Cloudwarm W i-fi Thermostat Comfort Anywhere Anytime MANUAL
Content Content 1.Packing List 2.Compatibility 3.RF Coupling 4.App Setup And Wi-Fi Configuration 5.Room Thermostat (Transmitter) 6.Receiver 7.Technical specification 3 4 4 5 13 17 20 *Thank you for choosing Cloudwarm thermostat. Please read this manual before installing! It is recommended that this device is installed by a qualified electrician. 2
1. Packing list Room thermostat 1 Receiver 1 Manual 1 Accessory package 1 Dowels 2 Fix screws 2 White sticky pads 2 Black sticky magnetic pads 3 USB cable 1; Adapter 1 Black sticky magnetic pads*3 White Sticky pads *2 Room Thermostat Manual USB cable Adapter 3
2. Compatibility Cloudwarm is compatible with most of heating systems, including: Conventional and condensing boilers Hydronic underfloor systems Combi, system and heat-only boliers Air source and ground source heat pumps (heating only) Zoned systems (one Smart Thermostat per room) 3. RF Coupling Long press light on receiver, green light is on and red light flicks regularly. Then long press MODE button to enter coupling state. Displaying ----- on transmitter is changed to wireless communication channel (Default channel is 10, 0-19 channels optional). RF icon on transmitter changed from flicking to constant on means coupling succeeded. 4
4. App Setup And Wi-Fi Configuration Step 1 Download App on your mobile device 1 Go to www.cloudwarm.com or below address to download Cloudwarm App onto your mobile device (smart phone, tablet, PC). It is available for ios (> Version 7.0), Android (>Version 2.3). The App is free. For Android operating system: http://www.cloudwarm.com/download/cwapp.php For ios operating system, go to App Store and search Cloudwarm. 2 Or scan below QR Code to download Step 2 Wi-Fi Configuration There are two ways optional to connect Cloudwarm to Wi-Fi: 1 WPS: press down WPS button on router, double press SET on transmitter. If there s no WPS button on router, please try 2 2 Use mobile device App to configure: Please make sure your mobile device is connected to Wi-Fi successfully. Initial Wi-Fi configuration has to be done under the condition that App installed device is connected to Wi-Fi. Once the initial connection is established, you can use 3G/4G network to control thermostat via App for daily uses. 5
1.Tap in top right corner of the interface; (For some Android operation system phones, icon may not appear in the top right corner, please tap the virtual menu key on the left of HOME button to Configure Wi-Fi.) 2.Tap Configure Wi-Fi, enter Wi-Fi setting and input Pass Word. PLEASE DO NOT tap Connect immediately; 3.Power on Cloudwarm, press and hold the SET button on right side of Cloudwarm for 5 seconds, until Wi-Fi LED blinks; 4. Tap Connect on App now, 10-20 seconds later, Wi-Fi LED light on constantly, connection established; 5. If unsuccessful, please follow below operations: 1 2 3 Check Wi-Fi on mobile device is on or not (the configuring process has to be done with Wi-Fi connected.) Check router, restart mobile device and follow the above steps again; If problem still exists, please go to www.cloudwarm.com and contact us. Step 3 Create an account Please make sure your mobile device is connected to Wi-Fi successfully. 1.Open Cloudwarm App, tap Register ; 2.Create an account. ID code is to be found at the back of transmitter or on package box; 3.Log in 6
Step 4 How to add more transmitters into one App 1. Tap Enter my room,tap and device information; 2. Tap Add device and input device name and ID. 7
Step 5 Settings. **To get local weather information shown on App ( top left corner), please input the city name where Cloudwarm is being installed at City line of device information. 1 1 Current ambient temperature 2 Target ambient temperature 3 Heating status 2 3 8
Manual mode: set the desired temperature by sliding your fingers on screen; Program mode: Tap program mode, enter programming interface, tap the screen, the below screen appears: 9
Set the desired temperature and time. Tap the program screen again to set temperatures and heating time for another period of time in the same day if needed. If an adjusted program to be copied to another day or set of days, go to top right corner Apply to and select the days desired the same operation to be repeated to. If changes to preset program needed, switch to Manual Mode, and set per needs. To go back to the original Program Mode, just switch it back. OFF Mode: When set to OFF Mode, Cloudwarm only heats when the room temperature drops below 5 to prevent frost damage. 10
Below underlined content is for Open Therm protocol supported boiler ONLY: Enter Control my boiler to see your boiler working state. Winter mode:display heating temperature and DHW (Domestic Hot Water) temperature. 1 Heating water temperature 2 Water pressure in boiler 3 Heating target temperature 4 DHW target temperature 5 Heating state 6 Boiler flame state 7 Boiler error code (definedby boiler manufacturer) 1 2 3 4 5 6 7 11
Summer mode: display DHW temperature;heating function is off. Off Mode:Anti-frost function. Go to top right corner, tap drop down menu, tap Technical to see boiler working data and error code (defined by boiler manufacturer). 12
5. Room Thermostat (Transmitter) When network is not available, thermostat still work per previous settings before network cut off, or you can use the buttons on thermostat to set. All LED light up for 3 seconds upon powering on, followed by version of built-in hardware. 1 2 3 4 5 6 7 13
