MHCFC4W Chilled/Hot Water Cassette Fan Coil

Similar documents
MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-120HE-03 Air-Cooled Chiller

CWA4 Chilled & Hot Water Fan Coil

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

Commercial High-Efficiency Condensing Units

FCC Fan-Coil Units High-Performance, Vertical

Product Specifications. Vertical Floor Consoles By First Co.

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Commercial High-Efficiency Condensing Units

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

catalog CDV Fan-Coil Units High-Performance, Vertical

Q-TEC QC-Series Chilled Water Air Conditioner

PAJ3. Product Specifications

SKYPAK II, 3 Ton Series, gives you a

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

MERIT Series R-410A - Upflow / Horizontal

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

SKYPAK II, 3 Ton Series, gives you a

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

MERIT Series R-410A - Upflow / Horizontal

Q-Tec TM QC-Series Chilled Water Air Conditioner

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

SKYPAK II Heating & Cooling Self Contained Packages

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Wall Mounted Air Conditioners with Gas Heat Models AVGA

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

SpaceKeeper Console (SKC)

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

SeasonMaker ThinLine Fan-coil Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

Concealed Ducted Split Series R-407C MBH

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Specifications and Performance S2H

SeasonMaker ThinLine Fan-coil Units

MERIT SERIES Up Flow / Horizontal

GUIDE SPECIFICATIONS AQUARIUS ii

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

VERTICAL FAN COIL UNITS

Incremental Comfort Conditioners

Bosch BVA Series Air Handler

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

C13-Series Engineering Guide

13 GEP A L P - 1 A

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Product Data. Features/Benefits. AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes

Submittal Data Performance Data Electrical Data

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

General Description. Operation

16 SEER TWO-STAGE AIR CONDITIONERS

WJH4 Product Specifications

AIR HANDLERS AIR HANDLERS

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL SPECIFICATIONS

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

RGE 13 A T - 1 A

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

technical guide Water-Cooled Self-Contained Units

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

13 SEER CONDENSING UNITS

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

SSL & SBS Engineering Guide

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Call us today! (800)

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Transcription:

MHCFC4W-16-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.1

HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 48,000 BTUH Multiaqua Model Number: MHCFC4W-16-01 Part 1 - General 1.01 System Description: Multiaqua Chilled Water Fan Coils are manufactured with galvanized steel and high impact molded polymers. 1.02 Quality Assurance: A. ETL Certified in accordance with U.L. Standard 95, latest version (U.S.A.). B. Manufactured in a facility registered to ISO 9002, Manufacturing Quality Standard. C. Fully load tested at the factory. D. Damage resistant packaging. 1.03 Delivery, Storage and Handling: A. Packaged and readied for shipment from the factory. B. Controls shall be capable of withstanding 150 F storage temperatures in the control compartment. Part 2 - Product 2.01 Equipment: A. General: 1. Unit shall be a factory assembled and tested water fan coil. 2. Unit shall be assembled with high quality. 3. Contained within the unit shall be all factory wiring, piping, and associated controls. B. Unit Cabinet and Cover: 1. Cabinet is constructed of galvanized sheet metal. 2. Cover composed of high impact polymers. 3. Internally and externally insulated to ensure quiet operation. C. Fan Motor and Blower Wheels: 1. Available in 208/230-1-50/60 VAC. 2. Fan motor shall be three speed, direct drive, and PSC type. 3. Fan motor shall be totally enclosed. 4. Fan motor shall be internal overload protected. 5. Radial blower wheel is dynamically balanced. D. Air Distribution: 1. Unit contains four manually adjustable discharge air louvers. E. Water Coil: 1. Manufactured with water coils containing copper tubing mechanically bonded to aluminum fins. 2. Coils are factory tested to 300 psig. 3. Coils are designed to accept an entering water temperature not to exceed 160 F 4. Pressure independent flow control required on both coils to not exceed max flow for each coil. Consult primary coil and secondary coil data for proper sizing F. Drain Pan: 1. Constructed of injected molded polystyrene. Rev. 1.1

