Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

Similar documents
WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

John Jay College of Criminal Justice HOT WORK PERMIT STANDARD OPERATING PROCEDURES

Title: Fire Prevention During Welding, Cutting and Other Hot Work Plan (formerly the Cutting & Welding Policy)

FIRE PREVENTION IN THE USE OF CUTTING OR WELDING PROCESSES

ADMINISTRATIVE SERVICES MANUAL

Bloomsburg University of Pennsylvania Hot Work Safety Program Effective Date: July 1, 2015

HOT WORK SAFETY PROGRAM:

Hot Work Program & Operational Guidelines. Environmental Health, Safety and Emergency Management (828)

Chapter 12 HOT WORK OPERATIONS. Purpose:

Office of Risk Management EHS Hot Works Program

HOT WORK PERMIT PROCEDURES

HOT WORK OPERATIONS March 23, 2018

Safe Operating Procedure

POLICY STATEMENT: Policy Number: Section 600 Physical Plant. Date Adopted: May 7, Date(s) Revised: September 4, 2012

1.2 To ensure the safety of all persons working in or occupying a building where a hot work operation is performed.

Chapter 18 Welding Table of Contents

HeatExchangerSpares.com Ltd HRS Heat Exchangers Ltd HRS Hevac Ltd HRS Hevac Engineering Ltd HRS International Ltd HRS Investments Ltd

Safety & Security Services Services de Sûreté et Sécurité. Hot Work Protocol

Progressive Safety Services LLC 2

This policy applies to all Hot Work jobs performed on the Calhoun mill property by AbitibiAbitibiBowater employees.

EXAMPLE FIRE PREVENTION AND PROTECTION PLAN WORKSHEET

UC Irvine Environmental Health & Safety TITLE: FIRE WATCH AND OUT OF SERVICE NOTIFICATION

DUQUESNE UNIVERSITY. Fire Protection System Impairment Program (Red etag Permit)

Date Issued: December 14, 2017 Revision: 2.1

Fire Prevention Plan for Alter Hall 3743 Ledgewood Drive

Procedure DESCRIPTION/OVERVIEW

Combustibles - Gases, liquids or solid materials that will ignite in the continued presence of an ignition source.

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Ls Vegas, NV (702) FAX (702)

Fire Prevention Plan

Xavier Field Office Fire Prevention Plan. for. Xavier Field Office Dana Avenue

Fire Prevention Plan for Campus Services Building 1630 Musketeer Drive

Fire Prevention Plan for St. Barbara Hall 3904 Winding Way

Fire Prevention Plan

Fire Prevention Plan for Residence Life 1625 Musketeer Drive

Hot Work Policy and Procedures

INTRODUCTION... 1 OBJECTIVES... 1 RESPONSIBILITIES...

Demolition Permit Application (Please print and complete ENTIRE form)

Fire Prevention Plan for Bellarmine Parish Center 3832 Ledgewood Avenue

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

General Safety Training

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

UNIVERSITY OF TOLEDO

polyurethane & polyisocyanurate foam Six Steps for

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

Risk Management Services

General Safety Training

Impairments to Fire Protection Equipment

Contractor Safety. Workplace Safety & Environmental Division

Renovation Program. Renovation Program GENERAL

Fire Prevention Plan for

Phase 2 Security Response

OUTLINE FOR FIRE PREVENTION ACTIVITY

Fire Prevention STANDARD. LME-12: Uen Rev A

Fire Prevention Plan Program

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

Fire Prevention Plan for Cintas Center 1624 Musketeer Drive

FIRE SAFETY AND PREVENTION POLICY

Safety Policy and Procedure

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Fire Prevention Plan Program Prepared by: Allied Insurance Brokers, Inc.

Hot Work Permit. Can this job be avoided? Is there a safer alternative? Permit No.:

Fire Prevention Plan for Alumni Center 1507 Dana Avenue

2010 FIRE CODE OF NEW YORK STATE

First Revision No. 3-NFPA 51B-2016 [ New Section after 1.5 ] Submitter Information Verification. Committee Statement 11/18/2016 2:25 PM

PROSPECT COLLEGE HEALTH AND SAFETY PLANS FIRE PREVENTION PLAN

Fire Prevention Plan for Xavier Armory 3908 Winding Way

JEFFERSON COUNTY PUBLIC SCHOOLS FIRE WATCH PROGRAM

FIRE PREVENTION PLAN EMERGENCY ACTION

Fire Watch Program. Building Administrators Building Administrators will inform building occupants about fire watch events and building evacuations.

Stillwater Area Community Services Center Inc.

