CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

Similar documents
SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

Wall-mounted compact indirect heat interface unit SATK30 series Safety instructions Dimensions Technical specifications Installation Commissioning

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.

T. +44 (0) E.

INSTALLATION AND SERVICING

ModuSat TP. Energy. Heat Interface Units

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

Convertible radiator valve for one-pipe systems, centre distance 35 mm

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

T. +44 (0) E.

IDEAL LOGIC HEAT INTERFACE UNITS (HIUs) PRODUCT GUIDE.

heat interface units A BOILER WITHOUT A FLAME

ModuSat TP. Energy. Heat Interface Units

Metering systems 0548EN April 2014

SATK 30 heat interface unit

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Contact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

Herz York Direct Heat Interface Unit

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

Ideasandformsinevolution

Sirius SAT. Working towards a cleaner future. Heat Boxes with Wireless Data Transmission. heating specialists

Systems for central heating

CRIMSON & CRIMSON MAX

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for vented systems.

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

ACCUMULATION OF EUROPEAN CLASS

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

DIRECT AND INDIRECT THERMAL ENERGY METERING

Stored Water District Heating Interface Units. Heat Interface Units

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

1 VICTRIX ZEUS Superior kw I features

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

SPECIFICATIONS - NIKE

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Composite under-boiler dirt separator with magnet DIRTMAG

HYDRAULIC SEPARATION. Product Range

R557R EN January 2012

Date: Project #: Engineer: Prepared By: Bid Date:

ENERGY TOP. Condensing boiler solutions

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Contact person Date Reference Page Daniel Månsson P07886B-rev2 1 (14) Energy and bioeconomy

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Samsung EHS Heat Pump Test

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Project Name: Location: Engineer: Contractor: I. GENERAL

- Data Brochure Universal Reset Module 422

LZT High efficiency air to water heat pumps with E.V.I. compressors

Thermostatic mixing valves with replaceable cartridge for centralized systems

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

HT V2 HT Split

Heat Interface Units for decentralised water heating in district heating systems

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating

Capri B Cast iron combination oil-fired boiler with water tank

Sirius FS. Working towards a cleaner future

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

Energy-Efficient, Environmentally-Friendly Heating Solutions. Baxi Luna HT Residential Troubleshooting Guide

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Solar heating systems

Trade Product List 2013 BIOMASS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

anti-condensation valve

System Design for efficiency using electronic, intelligent HIU s. Neil Parry CIBSE Accredited Heat Network Consultant

HERZ Differential Pressure Control Valve 4002

Transcription:

4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units SATK4 series regulate user heat requirements and DHW production through connection to the apartment storage. Since these are two-way systems with the specific feature of keeping the primary and secondary thermal medium strictly segregated, they are particularly suitable both for variable flow centralised systems with condensing boilers or remote district heating, and for systems characterised by high static pressure values. The connection to an individual storage (not supplied) allows a significant reduction in the power of the central heating system, the flow rates and the number of required boiler cut-ins. In the design stage, these conditions result in savings in the selection of boilers, pumps, diameters of the risers and in lower design temperatures, with a consequent reduction of heat losses. These benefits augment the intrinsic advantages of a normal variable flow system. Thanks to their compact design, the heat interface units can be mounted inside the dwelling, thus allowing the individual user to control both the production of domestic hot water and regulation of low or high temperature heating systems independently. Set point regulation or modulating temperature regulation with compensated set point Heating range - LOW temperature setting 4 C - MEDIUM/HIGH temperature setting 7 C Electronic control of all operating and diagnostic cycles, plus the facility to incorporate a heat meter that makes it possible to allocate costs fairly and in proportion to the actual usage of the heating services, makes SATK4 a complete, modern and highly performing heat interface unit. Dimensions Technical specifications Medium: water Maximum glycol percentage: % Maximum medium temperature: 8 C Maximum working pressure: - primary circuit: 6 bar - secondary circuit: bar Nominal heat exchanger capacity: 4 kw Maximum recommended primary circuit flow rate:, m /h Max. differential pressure on modulating valve Dp =, bar Electric supply: V (ac) ±% Hz Power consumption: - SATK4 W - SATK4HE 7 W Protection class: IP 4 Pump: - SATK4 UPS -6 - SATK4HE UPS -6 Pump by-pass setting:,4 bar Actuators: stepper 4 V Probes: NTC k Ω Safety relief valve setting: bar Safety thermostat: C ± Expansion vessel: - capacity 7 l - pre-charge value: bar Pressure switch: opening,4 bar - closing,8 bar /4" M /4" M /4" F 6 Materials Components: Fitting pipes: Frame: Protective shell cover: Heat exchanger: brass EN6 CW67N steel RAL 9 painted steel EPP braze welded stainless steel

