Certificate of Conformity

Similar documents
Certificate of Conformity

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

UL HAZARDOUS LOCATIONS SERVICES

IECEx Certificate of Conformity

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

ATM Lighting sp. z o.o

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

manual addendum DELPHI Ex

Flameproof Manual Call Points Series MCP

INSTRUCTION MANUAL (ATEX / IECEx)

Inductive slot sensor

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

TYPE APPROVAL CERTIFICATE

OPTIBAR DP 7060 Supplementary Instructions

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

User s Manual YTA610 and YTA710 NEPSI Certification

Operating Instructions

ATM Lighting sp. z o.o

Explosion-proof Immersion Heater Type D-8660

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

SOLUZIONI PER ATMOSFERA ESPLOSIVA

Manual Power relay SR853

OPTIWAVE X500 Supplementary Instructions

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

Certification Supplement Manual

Indoor/outdoor resistance thermometer Model TR60

Dräger Polytron 5100 EC Detection of toxic gases and vapors

IECEx Certificate of Conformity

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Certificate of Compliance

Temperature Measurement Transmitters for field mounting

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

Certificate of Compliance

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Flameproof Manual Call Points

INSTRUCTION MANUAL (ATEX / IECEx)

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

Flameproof Manual Call Points Series MCP

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Technical Data. General specifications. Rated operating distance s n 5 mm

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Survey of electrical equipment installed in hazardous areas on tankers

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Rosemount 848T High Density Temperature Measurement Family

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

ELECTRICAL EX EQUIPMENT

IECEx Certificate of Conformity

INSTRUCTION & SERVICE MANUAL

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

standards: standards:

Rosemount 644 Temperature Transmitter

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

TRASCO ATEX Couplings

IECEx Certificate of Conformity

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Operating Instructions for Rotor flow Indicator. Model: DKF

Electrical Installations Design, Selection, Erection and Inspection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

ANNEX GD-CERT-EX-EN SIT

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Switches compliant with ATEX directive

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Safety instructions VEGAPULS 64

Technical Data. Dimensions

Integrated Solutions Low Voltage Systems

Rosemount 3144P Temperature Transmitter

THE IMPORTANCE OF INSPECTIONS ON ELECTRICAL INSTALLATIONS IN HAZARDOUS LOCATIONS

Atmosphere. Introduction. explosion when exposed to a source of ignition. and IEC standards as follows:

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Easy installation Certified for zones 1 and 21 High IP degree of protection

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Transcription:

AWARDED TO APPLICANT SCHLEMMER GROUP EINSTEINRING 10 85609 ASCHHEIM DEUTSCHLAND MANUFACTURER: S.I.B (SCHLEMMER INDUSTRY AND BUILDING PARTS) 25 RUE THÉOPHILE SOMBORN 57220 BOULAY FRANCE Bureau Veritas Certification certify that the product constant at scope of supply below specified, has been assessed and find in accordance with requirements of documents of reference. Documents of Reference ABNT NBR IEC 60079-0:2013, ABNT NBR IEC 60079-7:2008, ABNT NBR IEC 60079-31:2014 and ABNT NBR IEC 60529:2017 CERTIFICATE ISSUED BASED ON THE MANUFACTURER EVALUATION OF QUALITY MANAGEMENT SYSTEM AND PRODUCT TESTS MODEL, ACCORDING TO CLAUSE 6.1 OF THE CONFORMITY EVALUATION RULE, ATTACHED TO THE ORDINANCE N 179 FROM INMETRO,ISSUED IN MAY 18 TH 2010. CABLE GLAND TYPE ECx MODELS: SIB-TEC MARKING: Ex e IIC Gb IP66/IP68 (5 bar) Ex tb IIIC Db IP66/IP68 (5 bar) Initial date of this cycle: MARCH 22 TH 2017. Certificate valid until: MARCH 21 ST 2020. This Certificate of Conformity was issued according to the certification model 5 and is valid only accompanied by pages 1 to 5. The validity of this Certificate is linked to carrying out assessments maintenance and treatment of possible non-conformity in accordance with the Bureau Veritas Certification guidelines and in the specific Inmetro Ordinances (RAC). To check the updated condition of regularity of this Certificate must be obtained from the product database and Certificate Services on Inmetro site. Product Certification Contract: BR.2719935. Certificate Number: BR230661-X. Número do Certificado INMETRO: Original approval Date: JUNE 13 RD 2011. Marco Antônio de Almeida Gomes Coordenador Técnico de Certificação de Produto Bureau Veritas Certification Avenida Alfredo Egídio de Souza Aranha, 100, Torre C, 3º andar Centro Administrativo Santo Amaro 04726-170, Chácara Santo Antônio, São Paulo, SP, Brasil www.bureauveritascertification.com.br tel.: 11 2655-9000 / fax: 11 2655-9322 1707051006001 1 Page 1 of 5 O uso da Identificação acima indica a acreditação com Relação às atividades cobertas pelo Certificado nº OCP-0018.