G. Filters: 1. Unit shall contain a woven panel washable filter. H. Fresh Air: 1. Unit shall be able to receive up to 50% filtered fresh air. 2. Fresh air introduced shall be externally fan forced and externally controlled. Part 3 - Controls and Safeties 3.01 Controls: A. Fan coils are factory wired and tested. B. Unit includes a terminal block that is capable of incorporating a 24 vac, field supplied, hard wired thermostat. 3.02 Safeties: A. Fan coil contains a renewable fuse on the low voltage side of the transformer. B. Coils shall be designed to accept an entering water temperature not to exceed 160 F Part 4 - Operating Characteristics 4.01 Electrical Requirements A. Electrical line voltage connections shall be made at the factory supplied terminal block. B. Factory wiring shall be rated according to UL listing at the time of manufacturing. 4.02 Installation in high ambient/high humidity environments A. Cabinets are internally insulated from the factory. However, when these units are installed in high ambient/high humidity environments, additional external cabinet insulation may be required. Part 5- Definitions 5.01 Abbreviations: = Cubic Feet per Minute DB = Dry Bulb Temperature EWT = Entering Water Temperature = US Gallons Per Minute MBH = BTU X 1000 SC = Sensible Cooling TC = Total Cooling = Sensible + Latent WB = Wet Bulb Temperature = Water Pressure Drop in feet of head db = Decibel Level m = Meter In = Inches FP I= Fins per Inch OD = Outside Diameter ID = Inside Diameter MCA = Minimum Circuit Amps MOP = Maximum Over current Protection LBS = Pounds U.S. 5.02 Measurements A. All measurements with regard to length, width, and height shall be in inches. Rev. 1.1

MHCFC4W-16-01 Product Specifications Physical Data Model Number Overall Height (in) Overall Width* (in) Width** (in) Weight (lbs.) Cooling Rows FPI Heating Rows FPI Water Inlet/Outlet (in) Drain (in) MHCFC4W-16-01 18.1 44.9 38.5 125.7 3/14 1/14 ¾ FPT 1 barb *Units are Square. Overall width is the cover dimension. See IOM for drawing details. *Units are Square. Width is the cabinet dimension. See IOM for drawing details. Model Number Electrical Data*** Volts/ Phase/ Hertz Motor Watts Full Load Amps Fuse or HACR Circuit Breaker or Glass Fuse Per Circuit MCA MOP MHCFC4W-16-01 1200 208/230-1- 50/60 430 2.25 3 5 *All Electric Data Shown is at 60 hz Rev. 1.1

MHCFC4W-16-01 Chilled Water Performance Data MHCFC4W-16-01 COOLING CAPACITIES (Primary Coil) EWT AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 43569 6.0 SC 31224 13.9 TC 46682 7.0 SC 32541 1200* 42 18.4 TC 49063 8.0 SC 33596 23.6 TC 51765 9.5 SC 34760 32.3 *High Speed MHCFC4W-16-01 COOLING CAPACITIES (Primary Coil) EWT AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 39100 6.0 SC 29383 13.8 TC 41756 7.0 SC 30511 1200* 45 18.3 TC 43781 8.0 SC 31335 23.4 TC 46158 9.5 SC 32393 32.1 *High Speed Recommended minimum flow rate for the primary coil at > 2 fps is 3.5 gpm Recommended maximum flow rate for the primary coil at < 6 fps is 9.75 gpm Check www.multiaqua.com for the latest information. 5

