DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Similar documents
Microwave/PIR Intrusion Detector with POPIT Interface ZX970

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

TriTech Ceiling Mount PIR/Microwave Detector DS9360. en Installation Guide

Commercial Series TriTech Motion Detector. Reference Guide

DS160/161 Request To Exit PIR sensors Installation Instructions

Commercial Series TriTech+ Motion Detector with Anti-mask

English. Italiano. Português. Françias. Español

DS160/DS161 Request To Exit PIR sensors Installation Instructions

DS860 Surface or Corner Mount TriTech PIR/Microwave Detector

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

Description. Optex Incorporated

D-Tect 2 GJD300 Quad PIR Movement Detector

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

Multiplex Eight Input Remote Modules

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Duct smoke housings, 4-wire D341/D341P and D342/D342P

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

FMR Installation Instructions. Addressable Fire System Controller

D285DH. Installation Instructions Photoelectric Duct Smoke Detector

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

DS7465i. Installation Instructions. Input/Output Module

Installation Instructions

Installation Instructions

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

Duct smoke housing, 2-wire D340/D340P

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Advanced DIGITAL Wired PIR Motion Detector

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

HX-80NRAM. High Mount Outdoor Detector

Photo Beam 5000/3000 Series Heater. en Installation Guide

Installation Instructions

Movement Detector GJD 300

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

Intrusion Outdoor Protection Perimeter

Ceiling PIR HS presence detector. Product Guide. Overview. Features

1125 PIR Motion Detector

MANUAL RESET ALARM RELEASE

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

F220-B6PS/M. Installation Guide. Addressable Detector Bases

D7052. Installation Instructions Multiplex Dual Input Module

D-TECT 3 IP. GJD260 IP Motion Detector

D343. Installation Instructions. Air Duct Smoke Housing

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

FR-A180 FR-A360. Occupancy detector. Use

180 Degree Ceiling Mounted Occupancy Sensors

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

DS7400Xi Addressable Control/ Communicator

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

1126 Series Ceiling Mount PIR Motion Detector

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

General Description. Industrial LuNAR DT AM Grade 3 Features

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Extended Range DUAL TEC Motion Sensor

D7053. Installation Instructions Multiplex Input/Output Module

DI601AM Outdoor PIR/AM Detector Installation Sheet

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

"Pegaso" wireless alarm system

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Addressable NAC Output Module D327A

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

D-TECT 2 IP. GJD230 IP Motion Detector

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

DD205RF/TX Detector Installation Sheet

Infrared Ceiling Mount Sensor

MANUAL RESET ALARM RELEASE

D1255RB/D1256RB/D1257RB

LS800S Intruder Alarm System. Engineering Manual

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Remote NAC Power Supply D7038

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

English. Series. Installation and Use Manual

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

Active Infrared Multi Beam Sensors

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

NetworX NX-548E Receiver Installation Instructions

D7044. Installation Instructions Multiplex Single Input Module

DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

Active Infrared Multi Beam Sensors. R Series

Transcription:

DS970-BEL EN Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

DS970-BEL Installation Instructions.0 Installation Considerations.0 Installation Considerations Not suitable for outdoor use. Never install the detector where the passive infrared (PIR) or microwave is in constant alarm (LED on). The LED is off when properly installed. Point away from outside traffic. Microwave energy passes through non-metallic walls. Point away from direct and indirect sunlight. Point away from glass or other objects that rapidly change temperature. Point away from rotating machines such as fans. Mount the detector on a solid and vibration-free surface. Secure drop-ceiling tiles if the area above the tiles is used as an air return for heating, ventilating, and air conditioning (HVAC) systems. Avoid mounting the detector within 0 cm of any fluorescent light fixtures..0 Mounting. Select a mounting location where an intruder is most likely to cross the coverage pattern (Figure ). Figure : Opening the DS970-BEL - Arrow - Recess between cover and base Figure : Cover Release Tabs Figure : Coverage Patterns - Release tabs (). Mount the detector between,7 m and 7, m above the floor.. To open the detector, locate the arrow on the detector s cover (Item in Figure ). Insert a flat head screwdriver in the recess between the cover and the base and turn (Item in Figure ). One side of the cover remains attached to the base of the detector. Optional: Remove the cover from the base. Press the two cover release tabs while lifting the cover from the base (Figure ). Ensure all wiring is unpowered before inserting wire.. Insert wiring into the rear of the base and through the center hole or wire entrance for surface mounting (refer to Items and in Figure on page ). Do not mount the detector to removable ceiling tiles unless a sandwich is made of the base, ceiling tile, and a back plate behind the tile. 5. Firmly mount the base using the mounting holes (refer to Items and in Figure on page ) and one of the following options: a. Depending on local regulations, mount the base directly on the surface using anchors, mollies, or wing nuts. b. Mount the detector on an electrical box. c. Connect the detector directly to short lengths of,7 cm conduit (short enough to avoid detector movement).. Use the curved mounting slots (refer to Item in Figure on page ) to rotate the detector up to 0 to achieve the needed coverage. Bosch Security Systems, Inc. / 998-0

