PET IMMUNE PIR MOTION DETECTOR

Similar documents
HSD-200Z Z-Wave Motion Sensor

SZ-PIR04N ZigBee Motion Detector Installation Guide

Slim Multisensor PST02-A/B/C

DCH-Z110/Z120. Function Compare DCH-Z110/DCH-Z120. Add to/remove from Z-Wave TM Network

Slim Multisensor PST02-A/B/C

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

Wi-Fi DOOR/WINDOW SENSOR

Door/Window Sensor Installation Instructions

Devolo home Control Door/Window Contact MT 02648

SHARP. Multi Sensor User s Guide. Model: DN3G6JA069

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

ShockLink. Important Product Information.

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

Pet Immune SAW PIR Motion Sensor

SF812 SMOKE DETECTOR. Include to or Exclude from a Z-Wave TM Network. Product Overview

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

2 x screws. 2 x wall plugs

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

Wireless Outdoor Air Reset Adaptor PN:

Optima ZigBee Thermostat

ADT. Pulse 2017ADT LLC

PRODUCT DIAGRAM PACKAGE CONTENTS

Wireless External Alarm

FTS05 / FTS05P - Wireless Flood and Temperature Sensor, User Manual

Atomic Digital Office Clock

PRODUCT DIAGRAM PACKAGE CONTENTS

Wireless Weather Station

1100D Wireless Receiver

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

Zigbee Smoke Sensor PSG03

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

Smart Hub THERMOSTAT. Installation Manual

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

1100X Wireless Receivers

IX30 - Z-Wave PIR Detector User Guide

Draft - develop and review

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

Contents. User Manual GA-U-1. VultureNet: Long Range System

1126 Series Ceiling Mount PIR Motion Detector

GARAGE DOOR OPENER KIT

1125 PIR Motion Detector

Smart THERMOSTAT. Installation Manual

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Features and content. This is where air comes into your detector.

OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

Smart Radon Detector with Indoor Air Quality Sensors

Rev D 3/20/17

Touchscreen Comfort Control

ix30 Zwave PIR Sensor

Installer Guide smart connect

with motion sensor ITM. / ART Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Instruction Manual Water Sensor

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 6 Mounting 7 Probe Use 8 Probe Wrap Use 9

InTemp CX Temperature Logger (CX40x) Manual

ADC-T2000. Smart Thermostat v1.5

POP_ Smoke Detector

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

Smart Radon Detector with Indoor Air Quality Sensors Version 1, May 8, 2018

10 Year Smoke Detector and Siren

POP_ Smoke Detector

Z-Wave Network Inclusion/Exclusion/Reset

Automatic Dimming Mirror with HomeLink

Nest x Yale Lock Programming/Troubleshooting Guide

ZTS-500US Z-Wave Smart Thermostat

Yale Real Living Push Button Deadbolt Installation and Programming Instructions (YRD210)

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

Installer Guide smart connect

EL-TSTAT Owner s Manual

idevices Connected App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Mounting 7 Probe Use 7 Probe Wrap Use 9

SMARTHOME SECURITY & IQ PANEL USER GUIDE

Yale Real Living Push Button Lever Installation and Programming Instructions (YRL210)

EN1221S-60 Waterproof Pendant Installation and Operation Manual

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions (YRD220)

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

CONNEX Smart Thermostat CST R00

S541.RF 4G Product Guide

Smoke Bridge Owner s Manual

Yale Real Living Key Free Touchscreen Deadbolt Installation and Programming Instructions (YRD240)

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

Yale Assure Lock Push Button Deadbolt Installation and Programming Instructions ( YRD216/YRD416)

Technical support is also available by or by phone: (North America) (International)

Yale Real Living Touchscreen Lever Installation and Programming Instructions (YRL220)

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 7 Mounting 7 Probe Use 8 Probe Wrap Use 9

1 Copyright 2015 Alarm.com. All rights reserved. Rev 3.4

ecobee 3 Quick Start Guide Installation Guide DRAFT

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

1 Copyright 2014 Alarm.com. All rights reserved. Rev 3.3

Instruction Manual Contact Sensor

Atomic Digital Wall Clock

BE1310 Visit Smart hub

ZTS-500US Z-Wave Smart Thermostat

Water Sensor. Model CFWS10

Wireless Driveway and Intruder Alert

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

Powerley Thermostat. Installation & Operation Guide

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

Transcription:

