduit entry (mains cable) Bottom: 1 x 20mm conduit entry (mains cable) Back: cable entry aperture Back: 1 x mains cable entry slot Back: 1 x mains cable entry slot Dimensions D W H (mm) W (mm) D (mm) 2 zone panel 300 300 74 4 zone panel 300 300 74 8 zone panel 396 270 90 H Product s FX4202 FX4204 FX4208 MFALOG Conventional 2 zone control panel Conventional 4 zone control panel Conventional 8 zone control panel Fire alarm system log book 38

Conventional Control Panels - FX4200 Range Installation 1. A full set of installation instructions is supplied with each panel to assist the installer to carry out maintenance work efficiently and safely and for the user to perform routine tests. 2. Panels are wall mounted via keyhole slot mounting holes on back of housing. 3. Mains power supply cable must be routed via the designated 20mm conduit entry on the top or bottom of the housing, or via the rear cable entry slot. The mains terminal block is provided with fuse protection. 4. A total of 10 x 20mm conduit entries are provided on the top of the housing for zone, alarm and output cables. Blanking plugs are supplied for unused entries. 5. Standby battery connected via push-on terminal connectors. 6. End of line (EOL) devices are supplied with the panel and must be fitted at the end of each detector and alarm circuit. 7. Front cover retained by anti-tamper screws System Functionality 1. Normal and supervisor mode facility. Supervisor mode protected by 4 digit security code to prevent unauthorised use. 2. Supervisor mode provides access to test mode, where a one-shot test facility can be initiated by the user. When in operation, the user has a short period of time in which to put a call point into fire condition, after which the system automatically resets and returns to normal mode. 3. Commissioning walk test feature permits the system to be easily tested after installation. The panel automatically resets and returns to normal operation after a detection device has been tested. Each device can then be tested in turn via the same procedure. 4. Supervisor mode also provides facility to disable the following for maintenance or other purposes: each detection zone independently. the alarm circuits. Interface Options 1. Class change input facility. Terminals provided for switching of alarm circuits to indicate school/college class change. 2. Programmable 5A 24V dc relay for remote signalling of fire or fault conditions, selectable by jumper link. 3. Auxiliary 24V dc output power supply provided as standard. Detection Capacity 1. Up to 20 detectors per zone on 2 and 4 zone panels, 32 on the 8 zone panel. End of line monitoring devices must be fitted and are supplied as standard. 3. Detector circuits are monitored for open circuit, short circuit and detector removal. Alarm Capacity 1. Two separate alarm lines, with a maximum rated load of 150mA (2 zone) or 400mA (4 and 8 zone) per circuit. 2. Alarm lines are monitored for open circuit and short circuit faults. User Interface 1. Attractive compact panel with simple 5 button keyboard control of all functions. 2. Simple one-shot weekly user test with auto-reset facility. 3. Comprehensive power, fire and fault LED indicators and integral piezo buzzer for on-board fire or fault indication. 4. Battery high/low voltage alarm facility. 39

Conventional Control Panels - FX4200 Range Standard Panel Connections - FX4202 and FX4204 1 2 3 1 2 3 EOLM-1 DETECTORS AND CALLPOINTS (REFER TO INDIVIDUAL WIRING DIAGRAMS) DETECTORS AND CALLPOINTS (REFER TO INDIVIDUAL WIRING DIAGRAMS) END OF LINE RESISTORS (6K8) 1 2 3 1 2 3 EOLM-1 AS PER ZONES 1 & 2 L N E + - + - + - + - + - + - 1 2 3 4 CLASS SOUNDER CHANGE CIRCUITS ZONE CIRCUITS 1 2 3 AUXILLARY RELAY Standard Panel Connections - FX4208 1 2 3 1 2 3 EOLM-1 DETECTORS AND CALLPOINTS (REFER TO INDIVIDUAL WIRING DIAGRAMS) DETECTORS AND CALLPOINTS (REFER TO INDIVIDUAL WIRING DIAGRAMS) END OF LINE RESISTOR (6K8) 1 2 3 1 2 3 EOLM-1 FIRE RELAY FAULT RELAY AS PER ZONES 1 & 2 L N E NC C NO AUXILLARY CIRCUIT NO C NC AUXILLARY CIRCUIT + - + - + - + - + - + - + - + - + - + - 1 2 3 4 5 6 7 8 ZONE CIRCUITS CLASS CHANGE SOUNDER CIRCUITS 40

