Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Similar documents
C-Bus Bus Coupler with Scenes 5102BCLEDL 5104BCL

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Light Level Detector, Surface Mount 5754PE. Installation Instructions

C-Bus Black & White MK II Touch Screen. 5000CT2 Series. User s Guide

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

C-Bus Black & White MK II Desktop Touchscreen. 5000CTD2 Series. User s Guide REGISTERED DESIGN REGISTERED PATENT

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

C-Bus Neo Range Installation Instructions. 5050NL Series

Push Button Electronic Timer. 31VETR Series. Installation Instructions

C-Bus Reflection Range Installation Instructions

C-Bus Four Channel Analogue Output Unit Installation Instructions

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

QUICKSMART Universal Exit Light EXITSM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Mains Power Filter 970MF10 970MF20. Installation Instructions

Passive Infrared Motion Detector 5420/90P. Installation Instructions

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Square D Clipsal Outdoor Light-Level Sensor

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

WAFER Recessed Edgelite Exit LED EXITREC. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

F Type Shielded Masthead Amplifier 3105MH35U18V DIGITAL TERRESTRIAL TELEVISION READY. Installation Instructions

C-Bus Four Channel General Input Unit Installation Instructions

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Universal Dimmer E450UD Series. Installation Instructions

Dimmer / Fan Controller Installation Instructions

Line Isolation & Overload Monitor. E05 Series. Installation Instructions MU TE TE S T E. S.P. ALARM MUT E D OVE R LOAD WAR NING PHC WARNING

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

Three Speed Capacitive Fan Controller. 4060CSFM Series. Installation Instructions 75VA

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

Ceiling Mounted Ducted Exhaust Fan Kit

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

PERSONAL CUEING DEVICE MODEL NO. BDAAU100 INSTRUCTION MANUAL.

Home Doorway Alert Kit

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Honeywell Temperature & Humidity Sensor with LCD

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L

Wireless Driveway and Intruder Alert

Atomic Digital Wall Clock

Installer Guide smart connect

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

safety & regulatory information

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Projection Alarm Clock

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

Little Anne. Important Product Information

6 Sheet Strip-Cut Shredder for Home/Office

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

SC-6 Six Supervised Control Module

Wireless Home Appliance Timer Remote Control Kit

Long Range Radio Alarm Transmitter

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

Towel Warmer MAKE EVERYDAY A SPA DAY

READ ME FIRST DIY WIRELESS ALERT. Gate Alert Kit. Instruction Manual

IDP-Zone-6 Six Zone Interface Module

180 Degree Ceiling Mounted Occupancy Sensors

Conserve Socket Power Timer. User Guide

Please Keep This Manual For Future Reference REV.01

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

Projection Alarm Clock USER GUIDE

MMF Six Zone Interface Module

Installation and Operation Guide

Pure Glass. saturn.clipsal.com

Twin Bell Digital Clock

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

75 Sheet Micro-Cut Shredder With CD/DVD Slot

Wireless Rain Gauge with Indoor Temperature

Universal Clamp Meter

Owner s Manual. PIR-1 IR Learner

programmable control model installation and setup guide M /11/ Hunter Fan Company

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

Ambient Weather RC-9362 Atomic Digital Wall Clock with Temperature User Manual

Universal Fan and Light Remote Control

Atomic Digital Office Clock

60W Security Spotlight. 754HB1/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

48 TAYLOR CEILING FAN

DeLaval activity meter system Instruction Book

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

DIGITAL ATOMIC WALL CLOCK

External Wireless Sounder

Installer Guide smart connect

40 Built-in Electric Fireplace Operating and Installation Instructions

AGES. instruction manual DAISY BLOOM PROJECTION ALARM CLOCK

ShockLink. Important Product Information.

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

Long Range Radio Alarm Transmitter

Wireless Color Weather Station

DEHUMIDIFIER. User Manual 50BT, 70BT

Transcription:

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd. Copyright Clipsal Australia Pty Ltd, 2008. All rights reserved. This material is copyright under Australian and international laws. Except as permitted under the relevant law, no part of this work may be reproduced by any process without prior written permission of and acknowledgement to Clipsal Australia Pty Ltd. The information in this manual is provided in good faith. Whilst Clipsal Australia Pty Ltd (CAPL) has endeavoured to ensure the relevance and accuracy of the information, it assumes no responsibility for any loss incurred as a result of its use. CAPL does not warrant that the information is fit for any particular purpose, nor does it endorse its use in applications that are critical to the health or life of any human being. CAPL reserves the right to update the information at any time without notice.

