Dissolved Oxygen Sensors

Similar documents
Quick Start Guide LIQ-QSG-Hx438, Rev A June Rosemount Hx438. Amperometric Steam Sterilizable Dissolved Oxygen Sensors

Retractable ph/orp Sensor

ENDURANCE Conductivity Sensors

Quick Start Guide LIQ-QSG-Hx338, Rev M July Rosemount Hx338. Steam Sterilizable and Autoclavable ph Sensor

High Pressure Conductivity Monitor

ExStik DO600 USER GUIDE. Dissolved Oxygen Meter. 99 Washington Street Melrose, MA Phone Toll Free

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Dual Input ph/orp Analyzer

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Dual Input Toroidal Analyzer

Dual Input ph/conductivity Analyzer

Free Chlorine Measuring System

Rosemount 372. HF Resistant ph sensor. Quick Start Guide LIQ-QSG-372 Rev. C June 2017

Mitocell: Instructions for Use

FOF INDUSTRIAL SATURATED STEAM STERILIZERS

PURSense Sanitary Flange Conductivity Sensors

Models TX-KE and TX-KP Toxic Gas Transmitters

Tracer DO PockeTester TM Code 1761

CT-7 Series Toxic Gas Transmitter Operator s Manual

245 Sanitary Flow-Through Toroidal Conductivity Sensor. Instruction Manual LIQ_MAN_245 Rev. D January 2014

CLARITY II TURBIDIMETER

RK/ RK Oxygen Detector Operator s Manual

UNITY 2 TM. Air Server Series 2 Installation Manual. Version September 2012

Rosemount 3200HP. ph Sensors. Instruction Manual LIQ-MAN-3200HP Rev. G April 2017

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER

Plate Coil Heat Exchangers

Durafet Non-Glass ph Electrodes Specifications

REVISION STATUS AMENDED PAGES. Initial release D. All

CR20-07 A-F-A-E-HQQE 3x400/ HZ

RK/ RK Carbon Monoxide Detector Operator s Manual

DR. E. HORN GmbH / Schoenaich, Germany

InTrac 797-M InTrac 797-P Instruction manual

CR A-F-A-E-HQQE 3x400/ HZ

PLATE HEAT EXCHANGERS. Operation and Maintenance Manual

Total Chlorine Analyzer

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Total Chlorine Analyzer

Installation/Service Manual. Slow Exhaust Autoclave

Model ROX Oxygen Analyzers

RK Carbon Monoxide Transmitter Operator s Manual

RK CO 2 Transmitter Operator s Manual

Model STX-PA Gas Monitor

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

OPERATOR'S MANUAL CD 400 / CD 500

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

Installation instructions Air drying unit for Bubble Sensor OTT CBS. English

If you are a beginner please feel free to contact us at any time regarding our electroplating course for beginners.

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

AVENGER HT THERMOSTAT RETROFIT INSTRUCTIONS

Tempest Hot Air Drying System. Installation Instructions. Ryobi 522/522HX/524/524HX/582/662. X /98 Rev-B

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

ASPIRE Laboratory Aspirator

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

PERFORM Operating Document

PORTABLE DEW POINT MONITOR

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

Table of Contents. English

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

RENZ FOR QUALITY PRODUCT CATALOGUE.

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

Rycroft Supapac Plate Heat Exchangers

Instruction Manual PN pH/rev.M February Model Solu Comp II. Dual Input ph Analyzer. Model Options and

INSTALLATION INSTRUCTIONS

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

HW-17 Record Cleaning Machine Setup and Instruction Manual

Installation Instructions / Warranty

Combustible Gas Sample-Draw Detector Operator s Manual

GROWMAX WATER Perfect Water for Plants and Gardens

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference.

RK-02 Multi Point Detector Operator s Manual

Ink Degasser for Pro-HP Bulk System Installation and Operation Manual

MILLENIUM MEMBRANE REPLACEMENT. Tools and Materials Required. Initial Preparation

Assembly of a Microbial Fuel Cell

Chemical resistant Vacuum Pumps

Powers TM Controls TH 188 Unit Mounted Thermostat

Heated Gas Sampling Probe PSG Basic

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

569, 570, 571, 572 Series

569, 570, 571, 572 Series

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

CLS-1450 Series Spinner Flask Instruction Manual

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

MODEL: O ELECTROCHEMICAL O2 DETECTOR (Used with ST1400 O2 Sensor) Part Number: MAN Rev. 0

