Listing Constructional Data Report (CDR)

Similar documents
Listing Constructional Data Report (CDR)

CLASSIFICATION Constructional Data Report (CDR)

RECOGNIZED COMPONENT Constructional Data Report (CDR)

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In

SECTION INTERIOR LIGHTING

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

Field Certification Certificate of Compliance

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

Honeywell Durafit LED Retrofit Kit

UL TEST REPORT AND PROCEDURE

AC/DC Power Supply and Battery Charger Installation and Maintenance

Jan05 Rev A EC

File S789 Project 04ME December 20, 2005 REPORT CONTROL UNIT (UOJZ) * * * * * * * * * * * * * * * * * * * * *

Public Safety DAS Annunciator Panel

Certificate of Compliance

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

CERTIFICATION BULLETIN

UL TEST REPORT AND PROCEDURE

Remote Relay Module (RRM)

SECTION SOLAR PHOTOVOLTAIC (PV) POWER GENERATION SYSTEM

Two Circuit Heavy Duty Burner Connector

Installation Instructions

Certificate of Compliance

SECTION AUTOMATIC TRANSFER SWITCHES

Annubar Flowmeter Series

Innovative Lighting R-Series Overhead LED Conversion Kits

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

APPROVAL REPORT. J.l. 3ZOA9.AX

1 General Description

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

IECEx Certificate of Conformity

IECEx Certificate of Conformity

FLASHLIGHT ANSI STANDARDS

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

CAUTION & SYMBOL DEFINITIONS:

SECTION SECURITY TESTING AND COMMISSIONING

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

CONTENTS AUTOMATIC TRANSFER SWITCHES

INITIAL ELECTRICAL ASSESSMENT REPORT (EAR)

Installation Instructions

Innovative Lighting R-Series Vertical Refrigeration

Schneider Electric Erie T155 Series

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

SAFETY INFORMATION AND WARNINGS

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

4100U City and Relay Cards Installation Instructions

Installation Instructions

Liquid Helium Level Instruments

MPT Electric Fire Pump Controller

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

SECTION AUTOMATIC TRANSFER SWITCHES

Refrigerating Appliance DOE Test Report

Installation Instructions

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Mar11 Rev C

Two-Channel Gas Controller

Rope Light Wiring. wdmlighting.com

Jun08 Rev A

Installation Guide for models:

UL TEST REPORT AND PROCEDURE

Certification Supplement Manual

Douglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7

Installation Instructions Wall Ovens

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

Installation Guide for models:

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

SECTION AUTOMATIC TRANSFER SWITCHES

Certificate of Compliance

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Certificate of Compliance

Installation Instructions

ECO1ZN3P, ECO2ZN4P ECO

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

CII FCAC-150 Series Relay

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

INTERNATIONAL STANDARD NORME INTERNATIONALE

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Model Number Structure

Declaration of Conformity

PQS Independent type-testing protocol

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

Under Cabinet Lighting

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Instruction Manual August sitrans CU 02

Transcription:

Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number HZ12070036-0 Original Portable Electric Luminaires ANSI/UL 153(12th Ed, rev. March 24, 21) Standard(s) Portable Luminaires CSA C22.2 No.12-1982 (R2008) Applicant Manufacturer Address No.5 Wan gong chi Road,Xiao dong Industrial Zone, Yuyao City, Ningbo, Address No.5 Wan gong chi Road,Xiao dong Industrial Zone, Yuyao City, Ningbo, Zhejiang Zhejiang Country China Country China Contact Richard Gan Contact Richard Gan Phone 0574-62502598 Phone 0574-62502598 FAX 0574-62502596 FAX 0574-62502596 Email richard.gan@euronb.com Email richard.gan@euronb.com Page 1 of 27

Page 2 of 27 2.0 Product Description Product Brand name Description Models Model Similarity Ratings Other Ratings Luminaire, Portable Smith Light The product covered by this report is portable luminaire with LED lighting and rechargeable battery. The battery shall be assembled with product and its charger shall be provided. IN2400L N/A Input: 12-24Vdc, 3,0A; Output: 12VDC, 20W NA

3.0 Product Photographs Photo 1 - Overview Page 3 of 27 Photo 2 - Overview

3.0 Product Photographs Photo 3 - Overview Page 4 of 27 Photo 4 - Overview

3.0 Product Photographs Photo 5 - Overview Page 5 of 27 Photo 6 - Construction

3.0 Product Photographs Photo 7 - Construction Page 6 of 27 Photo 8 - Construction

3.0 Product Photographs Photo 9 - Construction Page 7 of 27 02 Photo 10 - Construction 02

3.0 Product Photographs Photo 11 - Construction (Battery) Page 8 of 27 Photo 12 - Construction 02

3.0 Product Photographs Photo 13 - Construction Page 9 of 27 Photo 14 - Construction

3.0 Product Photographs Photo 15 - Construction (LED control circuit) Page 10 of 27 02 Photo 16 - Construction (LED control circuit)

