Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Similar documents
Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

Technical Data Ducted Three Phase Split System Air Conditioner

Ducted Split System Air Conditioners Technical Data

Ducted Split System Air Conditioners Technical Data

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

EC Motor Fan Coil Units. IMD-Y Series l/s

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control

Packaged Air Conditioning Custom Build Solutions

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

EC Motor Fan Coil Units. IMDL-Y Series l/s

Cooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control

OPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. eco. series. Air Conditioning. Giving you complete control

Heat Pump Air Conditioning Systems

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

TOSHIBA AIR CONDITIONING

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Condensing Units CUS 15-60

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

REVERSE CYCLE DUCTED SPLIT SYSTEMS (ISDL/OSA c/w UC8/IUC) Installation & Maintenance

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

SAT-3 Room Temperature Controller

USER'S OPERATING INSTRUCTIONS

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Water Cooled Air Conditioners Applications Manual

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

ROOFTOP PACKAGED AIR CONDITIONERS

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Air Cooled Packaged Units

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

AQUASNAP JUNIOR 30RHV

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

PAJ3. Product Specifications

Ducted inverter reverse cycle air conditioning

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Modular Air Cooled Scroll Chillers

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

PRODUCT RANGE: ROOFTOP PACKAGE

LZA High efficiency air to water heat pumps with HP compressor

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

TOSHIBA AIR CONDITIONING

Hitachi Inverter Wall Split Air Conditioning

What do I need for my bedroom?

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

MAC N-407 Air-Cooled Chiller

Remote Air Cooled Condensers C2 Series

Commercial High-Efficiency Condensing Units

Now with WiFi as standard Find out more at

Product Brochure Smart Power. Low Profile Ducted

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

designed for air conditioning australian living

TECHNICAL SPECIFICATIONS

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

World s best airconditioning

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Hi - Wall Split Systems 12K - 18K - 24K

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

MACH N-407 Heat Pump Air-Cooled Chiller

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Leading edge Add-on cooling for ducted gas heating

Q Series. Inverter Split Systems

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

R4H4. Product Specifications

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Hansol Hi Wall Inverter Heat Pump

Braemar superior range of reverse cycle air conditioning

Product Brochure 2017

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

LZT High efficiency air to water heat pumps with E.V.I. compressors

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Transcription:

Ducted Split System Air Conditioner Technical Data ISD 87KYX / OSA 87RKSH SEPARABLE INDOOR UNIT Optional SAT-3 or TZT-100 Room Temperature Controller High Efficiency EC Motor Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 8.5 kw FEBRUARY 2017