Conventional Product Range Repeater Panel FXRP2200 FXRP2200 repeater panel Overview To complement the JSB FX2200 range a repeater panel is available for connection to the 4 and 8 zone panels. This repeater has been specifically designed for ease of installation requiring only 2 interconnecting wires from the main panel this compared with up to 16 wires on many conventional panels represents a large cost saving both on material and labour. Further repeater panels can be cascaded. again only using 2 wires. With stand by time not effected by the number of repeaters connected to each panel as each repeater has its own main supply and stand by battery. The repeater is suitable for up to 8 zones and displays all the same functions as the main panel, but with the addition of a indicator test facility. Features Facility for signalling to repeater panel provided as standard on 8 zone panel Charger with built in temperature compensation Displays essential information at other key locations in a large building/site Zone fire and fault conditions Test mode in operation Zones or alarm lines in disabled mode Benefits Repeater matches the style and appearance of the main control panel Repeater panel requires only a single pair of wires to receive signals from main control panel, plus local mains power supply, reducing cost of installation Cost saving 41

MUTE SCROLL BUZZER Conventional Repeater Panel - FXRP2200 Dimensions H D2 D1 W 1 2 3 4 5 H (mm) W (mm) D1 (mm) D2 (mm) 212 260 45 77 Technical Specification FXRP2200 Repeater Panel Specification Distance 2km Mains Input Voltage 230V ac -15%, +10% Standby Duration 24 hours Battery 1 x 12V 1.2Ah Recharge Period 24 hours Environmental Operating Temperature -5 C to +40 C Humidity (Non Condensing) 75% max Physical Construction PC Dimensions (H x W x D) 212mm x 260mm x 122mm Weight 3.6kg Ingress Protection IP30 Compatibility Suitable for use with JSB Conventional Fire Systems Installation 1. Wall mounted by means of 4 fixing screws. 2. Cable entry at back. 3. 12 top entry gland holes with push out blanking plugs. 4. 4 separate rear access cable entry facilities. 5. Local mains supply required and must be routed via the designated 20mm conduit entry in the top or the rear of the housing. Device Overview 1. Supplied with integral power supply and standby battery. System Functionality 1. Supplied with integrated power supply and stand by battery. 2. Provides local indication of essential information e.g fire, fault and disablement. 3. Suitable for use with FX2202CR / FX2204CR / FX2208 control panels. Standard Connection MAX CABLE LENGTH 2km RECOMMENDED CABLE SIZE 1.00mm² L N E + - REPEATER OUTPUT CONNECTIONS L N E + - LINE INPUT CONNECTIONS + - LINE OUTPUT CONNECTIONS CONTROL PANEL REPEATER PANEL Product s FXRP2200 Conventional Repeater Panel 42

Conventional Product Range Detectors optical / photo-thermal / heat detectors innovative light pipe technology allows LED to be seen from any angle Overview The JSB range of conventional detectors have been specifically designed to operate with JSB control panels. The JSB optical detector FXN533 is suitable for most applications giving the fastest response to slow burning or smouldering fires which give rise to large visible smoke particles. The JSB photo-thermal detector FXN632 will respond quickly to fast clean burning fires yet maintain the advantage of optical detectors when detecting smouldering fires. The thermal enhancement of this detector allows a higher alarm threshold which provides a greater rejection of false alarms. The detector will also raise an alarm at temperatures exceeding 60ºC. The JSB fixed heat detectors FXN524 and FXN526 will detect temperatures above 77ºC and 92ºC. The rate of rise heat detector FXN525 is used to detect rapid increases in temperature with a maximum threshold of 60ºC. These detectors are designed to be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions. Features Quick and simple to install Stylish low profile design 360º viewable LED Removable detector chamber Drift compensation Benefits Clean me feature means detector can be cleaned on site using the JSB manual cleaning procedure Common mounting base Positive lock indication 43