3.0 Product Photographs Photo 17 - Construction Page 11 of 27 Photo 18 - Construction

3.0 Product Photographs Photo 19 - Construction Page 12 of 27 02 Photo 20 - Battery charger

Page 13 of 27 4.0 Critical Components Photo # Item no. 1 Name 1 1 Enclosure 5 1 Intenal enclosure 3 1 Transparent lampshade 6 1 14 1 9 1 12 1 Button 12 2 Switch Flexible cable between control gear and battery Internal wire between LED and control circuit Internal wire between battery and charger 19 1 Reflect board 19 2 PCB for LED array 18 1 Transparent cover for encasing heat sink 15 1 Connector 15 2 Terminal 16 1 10 2 10 1 Fuse 9 2 11 1 PCB for control circuit Heat shrinkable tube Battery 20 1 Charger Manufacturer/ trademark 2 Type / model 2 Technical data and securement means CHI MEI CORPORATION PA-757(+) ABS, yellow, 80 C, minimum 4,0mm thick (UL/E56070) CHI MEI CORPORATION PA-757(+) ABS, yellow, 80 C, minimum 4,0mm thick (UL/E56070) CHI MEI CORPORATION PC-110(+) PC, V-2, 105 C, minimum 1,5mm thick (UL/E56070) YUYAO XUANHUI ELECTRIC CO LTD YUYAO RIYUE WIRE & CABLE INDUSTRY CO LTD YUYAO RIYUE WIRE & CABLE INDUSTRY CO LTD DAILYWELL ELECTRONICS CO LTD SJT 15 15 Q13 300V, 105 C, 18AWG, with screw gland (UL/E322683) 600V, 80 C, 22AWG, Soldering (UL/E256446) 600V, 80 C, 22AWG, Soldering (UL/E256446) 120 V, 5A, 60 C (UL/E187490) LIGHT COUNTRY 125 V, 2A, 65 C R19A-0 CO LTD (UL/E104190) CHI MEI CORPORATION PA-757(+) ABS, yellow, 80 C, minimum 1,5mm thick (UL/E56070) HESHAN DONGLI ELECTRONIC TECHNOLOGIES CO LTD EPA V-0, 180 C, minimum 1,5mm thick (UL/E318223) CHI MEI CORPORATION PC-110(+) PC, V-2, 105 C, minimum 1,5mm thick (UL/E56070) FUYUAN ELECTRONIC CO FY1503000 LTD Input:100-240V~, 50/60Hz, 80VA output:15vdc, 3A (UL/E304160) Mark(s) of conformity 3 curus curus curus culus culus culus curus curus curus curus curus FUJIAN SHANYA SWITCH CO LTD FSE11 V-0, 105 C, Wire Range:12-28 AWG (UL/E305884) curus CIXI KEFA 250V, 8A, Wire ELECTRONICS KF126 (3) Range:14-26 AWG (UL/E306245) CO LTD curus KINGBOARD V-0, 105 C, minimum 1,8mm thick LAMINATES KB-2150G (UL/E123995) HOLDINGS LTD curus SHENZHEN WOER HEAT- SHRINKABLE RSFR-H 600V, 125 C (UL/E203950) curus MATERIAL CO LTD SHENZHEN LANSON ELECTRONICS 5D 125V, 5A (UL/E221465) curus CO LTD SHANGHAI FM/BB127, HONGBEI 12V7AH, 12V10AH, 12V18AH FM/BB1210, POWER SYSTEM (UL/MH46345) FM/BB1218 CO LTD curus curus

4.0 Critical Components Page 14 of 27 Photo # NOTES: Item no. 1 Name Manufacturer/ trademark 2 Type / model 2 Technical data and securement means 1) Not all item numbers are indicated (called out) in the photos, as their location is obvious. Mark(s) of conformity 3 2) Various means any type, from any manufacturer that complies with the "Technical data and securement means" and meets the "Mark(s) of conformity" can be used. 3) Indicates specific marks to be verified, which assures the agreed level of surveillance for the component. "NR" - indicates Unlisted and only visual examination is necessary. "See 5.0" indicates Unlisted components or assemblies to be evaluated periodically refer to section 5.0 for details.

