WINTERIZATION DRIP IRRIGATION SYSTEM

Similar documents
Electric Pressure Washer

LC Series - Light Commercial Pump Station Installation and Operation Manual

SAFETY AND OPERATING MANUAL

Electric Pressure Washer

Model HD 3501 Part No High Pressure Washer Operator Manual

Model K 3000 G Part No

Model K 520 M Part No

Model K 5800 G Part No

K Specifications. Max. Water Volume

K 3.97 M. Specifications or visit our website: In USA call: Part No

DISPENSING TROUBLESHOOTING INDEX

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

POOL WINTERIZING INSTRUCTIONS

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

High Pressure Washer Operator Manual. Specifications Model HD 2700 DH/DB

K Specifications. Max. Water Volume

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

Model K 240 plus Part No

Model K 4400 G Part No High Pressure Washer

BEFORE OPERATING THE MACHINE: WARNING

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

Model K 330 M Part No

Well Disinfection. Safety Concerns. Electrical. Chemical

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

Closing procedures for above-ground pools

PRE INSTALLATION PROCEDURES

Automatic Water System Pump SERIES

MODEL SW-2. Sample specifications for SW-2 SPECIFICATIONS

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841

Clear Comfort Residential Pool & Spa Sanitization System Installation, Operations & Maintenance Manual

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

HF345 S9 Operators Manual

Niles Steel Tank Hot Water Generator Installation and Operation Manual

Daikin Water Cooling, Heating, and High Capacity Booster Coils

Explorer CleaningPartsDirect.com Carpet Extractor. Operator and Parts Manual. Home Find... Go To.. Model No.: Can.

Model K 280 M Part No

Water Distribution Study Guide Class III (Made available by: Kansas Rural Water Association)

Read this entire manual before operation begins.

WARRANTY TABLE OF CONTENTS TECHNICAL SPECIFICATIONS. Product Warranty Always keep your receipt as proof of purchase. Technical specifications...

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

Hoshizaki America, Inc.

Drainage and Irrigation

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

GOLF TECHNICAL BULLETIN

Model K205 M Plus Part No

Electric Pressure Washer

Electric Pressure Washer

Closing procedures for in-ground pools

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

Ozone Generator Systems

Model HD 3000 Part No High Pressure Washer Operator Manual

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

Next Generation Corona Discharge Installation & Operation Manual

Please take time to carefully read through these guidelines before using your Kamco pump.

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use.

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

WINDSHIELD REPAIR MANUAL SUPER CINCH

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Elite Primer Baldor Series External Pond Pump

8648 Series Air/ Water/ Vacs. Product Information. Important Safety Instructions. Operating Instructions Maintenance & Troubleshooting REV

PZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series

USER MANUAL/Installation Instructions LRV-4

INTRODUCTION / TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Installation Instructions

IMPORTANT INSTRUCTIONS READ & SAVE

8 lb Lightweight Vacuum Model CK LW 13/1

CHAMPION PUMP OWNER S MANUAL

SYSTEMS for CATALYTIC FILTERS

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

G 2000 ET. English 2 Español 15 Français 30! /06

Hoshizaki America, Inc.

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

Maintenance 5-1. Good maintenance is essential for cleaning results, and long economical life of the washer.

Power Washer Maintenance

Type N RotoClone. Hydrostatic Precipitator. Better Air is Our Business

Hardwired Electric Garage Heater

Lubi Submersible Condensate Removal Pumps

SUBMERSIBLE WATER PUMPS

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

Models Product Information. Important Safety Instructions REV

Pumps SELECTION OF A PUMP

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

Guidelines to Minimize Phytophthora Contamination in Restoration Projects

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

GROWMAX WATER Perfect Water for Plants and Gardens

IMPORTANT INSTRUCTIONS READ & SAVE

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

American Hydro Systems

PolyMax H2-24 Dutch Bucket System

10.1 Troubleshooting Condition Table

INSTRUCTION MANUAL PRODUCT VIEW

Please take time to carefully read through these guidelines before using your Kamco pump.

* * English. Operator Manual. Carpet Cleaner Rev. 01 ( ) Model V

Monsoon RS400. Operating Instructions Mode d emploi Bedienungsanleitung Manual de Instrucciones Istruzioni per il funzionamento Gebruiksaanwijzing

Transcription:

WINTERIZATION DRIP IRRIGATION SYSTEM CHECK LIST Erick Smith, Dario Chavez, Tim Coolong, and Lenny Wells, UGA Department of Horticulture Wesley Porter, UGA Department of Crop and Soil Sciences As the season progresses into winter, colder weather signals time off from fieldwork. Before entering the confines of a warm shop to maintain equipment, one last task is at hand: irrigation winterization. Winterization is the removal of water from the system s components: pump (if above ground), back-flow regulator (preventer), filter, pressure regulators, flow meter, valves, connectors, pipe, tanks, injectors, and drip tubing (Figure 1). While many vegetable irrigation systems may be kept running during the winter months to produce cool season crops, zones that are not used until spring are ideal candidates for winterization. Before winterization, it is suggested that a 2-ppm solution of chlorine be run through the system. The chlorine can clean the system, and it should not interfere with perennial crops (such as blueberry) that are about to enter dormancy. Never mix bleach with acids or ammonia, which will form irritating and toxic compounds. Figure 1. Typical components of a drip irrigation system.

