Newstar Door Closing Devices & Accessories

Similar documents
Newstar Locks. NEWSTAR form and function for life. BS Range. London Fire Brigade Range

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Hospitality Vertcial Market Our Ref: ABC123

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Education Vertcial Market Our Ref: ABC123

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Healthcare Vertcial Market Our Ref: ABC123

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Commercial Vertcial Market Our Ref: ABC123

DC200 Rack and pinion door closer with link arm

DC300 Rack and pinion door closer with link arm

ASSA ABLOY Door Closers. Rack & Pinion Closer DC120 HOLD OPEN DC120 NON HOLD OPEN EN 2/3/4

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Transport Vertcial Market Our Ref: ABC123

DC340 Rack and pinion door closer with guide rail or link arm

Uniclass L4181 EPIC D181. CI/ SfB (31.5) X. Orbis Classic Range

DC300 Rack and pinion door closer with link arm

Meeting the requirements of the Equality Act & Fire regulations. Which Door Control?

F O C U S D O O R C L O S E R S

Panic & Emergency Exit Hardware

CERTIFICATE OF APPROVAL No CF 5038 FREEMAN & PARDOE T/A ARROW ARCHITECTURAL

ABLOY DOOR CLOSERS Excatly the right choice

ABLOY DOOR CLOSERS Exactly the right choice

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

Orbis Commercial Range

ABLOY DOOR CLOSERS Excatly the right choice

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations

CERTIFICATE OF APPROVAL No CF 118 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 145 GEZE UK LIMITED

Public and Government Buildings

CERTIFICATE OF APPROVAL No CF 5350 TAIWAN DAEDALUS DOOR CONTROL CO. LTD

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 738 ALLEGION (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 5263 KCC ARCHITECTURAL

ABLOY DC335 DOOR CLOSER New Rack and Pinion Door Closer ABLOY DC335 is a modern high quality door closer for all kind of door applications.

Ironmongery Performance Specifications

CERTIFICATE OF APPROVAL No CF 114 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 388. Allegion (UK) LTD

Layout S. 6 DORMA CI-2012 Englisch Stand

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

CERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD

Section July 2012 Sect.11.1 Prices excl. VAT

Concealed cam-action door closer system DORMA ITS 96

CERTIFICATE OF APPROVAL No CF 117 DORMA UK LTD

Orbis Commercial Range

CERTIFICATE OF APPROVAL No CF 5075 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 494 HOPPE (UK) LIMITED

Regulatory Reform (Fire Safety) Order 2005

Easy-action Door Closer DORMA TS83

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

PANIC EXIT HARDWARE DX-500 Serie

TECHNICA DORMA. Controlled. d Door Closing. Closerss. appended hereto:

CERTIFICATE OF APPROVAL No CF 388 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON

CERTIFICATE OF APPROVAL No CF 5530 TALLERES DE ESCORIAZA S.A.U.

CERTIFICATE OF APPROVAL No CF 5494 ASSA ABLOY AB

The DDA Explained ARROW ARCHITECTURAL

An ASSA ABLOY Group brand Series. Architectural Door Closers

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Designed to provide immediate escape, first time, every time

ABLOY FIRE DOOR CLOSING SYSTEMS

All by design. ASSA ABLOY Door Controls

Cam action door closer system DORMA TS 93

01_TT_TST_04_61_GB.qxd :30 Uhr Seite 4. Door Closers and Door Control Systems

Hardware Selection Process

DORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut

BJ WALLER ARCHITECTURAL IRONMONGERS DOOR CLOSERS

1 Door closers. Door closers Technical information. The global leader in door opening solutions.

30 Minute Firedoor. 30 minute firedoor

REDEFINING DOOR HARDWARE SPECIFICATION

CERTIFICATE OF APPROVAL No CF 5542 ASSA ABLOY SECURITY SOLUTIONS

About the Instructor & Presenter:

Best practice guide. Electrically powered hold-open devices to BS EN in association with. Association of Building Hardware Manufacturers

ARCHITECTURAL IRONMONGERY. company overview

CERTIFICATE OF APPROVAL No CF 111 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON

London The Building Centre 26 Store Street London WC1E 7BT T: F:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CERTIFICATE OF APPROVAL No CF 5516 ALLGOOD PLC

Carey Automatic Door, LLC 1 - PNEUMATIC OPERATOR FOR SINGLE SWINGING DOOR

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

The Association for Specialist Fire Protection

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 689 BOSS DOOR CONTROLS

TS 93. Cam action door closer system in Contur Design

briton panic and emergency exit hardware

Product Guide. The highest possible standards. The best possible solutions. Manufactured in the UK. Cert No 5893 ISO 9001

CERTIFICATE OF APPROVAL No CF 5657 UNION ARCHITECTURAL HARDWARE

ARCHITECTURAL Product Guide

GEZE DOOR TECHNOLOGY. Geze now partnered with Häfele! Brought to you by Häfele

CERTIFICATE OF APPROVAL No CF 850 ZOO HARDWARE LIMITED

CERTIFICATE OF APPROVAL No CF 646 EUROSPEC ARCHITECTURAL HARDWARE LIMITED

CERTIFICATE OF APPROVAL No CF 5506 ALLEGION (UK) LIMITED

A Studco Innovation. Openings & Finishings

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Operating and maintenance instructions. for windows, doors and façades made from steel profile systems

High Security Locking. Product Catalogue

Security Door Closer Safe and secure by design. ASSA ABLOY Door Controls

TS 93. Cam action door closer system in Contur Design

CI/SfB (31.59) X. April Briton. Overhead Door Controls 2100 Series

Controlled Door Closing Devices

SECTION HARDWARE

YALE DOOR CONTROL. Yale Door Control Catalogue 1300 LOCK UP ( ) yalelock.com.au. An ASSA ABLOY Group brand

Fire Protection. Intumescent fire and smoke seals for door assemblies

WDC SERVICE SOLUTIONS LTD

Transcription:

Newstar Door Closing Devices & Accessories NEWSTAR form and function for life

Surface overhead door closers Bary Cam Low opening force surface track arm door closer SL-144 SIL SNP PCP 30 Functional Criteria Door Widths from 750mm to 950mm. Door Weights 20kg to 60kg. Adjustments include; 1. Latching Speed. Final 10 Degrees. 2. Closing Speed. 10-110 Degrees. 3. Adjustable Spring Strength. BS Sizes 1-3. By valve. Available arms 1. Track Arm. 2. Track Arm Hold Open. Do not use hold open closers on fire doors. BS EN 1154 Classification 3 8 3 1 1 1 3 Dimensional Requirements Slide cover Full cover Length 238mm 264mm Height 58mm 61mm Projection 36mm 38mm Guarantee 10 years A free replacement ex-works of any closer proved defective by reason either of faulty manufacture or defect in material. Fire Tested by Warrington apt BS 1634-1 2000 30 minutes C01

Single action door closers Bary Cam concealed overhead door closer CL-144 Power adjustable by valve. Low opening force. SE 60 Functional Criteria Door Widths from 750mm to 950mm. Door Weights 20kg to 60kg. Adjustments include; 1. Latching Speed. Final 10 Degrees. 2. Closing Speed. 10-110 Degrees. 3. Adjustable Spring Strength. BS Sizes 1-3. By valve. Available arms 1. Track Arm Standard. 2. Track Arm Hold Open. Do not use hold open closers on fire doors. BS EN 1154 Classification 4 8 3 1 1 1 3 Dimensions 19mm 25mm 460mm 340mm 6mm 29mm Fire Tested by Warrington apt BS 476 Part 22 60 minutes. 60 intumescent pack available. Note: 36mm thick, add 4mm when fitting intumescent pack. 36mm 64mm 330mm Guarantee 10 years 239mm 260mm A free replacement ex-works of any closer proved defective by reason either of faulty manufacture or defect in material. C02

