SUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK

Similar documents
HEAT ONLY & COMBI BOILER

Quickheat 30 weather compensated boiler control

DOMESTIC HOT WATER Follow operational sequence

USERS GUIDE. LOGIC+ Combi 24, 30, 35

Logic+ Combi

prestige Control Application Supplement WARNING

prestige Indirect Water Heater (IDWH) Sensor Application Supplement WARNING

B-40/B-41 Modulating Temperature Controller

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

USER'S INFORMATION MANUAL

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

USERS GUIDE 24, 30. For installation guide see reverse of book

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

Psychrologix Controller W/ DHC

- Data Brochure Steam Control 279

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Energy-Efficient, Environmentally-Friendly Heating Solutions. Baxi Luna HT Residential Troubleshooting Guide

User Manual for model

USER'S INFORMATION MANUAL

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

BB3000 Series. Application. Features. Injection Pump Control General Instructions

Service manual. Riva Plus HE. M296.28SR/C System boiler. Wall hung, fanflue, roomsealed, high efficiency gas boiler

prestige Control Application Supplement - Type 5 MCBA WARNING

Heating Zone Control. How to apply RESOL MX controller

VSL II QUICK START GUIDE

Dual Mixing Application

USER'S INFORMATION MANUAL

Multifit. Installation & Commissioning Instructions

prestige Control Application Supplement - Type 5 MCBA WARNING

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Innovative Boiler & Heat Exchanger Concepts

Service manual. Riva Plus HE ERP. Wall hung, fanflue, roomsealed, high efficiency gas boiler. Leave this manual adjacent to the gas meter

heat interface units A BOILER WITHOUT A FLAME

Q - Series Boiler. Troubleshooting Manual

USER'S INFORMATION MANUAL

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

Control Panel Checklist

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

Cascade Sequencer. Control Installation and Operation Instructions. Infinite Energy Boiler Manual. Also read and follow: CS-IOM-1

USER'S INFORMATION MANUAL

TWINTEMP JR. HYDRONIC SYSTEM 2/2013

SERVICE MANUAL RIVA COMPACT M90E.24S M90E.28S M90E.32S Wall hung, fan flue, room sealed gas boiler

prestige Control Application Supplement - TriMax

- Application Boiler Control 260

DUO PLUS. Instruction manual

Service manual. Riva Plus HE. M296.28SM/C Combi boiler. Wall hung, fanflue, roomsealed, high efficiency gas boiler

Service manual RIVA COMPACT HE M96.24SM/C M96.28SM/C M96.32SM/C M96.24SR/C2 M96.28SR/C

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER

PROGRAMMABLE 7-DAY THERMOSTAT

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Service manual. Riva Plus HE ERP RIVA PLUS HE 24C ERP COMBI BOILER RIVA PLUS HE 28C ERP COMBI BOILER

prestige Control Application Supplement - ACVMax

Advanced Heating and Hot Water Systems

SERVICE MANUAL RIVA PLUS M90D.24S M90D.28S M90D.24SR M90D.28SR

prestige Control Application Supplement - TriMax

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

AQ252 Universal Injection/Mixing Boiler Reset Control Panels

Control Application. Supplement - ACVMax

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

WARNING WARNING. Temperature Control for Weil-McLain Aqua Plus Indirect Water Heater

SPECIFICATIONS - NIKE

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Raptor 320HB & 399HB Submittal Sheet

GB24 & GB30. User Manual

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

ETAF Series VDC Fan output LCD Fan Coil Thermostat

Service manual GARDA HE MK2. M96A.24SM/B Combi boiler M96A.28SM/B Combi boiler

HIGH OUTPUT. Skin design RANGE

HT V2 HT Split

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Service Manual Models:

A/23 MFFI - A/27 MFFI

PROGRAMMABLE 7-DAY RF THERMOSTAT

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

11.4 Component Assembly Diagrams and Parts Lists Case Assembly

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

ENVI Boiler Controller

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

User Manual for model

PEERLESS PUREFIRE Installation, Operation, and Maintenance Instructions Supplement - PF-460 NOTICE. Exhaust Vent/Air Intake Size