ISD 87KYX / OSA 87RKSH DUCTED SPLIT SYSTEM AIR CONDITIONER GENERAL The ISD indoor unit, together with its associated OSA outdoor unit, provides a reverse cycle (heat pump) split system air conditioner designed and developed to comply with AS/NZS 3823 specified conditions. The system has been tested and proven for cooling operation in outdoor temperatures up to 52 C. APPLICATIONS These units have been specifically developed for air conditioning of light commercial and residential premises, e.g. offices, motels, shops and homes. Air Flow Selection If the air returning to the indoor coil is regularly expected to be above 50%RH, then the coil face velocity should be limited to be 2.5 m/s or less (for reference 2.0 m/s is marked on the graph below). High humidity levels can occur in tropical or subtropical conditions, and/or when heavily moisture laden fresh air is introduced. Consideration must always be given to selecting an air flow and face velocity that avoids water carry-over problems. Applications using full or high proportions of fresh air should be referred to your nearest temperzone sales office to establish the correct selection of units. FEATURES Refrigerant R410A. Each complete system uses refrigerant R410A which is deemed to have zero ozone depletion potential. User Friendly. The air conditioning system is available with an optional SAT-3 Controller. This thermostat has been designed to maintain a high level of comfort for room occupants. Emphasis has been placed on providing controls that are easy to use despite the sophisticated microprocessor system that runs it. Use of the Auto and Timer function settings allows you to "set it and forget it". Efficient. Indoor units include a high efficiency electronically commutated (EC) motor. Part load operation at low loads (75% airflow equates to 55% power use) using temperzone algorithms. Each outdoor unit incorporates a high efficiency rotary compressor. Heat exchange coils use inner grooved (rifled) tube for better heat transfer. Performance. A dynamically balanced forward curved fan with a multi-speed EC motor enables fine tuning of the indoor unit to match the supply air requirements. These EC motor fans have a fully integrated speed control that enables soft starting. Fan speed can be stepped to your own requirements or continuously variable using a 0 10V DC control signal. The system includes a temperature sensing head pressure control which enables the system to compensate for outdoor ambient temperatures below 20 C on cooling cycle, and above 15 C on heating cycle. Separable. The indoor units are separable for ease of installation through small man holes minimum 550 mm sq. clear aperture. It may be desireable in some applications to keep the two separate parts of the unit apart and joined by ducting, eg over a ceiling joist. A pair of the optional Spigot Plate Adaptors are available to facilitate this option. Quiet. Each integral high efficiency EC motor can vary from zero to full speed. This allows slow ramp up with no sudden noise change. The motor can be controlled to have the best air flow for the ducting and requirements as well as used for de-humidifying the space. The outdoor units' coil design permits low fan speeds and hence low noise levels. The compressor is isolated in a built-in, insulated compartment to minimise noise. The indoor unit is also insulated for noise attenuation. Slimline. The compact up-right design of the outdoor unit requires only a 100 mm gap on the coil side where installation is against a wall. Its slimline cabinet is particularly practical where there is restricted space, e.g. side access pathways, balconies, narrow ledges, etc. Durable. The outdoor coil fins are epoxy coated for extra protection in corrosive environments, e.g. salt laden sea air. The outdoor unit's cabinet is constructed from high grade galvanised steel - polyester powder coated (grey) for all weather protection (IP 44). External fasteners are stainless steel. Heat exchange coils comprise aluminium plate fins on mechanically expanded rifled copper tube. The indoor unit's cabinet is constructed from high grade galvanised steel and includes a plastic drain tray for complete corrosion resistance and a galvanised steel safety drain tray. Outdoor coils are protected with louvred anti-hail guards. Service Access. The indoor unit's built-in drain tray can be removed for ease of cleaning and service accessibility. Insulation. Closed cell foam insulation has been used in the indoor unit's cabinet to ensure no particles are introduced into the air stream. The insulation is foil faced and meets fire test standards AS 1530.3 (1989) and BS 476 parts 6 & 7. Control Option. Commissioning is made easier when the EC motor to be controlled variably (within a restricted range) by a 0 10 volt DC signal that can be supplied either by a BMS system, a sophisticated controller or temperzone's optional TZT-100 Controller. Self Diagnostics. The Unit Controller (UC8) has a display of LEDs to indicate faults and running conditions. A non-specific fault indicator is included for interface to external systems. OPTIONAL EQUIPMENT Outdoor Unit: 1. Anti-vibration mounts (rubber). 2. Drain connection - right angle. 3. Fault relay board (201-000-105). Indoor Unit: 1. temperzone SAT-3 or TZT-100 Room Temperature Controller. 2. Spring mounting kit. 3. Supply & return air spigots. 4. Spigot Plate Adaptors Double Inlet 350 dia. x2 (for use when separating indoor unit). 5. Filter Box c/w EU2/G2 rated filter. SAFETY FEATURES 1. HP and loss of refrigerant protection. 2. Anti-rapid cycle timer and internal overload for compressor protection. 3. Circuit breaker control circuits. 4. Time-and-temperature controlled electronic de-ice switch prevents icing up of the outdoor coil during heating cycle. 5. Frost protection on cooling cycle. 6. Sensor fault indication. 7. Compressor minimum run time to ensure oil return. COMPRESSOR Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimise vibration. REFRIGERATION PIPING Maximum line length is 40 m. Max. height separations between units are: Outdoor unit above indoor unit : 20 m Outdoor unit below indoor unit : 20 m. The OSA 87 is shipped from the factory with a charge of HFC-410A (R410A) refrigerant sufficient for a 10 m line length. Liquid and suction service valves are provided. Accurator expansion devices control the flow of refrigerant. The matched indoor unit is shipped with a holding charge of nitrogen. Both units have brazed pipe connections. WIRING The electrical supply required (including voltage fluctuation limits) is: 1 phase 200 252 V a.c. 50 Hz with neutral and earth. The compressor crankcase heater requires a 24 hour power supply. A control panel, with 24V control circiuit, located in each outdoor unit, is fully wired ready to accept the main power supply. Each system conforms with emission standards EN 55014-1, EN 60335-1 and EN 60335-2-40. The manufacturer operates a quality management system that conforms to AS/NZS ISO 9001:2008.

