IBC Technologies Venables Street, Vancouver, BC, V5L 2G8 - Ph Fax E -

Similar documents
- Data Brochure Boiler Control 274

prestige Control Application Supplement - TriMax

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

- Data Brochure Universal Reset Module 422

Hydronic & HVAC Control Systems

- Essay Control Functions and Benefits

prestige Control Application Supplement - TriMax

- Data Brochure Universal Reset Module 423

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

Better Design, Better Control, Better Systems.

- Data Brochure Boiler Control 264e

- Data Brochure Mixing Control 360

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

- Data Brochure D 260. Boiler Control /09

Control Application. Supplement - ACVMax

B-40/B-41 Modulating Temperature Controller

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5)

prestige Control Application Supplement - ACVMax

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

Dual Mixing Application

- Data Brochure Boiler Control 264

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

- Data Brochure Boiler Control 268

AFUE 95% Heating Input 50,000 to 200,000 Btuh

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223

Installation & Operation Manual

Installation & Operation Manual

- Data Brochure Steam Control 279

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

- Data Brochure Mixing Control 361

- Data Brochure Addendum

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

prestige Control Application Supplement WARNING

Installation & Operation Manual

- Data Brochure Addendum

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Outdoor Reset IQ Option Card, p/n

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

Project Name: Location: Engineer: Contractor: I. GENERAL

- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1

ADDENDUM TO LIT91127U EVO CONFIGURED IN ODD WATER SYSTEM DESIGN

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Installation & Operation Manual

prestige Control Application Supplement - Type 5 MCBA WARNING

Installation & Operation Manual

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

- Data Brochure Universal Reset Control 364

Hubbell NX500 High Efficiency Gas Condensing Water Heater

Addendum H to Brute LX 1295A Document 1372

Installation & Operation Manual

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Multi Boiler Guide. Kit #

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

USER MANUAL FOR OPERATING SYSTEM

INSTALLATION INSTRUCTIONS

prestige Control Application Supplement - Type 5 MCBA WARNING

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Cascade Sequencer. Control Installation and Operation Instructions. Infinite Energy Boiler Manual. Also read and follow: CS-IOM-1

MULTI-PLEX. Engineered Easy to Install Turnkey System. Better Boilers FOR IBC SL BOILER. Lord Tweedsmuir School, BC

Advanced Snow Melt Control Installation Manual

INSTALLATION AND OPERATING INSTRUCTIONS IBC TECHNOLOGIES INDIRECT-FIRED WATER HEATERS

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Get The Edge Over The Competition with The Summit

Outdoor Reset IQ Option Card, p/n

TABLE B Remote Wire Connection

Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay. MZ308 Exquisite Heat Controller

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Versatility 96 % ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. DOE AFUE Efficiency.

EVERGREEN HIGH EFFICIENCY CONDENSING BOILER

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

V10 Controller - BACnet lnterface Supplement 1

Zoning Solutions. Thermostats & Wiring Centers Designed to Maximize Indoor Comfort. A Watts Water Technologies Company

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

AQ250 Series Hydronic Control Panels

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

Siemens Thermostats. RDY2000BN Thermostat

BB3000 Series. Application. Features. Injection Pump Control General Instructions

O CRC100. Comfort Room Controller (2015/01) en

EVERGREEN HIGH EFFICIENCY CONDENSING BOILER EASY HEAT, EFFORTLESS COMORT

Service Instructions for use by heating contractor

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

Proudly assembled in U.S.A

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q

Transcription:

TECHNICA NOTES October 2010 MUTIPE BOIER SYSTEMS Version 2.0 Technologies - 1543 Venables Street, Vancouver, BC, V5 2G8 - www.ibcboiler.com Ph - 604 877 0277 Fax - 604 877 0295 E - info@ibcboiler.com IMPORTANT: This memo applies only to boilers with software versions 2.23.1 and later. For boilers with earlier software versions, refer to Technical Notes - January 2009, Multiple Boiler Systems Version 1.0 fittings, hydronic specialties and venting components are also off the shelf equipment that can normally be readily sourced from local plumbing & heating wholesalers. From an operational point of view, the story even gets better. Please refer to our Multiple Boiler Case Studies brochure for some real world examples of the exceptional savings to be had from these types of installations. Multiple modulating, condensing boilers give the boiler plant an incredible turn down capability to respond to any building load condition imaginable. Four 45-225 boilers for example will allow load matching from an input of 45,000 Btuh all the way up to 900,000 Btuh. This right sizing to building load, increases energy savings dramatically. It is not uncommon to see fuel savings of over 50% in retrofit situations. Introduction The use of multiple condensing boilers for large input systems is an economical and easy way to upgrade older, inefficient boiler plants to attain outstanding energy savings. In new construction, as well, these boilers provide buildings with the highest heating system efficiencies possible. The advantages are numerous. From the installation viewpoint, using off the shelf boilers in place of large custom order commercial products can save considerable money, and eliminate the often lengthy lead times required for manufacturers to order, fabricate and ship their product to the site. Custom commercial boilers often require cranes and other specialized moving equipment and usually require hiring welders, millwrights and other high value trades to complete the installation. The smaller size of the wall mounted condensing boilers, means that in most cases the boiler room equipment can be moved into place and installed without special equipment using the mechanical contractor s in-house staff. Other boiler room components such as pumps, valves, Redundancy is also an important benefit of multiple boilers as individual boilers can be taken off line for service without impairing the operation of the rest of the boiler plant. s VFC 15-150 and 45-225 modulating models are set up for staging without any extra controls all that is needed is a 2-wire, shielded-twisted pair connection between controllers and simple control settings using the keypads. One master unit acts as the server, with the other subordinate units switched via the network connection. Heat calls and load pumps are wired into the master. Control settings are made to determine the staging sequence (rotation or fixed lead), call up parameters (staging delay) and sensor readings. Venting The roof is recommended for vent termination, doubly so with multiple units where steam plumes can be that much larger than from singe units. For sidewall applications, ensure a sterile wall is readily available (no windows, close neighbours), and ensure that should condensate drip from vent terminations, it will hot have adverse effects (including freeze-up) on objects or structures below. For roof top penetration of multiple boiler sets, options

are to group all intake terminals together for a common penetration through a custom cap, or to place them in close proximity, using commonly available pipe flashing. Alternatively, these boilers are certified to be installed using indoor combustion air (adequate combustion air to the boiler room must be provided by other approved means). Group the exhaust pipes and place the 2 separate 4 TO 8 (RECOMMENDED) AIR INTAKES MINIMUM 24 (REQUIRED) MINIMUM 36 (REQUIRED) EXHAUST VENTS 4 TO 8 (RECOMMENDED) groups (intake and exhaust) at least 3 apart. The closest intake and exhaust pipes shall be 36 or more apart. Ensure the outdoor combustion air intakes are downturned using 1 or 2 x 90 elbows. Exhaust termination pipes must be 24 minimum above the intake elevation whether roof or wall mounted. Condensate removal Do not common vent either intake or exhaust pipes. Flue gas condensate is mildly acidic. Condensate neutralization must be used when disposing condensate into drainage systems containing cast iron or copper pipe and fittings. In many buildings, the installer cannot be sure that cast iron or copper components have not been installed somewhere in the system. Although most municipalities will allow unmodified condensate to be drained directly into plastic sanitary drainage systems, we always recommend the use of acid neutralization for multiple boilers due to the larger volumes to be disposed of. In locations where large volumes of condensate are drained directly into a septic system, neutralization is also an important practice. Piping Use a Primary/ Secondary piping configuration as illustrated below. 4 STAGED BOIERS SINGE OAD SECONDARY OOP SENSOR (connect to Master boiler) Boiler #1 (Master) Boiler #2 Boiler #3 Boiler #4 BOIER BOIER BOIER BOIER CAUTION: This drawing is a simple schematic guide to a successful installation. There may be many necessary components not shown here. We require that our boilers be installed by licensed and experienced trades people who are familiar with the applicable local and national codes. System design is to be completed by an experienced hydronic designer or Engineer. It is necessary to carefully read and follow the installation instructions that come with the boiler along with the application drawing that fits your system. RETURN FROM HEATING SYSTEM SUPPY TO HEATING SYSTEM 2