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

DIDACTIC MANUAL FAMILY: GROUP: MODELS: VERSIONS: PART NO.: AST 14 C 261/00. Wall-hung atmospheric boilers. Instantaneous type with Forced Draught

AQUAHEAT ADVANCE SPLIT

Heating and D.h.w. Controller RVL482 Basic Documentation

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

Vokèra OpenTherm 711 without external sensor connected

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler

Vokèra OpenTherm 711 with external sensor connected

After Sales Service Guide

Transcription:

This booklet will assist you in piping, wiring and setting the controls of the Riva Advance SV boiler to control an indirect fired hot water tank. All pipe tails for the connection to the tank are supplied with the boiler. If the tank will be controlled by a thermostat installed in the tank, no additional parts will be needed. If the boiler will sense and control the tank temperature, a remote temperature sensor must be purchased separate from the boiler. The part number for the sensor is BI1985 104. B C E D SUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK C E D RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK REMOVE CAP B TO EXPOSE PIPE CONNECTION. CONNECT PIPE TAIL E (DHW SUPPLY) TO PIPE CONNECTION CONNECT PIPE TAIL C (HEATING SUPPLY) TO PIPE CONNECTION CONNECT Y PIPE TAIL D (HEATING AND DHW RETURN)

HOT WATER OUTLET COLD WATER INLET TANK TT OR TEMP SENSOR C E D SUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK All piping should remain at least ¾ for loop to DHW tank No circulator is required or should be used for the DHW circuit Domestic Priority will automatically be given to the DHW tank by the boiler Boiler operation temperature during a domestic call will be set by the domestic knob on the Riva Advance control panel when a tank thermostat is used Tank temperature will be set by the domestic knob on the Riva Advance control panel when a tank temperature sensor is used

SETTING THE BOILER FOR USE WITH DHW TANK THERMOSTAT To connect the tank thermostat to the boiler, use electric wires with a diameter of at leaset 18 AWG. The electric wire used to connect the thermostat to the boiler may not be run in conduit with line voltage wires as they are low voltage. Remove the two screws shown in figure 12.21 and open the cover of the tank connection terminal board Connect terminals T1 and T2 on the terminal boar with the two electric wires as shown in Figure 12.22 Connect the same wire to the tank thermostat terminals. Programming The boiler is set at the factory in a heating only mode and can be combined with a DHW tank

Setting the tank with a thermostat Before powering the boiler, turn knobs 10 and 11 as shown in Figure 12.23 Power the boiler, the following will appear on the LCD display. To set the boiler to function with the thermostat, access programming by pressing the rest button 12 in figure 12.23 for 10 seconds, until parameter P01 appears on the LCD display; the following will appear on the LCD display (the sequence P01 alternates with ------). Press the reset button 12, in Figure 12.23 multiple times to scroll the various parameters, until reaching parameter P03, which is used to check the operation of the tank with a thermostat. The value displayed on the LCD is already set and must be 04.

Once checked, press the reset button 12 to move to parameter P04 and check the parameter is set to 04. SETTING THE BOILER FOR USE WITH EXTERNAL TANK SENSOR Remove all power from the boiler for 10 seconds. Power the boiler up, the following will appear on the LCD display. To set operation with the NTC probe, access programming and hold down the reset button 12 in Figure 12.23 for 10 seconds until parameter P01 appears on the LCD display; (the sequence P01 alternates with -- -- --). Press the reset button 12, in Figure 12.23 multiple times to scroll the various parameters, until reaching parameter P03, which is used to check the operation of the tank with an NTC probe.

The value that is displayed on the LCD is 04, turn the boiler knob 10 in Figure 12.23, to the minimum setting. The following table shows the correlation between the boiler knob setting 10 in Figure 12.23 and the displays shown on the LCD for parameter P03. Press the reset button 12 to access programming P04, the starting value shown on the LCD is 04, turn the boiler setting knob 10 in Figure 12.23 to the setting 4, the value shown on the LCD display is 04.

The following table shows the correlation between the boiler knob setting 10 in Figure 12.23 and the displays shown on the LCD for parameter P04. Once the pcb setting is complete, wire the tank sensor to terminals T1 and T2.