DS970-BEL Installation Instructions.0 Wiring Figure : Mounting the Base.0 Wiring 5 Apply power only after all connections are made and inspected. Do not coil excess wiring inside detector. If necessary, connect the alarm and tamper contacts to a safe extra low voltage (SELV) circuit only. Refer to Figure for terminal identification. Figure : Terminals - + - Wire entrance or conduit base mounting hole - Wire entrance for surface mounting () - Straight mounting holes () - Curved mounting slots () 5 - Tamper post - Cable ties () 7. To use the ceiling tamper, loosen the tamper post (Item 5 in Figure ) by cutting the three tabs and mount the post to the ceiling using a 0, cm screw (Figure 5). Figure 5: Mounting the Post to the Ceiling - + NO C NC T T M 5 7 8 Terminals (-) and (+): Power limits are 9 VDC to 5 VDC. Use no smaller than 0,8 mm wire pair between the unit and power source. Terminals (NO), (C), and 5 (NC): Alarm relay contacts rated at 5 ma, 8 VDC maximum for DC resistive loads. Use Terminals and 5 for the normally-closed circuits. Do not use these terminals with capacitive or inductive loads. Terminals (T) and 7 (T): Normally-closed tamper contacts rated at 8 VDC, 5 ma. Terminal 8 (M): Memory Mode requires activating a supply voltage on Terminal 8. Refer to Section 8.0 Memory, Day Mode, Night Mode, and Remote Walk Test on page 5 for operating and wiring information. - Tab () - 0, cm screw (not included) 8. Attach the cover, if removed, and close it. 9. Use the cable ties (Item in Figure ) for strain relief. Bosch Security Systems, Inc. / 998-0

DS970-BEL Installation Instructions 5.0 LED Operation 5.0 LED Operation The DS970-BEL uses a tri-color LED to indicate alarm and supervision trouble conditions (Table ). Table : LED Steady red Steady yellow Steady green Flashing red LED Trouble Conditions Cause Unit alarm Microwave activation (Walk Test) PIR activation (Walk Test) Warm-up period after power up Refer to Table for the LED operations and to Table for the PIR sensitivity selections. Table : LED Operations Feature Setting Description LED Operates the tri-color LED. /OFF OFF If LED indication is not wanted Pins (refer after setup and the Walk Tests to Figure 7) are complete, place in the OFF position. Table : Setting HI* LOW** PIR Sensitivity Selection No jumper across the On or Off pins disables the LED. Description Use this setting if more sensitivity is needed. Recommended setting for most installations. Tolerates environmental extremes. * More sensitive to environmental changes that can cause false alarms. ** The detector is shipped in Low Sensitivity Mode. Refer to Figure 7 Figure 7: LED and OFF Pins and PIR Sensitivity Selection Pins.0 Walk Test : Ensure the LED jumper is set to (refer to Item Figure 7). : To avoid false alarm, set the microwave range to its minimum setting before starting the Walk Test (refer to Item in Figure 7). : After removing or replacing the cover, wait min for the detector s microwave to settle. Wait at least 5 sec between the walk testing procedures.. Wait at least min after power up to start the Walk Test. The red LED flashes until the detector stabilizes and no movement is detected for sec.. Watch the LED as you walk towards the edge of the pattern (refer to Figure on page ). The LED lights at the outside edge of the coverage range. Refer to Table for the LED indicators. Table : LED Green Yellow Red LED Lights Lights to Identify PIR pattern. the microwave pattern. Microwave and PIR Modes. Repeat Step from different directions until you adequately verify the coverage pattern.. If the required microwave coverage is not achieved, increase the microwave adjustment by slightly turning it clockwise (Item in Figure 7). 5. Wait min after adjusting the microwave range before continuing the Walk Test. Do not adjust the microwave range higher than needed. HI LOW OFF 7.0 Supervision Microwave: The complete circuit operation of this subsystem is checked approximately every h. Default: The detector defaults to PIR protection if the microwave subsystem fails. The detector indicates an alarm using the green LED only and by activating the alarm relay. MAX PIR Signal Gain - PIR sensitivity - Microwave - LED and OFF Bosch Security Systems, Inc. / 998-0