Conventional Detectors Technical Specification FXN533 FXN632 FXN525 FXN524 FXN526 Optical smoke Detector Photo-thermal detector Rate of rise detector Fixed heat detector (77ºC) Fixed heat detector (92ºC) Standards EN54 Pt7 2000, A1 2002 EN54 Pt 5 & Pt 7 2000, A1 2002 EN54 Pt 5 2000, A1 2002 EN54 Pt 5 2000, A1 2002 EN54 Pt 5 2000, A1 2002 Supply Ratings Operating Voltage 15V dc to 30V dc 15V dc to 30V dc 15V dc to 30V dc 15V dc to 30V dc 15V dc to 30V dc Standby Current 30µA (max) 30µA (max) 30µA (max) 30µA (max) 30µA (max) Startup Current 340µA (max) 340µA (max) N/A N/A N/A Alarm Current 25mA (max) 25mA (max) 25mA (max) 25mA (max) 25mA (max) Fixing Information Mounting Position Ceiling in open areas Ceiling in open areas Ceiling in open areas Ceiling in open areas Ceiling in open areas Mounting Options Surface mount with FXN520 base Surface mount with FXN520 base Surface mount with FXN520 base Surface mount with FXN520 base Surface mount with FXN520 base Area Coverage 100m² (subject to local standards) 100m² (subject to local standards) 50m² (subject to local standards) 50m² (subject to local standards) 50m² (subject to local standards) System Wiring 2 Core 2 Core 2 Core 2 Core 2 Core Operation Detection Mode Light scatter principle Light scatter principle & Heat sensitive element Heat sensitive element Heat sensitive element Heat sensitive element Heat Class N/A A2S A2R BS CS Alarm Temperature N/A 60ºC 60ºC 77ºC 92ºC Indication 360º visible LED 360º visible LED 360º visible LED 360º visible LED 360º visible LED Environmental Operating Temperature -20ºC to 60ºC -20ºC to 45ºC -20ºC to 45ºC -20ºC to 60ºC -20ºC to 75ºC Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH 0 to 93% RH 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS PC/ABS PC/ABS PC/ABS Colour White White White White White Dimensions Excl Base (Dia x H) 101mm x 33mm 101mm x 43mm 100mm x 43mm 101mm x 43mm 101mm x 43mm Dimensions Incl Base (Dia x H) 101mm x 45mm 101mm x 55mm 100mm x 55mm 101mm x 55mm 101mm x 55mm Ingress Protection IP40 IP40 IP40 IP40 IP40 EMC CE Marked CE Marked CE Marked CE Marked CE Marked Compatibility Suitable for use with JSB conventional fire systems JSB conventional fire systems JSB conventional fire systems JSB conventional fire systems JSB conventional fire systems Dimensions Installation User Interface D Dia 1. Detectors are fixed and wired via common mounting base. 2. Cable entry into base can be rear or side. 3. A locking facility is provided which can be activated if required to prevent unauthorised detector removal without the use of a special tool. 4. Positive click mechanism incorporated to provide clear indication when detector is correctly located in base. 1. Red LED to indicate alarm condition. 2. Amber LED to indicate chamber fault/drift compensation limit (enhanced versions only). 3. All wiring connections are via a common mounting base (supplied separately). Dia (mm) D (mm) D (mm) (excl base) (incl base) Optical 101 33 45 Photo-thermal 101 43 55 Heat 101 43 55 Note: For wiring information please see FXN520 Base Product s FXN533 FXN632 FXN525 FXN524 FXN526 FXN520 MDP201 Conventional optical smoke detector Conventional photo-thermal detector Conventional rate of rise heat detector Conventional fixed heat detector (77 C) Conventional fixed heat detector (92 C) Conventional detector base Duct Probe 44

Conventional Product Range Standard Base FXN520 Suitable detectors for use with the FXN520 standard base FXN533 optical detector FXN520 standard base FXN632 photo-thermal detector FXN525, FXN524, FXN526 heat detectors Overview The FXN520 conventional standard base has been specifically designed to be compatible with the JSB range of conventional detectors. This standard base has been designed for flexibility, simplicity and speed of installation. It incorporates purpose designed devices to provide fault warning if detector is removed whilst maintaining full zone wiring integrity. The base has a schotty diode in series with the negative terminals to enable fault monitoring and allow the circuit to continue if a detector is removed. Features Quick and simple to install Separate zone in and zone out terminals Stand off fixing feature Selectable detector locking Benefits Accepts side entry surface cables Common base for JSB conventional detectors 45

