Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Similar documents
Reflective Optical Beam Smoke Detector User Guide

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

FIRERAY 5000 range USER GUIDE

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Motorised Infrared Optical Beam Smoke Detector. User Guide

TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Motorised Infrared Optical Beam Smoke Detector. User Guide

Table of Contents. 1. Mounting Tips... 2

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

D-Tect 2 GJD300 Quad PIR Movement Detector

Line Smoke Detector LRMX

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Installation and Operation Manual

End To End Optical Beam Smoke Detector. Additional Information

Open-area Smoke Imaging Detection (OSID)

Fireray 2000 Linear Smoke Detector

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

PHOTO-ELECTRIC BEAM DETECTOR MODEL SPB-ET INSTALLATION PROCEDURE

Reflective Beam Smoke Detector

INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

Apollo Intelligent Auto Aligning Beam Detector. User Guide

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

LUX Hardwired - Installation Notes

FDA241, FDA221 Siemens ASD

Movement Detector GJD 300

English. Italiano. Português. Françias. Español

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

IFD-E Flame Detector User Manual

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Emergi-Lite Orbis detectors

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

FDA241, FDA221 Siemens ASD

Description. Optex Incorporated

This training course discusses the correct use of Infrared (IR) Optical Beam Smoke Detectors for the protection of lives, equipment and property.

D-TECT Dual Tech. GJD360 Triple Technology External Detector

OPERATION AND INSTALLATION MANUAL

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

Installation Instructions Model CDC-4

English. Series. Installation and Use Manual

IFD-E Flame Detector User Manual

MODEL 6200 ANALOGUE ADDRESSABLE OPTICAL BEAM SMOKE DETECTOR

Fact File 66. Guide to Beam Smoke Detectors

Flame Detector User Manual

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

Open-area Smoke Imaging Detector. Engineering Specification

FR-A180 FR-A360. Occupancy detector. Use

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

E3M-V. Mark Sensor. Applications

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

DUAL OPTIC. Installation manual

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Installation, Operating and Maintenance Manual

LIGHTING TEF 9980 STATUS LIGHT, MAIN LIGHT & REPEATER LIGHT ZONE 1, ZONE 2 & SAFE AREA USER MANUAL

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

Open-area Smoke Imaging Detection (OSID)

OSID Smoke Detector. Product Guide. July 2011 Document No.: Revision: A Build: 4 Part No. LF42339

PHOTOELECTRIC REFLECTIVE BEAM DETECTOR MODEL SRA-ET. Mounting Guidelines

DI601AM Outdoor PIR/AM Detector Installation Sheet

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Class 1 laser beam sensor safe for your eyes

18W Round LED Wall/Ceiling Light with Microwave Sensor

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

12W Round LED Wall/Ceiling Light with Microwave Sensor

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

Installation Instructions

Installation And commissioning manual. Series S Double Beam 1/16

360 Surface Mount Ceiling PIR Light Controller

360º Surface Mount Ceiling PIR Light Controller

Beam detector DBD-DL40 KBD-DL80 KBD-DL100

this is by far the best beam money can buy

LiteFENCE Lite with SV Lite Sensor

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Class 1 laser beam sensor safe for your eyes

TS93 EMR WITH SMOKE DETECTOR

GAS SUPRESSION CONTROL PANEL:

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Commercial Series TriTech Motion Detector. Reference Guide

SENSA MRE DDM MR

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Transcription:

Fireray 2000 pplication and FETURES Installation Guide Range 10-100 metres 12V to 24V dc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or automatic reset

SYSTEM DESCRIPTION Fireray 2000 comprises of a transmitter which projects a modulated infra-red light beam onto a receiver unit. The received signal is analysed in the ground level controller. Should smoke be present in the beam for a period of approximately 8 to 10 seconds, a Fire relay is activated.the system is designed to be mounted so that the beam will project between 0.3 to 0.6 metres below and parallel to the roof or ceiling level at ranges up to 100 metres. The maximum lateral detection range is 7.5 metres either side of the actual beam. SMOKE DETECTION When smoke is present in the beam path the received signal is reduced by a level determined by the density of the smoke. In the event of the smoke reducing the signal strength by between the sensitivity level and 93% for a period between 8 to 10 seconds, the fire alarm relay is activated. This sensitivity level can be selected to suit different environments. The sensitivity levels available are: 25%, 35% and 50%. UTO RESET fter a fault condition is indicated, the control unit automatically resets if the fault is no longer present. The fire alarm relay may be latching or non-latching (close LRM switch for latching). UTOMTIC GIN CONTROL (GC) Long term degradation of signal strength by component ageing or build up of dirt on optical surfaces will not generate an alarm because of compensation provided by an GC circuit. This operates by comparing the received signal against a standard at predetermined time intervals. Differences of more than 7% are corrected by the automatic selection of gain stages. The GC time interval is factory set to nominally 1.5 hours. PRINCIPLE OF DETECTION The infra-red signal is transmitted from the Transmitter via an optical system. t 100m the diameter of this infra-red signal is 3m. This wide angle beam arrangement helps to simplify alignment and to give alignment stability. BEM DIVERGNCE OF FIRERY 2000 It is important that the Fireray is positioned correctly to minimise the detection time. Experiments have shown that smoke from a fire does not rise only directly upwards, but fans out as in a mushroom due to air currents and heat layering effects. fire alarm condition occurs when the smoke obscures the infrared beam. The time to signal a fire condition depends on the location of the Fireray within the premises, the volume of smoke produced, the construction of the roof and ventilation arrangements. For Firerays positioned beneath flat ceilings the smoke has to curl its way into the detection zone from the point on the ceiling directly above the fire. The time taken depends upon the distance of the fire from the beam axis, the height of the beam and source of the fire and the slope of the ceiling. 1