Doc #: 2100-AD Revision: - 4M Fire Watch Procedures. Author(s): Tammie Lavoie

Fire Prevention Plan for McGrath Health and Wellness Center 1714 Cleneay Avenue

NFPA 70E Electrical Safety & Arc Flash Training

Builders Risk - Fire Prevention Inspection Checklist

This policy may also be used for routine work orders that are Life Safety in nature and cannot be completed within 45-days.

Element 14.7 Fire Prevention and Control 2018

Fire Safety Audit: Part B - Questionnaire (Questionnaire Devised By Mr.R.R.Nair) Yes No x

BURN NOTICE: KEEP THE HEAT AWAY!

Prepared by: Ronny J Coleman Jeff Shapiro Hugh Council IMPORTANT NOTICE

LABORATORY CHEMICAL HYGIENE AND SAFETY PLAN

Emergency Action Fire Prevention Plan

IIPP. Injury & Illness Prevention Program Hartog Drive San Jose CA Responsibilities. Workplace Hazards. Training. Incident Investigations

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

WORKPLACE EVALUATION CHECKLIST & REPORT

Slight Harm Moderate Harm Extreme Harm Low Trivial Risk Tolerable Risk Moderate Risk Medium Tolerable Risk Moderate Risk Substantial Risk

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

Fire Hazard Identification Checklist 1

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

CONSTRUCTION ENVIRONMENTAL HEALTH & SAFETY EXHIBIT FIRE PREVENTION AND PROTECTION

Family Foster Home Fire Safety Evaluation Checklist Instructions

Fire Safety Plan (FSP) Review Checklist 1

Fire Safety Plan (FSP) Review Checklist 1

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

Fire Prevention Plan

Facility Risk Assessment Questionnaire

FIRE PREVENTION 29 CFR Ursinus College, Collegeville, PA

Transcription:

1. Purpose The purpose of the University of Denver Hot Work policy is to protect personnel and property from a fire caused by hot work. The DU Hot Work policy defines the responsibilities and requirements for performing hot work and establishes controls through the use of a hot work permit. This policy establishes the means to assess the work area and the planned hot work activity to ensure sufficient and necessary controls are in place to prevent a fire. Hot work will only be performed in areas that are or have been made fire safe. Where fire prevention precautions, such as a fire suppression system or a fire or smoke detection system, are not sufficient a fire watch person shall be assigned to monitor the area for fire, as needed. 2. Authority OSHA 29CFR 1910.252 254 NFPA 51B 3. Scope This policy applies to all hot work performed on DU property, including work performed by DU employees and external contractors. Hot work includes any temporary operation, scheduled or emergency, indoor or outdoor, involving open flames or producing heat and/or sparks. Examples of hot work include torch cutting, welding, soldering, brazing, grinding. Permanent areas which are designated areas for long term or permanent performance of hot work, such as a maintenance shop or a detached outside location are not considered hot work as defined above. A hot work permit is not required for: Operations performed that do not generate sufficient heat or sparks to be considered a significant source of ignition to surrounding combustibles; Operations performed in permanent areas, which are designated areas for long term or permanent performance of hot work, such as a maintenance shop or a detached outside location; Permanent areas where welding, torching, or cutting will be performed must have the following conditions to be exempt from this policy: area constructed of non combustible or fire resistive material essentially free of combustible and flammable content suitably segregated from adjacent areas equipped with a suitable exhaust system capable of removing the fumes and spent gases associated with Hot Work; 1

4. Responsibilities a. Environmental Health & Safety Manager The Environmental Health & Safety (EH&S) Manager is institutionally responsible for: overseeing the to provide for regulatory compliance assisting in evaluating specific work to determine if potential hot work exists inspecting and approving the job site for hot work, as needed prescribing any additional personal protective equipment (PPE) beyond the minimum required PPE maintaining copies of hot work permits for one year. b. Authorized Person An Authorized Person, employed by DU, shall be responsible for ensuring compliance with this policy. The applicable Project Manager will be the Authorized Person for contracted work. The authorized person shall have sufficient technical knowledge, training and practical experience in the hot work processes and their associated hazards. The authorized person is responsible for: ensuring hot work is identified and performed in accordance with this policy performing a hazard assessment of the scheduled hot work and the work area, as needed, to establish controls and fire watch requirements (see precautions & requirements section below) notifying the EH&S Manager of scheduled Hot Work obtaining any alarm system bypass that may be necessary and ensuring such alarm system is reactivated upon completion of hot work making sure that persons who will perform hot work have read and understand the assuring that persons who will perform hot work have demonstrated competency in the use of hot work equipment and are trained in performing hot work ensuring that high energy sources are isolated as needed in accordance with the Lockout/tagout policy 2