Contents 1.0 Product Range 5 2.0 Important Notes 5 3.0 Description 5 4.0 Installation Considerations 6 5.0 Mounting Instructions 6 5.1 Installing the A Series Fascia 8 5.2 Removing the A Series Fascia 8 5.3 Installing the E Series Fascia 8 5.4 Removing the E Series Fascia 8 6.0 C-Bus Network Connection 9 7.0 C-Bus Power Requirements 10 8.0 Megger Testing 10 9.0 Programming Requirements 10 10.0 Electrical Specifications 11 11.0 Mechanical Specifications 11 11.1 Saturn A Series Range 12 11.2 Saturn E Series Range 12 12.0 Standards Complied 13 13.0 Warranty 15 3

4

1.0 Product Range This document applies to the C-Bus Saturn Wall Switches listed below. Catalog Number 5082NL 5084NL 5086NL E5082NL E5084NL E5086NL Description C-Bus Saturn Wall Switch A Series, 2 button C-Bus Saturn Wall Switch A Series, 4 button C-Bus Saturn Wall Switch A Series, 6 button C-Bus Saturn Wall Switch E Series, 2 button C-Bus Saturn Wall Switch E Series, 4 button C-Bus Saturn Wall Switch E Series, 6 button Saturn wall switches are available with several fascia styles. Consult your Clipsal sales representative for fascia ordering options. 2.0 Important Notes Do not connect mains wiring to the C-Bus Saturn wall switch. The C-Bus network uses CAT-5, unshielded twisted pair cables. The use of any software not provided by Clipsal Integrated Systems (CIS) in conjunction with the installation of this product may void any warranties applicable to the hardware. Connection to the C-Bus network is easy. The installer connects the C-Bus plus (+) and C-Bus minus (-) at the rear of the unit. The input units must never be connected to mains. The installer does not need to have an electrician s license. 3.0 Description The C-Bus Saturn wall switch is a high-end C-Bus input unit. The Saturn range features multiple buttons, scene management and learn mode capability. Because each unit has a unique address on the network, the input unit can be daisy chained with other C-Bus network devices or it can be placed at the end of a cabling run. 5

Refer to Electrical Specifications and C-Bus Network Connections for more details. 4.0 Installation Considerations It is important to select the right location to install the C-Bus Saturn wall switch. Some considerations are listed below: Units are designed for indoor use only. Units may be mounted vertically or horizontally. Provide easy access to the unit for switching lights and selecting scenes. Choose a location free of water, humidity, direct sunlight and heavy dust. Allow adequate ventilation. Do not cover the unit. no wet hands no cleaner spray no coverage no direct sunshine no dust 5.0 Mounting Instructions A Series C-Bus Saturn wall switches suit standard rectangular 84 mm centre mounting accessories, such as the Clipsal 155, 155VH and 157/1. Mounting using a 157 series wall box is shown in Figure 1. It is recommended that wall boxes be earthed. E Series C-Bus Saturn wall switch input units suit standard square 60.3 mm centre mounting accessories, such as the Clipsal E157 and E5050MF. Mounting using an E157 series wall box is shown in Figure 2. Mounting accessories must be fitted a minimum distance of 10 mm back from the finished surface of the wall. When mounting vertically, fit the grid plate to the wall with the release locks at the bottom. 6

Figure 1. Mounting an A Series Saturn Wall Switch using a 157 wall box Figure 2. Mounting an E Series Saturn Wall Switch using an E157 wall box 7

5.1 Installing the A Series Fascia 1) Align the directional arrows on the back of the fascia to match the grid plate. 2) Fit the upper clips into the apertures at the top of the grid plate (the upper clips are longer than the lower clips). 3) Lower the bottom of the fascia to the grid, until the clips engage. 5.2 Removing the A Series Fascia 1) To disengage the lower release locks, use a small flat head screwdriver to push the release locks upward. 2) Swing the lower end of the fascia about 5 mm away from the grid, until it is free (refer to Figure 3). 3) Push the fascia upward and pull gently to release the upper clips. Figure 3. The release slots provide easy removal of the cover plate 5.3 Installing the E Series Fascia 1) Align the fascia so that the clips on its back align with those on the grid plate (the clips are on the side). 2) Gently push the fascia toward the grid plate until the clips engage. 5.4 Removing the E Series Fascia 1) Use a small flat head screwdriver to push the release locks at the side of the fascia. 2) Gently pull the fascia off the grid plate. 8

6.0 C-Bus Network Connection Connect the C-Bus Saturn wall switch to the C-Bus network using unshielded twisted pair C-Bus cable. See Figure 4. Twist or crimp the wire pairs together as shown. Do not use soldered connections; they are not reliable Use Category 5 (Cat-5) data cable (Clipsal catalogue number 5005C305B). Figure 4. C-Bus cable conductor assignments C-Bus Connection Colour Saturn C-Bus Connection C-Bus Positive (+) blue yes C-Bus Negative ( ) blue & white yes C-Bus Positive (+) orange yes C-Bus Negative ( ) orange & white yes Remote ON green no Remote ON green & white no Remote OFF brown no Remote OFF brown & white no Figure 5. Terminal Wiring 9