MHCFC4W-16-01 Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered 50 1200 60 1200 70 1200 80 1200 (Primary Coil) WATER TEMPERATURE ( F) 6.0 12.8 38901 48613 58346 68095 77855 87622 97393 107165 7.0 16.9 40066 50076 60105 70150 80205 90269 100336 110406 8.0 21.6 40953 51188 61441 71710 81990 92277 102570 112864 9.5 29.5 41928 52407 62904 73415 83936 94464 104997 115533 (Primary Coil) WATER TEMPERATURE ( F) 6.0 12.7 29287 38985 48706 58444 68195 77954 87718 97485 7.0 16.9 30150 40146 50163 60197 70243 80298 90359 100424 8.0 21.5 30807 41028 51269 61528 71798 82077 92363 102652 9.5 29.4 31529 41995 52481 62981 73494 84014 94541 105071 (Primary Coil) WATER TEMPERATURE ( F) 6.0 12.7 19663 29349 39058 48787 58529 68281 78040 87802 7.0 16.8 20226 30208 40214 50238 60276 70325 80380 90439 8.0 21.4 20654 30862 41093 51341 61603 71875 82155 92439 9.5 29.3 21125 31579 42054 52545 63050 73564 84084 94610 (Primary Coil) WATER TEMPERATURE ( F) 6.0 12.6 10028 19702 29401 39119 48854 58599 68352 78109 7.0 16.7 10292 20262 30257 40272 50301 60342 70391 80445 8.0 21.4 10493 20689 30908 41147 51400 61665 71939 82217 9.5 29.2 10714 21156 31620 42103 52599 63106 73621 84141 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: MHCFC4W-16-01 HOT WATER CAPACITY (Primary Coil) AIR TEMPERATURE WATER TEMPERATURE 140F 6.0 68838 70F DB / 60F WB 7.0 70928 8.0 72519 9.5 74251 Check www.multiaqua.com for the latest information. 6

MHCFC4W-16-01 Chilled Water Performance Data MHCFC4W-16-01 COOLING CAPACITIES (Secondary Coil) EWT AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 23202 6.0 SC 16899 6.6 TC 24978 7.0 SC 17639 1200* 42 8.8 TC 26429 8.0 SC 18247 11.3 TC 27416 9.0 SC 18669 14.0 *High Speed MHCFC4W-16-01 COOLING CAPACITIES (Secondary Coil) EWT AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 20560 6.0 SC 15937 6.5 TC 22139 7.0 SC 16590 1200* 45 8.7 TC 23349 8.0 SC 17094 11.2 TC 24191 9.0 SC 17452 14.0 *High Speed Recommended minimum flow rate for the secondary coil at > 2 fps is 3.5 gpm Recommended maximum flow rate for the secondary coil at < 6 fps is 9.75 gpm Check www.multiaqua.com for the latest information. 7

MHCFC4W-16-01 Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered 50 1200 (Secondary Coil) WATER TEMPERATURE ( F) 6.0 6.1 23334 29079 34857 40662 46489 52333 58192 64061 7.0 8.1 23886 29766 35677 41612 47568 53540 59525 65520 8.0 10.4 24322 30307 36321 42358 48414 54485 60568 66661 9.0 13.0 24674 30744 36840 42959 49095 55246 61407 67578 60 1200 (Secondary Coil) WATER TEMPERATURE ( F) 6.0 6.1 17721 23444 29202 34989 40799 46629 52474 58332 7.0 8.1 18129 23988 29879 35798 41738 47696 52669 59653 8.0 10.4 18451 24416 30412 36433 42474 48532 54604 60686 9.0 13.0 18711 24762 30842 36945 43067 49206 55356 61517 70 1200 (Secondary Coil) WATER TEMPERATURE ( F) 6.0 6.1 12100 17801 23540 29309 35104 40920 46753 52599 7.0 8.1 12365 18203 24077 29979 35904 41849 47810 53784 8.0 10.4 12575 18520 24498 30504 36531 42577 48638 54710 9.0 13.0 12744 18776 24839 30928 37037 43163 49304 55455 80 1200 (Secondary Coil) WATER TEMPERATURE ( F) 6.0 6.1 6470 12151 17871 23624 29404 35206 41026 46862 7.0 8.1 6595 12413 18268 24154 30065 35997 41947 47910 8.0 10.4 6693 12619 18580 24570 30584 36618 42667 48730 9.0 12.9 6772 12786 18833 24907 31003 37117 43247 49389 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: MHCFC4W-16-01 HOT WATER CAPACITY (Secondary Coil) AIR TEMPERATURE WATER TEMPERATURE 140F 6.0 41085 70F DB / 60F WB 7.0 42022 8.0 42757 9.0 43349 Check www.multiaqua.com for the latest information. 8