Important Note: Each boiler pump must be under the control of its own unit. Each boiler attempts to perform a flow confirmation test prior to firing (VFC 15-150 and VFC 45-225 only); it looks for appropriate water pressure sensor readings while it cycles the pump on. If a boiler s pump is not under the direct authority of its corresponding boiler, an error no water flow message will be given, and the boiler will go into a two minute retry cycle. For optimum efficiency, and smooth operation in staging, we require multiple boilers be placed in a parallel piping arrangement so that all units receive the same (cool) return water temperature, and unblended outlet boiler water is supplied to the building loop. See boiler piping schematics in this bulletin. Use check valves to prevent induced circulation through off units. Control - General 2. There are several alternate methods for controlling a multi-boiler set: 1. The primary method involves identification of Master boiler which will receive all sensor and dry contact call-for-heat signals, manage any secondary pumps and via BoilerNet connection, supervise all subordinate boilers. This fully autonomous approach utilizes s internal heat regulation and boiler management software. The semi-autonomous BoilerNet option involves a remote analogue signal to the Master boiler s External Control terminals. This signal corresponds to a target set-point temperature, with the range Boiler #1 Master boiler Boiler #2 Subordinate boiler Green Yellow Black P/ V1 N P/ V2 N P/ V3 N P/ V Power N Interlock 1 Interlock 2 Therm. 1 Therm. 2 Therm. 3 Outdoor S. Indoor S. 2nd oop S. DHW S. Boiler Net Ext. Cont. Green Yellow Black P/ V1 N P/ V2 N P/ V3 N P/ V Power N Interlock 1 Interlock 2 Therm. 1 Therm. 2 Therm. 3 Outdoor S. Indoor S. 2nd oop S. DHW S. Boiler Net Ext. Cont. + + + + Auxiliary Interlocks (Jumper if not used) To System Pump (optional) Caution: Maximum 1/3 HP, 120Vac for larger loads use isolation relays Call for Heat (Jumper or connect to dry contacts of external control) Auxiliary Interlocks (Jumper if not used) Outdoor Sensor Boiler #1 Pump Secondary oop Sensor (required) DHW Sensor (Optional for DHW Applications) Note: Connect to Subordinate boiler for DHW opt out applications Boiler #2 Pump Boiler Net Wiring NOTE: Polarity Sensitive (use shielded-twisted pair wire) To other Subordinate Boiler Net terminals 120Vac G N G MUTIPE BOIER APPICATION BOIER NET WIRING 3

3. scaled according to the programmed min-max. s multi-boiler heat regulation algorithm still determines which boiler fires, throttle levels etc, but to an externally determined operating temperature. Call-forheat to the Master can be conveyed via a 1+ volt signal on the External Control terminal. The third method is classic-ddc control, involving separate dry-contact calls and throttle control signals to each boiler. Note that s heat regulation routine is subordinated to act solely in the limit protection role. Temperature regulation and boiler staging and rotation is handle over to the external DDC controller. Operational input can be delivered to each boiler via traditional methods (dry contact and external control inputs) or via s BoilerNet Interface Controller. The BIC provides both web or BACnet/IP interfaces to s boilers (all models). See BoilerNet Interface documentation. The majority of multi-boiler applications use the full autonomous method above, and the remainder of this Memo focuses on this option. It is important to note that this is appropriate for a single load application, or some 2-load systems. Three-load sequential management strategy, popular on single boiler residential systems do not typically scale up to larger multi-boiler applications. arge systems imply significant thermal masses which generally cannot change temperature quickly; it is also a standard code compliance requirement to meet such commercial scale loads continuously. For continuous multi-boiler / multi-load applications, there are two options: (1) running the system at the highest demanded temperature, with mixing down for cooler demands, or (2) s DHW Optout oriented to run large space heating jobs (reset or set point) plus indirect DHW tanks on separate / parallel primary loops. If simultaneous multiple load running (other than the DHW Optout) is called for, eexternal building control systems or stand-alone mix down or injection devices must be used to meet cooler temperature loads. Wire each boiler s primary pump to that boiler s primary pump-flagged harness lead (yellow and white wires found in the wiring box behind the control); this must be done in order for each unit to carry out its own flow integrity test prior to firing. Heating calls and secondary load pumps: Bring all thermostat, sensor and secondary pump leads to one unit typically the leftmost unit gets this treatment. This boiler will be declared as Unit 1 (Master boiler) in the software settings stage (below). Those familiar with the Multi-load software functions must note the following. It is important to be aware that the current multiple boiler operation at this time allows either for single load reset heating operation with domestic opt-out, or for single load only. If switching multiple loads such as reset heating, setpoint and domestic hot water on and off is required, controls such as building management systems or other external control systems such as tekmar s tn4 system must be utilized. The external system will look after any necessary mixing functions and load pump switching, and can connect to the Master boiler through the Therm. 1 contact input and the Ext. Cont. input. Sensors: 1. Settings For Reset Heating functions, connect one of the supplied outdoor sensors to the Master boiler at the Outdoor S terminals. There is no need to link up the other boilers with the outdoor sensors supplied with those boilers. 2. DHW sensor connect to the Master boiler only if the boiler plant will be dedicated entirely to DHW. Connect to opt out boiler(s) if opt-out option is to be used (see opt-out instructions further in this bulletin). Wiring Inter-boiler / network connection: Use polarity sensitive 2-wire leads (shielded twisted pair) to join one boiler to the next (to a maximum of 24 boilers). Connection is made between the Boiler Net terminals near the base of the orange terminal strip. Wiring between boilers need not be in any particular order, but good practice dictates a sequential daisy chain approach. See the wiring diagram below. Boiler pump connection: 3. Secondary loop sensor connect to Master boiler. Place a strap-on sensor (order from or use a tekmar 071 sensor) on the building loop, downstream of the injection point from the boiler plant into the system piping loop. A secondary loop sensor is a primary control requirement for coherent management of a multiple boiler set. The following pertains to on-board control applications, not DDC/externally controlled boilers: The key decision to be made is choice of the boiler staging condition e.g. at what point does an extra boiler 4