1 MODE: press to select Manual Mode, Program Mode or Off Mode. 2 SET: press SET to see current time and current room temperature; press 5s to connect Wi-Fi. When time displayed on screen, rotate knob to set parameters Symbol/Icon Description/Function WIFI configuration (WPS):fast double press SET to enter Wi-Fi configuration, use router WPS function. Press set again and rotate the knob to set wireless communication channel (0-19) (default channel is channel 10) Press set again to set Hysteresis ON value(range 0-2 in 0.1 increment). For example, when target temp set at 25, hysteresis ON temp at 0.5, room temp at 24.5, transmitter sends heating request signal to boiler. Press set again to set Hysteresis OFF value (Range 0-2 in 0.1 increment). For example, when target temp at 25, hysteresis OFF temp at 0.5, room temp at 25.5, transmitter sends heating off signal to boiler. 14
Fast double press SET, displaying is changed from ---- to LOAD,reset completed. Press SET to exit current settings. 3 Knob: rotate to adjust temperature, valid only in Manual mode. 4 Room temperature sensor: detect current room temperature. 5 Reset button: reboot screen appears after reset button pressed. 6 & 7 Micro USB port: to supply power. Factory set defaults are: Hysteresis ON: 0.4 (boiler switch on at 0.4 below the target) Hysteresis OFF: 0.4 (boiler switch off at 0.4 above the target) Frost protection temperature: 5 Temperature calibration:long press SET and MODE simultaneously to enter calibration menu. When NO displayed on the screen, calibration can not be performed. Around 50 minutes after powering on, only when temperature icon is changed from small C to big C,calibration can be performed. 15
LED actions 1 2 6 3 4 5 1 2 Current room temperature Wi-fi connection state: Flicking Light on constantly Light off RF icon : Slow flicking Fast flicking On Establishing connection to server Connection to server established Connection to router failed RF communication error RF hardware error RF communication is normal 3 Manual mode : When set to Manual, Cloudwarm keeps the room temperature at the selected set point temperature. 4 Program mode : When set to Program, Cloudwarm runs the program preset via App on mobile devices or web use. 16
5 Off mode : When set to OFF, Cloudwarm only heats when the room temperature drops below 5 to prevent frost damage. Heating status : Flicking On Off Open Therm communication error Heating is on Heating is off 6. Receiver Red light Green light Off Flicking regularly Reasons Flame, OT is normal. Wireless communication is normal. Flicking regularly Off No flame. OT is normal.wireless communication is normal. 17
Off On Flame. OT is normal. Wireless communication is normal. On Off On Flicking regularly Flicking regularly On No flame. OT is normal.wireless communication is normal. Relay is open. OT is abnormal. Wireless communication is normal. Relay is open. OT is abnormal. Wireless communication is normal. Flicking irregularly Flicking regularly OT is normal. Wireless communication is abnormal Flicking regularly Flicking irregularly OT is normal. Wireless communication is abnormal Flicking irregularly On Off Flicking irregularly On Flicking irregularly Flicking irregularly Off OT is normal. Wireless communication is abnormal OT is normal. Wireless communication is abnormal Relay is closed. OT is abnormal. Wireless communication is abnormal Relay is open. OT is abnormal. Wireless communication is abnormal 18
1 Wires labeled OT from receiver to be connected with thermostat port of Open Therm protocol supported boiler; Wires labeled ON/OFF to be connected with thermostat port of On/Off type boiler. Use screw driver to connect the wires respectively. 2 Use black magnetic pad or white double side sticker in the accessory bag to stick receiver to a proper place depending on the wall surface quality, or use the screws to fix receiver onto wall. Schematic Diagram Wi-Fi router User Boiler WiFi RF Receiver USB cable AC/DC adaptor 19
7. Technical Specifications Basic specs Wi-Fi Power supply 100~240V AC,50~60HZ Power consumption 1.2W Relay load 0.5A 125V AC, 2A 30V DC Transmitter dimensions 86 X 86 X 35mm Receiver dimensions 86 X 86 X 20mm Housing material ABS+PC+Aluminum Temperature setting 0~35 Boiler control protocol Open Therm v2.1 Wi-Fi standard 802.11b/g/n Frequency 2.412GHz 2.484GHz Wireless frequency band 868MHZ(FSK) RF transmit range 100mintheopenair Safety mode WEP/WPA-PSK/WPA2-PSK Net protocol Ipv4, TCP Net type STA *The manufacturer reserves the right to change specification without prior notice. 20
*OT is short for Open Therm, a point-to-point communication system and connects boilers with room controllers. Open Therm assumes that the room controller is calculating a heating demand signal in the form of a water temperature Control Set point based on room temperature error which it needs to transmit to the boiler so that it can control the output of the boiler. The boiler in turn can transmit fault and system information to the room controller for display or diagnostics. ( Selected from Open Therm Protocol Specification v2.1 ) 21
Cloudwarm website App QR code for Android system Shenzhen Allied Control System Co,.Ltd. Address: 4-7th Floor,Bldg C,Junxing Industrial Area B,Heping,Fuyong,Bao An, Shenzhen, 518103, P.R.China. Tel: 86 755 81463548 Fax: 86 755 81463646 Company website: www.szacs.com Cloudwarm website: www.cloudwarm.com Cloudwarm is a registered trademark of Shenzhen Allied Control System Co,.Ltd.