RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

Similar documents
RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

M7100 Pressure Transducer

D5100 Industrial Differential Pressure Transducer

D5100 Industrial Differential Pressure Transducer

DP86 Constant Voltage with Fitting

MSP340 Pressure Transducer

MSP100 Pressure Transducer

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

M5200 Industrial Pressure Transducer

Heavy Duty Pressure Transducers Line Guide

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

U5300 Industrial Pressure Transducer

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

Druck DPI 705/DPI 705 IS Series

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

MSP100 Pressure Transducer

MSP300 Pressure Transducer

Gage Unamplified Noncompensated Flow-Through

M5800 Pressure Transducer with Rotatable Display

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

Heavy Duty Pressure Transducers

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Pressure Transducers Ultrahigh-Purity

U5700 Submersible Liquid Level Pressure Transducer

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Pos. Description Reference

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Configurable Pressure Transducer Model FP Issue 1. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

M5800 Pressure Transducer with Rotatable Display

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

U5600. Wireless Pressure Transducer SPECIFICATIONS

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

89BSD Digital Output

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Beck. The differential pressure transmitter for air

86BSD Digital Output

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

Automatic Isokinetic Sampler ST5

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Series DH3 Digihelic Differential Pressure Controller

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Interactive Catalog Replaces Catalog Pages

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

86BSD Digital Output

Series EDA Electronic Pressure Controller. Specifications - Installation and Operating Instructions

Gas cylinder scale Model GCS-1

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight

Sanitary Pressure Transmitter

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series DH3 Digihelic Differential Pressure Controller.

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Standard SPECIFICATIONS FEATURES APPLICATIONS

Absolute and Gage Pressure Transmitter

Specifications - Installation and Operating Instructions

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

SP900X Piezoresistive Monosilicon Pressure Transmitter

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

86BSD Digital Output

SHIMADEN DIGITAL INDICATORS

Rosemount 2090P Pulp and Paper Pressure Transmitter

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy 20 SLPM or 200 SLPM

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

CA 134. Piezoelectric accelerometer. IECEx NEPSI TIIS KGS. » From the Vibro-Meter product line» Vibration monitoring over a wide temperature

DMP305X-TST-S monosilicon gauge pressure transmitter

MS4525 SPECIFICATIONS

DMP305X-TST-H monosilicon gauge pressure transmitter

/8 DIN Level Indicator

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

HUM-M2 Humidity Sensor Module Description

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Installation Instructions for the

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

icountms Range Fluid Condition Monitoring Moisture Sensors

Interactive Catalog Replaces Catalog Pages

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

Product Training Module: Digital Pressure Sensors with CANopen Model DPS

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Temperature Measurement Transmitters for field mounting

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Datasheet: K-22 LO Sensor

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Transcription:

GE Oil & Gas RPS/DPS 8000 High Accuracy Resonant Pressure Sensor Since 1972, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial, aerospace, oil and gas, and research environments. Today, Druck is part of GE Oil & Gas and has continually worked to develop and improve on the performance of our pressure sensors to meet our customers requirements. The RPS/DPS 8000 is the first product to incorporate the exciting new TERPS technology. TERPS is a resonant silicon pressure sensor technology platform that provides an order of magnitude greater accuracy and stability than current pressure measurement technologies available. The new TERPS technology also extends the pressure range capability to high pressures and, by incorporating true pressure media isolation, greatly improves its suitability for use in harsh environments. In addition to providing the performance and packaging improvements available with TERPS, the RPS/DPS 8000 product line takes advantage of best practices to offer a wide range of pressure and electrical connections to enable a level of customization for your specific requirements never before available in the performance class of this sensor. Features: High Precision, ±0.01% FS over compensated temperature range High Stability, ±100 ppm FS/year Wide temperature range, up to -40 C to +125 C (-40 to 257 F) Media isolated construction, suitable for use in harsh environments Multiple Output configurations, RS-232, RS-485, USB 2.0,, (TTL) Wide selection of pressure & electrical connections to suit specific requirements The combination of the power of the TERPS technology and the quality, reliability and flexibility of the RPS/DPS 8000 Series offers a truly unique solution for high accuracy and high stability pressure measurement requirements.