SATK4 DHW production in storage SATK4HE DHW production in storage with high-efficiency pump Functional characteristics Heating range - LOW temperature setting 4 C - HIGH temperature setting 7 C Optional functions Heating cycle: - modulating temperature regulation with compensated set point Domestic water cycle: - DHW circuit absolute priority disabling Characteristic components. Frame. Expansion vessel. Electronic regulator 4. Electrical connections box. -way modulating valve (primary circuit) 6. Diverting valve 7. Heating flow temperature probe 8. Thermal safety thermostat 9. Secondary heating drain cock. Pressure gauge. Filling loop with backflow preventer. Safety relief valve. Pump 4. Pressure switch. Protective pump by-pass 6. Flow temperature compensation probe / secondary circuit strainer 7. Heat exchanger 8. Heat meter spacer template 9. Primary air vent cock. Primary circuit strainer/heat meter flow probe pocket. Primary circuit shut-off valves Hydraulic-functional diagram 6 7 8 TS 9 8 7 6 4 9

Operating cycles Domestic water cycle This cycle takes priority over the heating cycle. The domestic water cycle, when active, is indicated by the steady yellow DHW LED while the symbol is blinking. In response to a request for execution of the DHW cycle due to tripping of the storage thermostat, the regulator opens the modulating valve fully, switches the diverter valve towards the storage circuit, and starts the circulation pump without monitoring the temperature of the water transferred to the storage (ON-OFF control). The temperature of the domestic hot water held in the storage must be set using the storage thermostat (not supplied). When the storage temperature is reached the circulation pump is stopped and the modulating valve is closed. Heating cycle Set point regulation The active heating cycle is signalled by the yellow CH LED which comes on while the symbol is blinking. In response to a heating cycle request from the room thermostat the circulation pump is powered while the modulating valve is opened gradually until the set point temperature is reached. At the end of the heating cycle, the circulation pump comes to a stop and the modulating valve is closed. The heating cycle temperature set point can be set using trimmer P and shown on the display. Floor slab heating function (at LOW temperature setting) The function is activated by pressing and holding the RESET button for 8 seconds, and is signalled by the yellow CH LED, which switches on in flashing mode. This facilitates the laying of low temperature underfloor heating systems. This function can only be activated and executed if there are no faults. The function has a duration of 4 hours, and is carried out by simulating a request to run in heating mode starting from a set point of C and rising in regular intervals to a temperature of 4 C. Once the maximum set point has been reached, the function is executed in reverse following the same procedure (from the maximum to the minimum set point). This function has priority over heating and domestic hot water cycles, and can be suspended at any time by pressing and holding the RESET button for 8 seconds. 8 seconds Optional functions (to activate/deactivate the optional functions the electric power supply must always be turned off!). Heating cycle Modulating temperature regulation with compensated set point The function is enabled by setting dip switch to the OFF position. When the function is enabled, the flow temperature is modified according to the temperature detected by the compensation probe. This keeps the actual thermal output of the slab - and therefore the ambient thermal load - under control. The thermal response time of the system is thus minimised. DHW circuit absolute priority disabling Heating the storage cylinder may need relatively long times so the possible concurrent need to perform a heating cycle would be significantly delayed thus compromising the comfort level in the apartment. To avoid this problem the absolute priority assigned to the DHW cycle can be disabled by setting dip switch to ON. In this case, during periods of concurrent requests of the operating cycles the regulator apportion minutes long time intervals between the two cycles. The active cycle is signalled by flashing of the corresponding LED while the inactive cycle LED remains steady on. Trimmer P and the display are used to set and display the duration (from to 9 minutes) of the storage heating stage within the above indicated period (e.g. setting 6 minutes, this will be the duration of the DHW cycle while the heating cycle will proceed for 4 minutes). OFF 6 ON Safety and alarms Error codes associated with faults signalled by the lighting up of the FAULT LED are also shown on the display.

