HEX390 Heat Exchanger

Similar documents
Dry-Matic with Digital Controller User Operating Instructions p2-5 Installation Instructions p6-9 Setup Instructions p10-15 Wiring Diagram

HEX390. Balanced Pressure Ventilation with Heat Recovery. for healthy indoor air

WHHR Midi & Midi Lite

IMPORTANT WARNINGS IMPORTANT SAFETY INSTRUCTIONS

Sentinel Kinetic MVHR RANGE

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Using the. Ducted Gas Central Heating Dual Cycle Refrigerated Air Conditioning Ducted Evaporative Air Conditioning. with your.

EH0533 Indoor Climate Control

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

EH0554 Indoor Climate Control

SmartVent. Digital Controller User Guide Manual. NZ s Home Ventilation Specialists

SmartVent. Keypad Controller User Guide Manual. NZ s Home Ventilation Specialists

Instruction Manual. Portable Air Conditioner

SAFETY AND INSTALLATION MANUAL MODEL 8100

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

USER S MANUAL HSC-14/18/24/24A

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

Instruction Guide: Thermostat Operation

Demand Duo Principle of Operation:

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

INSTALLATION & USER MANUAL

OPERATING INSTRUCTIONS. Drying cabinet DC 7774 DC Read the instructions before using the machine.

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Safety & Installation Instructions

Installer Guide. WARNING Important Safety Information. 1 Specifications

Safety & Installation Instructions

Synergy 405PLUS User Guide Manual

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

Thank you for choosing EnviroVent

INSTALLATION INSTRUCTIONS USER GUIDE

Installation and Operating Manual Drying Cabinet

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

Sentinel. Kinetic 200Z & 200ZH 300ZH. Installation & Commissioning. Model Stock Ref. N 200Z A 200ZH A 300ZH A

Installation and Maintenance

Drayton Digistat +3RF

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Safety & Installation Instructions

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions

Sentinel. Kinetic MVHR Range. Installation & Commissioning. Stock Ref. N PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

T600MEP-2 Programmable Economizer Thermostat

User s Manual

OPERATING INSTRUCTIONS

Owner s Manual. Using the Ducted Gas Central Heating Dual Cycle Refrigerated Air Conditioning Ducted Evaporative Air Conditioning.

AC500T, AC1000T, AC1500T, AC2000T

HEALTHY HOME SYSTEM CONTROL Plus Model: HHSC+

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

MODEL 1830/1850/1870 DEHUMIDIFIER APPLICATION QUICK START GUIDE

Please Read and Save These Instructions Safety Information

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Installation and Maintenance

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

Installer Guide. WARNING Important Safety Information. 1 Specifications

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Installation and Maintenance Instructions XPG144/145/146 Electric Fires

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

2200 and 2200L ALARM CONTROL SYSTEMS

Model: Available in : Sapphire Black and Glacier White. 1 Series

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Installation and Maintenance

HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18,

Model 1750A/ 1770A Dehumidifier Installation Instructions

READ CAREFULLY AND SAVE R3

Operating instructions Page 12

Mobile Air Conditioner Instruction Manual Model TC-N9KM

AdaptAire. Digital Control System. User Manual

INFRARED PANEL HEATER

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Installation, Operation & Maintenance Manual. Wash System

Product Manual SZ1009

READ AND SAVE THESE INSTRUCTIONS

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Installation instructions. and User guide. Designer wall glass canopy NZ AU. HC90CGX1 & HC60CGX1 models

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

The CAB & DAB Air Curtains

Model: Available in: Sapphire Black and Glacier White. 1 Series

Safety & Installation Instructions

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

CommStat 4 Controller

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

SAT- 3 Installation Setup Guide

Transcription:

HEX390 Heat Exchanger with Digital or Manual Controller Operating Instructions p2-4 Installation Instructions p5-8 Setup Instructions (digi) p9-12 Wiring Diagrams p13-14 Digital controller Manual controller Warm stale Air from house Warmed Fresh Air to house HEX Fresh Air from outside Exhaust Air to outside Heat is transferred to or from the incoming fresh air Cleaner, Warmer, Drier, Healthier Homes Congratulations on purchasing a HEX Energy Recovery Ventilation Unit HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015 1