Conventional Standard Base - FXN520 Dimensions Technical Specification D Dia (mm) D (mm) 104 22 Physical Construction FXN520 Standard base PC/ABS Colour White Dimensions (Dia x D) 104mm x 22mm Compatibility Suitable for use with JSB conventional detectors Dia Installation Interface Options 1. Base incorporates a retaining clip to provide positive feedback when detector is correctly fitted. 2. Separate terminals are provided for zone in and zone out connections. 3. Each terminal can accept up to 2 x 2.5mm cables 4. Base incorporates a substantial cable entry aperture in the rear of the base. 5. Breakouts are provided to enable the detector base to sit neatly over surface cables and then enter via the rear entry aperture. 6. Base mounting incorporates a stand off feature to help prevent distortion when mounted on an uneven surface. 7. Fixings are suitable for standard BESA box or direct fixing to suitable surface 8. Optional locking devices (supplied with base) to prevent unauthorised detector removal. 1. JSB conventional detectors and bases support the use of a remote LED (optional extra FX251D). Standard Connection + VE + remote indicator (optional) Compatible JSB Conventional Control Panelsl -ZONE + 2 1 LED 3 E 4 2 1 LED 3 E 4 EOLM-1 end of line monitor device - VE Product s FXN520 FX251D Conventional standard base Conventional remote indicator 46

Conventional Product Range Relay Base FXN520R Suitable detectors for use with the FXN520R relay base FXN533 optical detector FXN520R relay base FXN632 photo-thermal detector Overview The FXN520R conventional relay base has been specifically designed to be compatible with the JSB range of conventional detectors. This relay base as been designed for flexibility, simplicity and speed of installation. It provides a local relay signal in the event of its host detector being triggered, making it ideal for instigating a local response. Features Quick and simple to install Designed specifically for use with JSB detectors Provides remote signal for external interfacing Benefits First fix mounting plate for ease of installation Local control output from host detector FXN525, FXN524, FXN526 heat detectors 47

Conventional Relay Base - FXN520R Dimensions Technical Specification Dia (mm) D (mm) 102 40 Specification FXN520R Relay base Relay Contact Rating 1A at 24V dc D Relay Trigger Source Detector remote LED output Detector Locking Facility Supplied as standard Physical Construction PC/ABS Colour White Dia Dimensions (Dia x D) 102mm x 40mm Compatibility Suitable for use with JSB conventional detectors Installation 1. Relay base is supplied with a first fix fixing plate. 2. Fixing plate has a central cable aperture. 3. Cable entry is from rear. 4. Main body is then clipped into place on base, body locks into place when pressed into position. Interface Options 1. JSB conventional detectors and bases support the use of a remote LED (optional extra FX251D). System Functionality 1. Relay is controlled by status of host detector. 2. If host detector is triggered relay activates. Standard Connection + VE + remote indicator (optional) Compatible JSB Conventional Control Panelsl -ZONE + 2 1 LED 3 E 4 2 1 LED 3 E 4 EOLM-1 end of line monitor device - VE Product s FXN520R FX251D Conventional relay base Conventional remote indicator 48

Conventional Product Range Remote Indicator FX251D FX251D remote indicator Overview The FX251D conventional remote indicator is designed to provide discreet remote indication for use with JSB conventional detectors. The remote indicator is ideal for applications such as void spaces or outside locked or inaccessible rooms to provide indication of the activation of an automatic detector. Features Quick and simple to install Wide viewing angle high brightness LED Aesthetically pleasing design Benefits High visibility LED Fits onto standard single gang back box 49

Conventional Remote Indicator - FX251D Dimensions Technical Specification D H (mm) W (mm) D (mm) 87 87 30 Environmental FX251D Remote indicator Operating Temperature -10 C to +55 C H Humidity (Non Condensing) 0 to 95% RH Physical Construction ABS Colour White W Lens Colour Red Dimensions (H x W x D) 87mm x 87mm x 30mm Weight 0.28kg Ingress Protection IP30 Compatibility Suitable for use with JSB conventional fire systems Standard Connection Installation System Functionality FX251D Compatible JSB Conventional Control Panelsl -ZONE + + VE 2 1 + LED 3 E 4 remote indicator (optional) 1. Mounting plate fixes to single gang back box or can be direct fixed to wall or ceiling. 2. Cable entry is normally from rear but breakouts are provided in side of base plate 3. Cables connect to terminals on PCB within base plate. 4. Front cover is pushed onto base plate and locks in place. 1. FX251D is connected to an individual detector. 2. FX251D activates if detector is triggered. 3. LED cancels when detector is reset. 4. Low current consumption. - VE DETECTOR BASE IN + - WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Product s FX251D M1R195B Conventional remote indicator Conventional remote indicator (with buzzer) 50