SPECIFICATION: The cable glands type EC x model SIB-TEC in plastic are designed to ensure Ex e and Ex t protection mode for round cable entry besides enclosure wall in metal or plastic. Clamping of the cable is realized by a sealing ring in neoprene. The cable gland is mounted eiher with a brass locknut or with a plastic lock-nut for specific cases. The cable glands can use in zones 1 and 2 for gas group IIA, IIB, IIC and for zones 21 and 22 for group IIIC for combustible dusts or not fuels. Three threaded types are used: ISO metric, NPT and PG. The table below describes the operating ambient temperature, the different sizes available and material used in function of cable gland size: Table 1: Models and Operating Ambient Temperature: Size SIB ADR materials used Metric PG NPT PA 66 PA 6 (Ref: A9380010 & A9380011*) (Ref: A93080003 & A9380008) 12 7 (1) / 16 9 3/8 (2) / 16 11 (2) / 20 13 ½ (2) / 20 16 (2) / 25 (2) / 25 21 ¾ (2) / 32 29 1 (2) / 40 36 (2) (2) a 50 42 (2) (2) a 63 48 (2) b (2) a (1) = -20 C Ta +80 C (2) = -35 C Ta +95 C (2)a = Do not use a locknut in brass; only a locknut in PA 6 25% fiberglass material. (2)b = Possibility to use a PA66 lock nut. * Blue cable glands made with plastic reference A9380011 shall be only used in intrinsically safe installation. 1707051006002 2 Page 2 of 5

TECHNICAL DOCUMENTATION: Certificate of Conformity Certificate of Conformity LCI 10.0008X of 2010/10/14; Certificate of Conformity LCI 10.0008X/02 of 2015/05/07; Certificate of Conformity LCIE 07 ATEX 6082X of 2007/10/16; Certificate of Conformity LCIE 07 ATEX 6082X/01 of 2008/04/14; Certificate of Conformity LCIE 07 ATEX 6082X/02 of 2008/07/10; Certificate of Conformity LCIE 07 ATEX 6082X/03 of 2009/09/08; Certificate of Conformity LCIE 07 ATEX 6082X/04 of 2015/05/07; Test Report LCIE n 98683-595881 of 2010/05/04; Test Report LCIE n 133536-668141-01 of 2015/05/07; Technical Dossier n TR/011/01 of 2011/02/30; Analysis Report (RA) n 001/2011 of 2011/03/14; Analysis Report (RA) n 001/2014 of 2014/06/16; Analysis Report (RA) n 001/2017 of 2017/03/16; Factory Inspection performed in 2017/03/08; Manual in Portuguese. Drawing Description Revision Date F 7000 000 E Presse-Etoupe Sib-Tec Ex e PG F 7000 000 E Kabelverschraubung Sib-Tec Ex e PG F 7000 000 E Cable Glands Sib-Tec Ex e PG F 7020 000 E Presse-Etoupe Sib-Tec Ex e Métrique F 7020 000 E Kabelverschraubung Sib-Tec Ex e Metrisch F 7020 000 E Cable Glands Sib-Tec Ex e Metric F 7030 000 E Presse-Etoupe Sib-Tec Ex e Métrique Long F 7030 000 E Kavelverschraubung Sib-Tec Ex E Metrisch Lang F 7030 000 E Cable Glands Sib-Tec Ex E Metric Long F 7040 000 E Presse-Etoupe Sib-Tec Ex e NPT F 7040 000 E Kavelverschraubung Sib-Tec Ex e NPT 1707051006003 3 Page 3 of 5

F 7040 000 E Cable Glands Sib-Tec Ex e NPT ASSEMBLY Sib-Tec ISO Ex e Cable Gland A 2010/04/28 MONTAGE Presse Etoupe Sib-Tec EX e Plastique ISO A 2010/04/12 OBSERVATIONS: 1. The letter X after the Certificate number means the following special conditions for safe use: The user must ensure proper locking of the cable near the cable entry. Do not use a locknut in brass; only a locknut in PA 6 25% fiberglass material for cable glands SIB TEC M40 to M63 and SIB TEC PG36 to PG48. Operating ambient temperature: -20 C Ta +60 C for all the range, -20 C Ta +80 C for the cable glands SIB TEC size M12 and PG7 or -35 C Ta +95 C for the rest of the SIB TEC range. The cable glands are approved with low mechanical impact, the applied impact energy was 4 J. 2. This Certificate is valid only for products with the same model and type as the tested prototype. Any modification in the project, as well as the use of components apart from those defined by the technical documentation, without previous authorization from Bureau Veritas Certification, will invalid this Certificate. 3. The cable glads shall be marked on the external surface and in a visible place, the conformity mark and the technical characteristics according to the specifications from standards ABNT NBR IEC 60079-0 / ABNT NBR IEC 60079-7 / ABNT NBR IEC 60079-31 / ABNT NBR IEC 60529 and the conformity assessment requiremnts, attached to INMETRO Ordince n 179, published in May 18 th 2010. This marking must be readable and durable, taking into consideration possible chemical corrosion. 4. The equipment must be installed in compliance with the relevant standards in electrical installations in explosive atmospheres and the manufacturer's recommendations 1707051006004 4 Page 4 of 5

5. The activities of installation, inspection, maintenance, repair, overhaul and recovery of equipment are the responsibility of users and must be implemented in accordance with the requirements of current technical standards and the manufacturer's recommendations. 6. The Manufacturer shall provide manual of installation and safe use written in Portuguese. REVISIONS HISTORY DATE DESCRIPTION 2011/06/13 Initial Issue 2014/06/17 Revision 1 Recertification 2017/03/20 Revision 2 - Recertification 1707051006005 5 Page 5 of 5