SP815 PET IMMUNE PIR MOTION DETECTOR The SP815 is a multifunction device with motion detector and temperature/humidity sensor. It uses Passive Infra-Red (PIR) technology to detect movement in a protected area by sensing the changes of thermal radiation caused by the moving body within or across the field of detection. Featuring dual PIR sensor designed with dual lens technology, this detector is immune to presence of pets in the home allowing your pet to move freely without causing false alarms. Auto Inclusion The detector supports Auto Inclusion feature where it will automatically enter Inclusion mode when first powered up after a factory reset. 1. Undo and remove the fixing screw located at the bottom of the PIR detector. Then carefully open the rear cover. This product is a Z-Wave Plus enabled device and is fully compatible with any Z-Wave enabled network. The device can be set up in a Z-Wave network to communicate directly with other end devices such as smartplugs, or to report directly to a Z-Wave controller (usually a gateway). When the motion detector is triggered, an alarm signal will be emitted to the controller and the controller, after receiving the signal, will perform certain action according to its settings. The product has a built in digital temperature sensor and humidity sensor to report environmental condition of the protected area to the controller. This product supports the S2 security protocol that uses encrypted Z-Wave Plus messages to communicate to other security-enabled Z-Wave Plus products. A security-enabled Z-Wave Plus Controller must be used in order to fully utilize the security features of this product. 2. Prepare the Z-wave Controller for Inclusion. 3. Insert the battery into the battery compartment. Note the correct polarity of battery as indicated. Product Overview 2 3 1 7 (rear cover removed) 4 5 6 4. The LED on the device will turn on. The duration of inclusion mode is 30 seconds. 5. The Inclusion process should be completed when the LED stops blinking. If you are connecting this unit to a Z-Wave Controller that utilizes the S2 security protocol, you may be asked by your controller to enter a 5-digit Device Specific Key (DSK) that is unique to each unit. This can be found in one of two places: - on the QR code label on the back of the unit - on the insert card inside the packaging. 1 Front Cover 2 Upper Lens 3 Lower Lens 4 Tamper button 5 Learn Key 6 Battery Compartment 7 LED indicator (hidden behind lens) Adding to Z-Wave Network If Auto Inclusion fails, refer to the Troubleshooting section regarding Manual Inclusion. Testing Warm-Up It will take approximately 1 minute for the detector to warm up after the battery is inserted. During this period the LED behind the lens will turn on. When the LED turns off, it implies warm-up procedure is complete and the detector is ready for detection. - This will not affect the Inclusion/Exclusion process. - After removing batteries, wait for 5 seconds to refit batteries. Quick Test

1. With the tamper switch not being pressed, the unit will enters Test mode to allow the user to test the device before it is mounted on the wall. 2. During Test mode, if movement is detected, the LED on the detector will illuminate implying the unit is working properly. Wait for 5 seconds before the next detection test. To exit the Test mode, simply press the Tamper switch for more than 10 seconds to enter Normal mode. Mounting the Detector Choosing a location The detector is suitable for mounting indoor in dry interior locations only. When considering a location for the detector the following points should be considered: - Do not locate the detector facing a window or where it is exposed to or facing direct sunlight. PIR detectors are not suitable for use in conservatories. - Do not locate the detector where it is exposed to ventilators. - Do not locate the detector directly above a heat source, (e.g. fire, radiator, boiler, etc). - Do not locate the detector in a position where it is subject to excessive vibration. Where possible, mount the detector in the corner of the room so that the logical path of an intruder would cut across the detection zone. PIR detectors respond more effectively to movement across the detection area than to movement directly towards the sensor. This product comes with pet immunity mechanism so that small pets or animals will not trigger the detector and cause false alarms. For pet immunity to be effective the pet s height and length must not exceed 60cm/90cm respectively to avoid triggering the detector. More Sensitive Less Sensitive The detector can be installed on a flat wall or in a corner as shown below. If the height of your pet exceeds 60cm, you can mount the PIR detector higher to prevent the PIR from being triggered by your pet. For example, if your pet is 70cm tall, you can mount the detector at the height of 2.1m instead of 2m as in regular condition, and the 70cm-tall pet should be able to stroll by without triggering the PIR. However, the same effect would also apply to human detection. So the PIR detector should not be mounted too high to affect its regular detection purpose. Installation 1. Remove the rear cover if it is fixed to the main body (refer to Figure 3). Use the rear cover as a template to mark the positions of the fixing holes on the wall. Carefully drill the required mounting holes on the wall. Flat wall mounting Corner mounting Mount the PIR detector at height of 2m. At this height, the detector will optimize the detection range of up to 12m with a field of view of 90.