approving hot work permits submitting a copy of the permit to the EH&S Manager. c. Hot Work Employee The worker who is performing the hot work is responsible for: completing classroom hot work training to the requirements of this policy performing hot work in accordance with the requirements of this policy being familiar with the facility and how to sound an alarm in the event of a fire filling out the work area preparation section of the hot work permit making the work area fire safe and verifying on the permit that work can start insuring the required safety precautions per the hot work permit are followed. d. Fire Watch The Fire Watch, which simultaneously can be the worker, is responsible for: being alert to all conditions that may directly involve the safety of the cutter or welder and observing the cutter or welder for sparks, flame, or slag that lands on clothing or protective equipment being trained to the requirements of this policy having the appropriate fire extinguishing readily available being familiar with the facility and how to sound an alarm in the event of a fire extinguishing a fire and/or sounding the fire alarm calling emergency services at 911 and Campus Safety at 13000, as needed completing the Closeout section of the permit. 5. Precautions and Requirements A hot work permit must be completed prior to initiating hot work and posted at the work area. The work process shall include (1) an assessment of the facility condition, (2) preparation of the work area, (3) hot work activity, (4) closeout. 3

Hot work must be approved by the Authorized Person. For externally contracted work the applicable Project Manager is the Authorized Person. Hot Work is permitted only in areas that are or have been made fire safe. Hot Work equipment shall be in good working condition and fully inspected. The Authorized Person shall perform a hazard assessment of the scheduled hot work and the work area where the following conditions exist: o o o fire suppression system is not operable or does not exist fire/smoke detection system is localized only or does not exist special potential hazards such as work in a confined area, attic, or crawlspace in which an increased fire risk may exist This hazard assessment includes the identification on the permit any special precautions and controls and the fire watch requirements, which will be at least 60 minutes after completion and may include periodic checks for 2 or 3 hours. The floor around the area where the hot work is to be performed shall be swept clean and clear of debris for a radius of 35 feet. Combustibles shall be adequately protected or shielded, using flameproof materials. For torch cutting or welding, combustibles shall be relocated at least 35 ft horizontally from the work area. The edges of covers at the floor shall be tight to prevent sparks from going under the covers. Openings or cracks in walls, floors, or ducts within 35 feet of the Site shall be tightly covered to prevent the passage of sparks to adjacent areas. When torch cutting or welding is performed near combustible partitions or ceilings, fireresistant guards shall be provided to prevent ignition. Welding shall not be attempted on a metal partition, wall, ceiling, or roof having a combustible covering. Oil based paints and epoxies shall be no closer than three feet in any direction. Fully charged and operable fire extinguishers shall be available in the hot work area. The use of wall mounted fire extinguishers, provided in the facility, is prohibited. Available portable fire extinguishers shall include as a minimum, one 4A:40B:C rated extinguisher within 40 feet of the activity. Special precautions shall be taken to avoid accidental operation of automatic fire detection or suppression systems. If the possibility exists that automatic fire detection or suppression systems will be activated as a result of the work activities, then the automatic fire detection or suppression systems shall be isolated from the detectors located in the immediate area. Nearby personnel shall be relocated or suitably protected from heat, sparks, slag, arc 4

flashing, and infrared or ultraviolet radiation. The Hot Work permit is valid for only one day unless otherwise approved by the EH&S Manager. 5

DU Department / Contractor Building / location Authorized person Phone Date of Issue Description of work Facility / Area Conditions (completed by the Authorized Person) Is a fire suppression system (sprinklers) in place? Is an alarm detection system in place? Can the area be made fire safe with no special considerations? (Yes / No) (Yes / No) (Yes / No) Describe special precautions to be implemented and fire watch requirements if any answer is negative. Mark NA if not applicable. EH&S Manager notified Signature of Authorized Person Work Area Preparation (completed by worker) Fire suppression sprinklers, fire hoses, or fire extinguishers available and operable Smoke/fire detectors/alarms in immediate area temporarily disabled No combustible and flammable materials within 35 ft or protected with covers or guards Adequate mechanical or natural ventilation provided. Floors swept, debris cleared, cracks or holes in floors, walls covered Area barricaded from building occupants Hazards from energized electrical equipment properly controlled, i.e. properly grounded Personnel trained on the use of equipment and how to sound alarm Appropriate fire extinguisher certified for use and available Required PPE: safety glasses, flame resistant coveralls, flame resistant gloves, safety shoes Comments for unchecked items Permit approval Authorized Person Signature Date: Closeout Completion of work (initial and time, mark NA if not applicable) Work area cleaned and inspected Time Alarms/detectors reactivated time Fire Watch Time Fire Watch Time Fire Watch Time Name and signature Date & time closed Emergencies call 911 and 13000 (Campus Safety) 6