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

PLEASE READ CAREFULLY THE INSTRUCTIONS BEFORE OPERATING

CORREX MP Anode with external voltage source. Installation & Operation Manual

Instruction Manual PN OZ/rev.K February Model SOLU COMP Ozone Analyzer

POWERS TM Controls HU 186 Room And Duct Hygrostats

Retrostat Kits for Johnson Controls D/N or H/C Thermostats

User Guide. Double Junction Reference Electrode

SuperKlean Washdown Products

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0


RK Hydrogen Sulfide Transmitter Operator s Manual

Yarway Narvik Steam Desuperheater Series 4300 TempLow

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

A B A B4

Transcription:

Instruction Sheet PN 51A-HxDO/rev.E July 2005 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit our website at www.emersonprocess.com/raihome/liquid/. 1.0 SPECIFICATIONS Temperature Range: -10 to 130 C (14 to 266 F) Maximum Pressure: 43 psig (400 kpa abs, 4 bar) Measurement Range: 0 to 20 ppm or 0 to 250% saturation, depending on instrument Wetted materials: Stainless Steel (type AISI-ASTM 316 Ti; DIN 1.4571) and Viton Process connections: Model Hx438: PG 13.5 thread Model Gx448: G 1-1/4 in. Thread Cable Connector: 4-pin Cable Compatibility: Standard 4-pin connector cable Compatible Analyzers: Rosemount Analytical Models 1054B DO, 1181 SO, 1055, 54eA, and 5081 Compatible Mounting Accessory: Model Hx438: Insertion or Retractable Mounting Assembly Model Gx448: None, mounts directly to the 61mm, G 1-1/4 in. weld-in socket (PN 9160504) WARNING Do not exceed temperature and pressure limitations of 130 C (266 F) and 72 psig (600 kpa abs, 6 bar). WARNING The electrolyte is highly alkaline. Protect your hands with gloves and use safety goggles. Avoid contact of the electrolyte with the skin, eyes, and mucous membranes. WARNING Before removing the sensor, be absolutely certain that the process pressure is reduced to 0 psig and the process temperature is lowered to a safe level!

MILLIMETER INCH MILLIMETER INCH MODEL Hx438 MODEL Gx448 2.0 INSTALLATION 2.1 UNPACKING AND INSPECTION Inspect the carton for damage. If damage is found, contact the carrier immediately. 2.2 SENSOR PREPARATION Sensor Preparation Guidelines: Carefully remove the plastic cap covering the sensing end of the sensor. Avoid causing a vacuum by gently and slowly twisting the sensor and cap until it is removed. Sensor is shipped dry, so electrolyte must be added prior to installation. Remove membrane cartridge. Add 2 ml of electrolyte to the membrane cartridge. Screw membrane cartridge back onto sensor body. Refer to Section 6.3 for additional details. Connection of the Sensor to the Analyzer/ Transmitter: 1. Wire the sensor to the analyzer/transmitter. See the wiring tables in Section 3.0. 2. Apply power to the analyzer/transmitter. After 2 hours, the sensor should be ready for calibration. The polarization time is necessary to get stable signals from the sensor. If the sensor is disconnected from the analyzer/transmitter for a short time, allow the sensor to stabilize for at least three times longer than the time is was disconnected. Time needed for stabilization should not exceed 2 hours. Mounting Guidelines: Mount the sensor using the PG 13.5 process thread (Model Hx438) or the G 1-1/4 inch thread (Model Gx448). NOTE Do not install the sensor upside down. 2

3.0 WIRING TABLE 1. Wiring to the Model 1054B DO-10 TB2 MEASUREMENT WIRE COLOR 1 Anode Brown 2 Ground N/C (see note) 3 Cathode Clear (see note) 4 Ground N/C 5 RTD IN Blue 6* Ground Yellow/green 7* RTD Sense Yellow 8 Earth Ground N/C TABLE 2. Wiring to the Model 1181 SO * Jumper 6 to 7 TB2 MEASUREMENT WIRE COLOR 1 RTD IN Blue 2 RTD Sense Yellow 3 Cathode Clear 4 Anode Brown Ground Yellow/green NOTE: Older cables did not have the braid separated from the clear cathode wire. Strip back the outer cover of the clear wire, find the braid, and connect the braid to TB2-2. Newer cables are pre-prepped. Connect clear to TB2-3 and braid to TB2-2. Hx438 and Gx448 steam-sterilizable dissolved oxygen sensors use a 22k NTC thermistor. The thermistor is wired to terminals 1 and 3 on TB5. Wiring Model Hx438 and Gx448 Sensors to Model 54eA Analyzer Wiring Model Hx438 and Gx448 Sensors to Model 5081-A Analyzer 3

Wiring Model Hx438 and Gx448 Sensors to Model 1055 Analyzer Wiring Model Hx438 and Gx448 Sensors to Model Xmt-A-HT-11 Analyzer (Pipe Mount)