Group 1 command: When the unit is powered up or the tamper is triggered, the unit will send a Notification Report to the node of Group 1. When the battery level of the unit drops to an unacceptable level, the unit will emit Battery report to the nodes of Group 1. When performing Factory Reset the unit will send Device Reset Locally Notification to the node of Group1. The unit will send Multilevel Sensor Report to the node of Group 1. Group 2: Association with 4 nodes (i.e. end devices such as smart plugs and other lighting controllers). This allows the detector to transfer commands directly to end devices without the participation of the controller. This has the effect that when the detector triggers, all devices associated with detector will be operated. Group 2 commands: When the detector is triggered, the unit will send BASIC_SET ON/OFF command which contains a value to the nodes of Group 2. 2. Fix the rear cover to the wall using the supplied screws and wall plugs. Do not over-tighten the fixing screws as this may distort or damage the cover. 3. Replace the main body to the rear cover and refit the fixing screw in the bottom of the PIR to secure the main body. Do not over-tighten the fixing screw as this may damage the casing. Operation When the detector is mounted on the wall i.e. tamper switch is pressed for more than 10 seconds, it will enter Normal mode. - Upon motion being detected, the detector will send an alert signal to the controller and enter sleep state for a preset period to conserve battery life. It will only be able to detect motion again when this preset period is up. This preset period is called Retrigger Interval and can be set by the controller. The default period is 3 minutes. - Unlike in Test mode, the red indicator LED on the detector will not illuminate when triggered in order to conserve battery life. The detector can provide periodic auto report measurement of temperature and humidity to the controller, or on demand when requested by the controller. In the event its front cover is removed, the tamper switch will be activated and the detector will send a Notification command to the controller. Maintenance Low Battery: Under low battery condition, the detector will remit RF signals to the Z-Wave controller to alert the user of its low battery condition. Replace the batteries as soon as possible. Programming Z-Wave Group The PIR detector supports 2 Association Groups: Group 1: Association with 1 Controller node. Z-Wave Plus Info Role Type Node Type Installer Icon User Icon Slave Sleeping Listening Z-Wave Plus node Association Command Class Group 1 1 2 4 Version Protocol Library Protocol Version 4.3D ( 6.71.01) Sensor Notification Device Type (Home Security) Max Node 3 (Slave_Enhance_232_Library) Manufacturer Manufacturer ID Product Type Product ID 0x0060 0x0001 0x0004 AGI (Association Group Information) Table Sensor Notification Device Type (Home Security) Group Profile Command Class & Command (List) N bytes Group Name(UTF-8) 1 General Battery Report, Device Reset Locally Notification, Notification Report Lifeline 2 Control Basic Set PIR Control Notification Event Type Event Event Parameter Length The power is applied for the first time 0x08 0x01 0x00 PIR Trigger ON 0x07 0x08 0x00 Event Parameter PIR Trigger OFF 0x07 0x00 0x01 0x08 Tamper switch being press more than 10 seconds 0x07 0x00 0x01 0x03