Specifications Measurement Base Pressure Ranges 0 to 2 bar (0 to 30 psi) absolute 0 to 7 bar (0 to 100 psi) absolute 0 to 14 bar (0 to 200 psi) absolute 0 to 20 bar (0 to 300 psi) absolute 0 to 35 bar (0 to 500 psi) absolute 0 to 70 bar (0 to 1000 psi) absolute Note: Values in psi are approximate. The base range selected is the next range up from the requested calibrated range.units are converted to bar for selection; e.g., 30 psi = 2.07 bar. A 7 bar base pressure range will be selected. Calibrated Ranges Any zero-based range between 1 and 70 bar (14.5 to 1000 psi) can be specified. (Performance will be of the full scale of the base pressure range selected.) Barometric ranges are available in the RPS/DPS 8100 series. The lowest calibrated pressure is 35 mbar absolute. Overpressure 1.5X FS Sensor Failure Pressure 2.0X FS Pressure Containment Ranges to 7 bar (100 psi), 70 bar (1,000 psi) Ranges to 70 bar (1,000 psi), 200 bar (3,000 psi) Supply and Output Electronics Option Supply Voltage (V DC) Output 1 6 to 28 & Diode TTL (1,3,4) 3.5 Current Consumption (2) (ma) A 7 to 28 16.5 quiescent, 32 max B 9 to 28 16.5 quiescent, 32 max C 7.5 to 30 25 quiescent, 32 max U 4.8 to 5.2 USB 2.0 40 quiescent, 100 max 1. Jitter less than 20 ns 2. Full temparature range 3. Square wave pressure signal, 25 khz nominal, 4-10 khz span 4. Forward voltage diode, 0.5 to 0.7 V @ 25 C (77 F), typically 2 mv/ C nominal Response Time < 300 msec for pressure change from 10% to 90% FS Supply Response TTL: Accurate to specification within 500 ms of power up, over all operating temperatures ///USB: Accurate to specification within 10 min of power-up Electrical Protection /485//TTL:Connecting V supply and GND between any combinations of pins on the connector will not damage the unit Insulation 500 V DC Performance There are two levels of performance specification: standard and Improved Specifications include combined effects of non-linearity, hysteresis, repeatability and temperature errors over the compensated temperature range, and over the base pressure range of 35 mbar to the full scale pressure. Accuracy Code Precision A1- Standard 0.02% FS A2- Improved 0.01% FS For output, the above accuracies are achievable by using a polynomial curve fit algorithm and coefficient data supplied with sensor. Sensors are calibrated against standards traceable to UKAS operating to better than 100 ppm. Compensated Temperature Ranges: There are four compensated temperature ranges available: -10 to +50 C -40 to +85 C -40 to +125 C (TTL and CAN bus only) -55 to 125 C (TTL and CAN bus only) Temperature Effects All temperature effects are included in the accuracy statement. Long Term Stability Standard: ±0.02% FS/annum Improved: ±0.01% FS/annum Note: Unless otherwise specified, specifications are at the reference conditions of 25 C (77 F) ±5 C (±9 F) and 1 bar (14 psi). Orientation (g) Sensitivity Less than 0.2 mbar/g

Physical Specifications Storage Temperature Range As compensated temperature range. Operating Temperature Range As compensated temperature range. Pressure Media Fluids compatible with 316L stainless steel and Hastelloy C276 Please ensure that only the intended sealing face is used when mounting the sensor. Failure to comply with this requirement may affect performance or calibration accuracy. Male threaded pressure connectors must not be sealed or constrained against the face at the base of the thread. The forward cone or flat face should always be used, as indicated below. Ingress Protection See Electrical Connector section Vibration BS EN 60068-2-6 (2008) Sine sweeps 5 Hz to 2 khz, levels to 20g n BS EN 60068-2-64 random 10 Hz to 2kHz to 4gn RMS for 1 hour each axis Less than 0.02% FS effect at any time Shock DO-160E 9 (Figure 7.2) 20 g n 11 ms terminal saw-tooth profile Humidity MIL-STD-810D Method 507.2 Procedure III (Aggravated humidity environment, 65 C, 95% RH) Pressure Connector Available Options are: G1/4 Female G1/4 Male Flat G1/4 Male 60 Internal Cone G1/8 Male 60 Internal Cone 1/4 NPT Female 1/4 NPT Male 1/8 NPT Male M20 x 1.5 Male (3mm bore) M14 x 1.5 60 Internal Cone M12 x 1 Internal Cone 7/16-20 UNF Male 74 External Cone G1/2 Male G1/4 Quick Connect 1/2 NPT Male G1/4 Male Flat Long 7/16-20 UNF Female Depth Cone (G1/4 Female) 7/16-20 UNF Male Short Flat 3/8-24 UNJF Other pressure connectors may be available. Contact GE to discuss your requirement. Electrical Connector Code No. Description Max Operating Temp. Range C F IP Rating 0 No Connector -55 to +125-67 to +257-1 Cable Gland -40 to +80-40 to +176 65 2 Raychem Cable -55 to +125-67 to +257 65 3 Polyurethane Depth -40 to +80-40 to +176 68 4 Hytrel Depth -40 to +80-40 to +176 68 6 Bayonet MIL-C-26482-55 to +125-67 to +257 * C 1/2 NPT Conduit -40 to +80-40 to +176 67 G M12 X 15-pin -55 to +125-67 to +267 * H PTFE Cable (Orange) -55 to +125-67 to +267 54 M Micro USB socket -40 to +85-40 to +176 - * Hermetically sealed connectors with a maximum leak rate of 1 x 10-6 cc/s at 1 atmosphere. High IP rated mating connectors are available. Certifications CE Marked RoHS EMC Standards: BS EN 61000-6-1: 2007, Susceptibility - Light Industrial BS EN 61000-6-2: 2005, Susceptibility - Heavy Industrial BS EN 61000-6-3: 2007, Emissions - Light Industrial BS EN 61000-6-4: 2007, Emissions - Heavy Industrial BS EN 61326-1: 2013, Electrical Equipment for Measurement, Control and Laboratory Use - EMC requirements BS EN 61326-2-3:2013 Requirements for pressure transducers