Conventional Product Range Callpoints FX201 and FX203 FX201 callpoint Overview This attractively designed, simple to install, range of callpoints have been specifically developed to be compatible with JSB conventional fire panels. There are 2 versions of callpoint in this range. The FX201 which can be either surface or flush mounted and the FX203 which is a weatherproof version. All callpoints are supplied as standard with a frangible glass element and a test key for ease of maintenance. Features High visibility status LED Standard and weatherproof versions available Heavy duty terminals Benefits Quick and simple to install Fast fit clip on front cover Single tool for test and access A comprehensive range of accessories are available to maximise the functionality of the callpoint for particular applications. 51

Conventional Callpoints - FX201 and FX203 Dimensions H D H (mm) W (mm) D (mm) Flush mounted 87 87 36 Surface mounted 87 87 57 Weatherproof 87 87 59 W Technical Specification FX201 FX203 Surface/flush mount callpoint Weatherproof callpoint Standards EN54 Pt11 EN54 Pt11 Specification Operating Voltage 18V dc to 30V dc 18V dc to 30V dc Environmental Operating Temperature -10 C to +55 C -25 C to +70 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS Colour Red Red Dimensions (H x W x D) 87mm x 87mm x 57mm (36mm flush) 87mm x 87mm x 59mm Weight 0.2kg 0.2kg Ingress Protection IP24D IP65 Compatibility Suitable for use with JSB conventional fire systems JSB conventional fire systems Standard Connection FX201 / FX203 Compatible JSB Conventional Control Panel COMMON 680Ω + + - - WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable Installation 1. Surface callpoint has standard rear BESA fixing facilities. In addition, back box can accept top or bottom surface entry cables. Surface callpoint can also be flush mounted. 2. Callpoint has test facility via special test key to prevent unauthorised operation. 3. Insertion of test key for test purposes and for cover removal is at bottom of callpoint to facilitate ease of access when mounted next to door architrave. 4. Test key is dual function, used to test callpoint operation by simulating activation and also to allow removal of clip on cover to gain access to element. 5. Element is held in place by clip on self locking cover which can only be removed by use of a special tool (callpoint test key). 6. Separate zone in and zone out terminals are provided for all connections. 7. Surface/flush callpoints are IP24D, weatherproof is IP65. User Interface 1. To enable quick and simple installation, callpoints use a fast fit self locking clip on front cover which is very simple to fit, but once in place, can only be removed by use of a special key (supplied). 2. Callpoint is triggered by pressing against the element. Product s FX201 Conventional surface/flush callpoint FX203 Conventional weatherproof callpoint FX5G Spare break glasses (pack of 5) 52

Conventional Product Range Bell FX006 FX006 Internal bell Overview Bells still remain a popular choice for many applications such as schools where they can sometimes be used as a signal for non fire purposes such as class change. The FX006 internal bell incorporates highly efficient rotary centrifugal movements combining high sound output with low current consumption. Features Quick and simple to install High sound output Low current consumption Multi-fixing base plate Benefits Can be used for non fire applications 53

Conventional Bell - FX006 Dimensions Technical Specification D Dia (mm) D (mm) 152 63 Standards FX006 Internal 6 Inch bell EN54 Pt3 Specification Dia Operating Voltage Current Consumption 24V dc 25mA at 24V dc Sound Output 93-95dB(A) at 24V dc Environmental Operating Temperature -10 C to +55 C Humidity (Non Condensing) 0 to 93% RH Physical Construction gong - steel / base-polycarbonate Colour Red Dimensions (Dia x D) 152mm x 63mm Weight 0.85kg Ingress Protection IP21C Cable Entry Rear Compatibility Suitable for use with JSB conventional fire systems Standard Connection FX006 Compatible JSB Conventional Control Panel - - + + WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable Installation 1. Multiple rear fixing options, can be fixed direct to wall or mounted on suitable BESA box. 2. Cable entry into bell is from rear. 3. Incorporates heavy duty terminals suitable for 2.5mm cables. Device Functionality 1. Sound output is fixed and determined by size of the bell. 2. Operation is driven by an internal motor and striker arrangement. 3. Bells are polarised and suppressed. Product s FX006 Conventional internal 6 Inch bell 54

