TECHNICAL SPECIFICATIONS BUTTONS

Similar documents
SALES SUPPORT DOCUMENT

SALES SUPPORT DOCUMENT

FIRERAY 5000 range USER GUIDE

Motorised Infrared Optical Beam Smoke Detector. User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Reflective Optical Beam Smoke Detector User Guide

Beam Detectors. The 6500 Series

Apollo Intelligent Auto Aligning Beam Detector. User Guide

PHOTOELECTRIC REFLECTIVE BEAM DETECTOR MODEL SRA-ET. Mounting Guidelines

Optical Beam Smoke Detector RK90R - RK90RS

Process Alarm Module RTA 421

Intelligent addressable fire alarm control panel

Sita200plus. 200detectors. Single loop analogue addressable System

XP95/Series 90 Test Set

Ionisation single-tube smoke detector for duct mounting

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

INSTALLATION AND MAINTENANCE INSTRUCTIONS NFXI-BEAM AND NFXI-BEAM-T REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500 AND 6500S REFLECTED TYPE PROJECTED BEAM SMOKE DETECTOR

Intelligent Addressable Fire Alarm System

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

2-Channel Smoke Detector SD - 110

The new detector from Rafiki

ALK-V PHOTOELECTRIC SMOKE SENSOR

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

A P P L I C A T I O N S G U I D E. Single-Ended Reflected Beam Smoke Detector

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

System 800 Addressable Fire Detection & Alarm System

Why Hart XL Aspirating Smoke Detection?

Touch Screen 1 loop Addressable Fire Alarm Panel

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

2-wire Passive Intelligent Loop (LED) Display Meter

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

your silent and loyal servant

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

this is by far the best beam money can buy

CODESEC FIRE ALARM SYSTEMS. security technologies

Air Check Ex O 2 Deficiency Monitor

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Generating Confidence

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Line Smoke Detector LRMX

2-wire Passive Intelligent Loop (LED) Display Meter

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

OPTICAL SMOKE DETECTOR Model: SPD-KADET

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

SEC 2000 Millenium Infrared Gas Detector

System 57. An advanced World of intelligent gas detection system management

Laser Distance Sensor Type M Analog-Output

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

mod. ERHSO712 mod. ERRHSO712 ENGLISH CONTROLLER mod. CSRLS MAINTENANCE ADDITIONAL CONTROLS

System 57. An advanced world of intelligent gas detection system management

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. The Intelligent Solution CONTENTS

Beam detector DBD-DL40 KBD-DL80 KBD-DL100

D296/D297. Application Guide. Projected Beam Smoke Detectors

Open-area Smoke Imaging Detection (OSID)

LF /2. Fire Alarm Control Panel. Features:

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

intelligent solutions

Air Check O 2 Sample Draw Monitor

HART XL High Sensitivity Smoke Detection

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

SecuriBeam Optical Beam Fire Detectors

HART XL High Sensitivity Smoke Detection

Table of Contents. 1. Mounting Tips... 2

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Danfoss gas detection units

SEC 5000 IREvolution Gas Detector

2000 Series Sensors Installation Guide

Universal Gas Detector

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Installation and Operation Manual

Air Check O 2 Sample Draw Monitor

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

Quadruple-beam photoelectric detector

Testing Emission Source ITES Operating Manual OM

Dräger Polytron 8000 Stationary gas detector (EC)

Instructions Protect ir Multispectrum IR Flame Detector X3300 9/

Added password for IP setup page : Password must be in IP format!

End To End Optical Beam Smoke Detector. Additional Information

Multiple Input and Output Modules

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4


Dräger Polytron 5700 IR Detection of flammable gases and vapours

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

Conventional Fire Detection

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

APPLICATION DATA SHEET

Sapphire Series TSVW & TWWS Chillwater Digital Thermostats

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

IDP-Zone-6 Six Zone Interface Module

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

Addressable Fire Alarm Control System 2100 series

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Transcription:

Maxlogic beam type smoke detector consists of 2 parts as a receiver and transmitter. Should be mounted as facing each other between the distance of 5-100 m. The detector works on the principle of light obscuration. In normal condition light produced by the transmitter unit falls on the photosensitive element. The transmitter unit is calibrated to a preset sensitivity level based on a percentage of total obscuration. It gives fault signal If this percentage of total obscuration is less than or equal to determined alarm level in 6-8 secs. It gives fault signal or fire alarm depends on the user choice. Detector gives fault alarm if there is more than 90% sudden obscuration of the light. PRODUCT FEATURES - 5-100 m operating distance - Protect against the fire around 1500 m 2 protection area - Compatible with EN 54-12 / EN 54-17 - Short circuit isolator featured model option - 3 sensitivity levels - 2 digit numerical screen for easy commissioning - LED indicators for operating, fault and fire conditions SDD-166 Rev.No:1 ML-2170, ML-1170, ML-1170.SCI Sales Support Document S/P 1/3

TECHNICAL SPECIFICATIONS Operating Environment Detection Principle Operating Distance Alarm Levels Indoor environments Light obscuration 5-100 m %25 / 1,25 db %35 / 1,87 db %45 / 2,6 db Alarm Response Time 6-8 sec. The Largest Angular Fault +/- 0,5 Operating Voltage Quiescence Current Alarm Current Operating Temperature Storage Temperature Max. Humidity Dimensions Weight Color 20V-30V DC Reciever:50 ma Transmitter:20 ma Reciever:60 ma (-10 C) - (+55 C) (-30 C) - (+60 C) %95 (non-condensing) 160 x 192 x 109 mm Receiver: 830 gr, Transmitter: 800 gr. White BUTTONS Cover Key Both receiver and transmitter have cover key. Cover closing information is sent by cover key in transmitter. And IR led starts to impact signal. Installation is started by cover closing in receiver. Menu Buttons Menu buttons are located on receiver. It provides to do menu settings. Up: It provides to pass to next feature and increase the value in feature. Down: It provides to pass to previous feature and reduce the value in feature. OK: It provides into the feature value tab and install the value. SDD-166 Rev.No:1 ML-2170, ML-1170, ML-1170.SCI Sales Support Document S/P 2/3