Connection Details Flying Leads 0 RED SUPPLY +VE SUPPLY +VE SUPPLY +VE SUPPLY +VE YELLOW FREQ B Rx CAN Hi GREEN +VE TEMP A Tx CAN Lo BLUE GROUND GROUND GROUND SUPPLY -VE BLACK -VE TEMP - - CAN 0V ORANGE EEPROM - - - M12 G 1 SUPPLY +VE SUPPLY +VE SUPPLY +VE N/C 2 FREQ B Rx SUPPLY +VE 3 GROUND GROUND GROUND SUPPLY -VE /CAN 0V 4 +VE TEMP A Tx CAN HI 5 EEPROM - - CAN LO CABLE 1, 3, 4, C RED SUPPLY +VE SUPPLY +VE SUPPLY +VE SUPPLY +VE YELLOW FREQ B Rx CAN Hi BLUE +VE TEMP A Tx CAN Lo WHITE GROUND GROUND GROUND SUPPLY -VE BLACK -VE TEMP - - CAN 0V ORANGE EEPROM - - - SCREEN - - - - PTFE H RED SUPPLY +VE SUPPLY +VE SUPPLY +VE SUPPLY +VE YELLOW FREQ B Rx CAN Hi GREEN +VE TEMP A Tx CAN Lo BLUE GROUND GROUND GROUND SUPPLY -VE BLACK EEPROM - - - WHITE -VE TEMP - - CAN 0V SCREEN CASE CASE CASE CASE RAYCHEM 2 RED SUPPLY +VE SUPPLY +VE SUPPLY +VE SUPPLY +VE WHITE FREQ B Rx CAN Hi GREEN +VE TEMP A Tx CAN Lo BLUE GROUND GROUND GROUND SUPPLY -VE /CAN 0V BLACK EEPROM - - - SCREEN - - - - Micro-USB M 1 - - +5 V - 2 - - D-VE 3 - - D+VE 4 - - ID 5 - - GROUND MIL-C 6 A SUPPLY +VE SUPPLY +VE SUPPLY +VE SUPPLY +VE B FREQ B Rx CAN Hi C +VE TEMP A Tx CAN Lo D GROUND GROUND GROUND SUPPLY -VE E EEPROM - - - F -VE TEMP - - CAN 0V & Diode USB* 1 Maximum 10 10 1000 1000 2 Cable length (m) Note 1: Cable not provided with USB option.