Conventional Product Range Flush Sounder FX003 and FX003W FX003W white flush sounder FX003 red flush sounder Overview The JSB discreet flush sounder is designed to be compatible with JSB conventional fire systems. These flush sounders provide an excellent combination of high sound output and discreet appearance. Ideal for retail, hotel and residential applications such as sheltered housing. Features Choice of colours Separate volume control Choice of tone is determined by selection of appropriate terminal for negative connection Benefits Quick and simple to install Low profile design 55

Conventional Flush Sounder - FX003 and FX003W Dimensions Technical Specification D W H (mm) W (mm) D (mm) 86 86 36 Standards FX003 Flush sounder EN54 Pt3 Specification H Operating Voltage Current Consumption 6V dc to 28V dc 20mA at 24V dc Sound Output 98dB(a) at 1 Metre (+/- 2) Environmental Operating Temperature -25ºC to +55ºC Humidity (Non Condensing) 0 to 95% RH Physical Construction ABS Colour Red / White Dimensions (H x W x D) 86mm x 86mm x 36mm Weight 0.3kg Ingress Protection IP20 Cable Entry Via separate back box Compatibility Suitable for use with JSB conventional fire systems Standard Connection FX003 / FX003W Compatible JSB Conventional Control Panel COMMON 1st SOUND 2nd SOUND + + - - - - Installation 1. Sounder fixes to a single gang deep back box 2. Fixing screws included. 3. Connections are to main sounder body. 4. Separate alarm line in and alarm line out terminals are provided. 5. For surface mount applications a separate red single gang box can be ordered separately. Interface Options 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable. NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal. Product s FX003 FX003W Conventional red flush sounder Conventional white flush sounder 56

Conventional Product Range Surface Sounders FX002 and FX002W FX002 low profile surface sounder, red Overview This general purpose conventional surface sounder has been specifically designed to work with JSB conventional control panels. Volume is adjustable via the internal volume control and 32 different alarm tone selections are provided. Depending on the selected tone, sound levels of up to 105dB(A) can be achieved. Features Low profile design Pre drilled cable entries Choice of colour, red or white 32 selectable tones Benefits Low current, high sound output Suitable for a wide range of applications Automatic synchronisation 57

Conventional Surface Sounders - FX002 and FX002W Dimensions D Dia Dia (mm) D (mm) 93 63 Technical Specification FX002 / FX002W Low profile surface sounder Standards EN54 Pt3 Specification Operating Voltage 9V dc to 28V dc Current Consumption 16mA at 24V dc Sound Output 105dB(a) max (+/-2) at 24V dc Number of Tones 32 Environmental Operating Temperature -25 C to +70 C Humidity (Non Condensing) 0 to 93% RH Physical Construction PC/ABS Colour Red / White Dimensions (Dia x D) 93mm x 63mm Weight 0.24kg Ingress Protection IP54 Cable Entry Rear Compatibility Suitable for use with JSB conventional fire systems Standard Connection FX002 / FX002W Compatible JSB Conventional Control Panel COMMON 1st SOUND 2nd SOUND + + - - - - Installation 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main sounder body. 5. Separate in and out terminals are provided. 6. Main body is pushed into sounder base and then twisted to lock into place. Interface Options 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. Options 1. Choice of tone setting (set via DIP switches can be altered at any time). WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable. NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal. Product s FX002 FX002W FX000WP FX000WWP Conventional low profile surface sounder, red Conventional low profile surface sounder, white Weatherproof deep base (IP65), red Weatherproof deep base (IP65), white 58

Conventional Product Range High Output Wall Sounder FX007 FX007 high output wall sounder Overview The JSB FX007 has a maximum output of 120dB(a) making it ideal for use in areas with high ambient noise levels. It is simple to install and uses a first fix back plate onto which the main body attaches with a self locking press fix assembly. Features Ideal for areas with high ambient noise Choice of tones Variable volume setting Benefits Quick ands simple to install High output sounder 59