Double action door closers Bary Cam Double action door closer CL-144.DA Power adjustable by valve. Low opening force, c/w Pivot Set C-4-C SE 60 Functional Criteria Door Widths from 750mm to 950mm. Door Weights 20kg to 60kg. Adjustments include; 1. Latching Speed. Final 10 Degrees. 2. Closing Speed. 10-110 Degrees. 3. Adjustable Spring Strength. BS Sizes 1-3. By valve. Available arms 1. Track Arm Standard. 2. Track Arm Hold Open. Do not use hold open closers on fire doors. Fire Tested by Warrington apt BS 476 Part 22 60 minutes. 60 intumescent pack available. Note: 36mm thick, add 4mm when fitting intumescent pack. Guarantee 10 years A free replacement ex-works of any closer proved defective by reason either of faulty manufacture or defect in material. BS EN 1154 Classification 4 8 3 1 1 1 3 C03

Floor springs Power adjustable double and single action floor springs PA322 SSS 60 Functional Criteria Door Widths from 750mm to 1100mm. Door Weights 20kg to 80kg. Adjustments include; 1. Latching Speed. Final 15 Degrees. 2. Closing Speed. 15-180 Degrees. 3. Adjustable Spring Strength. BS Sizes 1-4. 4. Optional hold open 90 Degrees. Available Accessories; 1. Double Action 2. Single Action Dimensions Box: 50 x 290 x 80mm Top Plate:1.6x310x105 BS EN 1154 Classification 4 8 4 1 0 1 3 Fire Tested by Warrington apt BS 476 Part 22 60 minutes Guarantee 10 Years A free replacement ex-works of any closer proved defective by reason either of faulty manufacture or defect in material. C04

Door closers Transom door closer Transom Door Closer with or without hold open. Side loaded. Plate for wooden doors SSS Door Widths up to 1250mm. Door Weights up to 150kg. Suitable for use in temperatures from -15 to 40 Degrees Celsius.. Adjustments include; 1. Latching Speed. Final 10 Degrees. 2. Closing Speed. 10-130 Degrees. 3. Spring Strength. Sizes 3 & 4. 4. Adjustable Back Check. Not Available. 5. Delayed Action. Not Available. C-103 Size 3 Non Hold Open. CS-103 Size 3 Hold Open. C-104 Size 4 Non Hold Open. CS-104 Size 4 Hold Open. Not suitable for fire doors. Can be used on wood doors. SSS cover plate required 130 x 325 x 1.5mm available. TP.TRANSOM Available Arms; 1. Track Arm Standard. 2.Track Arm Hold Open. Finish: Silver Body/Polished Chrome Arm. Special finishes to order. Product Performance Classification Fire QA C-103 BSEN1154 4 8 3 4 0 1 3-9001 CS-103 BSEN1154 4 8 3 4 0 1 3-9001 C-104 BSEN1154 4 8 3 4 0 1 3-9001 CS-104 BSEN1154 4 8 3 4 0 1 3-9001 C05

Door closers Overhead door sliding closer TYPEIII SE Surface mounted sliding door closer, for lightweight doors only, with closing speed and closing power adjustment. For fixing to existing sliding door systems. To suit door sizes from 800-900mm. 40kg maximum door weight. Non Fire Rated. To be used with existing door gear, extension length of 915 mm A. Speed adjustment B.Closing force adjustment (factory adjusted) l Can be fitted to installed light-weight doors in homes, stres etc. l Applicable for door with a stroke of 590-900mm and a maximum weight of 40kg. l Product available in one standard length. l Same unit can be fitted to right or left hand door panel. Closing power and speed adjustable. l Applicable for doors that can be opened freely using 0.7kg of force or less. C06