MHCFC4W-16-01 Chilled Water Performance Data MHCFC4W-16-01 COOLING CAPACITIES (Both Coils) EWT AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 54051 10.0 SC 36349 9.2 TC 58502 12.5 SC 38327 1200* 42 14.0 TC 61739 15.0 SC 39754 19.8 TC 63999 17.5 SC 40773 26.4 *High Speed MHCFC4W-16-01 COOLING CAPACITIES (Both Coils) EWT AIR TEMPERATURE (F) ( F) 80 D.B. / 67 W.B. TC 48506 10.0 SC 34008 9.2 TC 52515 12.5 SC 35717 1200* 45 14.0 TC 55366 15.0 SC 36963 19.7 TC 57181 17.5 SC 37740 26.3 *High Speed Pressure independent flow control required on both coils to not exceed max flow for each coil Consult primary coil and secondary coil data for proper sizing Recommended minimum flow rate for both coils piped in parallel at > 2fps is 6.75 gpm Recommended minimum flow rate for both coils piped in parallel at < 6fps is 19.5 gpm Check www.multiaqua.com for the latest information. 9

MHCFC4W-16-01 Hot Water Performance Data This heating performance data is at dry bulb temperature indicated / wet bulb temperature not considered 50 1200 (Both Coil) WATER TEMPERATURE ( F) 10.0 8.6 44767 55997 67250 78521 89806 101101 112403 123710 12.5 13.1 45881 57384 68908 80448 92000 103561 115128 126700 15.0 18.4 46610 58291 69990 81702 93425 105156 116893 128633 17.5 24.5 47123 58928 70749 82581 94423 106273 118127 129985 60 1200 (Both Coil) WATER TEMPERATURE ( F) 10.0 8.6 33640 44853 56092 67350 78623 89909 101202 112502 12.5 13.0 64464 45953 57464 68993 80534 92087 103646 115211 15.0 18.3 65004 46672 58359 70062 81776 93499 105229 116964 17.5 24.5 65384 47177 58988 70812 82646 94488 106337 118190 70 1200 (Both Coil) WATER TEMPERATURE ( F) 10.0 8.6 22507 33704 44929 56175 67438 78715 90000 101293 12.5 13.0 23044 34519 46018 57535 69068 80612 92165 103724 15.0 18.3 23395 35051 46728 58421 70127 81843 93567 105297 17.5 24.4 23643 35425 47226 59042 70869 82705 94549 106397 80 1200 (Both Coil) WATER TEMPERATURE ( F) 10.0 8.5 11365 22547 33758 44992 56245 67512 78790 90075 12.5 13.0 11616 23077 34564 46071 57594 69130 80676 92229 15.0 18.3 11781 23424 35090 46774 58471 70180 81898 93622 17.5 24.4 11897 23668 35460 47267 59086 70916 82753 94596 Heating at ANSI/AHRI 440 with addendum 1, 6.3.2 Table 1 as follows: MHCFC4W-16-01 HOT WATER CAPACITY (Both Coils) AIR TEMPERATURE WATER TEMPERATURE 140F 10.0 79544 70F DB / 60F WB 12.5 81508 15.0 82782 17.5 83676

MHCFC4W-16-01 Data MODEL # Fan Speed MHCFC4W-16-01 L 775 M 860 H 1200 Wattage @ High Speed 430

MHCFC4W-16-01 Sound Data MODEL # MHCFC4W-16-01 Fan Speed db @ 1 m H 57 M 52 L 48

MHCFC4W-16-01 Wiring Diagram