Conventional High Output Wall Sounder - FX007 Dimensions Technical Specification D H (mm) W (mm) D (mm) 105 105 95 Standards FX007 High output wall sounder EN54 Pt3 Specification H Operating Voltage Current Consumption 18V dc to 30V dc 210mA to 260mA Sound Output 120dB(A) (+/- 2) Max at 1m (tone 5) 114dB(A) (+/- 2) Max at 1m (tone 3) W Environmental Operating Temperature -25 C to +70 C Humidity (Non Condensing) 0 to 95% RH Physical Construction ABS Colour Red Dimensions (Dia x D) 105mm x 105mm x 95mm Weight 0.28kg Ingress Protection IP42 Compatibility Suitable for use with JSB conventional fire systems Standard Connection FX007 Compatible JSB Conventional Control Panel + + - - Installation 1. First fix mounting plate is fixed to wall. 2. Cable entry is from rear, or top/bottom. 3. Connections are to main sounder body. 4. Separate alarm line in and alarm line out terminals are provided. Interface Options 1. Sounder operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable. Product s FX007 Conventional high output wall sounder 60

Conventional Product Range Xenon Beacons FX004R and FX004B FX004B low profile xenon beacon, blue lens FX004R low profile xenon beacon, red lens Overview This range of JSB xenon beacons is available to complement purely audible alarms for use in areas either where people may be present who have impaired hearing or areas with high ambient noise levels. Xenon beacons have a high light output to maximise the attention attracting potential of the device. Both the red lensed FX004R and blue lensed FX004B are low profile xenon beacons which feature a high performance light source and adjustable volume control. Due to predrilled fixing and cable entry holes they are simple to install. Features Unobtrusive low profile design High output xenon beacon Pre drilled cable entries entry holes Benefits First fix base Choice of lens colour 61

Conventional Xenon Beacons - FX004R and FX004B Dimensions Technical Specification D Dia Dia (mm) D (mm) 93 72 FX004R / FX004B Low profile xenon beacon Standards EN54 Pt3 Specification Operating Voltage 24V dc Current Consumption 45mA at 24V dc Operation Continuous Flash Energy 0.7J Flash Frequency 60 per minute Environmental Operating Temperature -20 C to +55 C Humidity (Non Condensing) 0 to 93% RH Physical Construction PC/ABS Colour Red Lens Colour Red / Blue Dimensions (Dia x D) 93mm x 72mm Weight 0.2kg Ingress Protection IP54 Cable Entry Rear Compatibility Suitable for use with JSB conventional fire systems Standard Connection FX004R / FX004B Compatible JSB Conventional Control Panel + + - - WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable Installation 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main beacon body. 5. Separate alarm line in / out terminals are provided. 6. Main body is pushed into sounder base and then twisted to lock into place. Interface Options 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. Product s FX004R FX004B FX004R Conventional low profile xenon beacon, red lens, 1 Watt Conventional low profile xenon beacon, blue lens, 1 Watt Conventional low profile xenon beacon, red lens, 2 Watt 62

Conventional Product Range Xenon Sounder Beacons FX002CR, FX002CA and FX002CB FX002CR low profile xenon sounder beacon. red lens Overview This range of JSB xenon sounder beacons is available to complement purely audible alarms for use in areas either where people may be present who have impaired hearing or areas with high ambient noise levels. Xenon sounder beacons have a high light output to maximise the attention attracting potential of the device. The key benefit of these devices is that an audible and a visual alarm are combined together and require only a single installation point. This greatly reduces installation time and cost and is much less obtrusive than 2 separate devices. Features Unobtrusive low profile design High output xenon beacon Pre drilled cable entries Sounder and beacon with a single installation point 32 selectable tones Benefits Combined audio / visual unit Single installation point Choice of lens colour The red lensed FX002CR, the amber lensed FX002CA and the blue lensed FX002CB are low profile xenon sounder beacons which feature a high performance light source and adjustable volume control. Due to predrilled fixing and cable entry holes they are simple to install. 63