Hydraulic characteristics Heat exchanger - Primary circuit p (kpa) p (mm w.g.) Kv =,86 m /h, G (l/h) DHW function / heating function p (kpa) p (mm w.g.) Kv =,6 m /h, G (l/h) Head available at connections p (kpa) 6 speed p (mm w.g.) 6 4 4 G (l/h)

Completion codes 74.K CONTECA direct heat meter Direct heat meter for SATK series and/or meter box code 7894. Equipped with an 8-digit liquid crystal display. 4 V (ac) Hz - W centralized power supply. Complies with directive 4//EC (MI) 7894 Meter box Recess-mounting meter box with galvanized base and RAL 9 painted door for interior installation and finishing frame. Includes: - pair of /4 M manual shut-off valves, - pair of temperature pockets, - heat meter template, - fittings for DCW. Connection Size (mm) 7894 /4 x 8 x 744K 74K Connection / /4 Meas. type single nozzle single nozzle Q nom m /h,, 789 Hydraulic backplate Hydraulic backplate painted in RAL9, including bottom-up system connection. Includes: - frame, - steel pipes, - pair of /4 M manual shut-off valves. Depth: 6 mm. Q min l/h Connection Size (mm) 7894 7894 Wall mounting template Galvanized sheet metal meter plate. Includes: - pair of /4 M manual shut-off valves, - pair of temperature pockets, - heat meter mounting template, - fittings for DCW. /4 76 x 4 789 789 Differential pressure regulating valve. Brass body. Complete with capillary connection to the flow pipe. Max. working pressure: bar. Differential pressure fixed setting: kpa - kpa. Length of Ø mm capillary pipe:, m. 7 7 7 Domestic water function Domestic water meter kit consisting of: - BALLSTOP shut-off ball valve with check valve; - volumetric flow meter (MI); - shut-off ball valve with male terminal; - flushing pipe; - mounting bracket. DCW /4 with local reading DCW /4 with pulse output Complies with directive 4//EC (MI) 789* 7894** regulator kit Dp - kpa regulator kit Dp - kpa * kpa suitable for radiator-based heating system ** kpa suitable for underfloor heating and fan-coils 789 System flushing valve with manual by-pass control. System side connections: M. User side connections: /4 M. 789

SPECIFICATION SUMMARY SATK4 / SATK4HE Wall-mounted two-way indirect heat interface units with set-point regulation for low temperature ( 4 C) and medium/high temperature heating (-7 C) and domestic hot water production in storage cylinder, complete with: electronic regulator, thermal safety thermostat, primary circuit modulating valve, heating temperature probe, pump (SATK4: UPS -6, SATK4HE: UPS -6), with protective by-pass, fitted for heat meter installation, priority valve, plate heat exchanger, flow temperature compensation probe, electrical connections box, strainers on primary and secondary circuits, filling unit with backflow preventer, pressure relief valve ( bar), expansion vessel (7 l), pressure switch and pressure gauge. Dimensions W x H 6 x D 6 mm. Medium: water. Maximum glycol percentage: %. Maximum medium temperature: 8 C. Maximum working pressure: - primary circuit: 6 bar, secondary circuit: bar. Nominal heat exchanger capacity: 4 kw. Maximum recommended primary circuit flow rate:, m /h. Maximum differential pressure on valves:, bar. Electric supply: V (ac) ±% Hz. Power consumption: -SATK4: W, -SATK4HE: 7 W. Protection class: IP 4. Actuators: stepper 4 V. Probes: NTC kω. Materials: -components: brass EN 6 CW67N, - connection pipes: steel, -cover: grey EPP. We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice. Caleffi S.p.A. S.R. 9 n. 8 Fontaneto d Agogna (NO) Italy Tel. +9 849 Fax +9 867 info@caleffi.com www.caleffi.com Copyright 4 Caleffi