7.0 C-Bus Power Requirements The C-Bus Saturn wall switch input unit draws 22 ma from the C-Bus network. Adequate C-Bus Power Supply Units must be installed to support the connected devices. The Network window of a C-Bus Toolkit project provides a summary of a C-Bus network according to the units added to the database. This can be helpful in determining the power supply requirements of a particular network. 8.0 Megger Testing Never perform Megger testing on the pink C-Bus cabling or terminals as this may degrade the performance of the network. Megger testing of a mains electrical installation that has C-Bus Saturn Range input units connected will not damage the units. 9.0 Programming Requirements C-Bus Saturn Range input units are learn-enabled devices. This means you can create relationships between input and output units without a computer (using learn mode). Learn mode allows you to link multiple units into a common network. You can assign a load such as a light on a dimmer unit, with a controller such as a C-Bus Saturn Wall Switch, by touching the two units one after the other. Refer to the Quick start guide to programming: C-Bus2 Learn Units booklet for more information. In a sophisticated installation, some of the basic settings created by learn mode may need to be overridden to create a particular effect. The latest C-Bus Toolkit software may be downloaded from the Clipsal Integrated Systems website (www.clipsal.com/cis). 10

10.0 Electrical Specifications Parameter C-Bus supply voltage C-Bus AC input impedance Electrical isolation Maximum number of units on network Control functions Status indicators Warm-up time C-Bus connection Operating temperature range Operating humidity range Description 15 to 36 V DC, 22 ma for normal operation. Does not provide current to the C-Bus network 50 kω @ 1 khz 3.75 kv RMS from C-Bus to mains (provided externally to 508xNL Series unit) 50 Load switching, dimming, timers, scene control User configurable orange and blue 5 seconds One terminal block to accommodate 0.2 mm 2 to 1.3 mm 2 (24 to 16 AWG) 0 to 45 C 10 to 95%, non condensing 11.0 Mechanical Specifications Parameter A Series E Series Dimensions (W H D) 75 x 116 x 28 mm 87 x 87 x 28 mm Protrusion from wall 13 mm 13 mm Base depth (into wall) 15 mm 15mm Mounting Centres 84 mm 60 mm Weight 51 to 54 g 37 to 39 g 11

11.1 Saturn A Series 11.2 Saturn E Series 12

12.0 Standards Complied DECLARATIONS OF CONFORMITY Warning: Any changes or modifications not expressly approved by Clipsal Integrated Systems could void the users authority to operate this equipment. The C-Bus Saturn Range 508xNL and E508xNL series comply with the following: Australian/New Zealand EMC & Electrical Safety Frameworks and Standards Regulation Standard Title EMC AS/NZS CISPR 14-1 AS/NZS CISPR 15 Electromagnetic compatibility Requirements for household appliances, electric tools and similar apparatus Part 1: Emission Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment European Directives and Standards Regulation Standard Title EMC Directive 2004/108/EC EN60669-2-1 Clause 26.1 EN 60669-2-1 Clause 26.2 EN55014-1 EN55015 Immunity to ESD, RFI, EFT, Surge Voltages, Voltage Dips and Interruptions RF and Low Frequency Emissions RF and Low Frequency Emissions RF and Low Frequency Emissions 13

US FCC Regulations Regulation FCC Part 15, Subart B Title Radio Frequency Devices Unintentional Radiators Supplemental Information This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable operation. Class B Product NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: reorient or relocate the receiving antenna increase the separation between the equipment and receiver connect the equipment into an outlet on a circuit different from that to which the receiver is connected consult the dealer or an experienced radio/tv technician for help. Other International Directives and Standards Regulation IEC Standard Title EMC IEC 60669-2-1 Clause 26 CISPR 14-1 CISPR 15 RF and Low Frequency Emissions RF and Low Frequency Emissions RF and Low Frequency Emissions 14

14.0 Warranty The C-Bus Saturn Wall Switch carries a two-year warranty against manufacturing defects. Warranty Statement 1) The benefits conferred herein are in addition to, and in no way shall be deemed to derogate; either expressly or by implication, any or all other rights and remedies in respect to Clipsal Product, which the consumer has under the Commonwealth Trade Practices Act or any other similar State or Territory Laws. 2) The warrantor is Clipsal Australia Pty Ltd, with registered offices in all Australian States. 3) This Clipsal Integrated Systems Product is guaranteed against faulty workmanship and materials for a period of two (2) years from the date of installation. 4) Clipsal Australia Pty Ltd reserves the right, at its discretion, to either repair free of parts and labour charges, replace or offer refund in respect to any article found to be faulty due to materials, parts or workmanship. 5) This warranty is expressly subject to the Clipsal Integrated Systems Product being installed, wired, tested, operated and used in accordance with the manufacturer's instructions. 6) All costs of a claim shall be met by Clipsal Australia Pty Ltd, however should the product that is the subject of the claim be found to be in good working order, all such costs shall be met by the claimant. 7) When making a claim, the consumer shall forward the Clipsal Integrated Systems Product to the nearest office of Clipsal Australia Pty Ltd with adequate particulars of the defect within 28 days of the fault occurring. The product should be returned securely packed, complete with details of the date and place of purchase, description of load, and circumstances of malfunction. For all warranty enquiries, contact your local Clipsal sales representative. The address and contact number of your nearest Clipsal Australia office can be found at http://www.clipsal.com/locations or by telephoning Technical Support 1300 722 247 (CIS Technical Support Hotline). 15

clipsal.com