DS970-BEL Installation Instructions 8.0 Memory, Day Mode, Night Mode, and Remote Walk Test 8.0 Memory, Day Mode, Night Mode, and Remote Walk Test The Memory, Day Mode, Night Mode, and Remote Walk Test require a supply voltage on Terminal M to activate. The supply voltage must range from VDC to 8 VDC. Use the switch (Figure 8) or an external power supply (Figure 9). Figure 8: Sample Switch - + NO C NC T T M - + - Power - Memory Refer to Table for the desired action, control voltage, and LED jumper position. Table 5: Tests Desired Action Turn on Night Mode Turn off Night Mode/Display Stored Alarm To RESET Stored Alarm Turn on Remote Walk Test, if off Turn off Remote Walk Test, if on Control Voltage (Terminal M) (for more than 0 sec) OFF (from Night Mode) (for more than 5 sec to enter Night Mode) (for more than 5 sec but less than 0 sec) (for more than sec but less than 0 sec) LED Jumper OFF OFF Figure 9: External Power Supply - + - + NO C NC T T M - + 8. Anti-Vandal Screw After the cover is closed, secure the entire assembly using the supplied anti-vandal screw (Figure 0). Figure 0: Anti-vandal Screw - Control panel or external DC supply - Power - Memory Control Voltage: + VDC to +8 VDC = (Switch Closed); 0 VDC = OFF (Switch Open) Day Mode: Disables the alarm memory and allows the LED (if activated) to operate normally. Memory: Activated when the DS970-BEL is in the Night Mode. This allows the detector to store an alarm for display at a later time. Memory Mode requires the LED jumper to be in the position. Night Mode: Enables the alarm memory and disables the LED operation. Remote Walk Test: Remotely enables LED operation from Terminal M for walk testing. This feature is used when LED operation is disabled; the LED jumper in the OFF position. - Anti-vandal screw 8. Maintenance At least once each year, verify the detector s range and coverage. For continuous daily operation, instruct the end user to walk through the far end of the coverage pattern to verify alarm output before arming the system. Bosch Security Systems, Inc. / 998-0 5

MAX PIR Signal Gain DS970-BEL Installation Instructions 9.0 Coverage Pattern 9.0 Coverage Pattern Figure shows the typical coverage pattern for,7 m mounting height with optical adjustments set to "I." The maximum range is available between lens centers, not directly in front of the lens as might be expected. Figure : Coverage Areas 0 9 8 7 5 0 5 7 8 9 0 0 9 8 7 5 0 5 7 8 9 0 Meters - PIR Area - PIR Area - PIR Area - Microwave 9. Coverage Pattern Masking Mask undesired areas with the supplied set of masks. The masking kit contains two 0 masks and two 90 masks designed for the outside of the detector. Place the masks on the outside of the detector (Figure ). Figure : Masking Kit Figure : Coverage Pattern Masking - 0 mask - 90 mask Figure : PIR Zones - + NO C NC T T M - 0 mask - 90 mask Use the supplied masks to mask 90, 0, 80, 0 0, or 0. Figure shows two examples of coverage pattern masking. 0.0 Adjusting the Optical Module The DS970-BEL PIR zones are divided into three groups. You can independently adjust each group vertically for the best coverage within a room (Figure ). - Only two coverage patterns are shown for clarity. - PIR vertical adjustment knobs () Figure 5 on page 7 shows a sample of the chart located on the DS970-BEL. Use this chart to adjust optical modules based on the detector s mounting height. The range shown is the distance from the detector to the outside edge of the coverage pattern. In installations where targeted coverage is required for part of the area, the optical modules must be adjusted for the correct coverage. In Figure on page 7, the Bosch Security Systems, Inc. / 998-0

DS970-BEL Installation Instructions.0 Specifications Figure 5: Optical Module Adjustments AXIMUM RANGE FEET (METERS) 0 () 5 (,) 0 (,) 5 (7,) 0 (9,) 5 (0,7) 8 (,) C G I 0 () A D (,7) A MOUNTING HEIGHT FEET (METERS) (,) 5 (,) (,9) G D B A A 8 (5,5) 0 (,) I F E D C A A H A (,7) F E E C B A (7,) 5 (7,) I G G F E C B A A detector is mounted,7 m above the floor. The distance to one wall is, m and 0,7 m to the opposite wall. Using Figure 5 the optical module for the, m range was set to D and the optical module for the 0,7 m was set to I. Figure : Optical Module Adjustment Sample (, m) (0,7 m) (,7 m) For clarity, only two coverage patterns are shown..0 Specifications Table 5: Specifications Dimensions (H x D) Coverage Input Power Standby Power Alarm Relay Microwave Frequency Intended Use 8.9 cm x 7.8 cm Covers 0 by 5,8 m to m diameter when mounted on,7 m to 7, m high ceilings. Covers a m area when mounted at, m and covers a 5 m area when mounted at m. The pattern has 9 zones grouped into three sets of zones each. Each set covers / of the 0 coverage pattern and has a vertical adjustment for precise pattern alignment. 0 VDC to 5.0 VDC; 9 ma standby, 9 ma in alarm with LEDs enabled, and 9 ma maximum current. Only use a listed limited power source. No internal standby battery. 9 mah required for each hour of standby time needed. Standby power must be provided by a listed limited power source. Low and high settings. -operating Form C relay. Contacts rated 5 ma, 8 VDC, W maximum for DC resistive loads. The contacts transfer on alarm for a period of sec. Some countries require the relay to be connected to a SELV circuit only. Do not use with capacitive or inductive loads. Normally-closed (with cover in place) tamper switch. A wall (base) tamper is included. Contacts are rated at 8 VDC, 5 ma, W maximum. Some countries require the switch to be connected to a SELV circuit only. Connect the tamper circuit to a -hour protection circuit. Storage and operating range is -0 C to +9 C. BEL 0,55 GHz Belgium Bosch Security Systems, Inc. / 998-0 7

Bosch Security Systems, Inc. 0 Perinton Parkway Fairport, NY 50 www.boschsecurity.com Bosch Security Systems, Inc. 0