The maximum distance either side of the beam axis is found to be typically 7.5m for satisfactory detection under flat ceilings, providing a maximum total area coverage of (100 x 15) square metres. Smoke layering, where the smoke does not reach the ceiling level due to layers of static hot air above, is overcome by mounting the Fireray at the recommended height bringing the infra-red beam below the heat layer and into the smoke layer. The recommended installation height is between 30-60cms below the ceiling. However in all installations the national fire standards for that particular country must be consulted. If there is any doubt on the correct mounting height, positioning may be determined by smoke tests. SINGLE BEM See Note MULTIPLE BEMS 15m 30m Max 45m and over 7.5m 7.5m 0.5m Min 0.5m Min 15m 15m ceiling or roof with a slope in excess of 3.5 degrees should be regarded as an apex roof. Note1: No more than 3m of the beam path should be within 500mm of any wall or partitions. When Firerays are mounted in the apex the horizontal distance may be increased by 1% for each degree of ceiling slope, up to 25% maximum. (for Fireray in apex only). 10 10 SLOPING ROOF 7.5m 7.5m + 8.25m 8.25m + 7.5m 7.5m 30 30 SLOPING ROOF 18.75m Maximum (7.5 + 7.5 x 25%) RECEIVER ND TRNSMITTER SHOULD BE POSITIONED 0.3m to 0.6m BELOW THE CEILING 20 20 SLOPING ROOF 7.5m 15m 2 0.5m (See Note)

INSTLLTION Pre-installation at Ground Level 1. The Controller should be positioned so that it is accessible. The cable run connecting the Controller to the Receiver should not exceed 100m. Care should be taken that this cable is routed away from building electrical cables and any switchgear. 2. Controller: There are knock-out holes in the upper, lower and side faces for cable entries. Four 7mm fixing holes are located on the rear face, for installing the box to the building structure. Wiring connections are described on a label inside the controller door. See figure 1. 3. Select the required options, (sensitivity level, alarm relay latching/non latching, GC last stage operation (see figure 3). Transmitter 1. range adjuster (potentiometer) is accessed through a removable grommet. Receiver 1. The receiver should be installed such that lighting, artificial or natural sunlight, does not at any time fall directly onto the receiver lens. The Fireray is immune to most normal ambient lighting conditions. 2. Receiver to Control unit cable run must not exceed 100m (or be less than 5). Installation Transmitters and Receivers 1. The Transmitter must be in line of sight of Receiver and mounted rigidly on a secure section of the building. 2. Locate the right angle fixing brackets for the Transmitter and Receiver so that they are in the line of sight and are both installed equally 30-60 cms below the ceiling. 3. Install the Optical heads on the brackets and position in the line of sight. lign Rx as accurately as possible to the (by eye). 4. Install all cables and connect as figure 1. (Heads are supplied with 1m of cable. This should be correctly terminated with the System wiring). 5. Check that the RESET/TEST switch located in the Controller is in the ON position. 6. Position the Gain potentiometer in the Controller to the mid-way position. 7. pply the power to the system (check first that it is within limits 11.5-28 volts). 8. t this stage signal High or Low LED s may be illuminated. 3 The transmitter is set at 100 metres and should not be adjusted unless distances below 30 metres are required. In the event that a distance below 30 metres is required, adjust as follows: Fef. FIG. Place the screwdriver blade in the position shown. The blade should align with the 100 metre mark. (BLCK) Turn the screwdriver clockwise so that the blade points to the RED mark as shown in FIG. B.