Wiring Model Hx438 and Gx448 Sensors to Model Xmt-A-HT-10 Analyzer (Panel Mount) 4.0 MODEL Gx448 O-RING/FLANGE ADJUSTMENT The wetted o-ring placement can be adjusted to fit into any size weld-in socket. To adjust the o-ring, the flange under the threaded nut can move up/down the threaded shaft behind the o-ring. Adjustment procedure: 1. Locate the flange on the sensor (a). 2. Line up the notch in the threaded nut (b) with the hex screw in the flange. 3. Unscrew the hex nut with the hex key (c) which was provided with the sensor. 4. Twist the flange/nut combination up/down the threads (d) to a desired position. 5. Tighten the hex nut. 6. Install the sensor. b c d a

5.0 STERILIZATION Before autoclaving the sensor, cover the connector end of the sensor with a tight protective cap (PN 9160490). If the connector end gets wet despite the protective cap, dry the connector with pressurized air or a hair dryer. Drying prevents corrosion and damage to insulation. No protection is necessary when doing in-situ sterilization. 6.0 CALIBRATION AND MAINTENANCE Dismounting the sensor: Unscrew the free rotating PG 13.5 threaded connector and pull the sensor out of the process or mounting assembly. 6.1 CALIBRATION 1. Refer to the analyzer instruction manual for details. 2. Be sure the sensor has been operating for at least two hours before zeroing and calibrating. 3. Zero the sensor by placing it in nitrogen gas or in water containing about 5% sodium sulfite. If using nitrogen gas, be sure the membrane is dry. Once the reading is stable, zero the sensor. Refer to the analyzer instruction manual for details. 4. If sodium sulfite was used to zero the sensor, rinse the sensor with water and gently dry the membrane. Place the sensor in water-saturated air. Once the reading is stable, complete the full-scale calibration. Consult the analyzer instruction manual for details. 5. Calibration can also be done using air-saturated water or air-saturated medium. Although the sensor has an extremely low oxygen consumption rate, the liquid should be gently stirred during calibration. 6.2 SENSOR MAINTENANCE Periodically check sensor response in air and nitrogen. 1. Place the sensor in air. Allow the reading to become stable and note the value. Also note the sensor current, which should be between 40 and 80 na. 2. Place the sensor in nitrogen. A small plastic bag with a stream of nitrogen gas discharging into the bottom works well. 3. After one minute, the sensor current should be less than 2% of the value in air. For troubleshooting information, see Section 7.0. 6.3 REPLACING THE ELECTROLYTE AND THE MEMBRANE CARTRIDGE: Replace the membrane cartridge (membrane kit PN 9160487) as follows: 1. Hold the sensor vertically with the membrane pointing down. Carefully unscrew the membrane cartridge. 2. Carefully clean the tip of the glass body with a soft tissue, or clean with the polishing tool in one direction only. WARNING Do not polish in a circular motion. NOTE When replacing the membrane cartridge, do not touch the anode wire. 3. Check the small o-ring above the glass body. If it is damaged, replace it. 4. Use the plastic pipette in the membrane kit to add 2 ml of electrolyte solution to the new membrane cartridge. 5. Carefully screw the cartridge onto the sensor shaft. If too much electrolyte solution was used, the excess will be pushed out. Wash off the excess electrolyte with water.

7.0 TROUBLESHOOTING Below is a list of possible problems and solutions for Models Hx438 and Gx448 dissolved oxygen sensors. CURRENT IN AIR TOO HIGH SLUGGISH RESPONSE CURRENT IN AIR TOO LOW (>80 na at 25 C) (<40 na at 25 C) Problem Solution Problem Solution Problem Solution Very thin or defective Replace with new Contaminated, fouled, Clean membrane or Contaminated, fouled, Clean membrane or membrane membrane cartridge or dirty membrane replace with new or dirty membrane replace with new membrane cartridge membrane cartridge Defective glass body Return to Rosemount Loose membrane Replace with new Dried out electrolyte Loosen membrane or connector Analytical, Liquid Div. membrane cartridge film cartridge and tighten Poisoned anode Return to Rosemount Dried out electrolyte Loosen membrane Cathode contaminated Clean cathode with Analytical, Liquid Div. film cartridge and tighten by silver polishing paper Cathode contaminated Clean cathode with Cathode contaminated Clean cathode with Exhausted electrolyte Return to Rosemount by silver polishing paper by silver polishing paper Analytical, Liquid Div. Defective glass body Fill with new or connector electrolyte Membrane replacement kit, which includes electrolyte solution and polishing paper, is PN 9160487.

The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Specifications subject to change without notice. Credit Cards for U.S. Purchases Only. Emerson Process Management Liquid Division 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2005