Tamper switch being press more than 10 seconds and released Battery Battery Report (value) Description 20~100 Battery Level % 0xFF Sensor Multilevel Get Sensor Type Scale Low Battery 0x07 0x03 0x00 0x01 0x00 Temperature ( ) 0x05 0x00 Humidity Command Classes The module supports Command Classes including COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_ASSOCIATION_V2* COMMAND_CLASS_ASSOCIATION_GRP_INFO* COMMAND_CLASS_TRANSPORT_SERVICE_V2 COMMAND_CLASS_VERSION_V2* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2* COMMAND_CLASS_DEVICE_RESET_LOCALLY* COMMAND_CLASS_POWERLEVEL* COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SUPERVISION* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2* COMMAND_CLASS_BATTERY * COMMAND_CLASS_NOTIFICATION_V4* COMMAND_CLASS_WAKE_UP* COMMAND_CLASS_CONFIGURATION* COMMAND_CLASS_SENSOR_MULTILEVEL* *Items marked an asterisk are secure command classes. Wakeup Command Class After it has been included into a Z-Wave network, the detector will go to sleep but will send a Wakeup Notification Command periodically at preset period to the controller. The Motion detector will stay awake for 10 seconds at least and then go back to sleep to conserve battery life. The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class based on the range values below: Minimum Wake Up Interval Maximum Wake Up Interval Default Wake Up Interval Wake Up Interval Step Seconds Z-Wave Configuration 600s (10 minutes) 86400s (1 day) 14400s (4 hours) 600s (10 minutes) 2. Re-trigger Interval Setting (for PIR sensor only) The parameter adjusts the sleep period after the detector has been triggered. No response will be made during this interval if a movement is presented. Longer re-trigger interval will result in longer battery life. 2 2 10~3600(sec) 180 3. Trigger Off Interval Setting This controls how long the connected lighting will stay on after the motion is detected This is useful for Group 2 associations where the detector is connected directly to another device such as smartplugs. 3 2 10~3600(sec) 15 Troubleshooting The table below lists the several steps involved when adding or removing the detector from the Z-Wave network. Action/Status Description LED indication No node ID Auto Inclusion Manual Inclusion Exclusion Factory Reset (This procedure should only be used when the controller is inoperable.) The Z-Wave Controller does not allocate a node ID to the unit. The power is applied for the first time and no node ID has been stored in the module, or after executing reset. 1. Put the Z-Wave Controller into inclusion mode. 2. Press the learn key 3 times within 1.5 seconds to put the unit into inclusion mode. 1. Put the Z-Wave Controller into exclusion mode. 2. Press the learn key 3 times within 1.5 seconds to put the unit into exclusion mode. 1. Press the learn key 3 times within 1.5 seconds to put the unit into exclusion mode. 2. Within 1 second of step 1, press the learn key again and hold for 5 seconds. 3. Node ID is excluded. The device reverts to factory default state. 2-second on, 2-second off For 2 minutes 2-second on, 2-second off For 2 minutes Failed or successful results in including/excluding the ID can be viewed on the Z-Wave Controller. If you are connecting this unit to a Z-wave Controller that utilizes the S2 security protocol, you may be asked by your controller to enter a 5 digit Device Specific Key (DSK) that is unique to each unit. This can be found in one of two places: - on the QR code label on the back of the unit - on the insert card inside the packaging Table below lists typical problems encountered: Symptom Possible Cause Recommendation LED on the detector does not turn on when battery is inserted Battery is not fitted properly or run out of battery power. Check if batteries are fitted or replace a new battery. 1. Temperature & Humidity Auto Report period setting 30mins (0 means not Auto 1 2 0~1440(sec) Report not set)

Cannot carry out inclusion and association Detector trigger by itself Z-Wave controller cannot communicate with the unit Specifications Device has been paired to other Z-Wave controller. Check if the detector is mounted above a radiator or heater Device is out of range. Battery CR123A battery x 1 Range Frequency Range PIR Warm Up Time PIR Detection Coverage Up to 100 meters line of sight EU: 868.42HMz, US: 908.42 MHz About 1 minute Up to 12m x 90 (at 2m mounting height & 25 C) PIR Pet Immunity Height 60cm; Length 90cm Temperature sensor range -10~40 ± 2 Humidity sensor range 0~80%RH ± 15%RH Specifications are subject to change without notice 1. Perform Exclusion from other controller first then carry out inclusion with new controller. 2. Perform Factory Reset on device and then carry out Inclusion with new controller. Remove the source of interference or reposition its mounting location 1. Relocate the controller closer to the unit. 2. Install a Z-Wave repeater such as smart plugs or other AC devices that can operate as a Repeater. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Industry Canada statement: This device complies with ISED s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d ISED applicables aux appareils radio exempts de licence. L exploitation est autorisée aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Radiation Exposure Statement: This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. WARNING: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: www.everspring.com 50 Sect. 1 Zhonghua Rd Tucheng NewTaipeiCity 236 Taiwan.. - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/tv technician for help.