SAT-3 CONTROLLER (Optional) Features Summary Cool / Dry / Fan modes. Heat / Auto modes Auto / High / Medium / Low fan speed selection (customisable). Connects to either indoor unit or outdoor unit, ie IUC or UC8. Temperature setting range from 15 C 30 C (customisable). Room temperature display. Real time clock. 7 day timer up to four start and/or stops per day On demand countdown run timer, up to 3 hours. Auto-Restart after power failure. Continuous or Intermittent selection of fan run-on in dead zone. Backlit screen for ease of reading; changes colour for each mode. Soft touch tab keys Sleep function improves night time comfort and saves energy. Eco mode for ecomical operation. Quiet mode for outdoor unit when cooling. Battery backup (Lithium). Low voltage control cable. Colour: white and light grey (Keypad - green and blue). Optional: Remote air temperature sensor/s, Extra Wall Control plaque. Note: Not backwards compatible with units using SAT-2. PERFORMANCE DATA COOLING CAPACITY (kw) Total = Total Capacity (kw) Sens. = Sensible Capacity (kw) E.A.T. = Entering Air Temperature = Nominal Capacity (kw) Note: Capacities are gross and do not include allowance for fan motor heat loss. Capacities are for close coupled systems. Interconnecting pipework will reduce capacity. MODELS INDOOR INDOOR COIL OUTDOOR COIL ENTERING AIR TEMPERATURE C D.B. FAN E.A.T. Indoor Outdoor AIR D.B. W.B. 23 27 31 35 39 43 SPEED Unit Unit l/s C C Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. 21 15 8.3 6.5 8.2 6.5 7.9 6.4 7.6 6.2 7.1 5.8 6.5 5.4 23 17 8.8 6.4 8.7 6.4 8.5 6.3 8.1 6.1 7.6 5.8 6.9 5.3 ISD 87KYX / OSA 87RK HIGH 480 27 19 9.2 7.3 9.1 7.3 8.9 7.2 8.5 7.0 8.0 6.6 7.4 6.2 31 21 9.6 8.7 9.6 8.7 9.3 8.5 8.9 8.3 8.5 7.9 7.8 7.4 Indoor Air Flow Correction Factors @ nominal conditions Indoor Air Flow (%) -20% -10% Rated +10% Total Capacity 0.95 0.975 1.0 1.025 Sensible Capacity 0.89 0.950 1.0 1.050 HEATING CAPACITY (kw) G = Gross Heating Capacity kw, based on nominal air flow of 1300 l/s. N = Net Heating Capacity kw allowing for average defrost. = Nominal Capacity (kw) MODELS Indoor Outdoor Unit Unit ISD 87KYX / OSA 87RK INDOOR ENTERING AIR TEMP. C D.B. 15 20 25 OUTDOOR COIL ENTERING AIR TEMPERATURE (E.A.T.) C D.B. 5 3 1 1 3 5 7 9 G N G N G N G N G N G N G N G N 5.9 5.5 6.2 5.5 6.5 5.5 6.9 5.9 7.2 6.6 7.5 7.5 7.9 7.9 8.2 8.2 5.8 5.5 6.1 5.4 6.4 5.5 6.8 5.8 7.1 6.5 7.4 7.4 7.8 7.8 8.1 8.1 5.6 5.3 5.9 5.3 6.3 5.3 6.6 5.7 6.9 6.4 7.3 6.3 7.6 7.6 7.9 7.9