90.3 343.0 263.0 C PLAN VIEW Operating Instructions 754.5 Return Air B from house Supply Air to house Fresh Air from outside Exhaust Air to outside This is Smooth-Air Products copyright and contains proprietary owned DESIGNED BY CHECKED BY APP A intellectual property rights and confidential data. All rights are strictly BEN MUNRO reserved. The information must not be used except for the agreed purpose. Unauthorised use, reproduction,or issue to any third party is not permitted without the prior written authority of Smooth-Air Products. This HEAT RECOVERY DESIGN document is to be returned to Smooth-Air Products when the agreed ALL DIMENSIONS +- 0.5mm UNLESS STATED purpose is fulfilled. PROJECT The unit is designed to recover heat from exhaust air, which ALL DIMENSIONS in IN mm turn SCALE: warms 1:3 (or cools) the fresh outside air. 6 Polymer cross flow FRONT VIEW Heat Recovery core 5 Fans 4 3 as Return Air filter Return Air Supply Air Exhaust Air Outside Air HEX HEX unit Supply Air filter Cleaning the unit s filters The internal filters are designed as secondary filters (there should be extended surface filters cleaning the air before reaching the unit). However, when unit filters are heavily soiled, wash or replace the filter material. To wash: use vacuum cleaner to remove excess dust, then wash in warm detergent treated water, keep filters flat or leave in frame to wash. 2 HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015

Manual Controller User Operating Instructions This unit has High / Medium / Low speeds which the homeowner can use to regulate the fresh air amount to suit the load. Typically: High where a number of people are living in the house and/or outside temperatures are moderate Medium less people in the house and/or colder outside temperatures Low mainly to keep air fresh in the home during extremely cold conditions. 3 speed switch 3 speed switch The 3 speed switch has four settings: 0 - Off 1 - Low 2 - Medium 3 - High Internal On/off thermostat (optional) For the manual controller, the optional thermostat can be set so the unit turns off if incoming air exceeds the set point (eg if thermostat is set to 30, the unit will turn off if the incoming fresh air is above 30ºC). Return Air filter Optional Internal On/Off Thermostat Fresh Air filter HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015 3

Digital Controller User Operating Instructions Congratulations on purchasing a HEX, Heat Recovery Ventilator with Digital Controller. This controller allows the user to adjust fan speed from high to low (fan limits are set in the commissioning menu to suit the size of house and system layout). The controller will automatically shut down in summer if outside air temperature (OS) exceeds 27 C and home is warm. There are a number of other features available at time of installation which will need to be discussed with the installer when the unit is commissioned (see Digital Controller Setup instructions p6-9). They include:- Optional supply air boost heater (when heater fitted) is controlled automatically when outside air temp (OS) is less than 12 C and home is cold. This is indicated by H with bar symbol in the unit display. Heat is controlled over a proportional band so that as OS gets colder, heater output increases to maximum. Operating Mode Status Mode button Optional winter off Heater option mode shuts down the fan not available for HEXdigi-NH automatically when outside temperature (OS) is less than 2 C. This is indicated by winter on the unit display. Outside Air Temp (OS) Inside Air Temp (IS) Increase Optional User System On/Off is available in User Menu, indicated by OFF on unit display. Optional Filter Timer measures the hours run by the fan and gives a flashing display when the filter needs to be cleaned/replaced. Clock function has battery back-up in the event of a power failure. Time can be set/adjusted by pressing mode and buttons together until Entering Menus then Set Clock appears. Time can then be adjusted using up & down buttons, once correct time is set, press mode to save new setting. Optional Attic Damper Kit. A diverting branch can be attached to divert the intake from the attic to the cooler outside air. Press mode and up arrow together. Entering menus will display, hold until Damper is on or Damper is off, then Change damper? ON or Change damper? OFF displays. Use the up arrow to change between the two settings. Time Decrease 4 HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015