5.0 Critical Unlisted CEC Components Page 15 of 27 No Unlisted CEC components are used in this report.

Page 16 of 27 6.0 Critical Features Recognized Component - A component part, which has been previously evaluated by an accredited certification body with restrictions and must be evaluated as part of the basic product considering the restrictions as specified by the Conditions of Acceptability. Listed Component - A component part, which has been previously Listed or Certified by an accredited Certification Organization with no restrictions and is used in the intended application within its ratings. Unlisted Component - A part that has not been previously evaluated to the appropriate designated component standard. It may also be a Listed or Recognized component that is being used outside of its evaluated Listing or component recognition. Critical Features/Components - An essential part, material, subassembly, system, software, or accessory of a product that has a direct bearing on the product s conformance to applicable requirements of the product standard. Construction Details - For specific construction details, reference should be made to the photographs and descriptions. All dimensions are approximate unless specified as exact or within a tolerance. In addition to the specific construction details described in this Report, the following general requirements also apply. 1. Spacing - In primary circuits, 6,4 mm minimum spacing are maintained through air and over surfaces of insulating material between current-carrying parts of opposite polarity and 9,5mm minimum between such current-carrying parts and dead-metal parts or low voltage isolated circuits. 2. Mechanical Assembly - Components such as switches, fuseholders, connectors, wiring terminals and display lamps are mounted and prevented from shifting or rotating by the use of lockwashers, starwashers, or other mounting format that prevents turning of the component. 3. Corrosion Protection - All ferrous metal parts are protected against corrosion by painting, plating or the equivalent. 4. Accessibility of Live Parts - All uninsulated live parts in primary circuitry are housed within a non-metallic enclosure constructed with no openings other than those specifically described in Sections 4 and 5. 5. Grounding - None 6. Polarized Connection - None 7. Internal Wiring - Internal wiring is routed away from sharp or moving parts. Internal wiring leads terminating in soldered connections are made mechanically secure prior to soldering. Recognized Component separable (quick disconnect) connectors of the positive detent type, closed loop connectors, or other types specifically described in the text of this report are also acceptable as internal wiring terminals. At points where internal wiring passes through metal walls or partitions, the wiring insulation is protected against abrasion or damage by plastic bushings or grommets. All wiring is minimum 22AWG with a minimum rating of 600V, 80 C. 8. Schematics - Refer to Illustration 1 for schematics requiring verification during Field Representative Inspection Audits. 9. Markings - The product is marked on as labeling system as described of Section as follows: <manufacturer's name, brand name, model number, date of manufacturer, electrical ratings>. 10. Cautionary Markings -The following are required: refer to Illustration 2 - Label for details 11. Installation, Operating and Safety Instructions - Instructions for installation and use of this product are provided by the manufacturer. Refer to Illustration 3- Instruction for details.

7.0 Illustrations Illustration 1 - LED control circuit Page 17 of 27

7.0 Illustrations Page 18 of 27

7.0 Illustrations Illustration 2 - Label Page 19 of 27 Model:IN2400L Lamp rating: Input :12-24VDC, 3,0A Output: 12VDC, 20W Date: 4005288 CONFORMS TO ANSI/UL STD 153 CERTIFIED TO CSA STD C22.2 No.12 Ningbo Euro Electrical Co.,Ltd No.5 Wan gong chi Road,Xiao dong Industrial Zone, Yuyao City, Ningbo, Zhejiang, China WARNING: --"RISK OF ELECTRIC SHOCK" or "RISQUE DE CHOC ÉLECTRIQUE" --"CAUTION RISK OF FIRE" or "ATTENTION RISQUE D INCENDIE" --"DISCONNECT POWER BEFORE SERVICING" or "COUPER L ALIMENTATION AVANT L ENTRETIEN"

7.0 Illustrations Illustration 3- Instruction Page 20 of 27

7.0 Illustrations Page 21 of 27 Contact Details No.5 Wan gong chi Road,Xiao dong Industrial Zone, Yuyao City, Ningbo, Zhejiang, China

7.0 Illustrations Page 22 of 27

Page 24 of 27 9.0 Correlation Page For Multiple Listings The following products, which are identical to those identified in this report except for model number and Listee name, are authorized to bear the ETL label under provisions of the Intertek Multiple Listing Program. BASIC LISTEE Address No.5 Wan gong chi Road,Xiao dong Industrial Zone, Yuyao City, Ningbo, Zhejiang Country China Product Luminaire, Portable MULTIPLE LISTEE 1 Address Country Brand Name ASSOCIATED MANUFACTURER Address Country None MULTIPLE LISTEE 1 MODELS BASIC LISTEE MODELS MULTIPLE LISTEE 2 Address Country Brand Name ASSOCIATED MANUFACTURER Address Country None MULTIPLE LISTEE 2 MODELS BASIC LISTEE MODELS MULTIPLE LISTEE 3 Address Country Brand Name ASSOCIATED MANUFACTURER Address Country None MULTIPLE LISTEE 3 MODELS BASIC LISTEE MODELS