PERFORMANCE DATA AIR HANDLING Note: Airflows are for a dry coil. Reduce airflow by 10% in high moisture removal conditions. In a free blow application, beware of exceeding indoor fan motor's full load amp limit. Air flows given are for ISD units without filter installed. AVAILABLE EXTERNAL PRESSURE (Pa) l/s - Pa 200 4V 2.2A 1.2A 150 1.2A 7V 100 6V - - - - l/s - W 800 8V 7V 6V 8V 2.8A 2.0A 50 0.7A 4V 0 0.9A 1.7A 300 400 500 600 700 800 NOMINAL AIR VOLUME (l/s) 2.5 m/s Face Velocity 600 400 200 INPUT (W) If using EU-2 filter media, provide 0.08 m 2 face area per 100 l/s of airflow to maximise efficiency. Optional Filter Box c/w EU2/G2 rated media (clean): Coil Face Velocity (m/s) 1.5 2.0 2.5 Pressure Loss (Pa) 5 9 13 SOUND LEVELS Indoor Unit - Supply Air Outlet FAN SPEED 4V 6V 8V SWL db(a) 56 68 76 Sound Power Levels (SWL) Test Conditions: BS 848 PT2 1985. Installation Type A (free inlet and outlet). Direct method of measurement (reverberant room). Measured in decibels re 1 picowatt. OCTAVE BAND FREQUENCY Hz 125 250 500 1 k 2 k 4 k SOUND POWER LEVELS (SWL) db 58 54 54 50 48 44 68 65 65 64 60 58 73 73 71 72 69 68 Sound Pressure Levels (SPL) Within A Room Deduct the room absorption effect below from the Sound Power Levels (SWL) above to obtain Sound Pressure Levels within a room. Note: Occupant at least 1.5 m from sound source. ROOM TYPE SOFT MEDIUM HARD 125 4 3 0 250 8 7 1 OCTAVE BAND FREQ. Hz 500 1k ROOM ABSORPTION EFFECT 8 3 9 4 2k 9 4 4k 9 5 Outdoor Unit MODEL OSA 87 FAN SPEED LOW MED HIGH SWL db(a) 65 66 67 OCTAVE BAND FREQ. Hz 125 250 500 1 k 2 k 4 k SOUND POWER LEVELS db 69 66 62 61 55 50 70 66 63 61 56 51 70 68 64 63 57 52 SPL @ 3 m db(a) 49 50 51 OCTAVE BAND FREQ. Hz 125 250 500 1 k 2 k 4 k SOUND PRESSURE LEVELS db 53 50 46 45 39 34 54 55 47 45 40 35 54 52 48 47 41 36 Sound Pressure Level (SPL) in decibels re 20 µpa.

DIMENSIONS (mm) PROJECTION ISD 87KYX Indoor Unit 1077 OPTIONAL SPRING MTG CTRS 1014 FIXED MTG CTRS 45 840 REFRIG. CONN S Separable for ease of installation through small man holes minimum 550 mm sq. clear aperture Not to Scale COIL SIDE 500 MIN. CLEARANCE W 665 OPTIONAL SPRING OR FIXED MTG CENTRES Z Y X ELECTRICAL BOX 300 COIL SECTION 485 FAN SECTION 500 MIN. CLEARANCE FAN SIDE OPTIONAL SPIGOT PLATE ADAPTORS Ø350 mm (x2) ACCESS PANEL 838 908 FIXED MTG CTRS 971 OPTIONAL SPRING MTG CTRS 50 ELECTRICAL BOX 60 20 POINT LOADS (kg) W X Y Z 15 14 15 14 430 OA REFRIG. CONN S 262 355 Note: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. 1050 15 DRAIN 19 OD SAFETY DRAIN 19 OD 795 OA 50 OSA 87RKSH Outdoor Unit 100 MIN. CLEARANCE W Z 100 MIN. CLEARANCE Y X 750 MIN. CLEARANCE POINT LOADS (kg) W X Y Z 22 23 37 8 Recommended Connecting Pipe Sizes Suction : 16 mm OD Liquid : 10 mm OD 500 MIN. CLEARANCE ACCESS PANEL 765 25 DIA. DRAIN HOLES 183 72 714 MTG CTR 12 DIA. HOLE+SLOT 1085 25 DIA. DRAIN HOLES REFRIG. CONN S 375 MTG CTR 420 25 DIA. ELECTRIC CONDUIT HOLES 17 NOTE Specifications are subject to change without notice due to the manufacturer's ongoing research and development programme.