Dimensional Drawings 8 (0.31) 81 (3.18) 4 (0.16) 24 (0.94) TYP DRUCK LTD. GR #### 8000 S/N ******* *** TO *** ba Supply: *** T Output: *** T Temp. Range: RPS800 PRESSU MALE PRESSURE CONNECTION MEDIUM PRESSURE CONSTRUCTION CRIMP & BOOT PU CABLE IP65 22 A/F (0.86) 84 (3.30) DRUCK LTD. GR #### 8000 S/N ******* *** TO *** ba Supply: *** T Output: *** T Temp. Range: RPS800 PRESSU 7 (0.27) 21 TYP (0.82) 22 A/F (0.86) LOW PRESSURE CONSTRUCTION RAYCHEM CABLE 14.5 (0.57) 42 (1.65) 32 (1.25) 60 (2.36) DEPTH CABLE FEMALE PRESSURE CONNECTION 22 A/F (0.86) CONDUIT WITH POLYURETHANE CABLE 7 (0.27) 15 TYP (0.53) 16 (0.62) 25.5 (1.00) 24 AWG 7/0.2 PTFE CABLE DEPTH CONE PRESSURE ADAPTOR 25 TYP 15.5 (0.61) MICRO USB SOCKET 17 (0.66) OPTIONAL WELDED PRESSURE ADAPTOR M12x1 5-PIN Notes: 1. All dimensions are nominal lengths and are subject to change. 2. All dimensions are in millimeters (inches). 3. Other pressure and electrical connectors may be available, please contact GE. 4. Low Pressure < 7 bar (100 psi) 5. Medium Pressure >7 bar (100 psi) and < 70 bar (1,000 psi)

Ordering Information (1) Select model code Main Product Variant RPS Resonant Pressure Sensor - Output (Note 1) DPS Digital Pressure Sensor - Digital Output (Note 1) Diameter, Material and Isolation 80 25mm Stainless Steel Oil isolated Electrical Connector 0 No Electrical Connector (Flying leads) 1 Polyurethane Cable IP65 2 Raychem Cable 3 Polyurethane Cable (Depth) IP68 4 Hytrel Cable (Depth) IP68 6 MIL-C-26482 (6-pin Shell Size 10) C 1/2 NPT Conduit with Polyurethane Cable (Non-Exd Only) G M12x1 5-Pin H Orange PTFE Cable M Micro USB socket (Note 4) Output Option (Note 6) 1 (TTL) A B C U USB 2.0 (Note 5) Compensated Temperature Range TA -10 to +50 C TB -40 to +85 C (Note 2) TC -40 to +125 C (Note 2 & 3) TD -55 to +125 C (Note 2 & 3) Accuracy A1 - Standard 0.02% A2 - Improved 0.01% Calibration CC Full Thermal Calibration Hazardous Area Approval H0 None Pressure Connector PA G1/4 Female PB G1/4 Male Flat PC G1/4 Male 60 internal Cone PD G1/8 Male 60 internal Cone PE 1/4 NPT Female PF 1/4 NPT Male PG 1/8 NPT Male PH M20x1.5 PJ M14x1.5 60 Internal Cone PK M12x1 Internal Cone PL 7/16-20 UNJF Male 74 degree external cone PN G1/2 Male PQ G1/4 Quick Connect PR 1/2 NPT Male PT G1/4 Male Flat Long PV 7/16-20 UNF Female) PW Depth Cone (G1/4 Female) PX 7/16-20 UNF Male Flat PY 3/8-24 UNJF RA 1/4 VCR Female RF 1/4 VCR Male RPS 80 4 1 - TA - A2 - CC - H0 - PA [Typical Model Code] Note 1: RPS variants require Output Option Code 1. DPS variants require Output Option Code A, B, C or U. Note 2: Pressure ranges 2 and 7 bar (30 and 100 psi) are not available at this temperature range. Note 3: Requires Output Option Code 1 or C and Electrical Connector Codes 0, 2, 6, G, or H. Note 4: Only available with USB output option. Note 5: Only available with micro USB socket connector.

Ordering Information (cont.) 2) State pressure range and units (e.g., 0 to 20 bar, 0 to 100 psi): Unit options are: Symbol bar mbar psi Pa hpa kpa MPa mmh 2 O cmh 2 O mh 2 O inh 2 O fth 2 O mmhg inhg kgf/cm 2 atm Torr Description bar millibar pounds/sq. inch Pascal hectopascal kilopascal megapascal mm water cm water metres water inches water feet water mm mercury inches mercury kg force/sq. cm atmosphere torr 3) State cable lengths and units e.g., 1 m cable, 3 ft cable (only required on certain electrical connectors): Note 6: Maximum Cable length: (1) - 10 m, (A) - 1000 m, (B) - 10 m, (C) - 1000 m. Integer values only, e.g. 1m (3 ft) cable. Minimum cable length is 1m (3 ft) if cable is supplied. Typical order examples: RPS 8011-TA-A1-CC-H0-PA, 0-7 bara, 5 m cable DPS 806A-TB-A2-CC-H0-PL, 0-1,000 psia

www.gemeasurement.com 920-519H 2016 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.