Installation Instructions These units must be installed by a suitably qualified tradesperson. Electrical supply must be installed by a suitably qualified electrician as per the schematics on p13 (manual controller) and p14 & p15 (digital controller). 1. Plan layout, check required equipment: Supplied: HEX unit HEX attic box Triple rocker switch (inside attic box) Drain adaptor (inside HEX filter access door) Required: Primary extended surface filters External inlet and outlet grilles Internal supply and return grilles Duct Tape 3 and 4 core wire Drain condensate hose Balanced Pressure Ventilation Exhaust Air Supply Air Fresh Outside Air HEX390 Key Benefits Better Climate Control Reduced heating load Reduced air-conditioning load Fresh air Energy efficiency Reduces condensation Return Air 2. Mount Unit securely in ceiling space (eg use bungees to hang, or anti-vibration pad) where it can be readily connected to an electrical supply and is sufficiently high enough above the ceiling that a condensate drain can be run with a fall and P-trap to a suitable outlet (see drain installation over page). Once duct etc connected, unit needs to be level for drain to work properly. HEX hangers on top of unit HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015 5

3. Drain installation Drain adaptor (supplied inside HEX filter cover) is to be mounted to bottom of HEX unit. HEX unit must be level. Attach drain adaptor onto hole on base of unit Bottom of unit Condensate drain hose needs to be connected and shaped into a P trap, as in diagram: HEX Drain adaptor Drain Adaptor P trap in condensate drain hose 4. External inlet and exhaust - Mount Fresh Air inlet and Exhaust Air discharge away from each other, so that cross contamination is not possible, and as suits the home owner. 5. Internal return and supply - Mount supply air grilles as suits the homeowner, eg in the hallway and living areas. A hinged filter grille (eg PYHF400) can be used for return air. Mount return air grilles as suits the homeowner, eg one in the bathroom and one at the other end of the hall from supply grille. 6. Filters inside unit are secondary filters. Mount hinged filter grilles (eg PYHF400) or extended surface filters (eg FBP200) in ducting prior to unit for return air from house as well as fresh intake air. Return Air filter Supply Air Return Air Exhaust Air Outside Air HEX body Fresh Air filter 7. Duct Attach insulated ducting to all spigots and Y branches securely, ensuring an airtight seal by using tape. Duct runs must be stretched and as straight as possible, with long radius bends to minimise airflow resistance. Ducting must be supported separately from the HEX unit. Ducts must be insulated. 6 HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015

8. Mount Attic box Attic box can be mounted on the unit or anywhere in the attic. The hall controller - digital or manual 3 speed - will be shipped inside the attic box. Electrical supply must be installed by a suitably qualified tradesperson as per the schematics on pages 13, 14 & 15. Terminate separately the grey & brown wires from the HEX unit HEX Attic box 9. Thermostat for Digital Controller The thermostat for the digital controller is placed into incoming fresh air flow, through the pre-drilled hole, and fixed with the cable tie. It is then plugged into the attic box as pictured above. Cat5 cable to digital wall controller Temperature sensor wire plugs in here Temperature sensor mounted in fresh air inlet For digital controller, mount with pack glands downwards HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015 7

10a. Internal On/Off thermostat (optional) Digital Controller: If there is an internal On/Off thermostat, this should be disabled for digital controller, as the digital controller should control all airflows. 10b. Internal On/Off thermostat (optional) Manual Controller: The optional thermostat can be set so the unit turns off if incoming air exceeds the set point (eg if thermostat is set to 30, the unit will turn off if the incoming fresh air is above 30ºC). Return Air filter Optional Internal On/Off Thermostat Fresh Air filter 11. Next step Before commissioning the digital controller, consider the desired options for the situation & write them down eg on p12 8 HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015

Digital Controller Setup Instructions The Heat Recovery Digital Controller has a number of features available to customize the system to suit house size, layout and user preferences. The Setup menu is accessed by pressing the & buttons together for about 5 seconds until the display reads Setup Menu. The controller comes preset with default factory settings, these can be reinstated using menu item Factory Reset (number 14 on next pages). If the unit is not set up correctly to suit the house, performance may be reduced. There are a number of options which can be scrolled through by pressing the Mode button as below. If no button is pressed within 5 seconds the controller automatically reverts to normal operation. Once a button is pressed a backlight will operate and remain on for 20 seconds after the last keystroke. Press button to toggle between Y/N (Yes/No) or other options, then press Mode to advance through the menu. Options are on following pages. Display Key OS - Outside Air Temperature IS - Inside Air Temperature Winter - winter mode is on H - Heater is fitted Heater option not available for HEXdigi-NH Operating Mode Status HEX Mode [to scroll] Outside Air Temp (OS) Inside Air Temp (IS) Time Increase [Y/Ntoggle] Decrease Please note: if settings are changed from recommendations, performance of the unit may be reduced. Digital Controller setup instructions continued on next page HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015 9