Conventional Xenon Sounder Beacons - FX002CR, FX002CA and FX002CB Dimensions D Dia Dia (mm) D (mm) 93 92 Technical Specification FX002CR / FX002CA / FX002CB Low profile xenon sounder beacon Standards EN54 Pt3 Specification Operating Voltage 18V dc to 30V dc Current Consumption 68mA (av) 73mA (peak) Operation Continuous Flash Energy 0.7J Flash Frequency 60 per minute Sound Output 101dB(a) max (+/-3) at 24V dc Number of Tones 32 Environmental Operating Temperature -20 C to +55 C Humidity (Non Condensing) 0 to 93% RH Physical Construction PC/ABS Colour Red Lens Colour Red / Amber / Blue Dimensions (Dia x D) 93mm x 92mm Weight 0.25kg Ingress Protection IP54 Cable Entry Rear Compatibility Suitable for use with JSB conventional fire systems Standard Connection FX002CR / FX002CA / FX002CB Compatible JSB Conventional Control Panel 2nd SOUND - - 1st SOUND COMMON - - + + Installation 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main sounder beacon body. 5. Separate alarm line in / out terminals are provided. 6. Main body is pushed into sounder base and then twisted to lock into place. 7. Supply is common for sounder and beacon as it is a single unit. Interface Options 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable. NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal. Product s FX002CR FX002CA FX002CB FX000WP FX000WWP Conventional low profile xenon sounder beacon, red lens Conventional low profile xenon sounder beacon, amber lens Conventional low profile xenon sounder beacon, blue lens Weatherproof deep base (IP65), red Weatherproof deep base (IP65), white 64

Conventional Product Range Compact Door Retainer FX021240LC and FX02124VLC floor/wall mounting bracket compact door retainer door striker plate Overview JSB compact magnetic door retainers are competitively priced, simple to install and discreetly styled. They are ideal for a wide range of applications, such as nursing homes, hospitals and busy corridors. They enable doors to be held open under normal conditions but automatically be released in the event of fire alarm activation. Features Fast fit clip on cover Mains and 24V dc versions available Manual release facility Optional floor mounting bracket available Benefits Quick and simple to install Slim profile unit 65

Conventional Compact Door Retainer - FX021240LC and FX02124VLC Dimensions Technical Specification H W D H (mm) W (mm) D (mm) Magnet 71 108 44 Striker Plate 65 65 48 D W H FX021240LC FX02124VLC Mains powered compact door retainer 24V dc powered compact door retainer Specification Operating Voltage 230 V ac to 240 V ac 24V dc Power Consumption 1.2 VA 40mA Holding Force 45 kg 40 kg Environmental Operating Temperature -5 C to +54 C -5 C to +40 C Humidity (Non Condensing) 0 to 93 %RH 0 to 93 %RH Physical Construction PC/ABS PC/ABS Colour White White Dimensions (H x W x D) Magnet 71mm x 108mm 44mm 71mm x 108mm 44mm Striker Plate 65mm x 65mm x 48mm 65mm x 65mm x 48mm Weight 1.0 kg 1.0 kg Ingress Protection IP42 IP40 Compatibility Suitable for use with JSB conventional fire systems JSB conventional fire systems Standard Connection FX021240LC / FX02124VLC INPUT VOLTAGE TO DOOR RETAINER WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Installation 1. Door retainer unit and striker plate should be fixed to a smooth surface. 2. 16mm & 20mm cable entry facilities are provided at the top and both sides. 3. 10mm cable entry is provided at the rear 4. Fixings should be able to support at least double the holding force of the magnet. System Functionality 1. Designed to operate only with self closing doors. 2. Door retainer is fitted to wall or floor using floor bracket. 3. Striker plate is fitted to door. 4. Door retainer is fed with a constant supply via an external control device. 5. Supply energises an electromagnet, which holds the striker plate securely against the magnet. 6. If supply to magnet is interrupted, magnet de-energises. 7. Door closes under control of its own self closing device. Product s FX021240LC FX02124VLC FX021LCFB FASP0429 Conventional mains powered compact door retainer Conventional 24V dc compact door retainer Floor mounting bracket for compact door retainer 24V dc power supply 66

Ancillaries and Test Equipment Power Supply FX1A Overview The FX1A is a 24V dc battery backed power supply complete with back up batteries. The output is continuous and transition from mains to battery is without break in the output. It is monitored and has local fault indication as well as volt free contacts for remote fault signalling, making it ideal as a general purpose power supply for fire alarm applications. Features Compact enclosure Integral battery Fault indicator Remote fault contact Benefits Simple to use Secure steel enclosure Battery back up 67