Page 25 of 27 10.0 General Information The Applicant and Manufacturer have agreed to produce, test and label ETL Listed products in accordance with the requirements of this Report. The Manufacturer has also agreed to notify Intertek and to request authorization prior to using alternate parts, components or materials. COMPONENTS Components used shall be those itemized in this Intertek report covering the product, including any amendments LISTING MARK The ETL Listing mark applied to the products shall either be separable in form, such as labels purchased from Intertek, or on a product nameplate or other media only as specifically authorized by Intertek. Use of the mark is MANUFACTURING AND PRODUCTION TESTS Manufacturing and Production Tests shall be performed as required in this Report. FOLLOW-UP SERVICE Periodic unannounced audits of the manufacturing facility (and any locations authorized to apply the mark) shall be scheduled by Intertek. An audit report shall be issued after each visit. Special attention will be given to the following: 1. Conformance of the manufactured product to the descriptions in this Report. 2. Conformance of the use of the ETL mark with the requirements of this Report and the Certification Agreement. 3. Manufacturing changes. 4. Performance of specified Manufacturing and Production Tests. In the event that the Intertek representative identifies non-conformance(s) to any provision of this Report, the Applicant shall take one or more of the following actions: 1. Correct the non-conformance. 2. Remove the ETL Mark from non-conforming product. 3. Contact the issuing product safety evaluation center for instructions. 10.1 Evaluation of Unlisted Components Because Unlisted Components are uncontrolled, and they do not fall under a third party follow up program, Intertek may require these components to be tested and/or evaluated at least once annually, more often for certain components, as part of the independent certification process. The Unlisted Components in Section 5.0 require testing and/or evaluation as indicated. Note to Intertek Follow Up Inspector: The Component Evaluation Center, CEC, will notify you in writing when these components must be selected and sent to the CEC for re-evaluation Ship the samples to: Intertek Testing Services Shanghai Limited ETL Component Evaluation Center Building No. 86, 1198 Qinzhou Road (North) Shanghai 200233, China Attn: Ms. Dansy Xu Sample Disposition: Due to the destructive nature of the testing, all samples will be discarded at the conclusion of testing unless, the manufacturer specifically requests the return of the samples. The request for return must accompany the initial component shipment.

Page 26 of 27 11.0 Manufacturing and Production Tests The manufacturer agrees to conduct the following Manufacturing and Production Tests as specified: Required Tests Dielectric Voltage Withstand Test 11.1 Dielectric Voltage Withstand Test Method One hundred percent of production of the products covered by this Report shall be subjected to a routine production line dielectric withstand test. The test shall be conducted on products, which are fully assembled. Prior to applying the test potential, all switches, contactors, relays, etc., should be closed so that all primary circuits are energized by the test potential. If all primary circuits cannot be tested at one time, then separate applications of the test potential shall be made. The test voltage specified below shall be applied between primary circuits and accessible dead-metal parts. The test voltage may be gradually increased to the specified value but must be maintained at the specified value for one second or one minute as required. Test Equipment The test equipment shall incorporate a transformer with an essentially sinusoidal output, a means to indicate the applied test potential, and an audible and/or visual indicator of dielectric breakdown. The test equipment shall incorporate a voltmeter in the output circuit to indicate directly the applied test potential if the rated output of the test equipment is less than 500VA. If the rated output of the test equipment is 500VA or more, the applied test potential may be indicated by either: 1 - a voltmeter in the primary circuit; 2 - a selector switch marked to indicate the test potential; or 3 - a marking in a readily visible location to indicate the test potential for test equipment having a single test potential output. In cases 2 and 3, the test equipment shall include a lamp or other visual means to indicate that the test potential is present at the test equipment output. All test equipment shall be maintained in current calibration. Products Requiring Dielectric Voltage Withstand Test: Product Test Voltage Test Time All products covered by this Report. 1000V 60 s or 1200V 1 s

Page 27 of 27 12.0 Revision Summary The following changes are in compliance with the declaration of Section 8.1: Date/ Project Handler/ Proj # Site ID Reviewer Section Item Description of Change None