need to be called up. Note: drop-off condition is internal to software algorithm no settings required. The settable parameters are the length of time the user is willing to allow for the system to raise the system water temperature by a given amount. Default values in software as delivered: a loop temperature rise (toward Target) of 5 F or more over a 10 minute period will be treated as adequate progress without call-up of further boiler units. Account must be taken of the nature and size of the most sensitive load. If there is one large mass space heating function (an in-slab radiant floor or a commercial-scale heating / cooling loop), the default settings may be satisfactory. For large volume DHW service, this would be far too slow. Using the keypad of the intended lead boiler, go to Installer Setup and drop to the bottom line of the screen MultiBoiler Config.. Select this function using the centre button for enter. The programming procedure is as follows: 1. 2. When Master Boiler is highlighted, select and switch to On (for Master boiler only leave all other boilers set to Off ). at Boiler ID, select and using one push of the top button, increase the default value of 0 to 1. Go to the other boilers and assign 2, 3 and 4 (up to 24 units allowed). 3. 4. 5. 6. 7. 8. at Staging Delay (hh:mm), set minimum delay time before next boiler comes on line (must be at least equal to time for closed-loop water to complete one full circuit of system. For large mass systems, allow for two or more loop times. Boiler Rotation switch this to on to balance the run time on each of the boilers. There is a 48 hour maximum allowable runtime difference between boilers. Fixed ead When set to On, the Master boiler will always be the first to answer a call for heat. In the Off state, which ever boiler has the least run time will be the first to answer a new call for heat. Note: This feature is over-ridden when Boiler Rotation is enabled (treated as Off ). Firing switch between First On / First Off and First On / ast Off options. Note: this feature only works with modulating boilers. Fixed Fire Boiler Sel. this pertains to applications where one or more modulating boilers are grouped with on/off boilers within a single system. The lead boiler can switch up to 4 further on/off units when connected through the optional Multi- Mix harness and satellite module. To invoke, select then move the cursor over an asterisk and use the top button to arrive at 1. Repeat at the next asterisk for each further boiler involved. Must be set to **** when fixed fie boilers are not controlled by the master. Setup & configure heat loads on Master boiler. Helpful hint: To speed up confirmation of system operation, move the Staging Delay to 00:01 minutes to witness proper operation of the call up of other units. 5

Jumper removal When multiples of 3 or more boilers are configured, removal of a circuit board jumper as illustrated becomes necessary. This procedure must be completed for the boilers to stage and communicate properly with each other. 3. 4. 5. 6. ocate the jumper clips at the bottom right of the circuit board. There are two of them. The jumper on the bottom far right changes the Ext. Cont signal from 4-20mA (default) to 0-10VDC - do not remove this jumper. The jumper for configuring multi boiler operation is the one shown in the photo above. Pull this jumper clip straight away from two pins on the circuit board and store it somewhere safe in case it might be needed in the future. Common practice is to replace it so that it hangs onto the bottom pin only. Replace control board covers and restore power to the boilers. External DDC authority: Generally DDC systems are relied upon for staging of individual boiler units. Variations where multiples are linked to act as a virtual single are beyond the scope of this bulletin. 1. 2. Turn power off to the boilers. Remove the control board covers from each intermediate boiler in the array. CIRCUIT BOARD JUMPER REMOVA FOR NETWORKED MUTIPE BOIERS Boiler #1 (Master) Boiler #2 Boiler #3 Boiler #4 Boiler #5 Boiler #6 BOIER BOIER BOIER BOIER BOIER BOIER TWISTED PAIR WIRING CONNECTIONS DO NOT REMOVE JUMPER ON END BOIERS REMOVE JUMPERS FROM THE INTERMEDIATE BOIERS DO NOT REMOVE JUMPER ON END BOIERS 6