System winterization is a good time to conduct a detailed check on the operation of system components, replace damaged components, and drain the water from the system. This is preferably done before the first freeze. If not already in place, installing automatic drain valves (ADV; Figure 2) or flush valves will help to remove water from systems that are on flat ground or have low points. Most ADVs are pressureactivated rubber valves that close at 9-10 PSI. When pressure drops below a predetermined level, the valve opens. ADVs are installed downstream of the control valves and work well when positioned at low points in an irrigation zone, allowing water to drain from the system. If ADVs have not been installed, manual valves (Figure 3) placed at low points in the system work in the same fashion with a little more manual effort. However, ADVs and manual valves cannot completely drain all of the components. The following are some suggestions for winterization of your drip irrigation system. Winterization Check List: Power units Power units should be sealed to protect from critter nesting, moisture, and debris like pine needles and leaves. To achieve this, wrap combustion or electric motors in tarps or have the unit protected by a shed (Figure 4). Place exclusion barriers on the equipment where wind-blown debris and critters cannot enter. For more information, see UGA Extension Circular 1093. Figure 2. An example of an automatic drain valve (ADV) or flush valve for low-pressure systems. Figure 3. Ball (right) and gate (left) valves that can be used as drain valves in a drip irrigation system. Figure 4. A shed constructed over the well head, pump motor, and electrical controllers. UGA Cooperative Extension Circular 1094 Winterization Drip Irrigation System Check List 2

Pumping system If operating an aboveground centrifugal pump, the pump housing will need to be drained. Usually, manufacturers place a threaded plug at the base of the pump housing for this purpose. However, the plugs may be difficult to remove once the pump is mounted. Installing a valve where the plug was threaded into the pump housing makes draining the pump much easier. For turbine or submersible pumps, the installation is usually below the frost/freeze line in the soil and will not need special attention. Suction (intake) line (for surface water) Pull the line from the water reservoir, drain water from the line, and verify that the intake line and screen are clear. After draining the pipe, cover the open ends to keep critters from entering the pipe. This keeps nesting material and other debris from entering the pipe, which could eventually be drawn into the pump impeller. Valves, components, and piping From the backflow valve through the system, it is important to drain water from components, piping, and any elbows, low points, and isolated piping. Open all valves, as closed gate and ball valves trap water and can crack/break when repeated freeze/ thaw cycles occur. Solenoid valves should be left in an open position. To do this without removing the valve, either unscrew the bleeder knob, which is usually located on the top of the valve (¼ ½ turn is sufficient), or unscrew the solenoid a ¼ turn, which is the part with the wires protruding (Figure 5). Other inline components Other inline components should be inspected and drained of water. Flow meters (Figure 6), pressure gauges, manual valves, air-vacuum relief valves, and back-pressure valves are usually mounted on the top or side of a water line to ensure that water does not collect in the housing of the device. If mounted at a low point or at the underside of a line, take extra precautions to drain the device, which may involve removing the device from the line to allow it to drain. The screen and sand filters should be drained, inspected, and cleaned. Figure 5.. Solenoid valve A = bleeder knob (¼ ½ turn to open) and B = solenoid (¼ turn to open). Figure 6. Position flow meter at the top of the line to ensure that water does not collect in the meter and is not susceptible to freezing. UGA Cooperative Extension Circular 1094 Winterization Drip Irrigation System Check List 3

Electrical systems ELECTRICITY KILLS. USE PROPER SAFETY PROCEDURES when checking these systems. Generally, electrical pumps for irrigation are run with alternating current (AC) at 60 Hz (cycles per second). For greater water demand voltages as high as 480 volts three-phase electrical power sources are used to run motors. The ampere (amp) is a measure of energy or electricity moving (current) through the line. It is the ampere that makes muscles contract, causing the hand to grab on to a live electrical line and not let go. At 30 milliamps being pushed at 60 cycles, sustained contact can cause tissue damage and lead to ventricular fibrillation, heart attack, or death. Good safety practices include using a lock-out/tag-out system, keeping systems properly grounded, and maintaining a properly functioning multimeter. When first handling electrical fixtures, fill out tags, put locks on the breakers, wear rubber soled shoes, and remember that the first item to enter a fixture, service box, or controller should be the probes of the volt meter to check if any of the lines are hot. Once this is done, inspect and replace all damaged wires for damage. Then tighten all contacts. Resistance is measured in ohms, which results in heat, and as metal heats and cools, contacts loosen and create greater resistance. This increased resistance can cause fuses to blow and breakers to trip. Look for signs of burns, water leaks, and wear on individual components. Remember one rule of thumb for handling electrical fixtures: NEVER GRAB A FIXTURE WITH YOUR PALM DOWN. Use the back of your bare hand. If the fixture is charged, the natural muscle contraction will cause your hand to pull away from the fixture instead of grabbing it. If you are unsure about any part of the electrical inspection, CALL A LICENSED ELECTRICIAN! Chemigation System Winterization Check List Chemical injection systems are available in simple to sophisticated systems that apply exact amounts of product. However, they all need maintenance and a thorough inspection before operation. If injecting acid, use extreme caution when working with the system, and wear a face shield, acid-resistant rubber gloves, and an acid-resistant apron. In addition, have an eyewash and safety shower immediately accessible. Even when working on a non-acid injection system, the proper protective gear should be used to prevent exposure to the products being injected. The personal protective equipment (PPE) is listed on the label of the product and is a function of the product s chemistry. Always use the highest level of PPE recommended from the label to minimize the risk of exposure. Remember that the injection system has the most concentrated formula passing through it! UGA Cooperative Extension Circular 1094 Winterization Drip Irrigation System Check List 4