Press Press up and down arrows together for 5 secs to get to Setup Menu Use up arrow to change, then mode together advance 5 through secs to menu get Setup Menu, Use Mode display button will to scroll then change to: through options 10 1. Heater Kit Y/N (default N). Heater option not available for HEXdigi-NH If N - heater options are removed from all menus. If Y - heater options are available in User menu - Heater On/Off for continuous or night heat (to times as set below). To set night heat option: press up arrow to select Y, then: press mode to display Heater Times >display then changes Heater ON 19:00 automatically to show the current settings (default: Heater OFF07:00) >display changes again to Change Times Y/N (default N). At this point, use then to select Y & change the times. Select desired Heater ON time in Hours:Mins using or Select desired Heater OFF time in Hours:Mins using or Heater Test Y/N (default N) change to Y, heater test will be performed. If there are any faults (including no heater connected), Heater Fault will display. (See menu item 4. Heat for possible Heater Fault causes.) To reset Heater Fault display, turn unit off. 2. Max (default 100%) Range is 10% to 100% adjustable in 10% increments using up & down arrows. For a large house set to a max of 100%. 3. Min (default 10%) Range is 10% to 100% adjustable in 10% increments using up & down arrows. For a large house set to a min of 50% 4. Heat (default 50%) Range is 10% to 100% adjustable in 10% increments using up & down arrows. Heater option not available for HEXdigi-NH Heat sets a minimum speed for the fan to ensure enough airflow for the heater to operate. There are many duct fan combinations, some more restrictive to airflow than others. Therefore, when setting up, the installer must check that the heater operates without Heater Fault flashing on the display. Heater Fault is triggered when the heater is operating but draws no current, this is most often due to insufficient airflow causing the airflow proving switch to cut off. If there is insufficient airflow, increase the Heat setting. Heater fault may also be caused by manual reset thermal cutouts which may need to be reset. Digital Controller setup instructions continued on next page HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015

5. Winter Mode Y/N (default N). Winter mode shuts the system down when the outside air temperature gets below eg 2 C. If Winter Mode is on, another menu item will appear to allow adjustment of actual shut down temp: Range -2 C to +5 C. 6. Filter Timer Y/N (default N) Controller counts hours run by the fan and when filter is due for a change the display flashes with Filter. If filter timer set Y, another menu appears allowing filter period adjustment (240 day) (range 150-240 days). A further menu item will appear at user level once filtered timer timed out, allowing timer to be reset once filters are cleaned or replaced. 7. I/Side Ref Temp (default 18 C) Range 16-24 C. This is the reference temperature for the inside of the house, used for: Heating when house temp (IS) is lower than 18 C (default) and outside temp (OS) is lower than 12 C (default) the heater will operate (if fitted). Summer when house temp (IS) is higher than 18 C (default) and outside temp (OS) is higher than 27 C (default) the unit will shut-down. 8. O/Side Ref Temp (default 12 C) Range 8-16 C. This is the reference temperature for the outside air, below which heater operates (if fitted). 9. O/Side Degree Offset (default 0 C) this allows unit to be calibrated in the unlikely event that outside air temperature reads too high or low (adjustment Heater option not available for HEXdigi-NH range -10 C to + 10 C). 10. I/Side Degree Offset (default 0 C) - As above. Heater option not available for HEXdigi-NH Heater option not available for HEXdigi-NH 11. Heat P/band (default 5 C) Range 1-7 C. Heat Proportional Band - When heater is fitted and conditions call for its operation, heater will start heating at 20% when OS (outside) drops to reference temp (default 12 C), and will operate at 100% when temperature has dropped by a further (default) 5 C (ie when OS is 7 C). 12. Summer Temp S/down (default 27 C) Range 25-35 C. When OS (outside temp) is greater than 27 C and IS (inside temp) is greater than 18 C, the system shuts down. 13. User Sys On/Off (default Off) - when On, user menu has option to turn system On/Off. 14. Factory Reset Y/N (default N). Yes defaults all menu items to factory default setting, these default settings are shown in brackets above. Optional Attic Damper Kit. A diverting branch can be attached to divert the intake from the cooler outside air to the attic. Press mode and up arrow together until Entering menus displays, hold until Damper is on or Damper is off displays. Change damper? ON or Change damper? OFF then displays. Use the up arrow to change between the two settings. Digital Controller setup instructions continued on next page HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015 11