Domestic opt-out notes The domestic opt-out option was developed to increase the overall efficiency of a boiler plant, especially when operating in buildings that spend a large part of the Summer months and shoulder season in Summer shut-down mode. In traditional piping arrangements and control treatments, the building system pump would run continually, or a call for domestic hot water would result in the commencement of system pump operation. The boilers would subsequently fire and heat up the mains piping for the entire building, even for a short top up of the DHW tank - a significant waste of energy. The domestic opt-out function allows individual indirect storage water heaters to call up a single boiler to turn on a DHW boiler pump, divert its fluid flow and heat production directly to the tank, while turning off the boiler pump that injects heat into the heating mains, therefore bypassing the system piping. This operation all but eliminates piping losses. As a further benefit, when the boiler plant is operating in heating mode, the DHW boiler(s) can opt-out of the heating load, allowing the rest of the boiler plant to continue the heating task uninterrupted. If opt-out boilers are in the process of making DHW when a setpoint demand or heating demand is received by the master boiler, the remaining boilers will switch over to that load leaving the opt-out boilers to continue making DHW. If a DDC system or other external control is used to operate individual boilers the DHW opt out feature is unavailable. DHW opt out is still available when external (remote) setpoint control is used. Good design practice for an opt-out system dictates that the heat exchanger for the indirect tank be capable of transferring the full output of the boiler at high fire. This will result in fast recovery of the tank so that the boiler can return to the heating load quickly, and will allow the boiler to heat up the tank at lower delivery temperatures, enhancing condensation of flue products for maximum efficiency. 4 STAGED BOIERS WITH 2 BOIERS CONFIGURED FOR DOMESTIC HOT WATER OPT-OUT PRIORITY SECONDARY OOP SENSOR (connect to Master boiler) Boiler #1 (Master) BOIER Boiler #2 BOIER Boiler #3 BOIER Boiler #4 BOIER DHW DHW RETURN FROM HEATING SYSTEM SUPPY TO HEATING SYSTEM INDIRECT DOMESTIC HOT WATER HEATER INDIRECT DOMESTIC HOT WATER HEATER CAUTION: This drawing is a simple schematic guide to a successful installation. There may be many necessary components not shown here. We require that our boilers be installed by licensed and experienced trades people who are familiar with the applicable local and national codes. System design is to be completed by an experienced hydronic designer or Engineer. It is necessary to carefully read and follow the installation instructions that come with the boiler along with the application drawing that fits your system. 7

Boiler #1 Master boiler Boiler #2 Subordinate Opt-out boiler Green Yellow Black P/ V1 N P/ V2 N P/ V3 N P/ V Power N Interlock 1 Interlock 2 Therm. 1 Therm. 2 Therm. 3 Outdoor S. Indoor S. 2nd oop S. DHW S. Boiler Net Ext. Cont. Green Yellow Black P/ V1 N P/ V2 N P/ V3 N P/ V Power N Interlock 1 Interlock 2 Therm. 1 Therm. 2 Therm. 3 Outdoor S. Indoor S. 2nd oop S. DHW S. Boiler Net Ext. Cont. + + + + Auxiliary Interlocks (Jumper if not used) To System Pump (optional) Caution: Maximum 1/3 HP, 120Vac For larger loads use isolation relays Call for Heat (Jumper or connect to dry contacts of external control) Auxiliary Interlocks (Jumper if not used) Outdoor Sensor Boiler #1 Pump Secondary oop Sensor (required) Boiler Net Wiring NOTE: Polarity Sensitive (use shielded-twisted pair wire) Boiler #2 Pump DHW Opt-out Pump 120Vac G N DHW Call for Heat (Optional instead of DHW Sensor) Connect from dry contacts of external DHW Aquastat to Subordinate boiler for DHW opt out applications DHW Sensor (Optional for DHW Applications) Note: Connect to Subordinate boiler for DHW opt out applications To other Subordinate Boiler Net terminals G MUTIPE BOIER APPICATION DHW OPT-OUT WIRING DETAIS The software version is displayed briefly when the boiler is first powered up. In the example display shown below, it is clear that this boiler would require a software upgrade before it could be used in an opt-out application. DHW opt-out boilers cannot be configured as the Master boiler. On set-up, DEFINE OAD: DHW: OOP 2 Either a DHW sensor or aquastat can be used to generate call for DHW for each opt-out boiler. The call for DHW goes to each opt-out boiler separately. Contact the factory for information on software upgrade procedures. If the boilers were not specifically ordered with Software version 2.23.1 or higher, an field upgrade will have to be performed. 8