Fertilizer injection systems often represent a weak point in winterization. Because injection systems handle concentrated salt solutions, precipitation due to evaporation of water or during cold weather can result in problems when the system is reactivated in the spring. Fertilizer precipitates can clog systems and ruin injectors. In addition, the high salt content can lead to rapid corrosion of expensive metallic parts in the system, resulting in expensive repairs. To avoid costly repairs and lost production time, unhook fertilizer tanks and run clean water throughout the injection components to remove concentrated fertilizer and any salt build-up. Fertilizer tanks that remain unattended through the winter can precipitate salts (Figure 7). Generally, the salts form a layer at the bottom of the tank, completely clogging outlets. Draining and rinsing the fertilization tank regularly and at winterization can minimize problems of salt build-up and damage. Always drain fertilizers and tank rinses into a suitable container to be either recycled or disposed of in accordance to county, state, and federal regulations. If uncertain about the proper procedure, contact your county agent. A B Figure 7. Fertilizer feed tank that has not been cleaned or winterized, from the outside (left) and inside (right). See fertilizer salt deposits (a) and evaporated and precipitating fertilizer (b). Venturi injectors (Figure 8) Venturi injectors are generally manufactured with polypropylene, polyvinylidene fluoride, ethylene chlorotrifluoroethylene, or stainless steel, with varying degrees of tolerance to the chemistries of injected products and the environment. Check Valve Injector Removal of the injector and storage in a climatecontrolled area such as a shop is recommended to minimize weatherization. This includes lines and filters. If the injector intake is connected to a large reservoir or feed tank of fertilizer or acid, close the valve from the tank, run irrigation water through the chemigation hoses, cap off the valves on the feed tanks and store the hoses with the injector. Metering Valve Figure 8. Fittings on the venturi injector, usually made of plastic, should be inspected for weathering (Diagram from aces.nmsu.edu). UGA Cooperative Extension Circular 1094 Winterization Drip Irrigation System Check List 5

Mechanical pumps Use the manufacturer s recommendations for servicing your unit. Inspect and clean around the unit. Look for cracks, weathering, and dirt, and replace and clean where necessary. Inspect the valves and couplers from the feed tanks to the pump. In Figure 9, a variable in-line flow meter is being used for chemigation. The manufacturer s website provides technical data sheets with recommended maintenance for each of its models. Like the venturi injectors, use water to clean the pump and lines, and when possible, store the pump in a shop. Cap the valves to feed tanks and store connection hoses with the pump. Figure 9. Centrifuge pump with electric motor and a Blue-White variable in-line flow meter. Winterization Run-Down Check List: Open drain valves and flush the system with 2 ppm chlorine (0.75 ml/100 gal of water, with no acid or other injected products). Flush fertilizer injector system with water and chlorine. Drain the system. o o o Disconnect and drain any pipe or component in which water cannot be drained by gravity. Clean, inspect, and drain filters. Drain centrifugal pump housing. Figure 10. Well head, backflow, flow meter, filter, venturi, chemical totes, and electrical control panel under a lean-to structure. Inspect the system, note any parts that are damaged or worn, and prepare to replace those parts before the system will be put back into operation. Replacing worn and non-working parts before winter can save valuable time in the spring when the system is required for irrigation. Pull the suction line from the water reservoir (if applicable). Clean screens, drain, and cover any openings to keep critters and debris out. Place exclusion barriers around pump power units to eliminate critter nesting and wind-blown debris from collecting. Clean and store the chemigation systems. If the systems will be exposed to the elements, drain thoroughly and protect the units from the weather. Clean, drain, and coil up any hoses associated with the system to prevent damage, especially from critters. Ensure that no wires are exposed and that weatherproof boxes are sealed. Place a desiccant (such as silica gel packets) inside electrical boxes to minimize moisture. extension.uga.edu Circular 1094 August 2016 Published by the University of Georgia in cooperation with Fort Valley State University, the U.S. Department of Agriculture, and counties of the state. For more information, contact your local UGA Cooperative Extension office. The University of Georgia is committed to principles of equal opportunity and affirmative action.