Barymatic jamb closer/bary catch Adjustable speed hydraulic jamb closer Door Frame SCP 30 60 x = not greater than 300mm y = not greater than 44mm Features Adjustable Speed Adjustable Latch Suitable for Doors up to 940mm width and 80kg 5 Year Guarantee BSEN9001 A free replacement ex-works of any closer proved defective by reason either of faulty manufacture or defect in material. Performance Tested to 500,000 Frequency One Hour + Half Hour UK Fire Test WC UK Patent 0300204.5 Warning This product is not designed and built for door openings of no more than 120 degrees, failure to comply will invalidate the guarantee on this product Bary catch HL1 ZP EB Cover plates SSS PSS PB BRZ C07

Double & single action pivots Single action accessories DA.AP 60 SSS 60 SSS Double action accessories SA.AP (Handed) Bottom bearing pivot SSS C-9-C 68 28 Capacity 80kg C08

Double action pivot set C-4-C 30 SSS Ideal for use in hospital/disabled toilets. Normally used in conjunction with the Emergency Release C-5-C or C-7-C. Special Strike Plates available to suit Double Swing application. 80kg weight carrying capacity. Fire Tested by Warrington apt BS 476: PART 20: 1987 30 minutes C09

Emergency release C-5-C 30 SSS 115 8.5 16 51 12 18 50 26 34.5 3.5 Allows double swing doors to operate as single swing doors when used in conjunction with Double Action Set C-4-C. Ideal for use in hospital/ disabled toilets etc. 41.5 12 54 115 3.5 Fire Tested by Warrington apt BS 476: PART 20: 1987 30 minutes C10

Emergency release C-7-C 30 SSS Allows double swing doors to operate as single swing doors when used in conjunction with double action set C-4-C. Ideal for use in hospital/disabled toilets etc. Stop release resets after use. Fire Tested by Warrington apt BS 476: PART 20: 1987 30 minutes C11

Double swing strikes Din Locks double action strike plate C-6-C SSS PSS To suit lining 90-110mm UK Locks double action strike plate C-8-C SSS PSS To suit lining 90-110mm C12

Door selector Door selector SF.250F Colour options SSS PSS PB 275mm The SF.250F Door Selector is Designed to be fitted to a set of rebated doors, the idea is to slow one leaf down to allow the right leaf to sit in the frame before the other leaf, this is to ensure that the pair of doors close correctly. BS EN 1158: 1997 + A1: 2003 Classification 3 5 3 0 1 2 Rubbing plates RP1 Metal Door Installation SSS (Back Plate) t=min. 4.5mm. 200mm long Approx. Wood Door Installation C13

Stays Mortice limiting stay 930000 Limiting the opening angle of a door to 90 degrees 60 ZP Proposed Classification in accordance with DHF Technical Specification 003 : Selectively applied door opening restrictors for security purposes : November 2005 1 - - 1-2 3 L Associated Standards BS 8213-1:2004 Windows, doors and rooflights. Part 1: Design for safety in use and during cleaning of windows, including door height windows and roof windows - Code of practice BS EN 1634-1:2000 Fire resistance tests for door and shutter assemblies Part 1: Fire doors and shutters BS EN 1670:1998 Building hardware Corrosion resistance Requirements and test methods C14

Stays Surface limiting stay 930001 30 SE SNP PCP Limiting the opening angle of a door to 90 degrees Proposed Classification in accordance with DHF Technical Specification 003 : Selectively applied door opening restrictors for security purposes : November 2005 1 - - 1-3 3 L Associated Standards BS 8213-1:2004 Windows, doors and rooflights. Part 1: Design for safety in use and during cleaning of windows, including door height windows and roof windows Code of practice BS EN 1634-1:2000 Fire resistance tests for door and shutter assemblies Part 1: Fire doors and shutters BS EN 1670:1998 Building hardware Corrosion resistance Requirements and test methods Application Suitable for use with timber, steel and aluminium outward openning doors. Description Face mounted friction stay allows door opening to be limited to 90. The variable friction mechanism can be adjusted by rotating hexagonal bolt C15