SPECIFICATIONS SYSTEM Indoor Unit : ISD 87KYX Sound Levels * 4 Operating Range (outdoor ambient) Finish Weight (net/shipping) kg Outdoor Unit : OSA 87RKSH Nominal Cooling Capacity * 1 kw 8.5 Net Cooling Capacity (MEPS) * 1 kw 8.3 EER / AEER (cooling) 3.25 / 3.21 Heating Capacity * 2 kw 7.8 COP / ACOP (heating) 3.25 / 3.23 Air Flow * 3 l/s 480 Power Source * 5 Compressor type Indoor Unit (SWL) 68 Outdoor Unit (SPL) 51 1 ph. 230 V a.c. 50 Hz Indoor Fan Maximum Current A 3 rotary Running Amps (Total System) A.1 Max. Running Amps (Total System) A 14.0 Refrigerant HFC-410A (R410A ) Maximum Vertical Separation m 20 Maximum Line Length m 40 Pipe Sizes (Suction/Liquid) mm OD 16 / 10 Cooling -10 C to 52 C Heating -15 C to 25 C Indoor Unit Outdoor Unit zinc galvanised steel grey polyester powder coat Indoor Unit 58 / 69 Outdoor Unit 90 / 103 Notes: * 1 Nominal Cooling Capacity (gross) at AS/NZS 3823 conditions: Indoor Entering Air Temperature 27 C D.B., 19 C W.B.; Outdoor Entering Air Temperature 35 C D.B. * 2 Heating Capacity at AS/NZS 3823 conditions: Indoor Entering Air Temperature 21 C D.B.; Outdoor Entering Air Temperature 7 C D.B., 6 C W.B. * 3 Supply air flow at Nominal Cooling Capacity conditions stated above. * 4 Sound Levels are measured at nominal cooling capacity conditions stated above. SPL measured at 3m from unit. * 5 Voltage fluctuation limits: Single phase systems 200 252 V. Available from temperzone limited Head Office, Auckland : 38 Tidal Rd, Mangere, N.Z. Private Bag 93303, Otahuhu, NEW ZEALAND. Email sales@temperzone.co.nz Website: www.temperzone.biz temperzone australia pty ltd Head Office, Sydney : 14 Carnagie Place, Blacktown, NSW 2148 PO Box 8064, Seven Hills West, NSW 2147, AUSTRALIA. Email sales@temperzone.com.au AUCKLAND SYDNEY Ph. 0-9-279 5250 Ph. (02) 8822-5700 Fax 0-9-275 5637 Fax (02) 8822-5701 WELLINGTON ADELAIDE Ph. 0-4-569 3262 Ph. (08) 85-21 Fax 0-4-566 6249 Fax (08) 85-28 CHRISTCHURCH SINGAPORE Ph. 0-3-379 3216 Ph. SNG 6733 4292 Fax 0-3-379 5956 Fax SNG 6235 7180 MELBOURNE Ph. (03) 8769-7600 Fax (03) 8769-7601 BRISBANE Ph. (07) 3308-8333 Fax (07) 3308-8330 NEWCASTLE Ph. (02) 4962-55 Fax (02) 4961-5101 PERTH Ph. (08) 6399-5900 Fax (08) 6399-5932 TOWNSVILLE Ph. (07) 4774-3506 Fax (07) 4774-3001 LAUNCESTON Ph. (03) 6331-4209 Fax (03) 6333-0224 02/17 Pamphlet No. 4051 temperzone limited 2017