lignment: Method Voltmeter 1. Connect the required length of two core cable to the test meter outputs and run to the Transmitter, connect a DC voltmeter (0 to 10V range) to this cable. 2. djust the Transmitter horizontally and vertically until the maximum reading is obtained, (no signal reading is approx 2.6V). 3. To avoid any possibility of working loose under vibration, tighten both the Transmitter thumbwheel screws securely, using a suitable coin or wide bladed screwdriver (Ensure it fills the thumbwheel slot completely to avoid slippage and damage). 4. t the Controller adjust the gain control potentiometer until the high LED just goes off. 5. Move the RESET/TEST switch to the off position. 6. Wait at least 45 seconds before performing any smoke tests. 7. Disconnect alignment cable. lignment: Method B FFE lignment id (Optional extra - Refer to factory) 1 Connect a temporary 3 core cable between the control Unit terminals and the lignment id:- Connect +VE SUPPLY from Control Board to red connector on lignment id. Connect -VE SUPPLY from Control Board to black connector on lignment id. Connect TEST METER+ from Control Board to yellow connector on lignment id. 2 Place the alignment aid in any convenient position, which is visible when viewed from the, with it s lamp pointing at the. 3 lign the and observe the lignment id (Up to 100m away). djust for highest flash rate. Lamp will glow steadily when alignment is OK. Continue with Method, step 4. 4 Disconnect lignment id temporary cable. Smoke larm test: Hold the test filter over the RX head. fter approximately 9 seconds the alarm relay will switch over, and the red alarm lamp will light. Remove the test filter, and the alarm will reset after approx. 4 seconds (unless in latching mode). To reset after a Fire alarm:- 1. Maybe automatically ( LRM switch open). 2. By the RESET/TEST switch. 3. By disconnecting the Controller supply for one second. 4. By taking to 0V the external reset terminal for one second. Fault larm test: The fault relay and the fault LED operate if the beam is totally blocked for approx 10 seconds. Clearing the beam clears the fault in approx. 4 seconds. Fault Indication Causes of FULT alarms The Ground level controller being in the RESET mode Infra-red beam being reduced in signal strength by more than 93% for more than 10 seconds. The GC reaching the last stage of compensation (see figure 3). Loss of power at Ground level Controller or at Transmitter. Misalignment resulting in a received low signal. 4

Connection and wiring diagram Figure 1 Good quality screened cable or MICC recommended for all wiring except control unit to P.S.U. earth must not be omitted screen of cable should terminate at glands. Do not use pigtails (ll junction box s should be metal) RELY WIRING S REQUIRED GLND GLND Rx SIGNL LEVEL LOW HIGH TEST/ RESET ON OFF SW5 R Y B +V RX SIGNL Rx 0V Rx FULT LED N/O N/C COM N/O N/C COM L R M F U L T - + TEST METER EXTERNL RESET LRM LTCH COMP 25% 35% 50% 1 S 2 U T P C P 2 L 4 Y V 100M + - B R GLND GLND - VE (0V) + VE (12-24 Vdc) MY BE SME P.S.U. S FOR CONTROL UNIT P.S.U. (12-24 Vdc) REMOTE RESET SWITCH OR RELY CLOSE MOMENTRILY TO RESET - VE + VE (0V) (12-24 Vdc) P.S.U. 5

L R M N/O N/C COM Figure 2 Typical single zone wiring + - LRM RESISTOR F U LT N/O N/C COM END OF LINE This diagram is for a single Fireray being the only device on a zone. The correct operation for Fire and Fault should always be checked connected to a typical panel. Relays are shown in quiescent condition. Contact Fire panel manufacturer for values of larm resistor and End of line (EOL). Figure 3 Fireray Selectable Options SWITCH SWITCH OPEN SWITCH CLOSED LRM LTCH COMP Fire relay will auto - reset * For BS 5839PT 5 leave open * t the last GC stage the Fireray will signal a Fault, but in the event of any further signal loss reducing the signal to the selected sensitivity level, a Fire alarm will be signalled. Fire relay will latch into Fire The Fireray will at the last GC gain stage signal a Fault. This will inhibit the Fire relay. 25% 35% * 50% 25% larm sensitivity selected 35% larm sensitivity selected 50% larm sensitivity selected NOTE: Select ONE alarm sensitivity level only. * Factory Default Settings. 6

Technical Data DC Supply (at the Detector) 11.5 to 28 volts Quiescent current <13m larm current <20m Operating temperature -20 to 55 C Tolerance to Beam misalignment at 35%: +/-1 ; Rx +/-4 Fire alarm thresholds 1.25dB (25%) 1.87dB (35%) 3.0dB (50%) Optical wavelength 880nM Max. Sizes: Control Unit 215x265x88mm; Heads with Brackets 83x115x135mm Weight: Control Unit 1060gms; Heads with Brackets 650gms Service/pplication Notes For full compliance with BS5839 Pt.5, use 25% and 35% thresholds. 50% threshold is recommended for hostile environments. Contains ESD sensitive devices Operating range 10 to 100 metres larm and Fault indication by voltage free change over relay contacts Receiver up to 100 metres cable run from Ground level Controller Transmitter and Controller may be powered from separate/common supply larm relay may be latching or non latching Finish White IP50 Parts List Transmitter with a clear lens Receiver with a dark lens Ground level controller 2 ngle brackets with 4 bolts and washers Test Card 6/00 Distributed by GE Interlogix www.aritech.com