INDICATORS External Indicators Green LED: Both receiver and transmitter have this LED. It shows that detector is energized. Red LED: Only receiver has this. It shows fire alarm signal. Yellow LED: Both receiver and transmitter have this LED. It shows fault condition. In addition it shows that calibration is done. Internal Indicator 2x7 Segment Display MODELS ML-2170 ML-1170 ML-1170.SCI Maxlogic Conventional Beam Type Smoke Detector Maxlogic Intelligent Addressable Beam Type Smoke Detector Maxlogic Intelligent Addressable Beam Type Smoke Detector with Short Circuit Isolator ACCESSORIES AND OPTIONS ML-2171 ML-2172 ML-1171 ML-1171.SCI ML-1172 Maxlogic Conv. Beam Type Smoke Detector Receiver Maxlogic Conv. Beam Type Smoke Detector Transmitter Maxlogic Intelligent Addressable Beam Type Smoke Det. Receiver Maxlogic Intelligent Addressable Beam Type Smoke Det. Receiver with short circuit isolator Maxlogic Intelligent Addressable Beam Type Smoke Det. Transmitter SDD-166 Rev.No:1 ML-2170, ML-1170, ML-1170.SCI Sales Support Document S/P 3/3

Maxlogic beam type smoke detector consists of 2 parts as receiver and transmitter unit and reflector. Transmitter radiates IR with certain frequency and radiated IR is reflected by reflector, reflected IR is collected by receiver, this beam is filtered from other reflected beams. After that beam value is increased until the reference value that is determined in installation process. Measured beam in quiescence condition is compared with reference value. In case of fire, smoke value is increased in beam signal and beam intensity is reduced, receiver detects this intensity reduction. Fire alarm signal is sent and it gives fault signal. If this percentage of total obscuration is less than or equal to determined alarm level in 6-8 secs. It gives fault signal or fire alarm depends on the user choice. Detector gives fault alarm if there is more than 90% sudden obscuration of the light. PRODUCT FEATURES - With one reflector 5-35 m. Or with 4 reflector 35-50 m. operating distance - Protect against the fire around 525 m2 with one reflector - ML 1173.SCI - ML1174.SCI models are included the short circuit isolator features - Compatible with EN 54-12 / EN54-17 - 3 sensitivity levels - 2 digit numerical screen for easy commissioning - LED indicators for operating, fault and fire conditions. SDD-167 Rev.No:1 ML-2173, ML-1173, ML-1173.SCI Sales Support Document S/P 1/4

TECHNICAL SPECIFICATIONS Operating Environment Indoor environments Detection Principle Light obscuration Operating Distance 5-35 m. Alarm Levels Alarm Response Time The Largest Angular Fault Operating Voltage Quiescence Current Alarm Current Operating Temperature Storage Temperature Max. Humidity Dimensions Weight Color %25 / 1,25 db %35 / 1,87 db %45 / 2,6 db 6-8 sec. Receiver-Transmitter Module: +/- 0,5 Reflector: +/- 5 20V-30V DC 50 ma 60 ma (-10 C) - (+55 C) (-30 C) - (+60 C) %95 (non-condensing) Receiver-Transmitter Module:160 x 192 x 109 mm Reflector:120 x 100 x 8 mm Receiver-Transmitter Module:860 gr Reflector:70 gr White BUTTONS Cover Key Both receiver and transmitter have cover key. Installation is started by closing the cover. Detector gives fault alarm if the cover is open. Menu Buttons It provides to do menu settings. Up: It provides to pass to next feature and increase the value in feature. Down: It provides to pass to previous feature and reduce the value in feature. Ok: It provides into the feature value tab and install the value. SDD-167 Rev.No:1 ML-2173, ML-1173, ML-1173.SCI Sales Support Document S/P 2/4

INDICATORS External Indicators Green LED: Both receiver and transmitter have this LED. It shows that detector is energized. Red LED: It shows fire alarm signal. Yellow LED: It shows fault condition. In addition it shows that calibration is done. Internal Indicators 4x7 Segment Display MODELS ML-2173 ML-1173 ML-1173.SCI ML-0171 ML-0174 Maxlogic Conventional Reflective Beam Type Smoke Detector Maxlogic Intelligent Addressable Reflective Beam Type Smoke Detector Maxlogic Intelligent Addressable Reflective Beam Type Smoke Detector with Short Circuit Isolator Beam Type Smoke Detector Reflector, 1pcs. Beam Type Smoke Detector Reflector, 4 pcs. SDD-167 Rev.No:1 ML-2173, ML-1173, ML-1173.SCI Sales Support Document S/P 3/4

CONNECTION DIAGRAM ML-1173 / ML-1173.SCI Intelligent Addressable Reflective Beam Type Smoke Detector Connection Diagram ML-2173 Conventional Reflective Beam Type Smoke Detector Connection Diagram SDD-167 Rev.No:1 ML-2173, ML-1173, ML-1173.SCI Sales Support Document S/P 4/4