Installer s recommended settings: 1. Heater Kit Y/N Heater option not available for HEXdigi-NH Heater ON time:... :... Heater OFF time:... :... 2. Max... % 3. Min... % 4. Heat... % Heater option not available for HEXdigi-NH 5. Winter Mode Y/N If Y, shut down temp:... C 6. Filter Timer Y/N If filter timer Y:... days 7. I/Side Ref Temp... C 8. O/Side Ref Temp... C 9. O/Side Degree Offset... C 10. I/Side Degree Offset... C 11. Heat P/band... C Heater option not available for HEXdigi-NH 12. Summer Temp S/down... C 13. User Sys On/Off 14. Factory Reset Y/N Optional attic damper kit installed Y/N Installer Details: 12 HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015

Wiring for manual 3speed switch The attic box also comes with a two core wire for use with the optional thermostat. HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015 13

Wiring for HEX digital controller Attic Controller Circuit Board Patch lead socket Heat Sensor Plug. Isolator Switch. Terminate grey & brown wires from the HEX unit separately See p7 for full image N P N P1 N P3 NO C NC 240VAC MOTOR HEAT Vent Terminate seperately Hall controller N P Cable for electrical supply is three core and pre-wired to the attic controller. N P Basic HEXbody wiring to attic box High Black P1 Medium Heat sensor Low N E HEX unit Brown Fan Grey Blue Grn/Yel Terminate Terminate N E Supplied cable for the fan unit is five core - wire to N & P1 Supplied cable for the duct heater for HT07 is three core. HT15 is four core - wire to earth, P3 & N. Note wiring connection details supplied with heater. Green Blue Brown Grey Grey (HT15D (for only) Only) For digital controller, mount attic box with pack glands downwards Optional Attic damper kit 1 2 3 1 Diverting Diverting 2 branch Branch motor 3 Motor If damper operates in "reverse" change CW<>CCW switch on motor body to correct. If damper oper For attic damper kit, ensure the heat change CW<> sensor is in duct, upstream of filter box. motor body to For heated units only Heater option not available for HEXdigi-NH (HT15 only) Heater (for HT07 &HT15) 14 HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015

Heater option not available for HEXdigi-NH Electrical Supply 230VAC by installer HEXdigi Attic box wiring diagram HEX Warranty 24 months manufacturing warranty from date of first retail purchase. This HEX product, when delivered to you in new condition from a HEX authorized dealer and used in normal conditions, will be free from any defects in manufacturing, materials and workmanship for the periods set out above ( Warranty Period ): Any faulty goods will be repaired or replaced via the HEX dealer. This warranty is for the manufactured product, it does not include installation or removal. WARRANTY RETURN Upon installation, please send to the manufacturer, c/o PO Box 8358, Christchurch (on request by the dealer). Purchaser: Address: Description: HEX390 Purchased from / Dealer: Dealer invoice number: Date of installation: Installed by: HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015 15

Operating Mode Status Mode [to scroll] Outside Air Temp (OS) Inside Air Temp (IS) Time Increase [Y/Ntoggle] Decrease Display Key OS - Outside Air Temperature IS - Inside Air Temperature Winter - Winter mode is on H - Heater is fitted Heater option not available for HEXdigi-NH Warm stale Air from house Warmed Fresh Air to house HEX Fresh Air from outside Exhaust Air to outside Heat is transferred to or from the incoming fresh air 16 HEX390man & HEX390digi - Operating Instructions, Installation Instructions, Wiring diagrams Sept 2015