Surface overhead door closers Power adjustable by valve surface overhead door closer EN25 & EN25.BC/DA SIL SE PCP PB SNP 60 CE CF526 Slide Cover or full Cover Options available. C16

Surface overhead door closers Functional Criteria Door Widths from 850mm to 1250mm. Door Weights 40kg to 100kg. Adjustments include; 1. Latching Speed. Final 10 Degrees. 2. Closing Speed. 10-180 Degrees. 3. Adjustable Spring Strength. BS Sizes 2-5. 4. Adjustable Back Check. 70-85 Degrees. 5. Adjustable Delayed Action. 180-65 Degrees. 20 Seconds minimum to BS. Set @ 40 seconds. Available arms 1.. Standard. 2. Parallel Arm. 3. Hold Open Arm. 4. Track Arm. 5. Track Arm Hold Open. Power Shoe arm bracket as standard Note When using parallel arm and slide arm application increase the closer power by one more size. Do not use hold open closers on fire doors. Classification confirmed by Warrington apt 1121-CPD-AD0110 BS EN 1154 Classification 4 8 5 2 1 1 3 Fire Tested by Warrington apt BS 1634-1 2000 & BS 476 Part 22 60 minutes Dimensional Requirements Slide cover Full cover Length 236mm 258mm Height 54mm 72mm Projection 38mm 40mm Guarantee 20 years A free replacement ex-works of any closer proved defective by reason either of faulty manufacture or defect in material. C17

Surface overhead door closers Power adjustable by valve surface overhead door closer EN24.BC SNP PCP SIL SE 60 C18

Surface overhead door closers Functional Criteria Door Widths from 850mm to 1100mm. Door Weights 40kg to 80kg. Adjustments include; 1. Latching Speed. Final 10 Degrees. 2. Closing Speed. 10-180 Degrees. 3. Adjustable Spring Strength. BS Sizes 2-4. By Valve 4. Adjustable Back Check. 70-85 Degrees. Available arms 1.. Standard. 2. Parallel Arm. 3. Hold Open Arm. 4. Track Arm. 5. Track Arm Hold Open. Power Shoe arm bracket as standard Note When using parallel arm and slide arm application increase the closer power by one more size. Do not use hold open closers on fire doors. Classification confirmed by Warrington apt 1121-CPD-AD0110 BS EN 1154 Classification 4 8 4 2 1 1 3 Fire Tested by Warrington apt BS 1634-1 2000 Dimensional Requirements Length Height Projection Guarantee 10 years Full cover 258mm 62mm 44mm A free replacement ex-works of any closer proved defective by reason either of faulty manufacture or defect in material. C19

Surface overhead door closers Surface overhead door closer Bary B SIL PCP PB SNP PL 60 CE C20

Surface overhead door closers Functional Criteria Door Widths from up to 950mm. Door Weights 40kg to 65kg. Adjustments include; 1. Latching Speed. Final 10 Degrees. 2. Closing Speed. 10-180 Degrees. 3. BS Sizes 2-4. By Template Option. Available arms 1.. Standard. 2. Parallel Arm. Power Shoe arm bracket as standard Note When using parallel arm and slide arm application increase the closer power by one more size. Do not use hold open closers on fire doors. Classification confirmed by Intertek GZ 09120873-1 BS EN 1154 Classification 3 8 3 1 1 3 Fire Tested by Warrington apt BS 1634-1 2000 60 minutes Dimensional Requirements No cover Full cover Length 180mm 190mm Height 40mm 55mm Projection 63mm 65mm Guarantee 10 years A free replacement ex-works of any closer proved defective by reason either of faulty manufacture or defect in material. Plastic cover Finished cover C21