Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

Similar documents
MACH N-407 Heat Pump Air-Cooled Chiller

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MAC N-407 Air-Cooled Chiller

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

PACKAGE AIR CONDITIONER

Advance Release September 2009

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

AIR COOLED PACKAGED CHILLER

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Concealed Ducted Split Series R-407C MBH

SKYPAK II, 3 Ton Series, gives you a

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

WCH5**4. Product Specifications

R4H4. Product Specifications

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

PAJ3. Product Specifications

SKYPAK II, 3 Ton Series, gives you a

Air-Cooled Condensing Units with Compact Screw Compressors

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

VariCool VAV Engineering Guide

R4H4. Product Specifications

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

CHAPTER 6 CONDENSING UNITS

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

C13-Series Engineering Guide

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SKYPAK II Heating & Cooling Self Contained Packages

N4H4. Product Specifications

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

VertiCool Aurora Engineering Guide

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

technical guide Water-Cooled Self-Contained Units

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

GUIDE SPECIFICATIONS AQUARIUS ii

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

MAC-120HE-03 Air-Cooled Chiller

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

WJH4 Product Specifications

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Water-Cooled Self-Contained Units

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

High Heat COP. High/Low Stage

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

.2 Section Waste Management and Disposal.

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Specifications and Performance S2H

Center Mount Unit Coolers

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Split System Heat Pump Product Data

SECTION WATER-SOURCE UNITARY HEAT PUMPS

A 14 SEER Heat Pump with R---410A Refrigerant Series

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

30GN FLOTRONIC II AIR-COOLED CHILLERS

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

CoolSpot Engineering Guide

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

Transcription:

Unit Dimension Unit Nomenclature DEHUMIDIFIER NOMENCLATURE R K D A - 0050 - C Z - M 4-8 UNIT VOLTAGE: 2: 240/1/60 5: 208-240/3/60 9: 480/3/60 8: 600/3/60 REFRIGEREANT R-404a MEDIUM TEMPERATURE SCROLL COMPRESSOR COPELAND COMPRESSOR COMPRESSOR HP: 0050 = 5 HP; 0075 = 7.5 HP ARENA DEHUMIDIFIER KOOL-AIR REFRIGERATION 2

MOISTURE REMOVAL IN Lb./hr RKDA-0050-CZ-M4 80 58,1 49,3 39,3 29,3 19,2 11,8 4,2 70 48,5 40,9 33,5 25,9 18,4 10,9 3,4 60 45,4 37,3 29,3 21,2 13,3 5,3 0,7 50 34,6 28,2 21,7 15,2 8,7 2,3 0,5 40 26,6 21,7 16,8 11,6 6,5 1,6 0,4 30 19,4 15,7 12,1 8,6 5,0 1,3 0,3 ADDED HEAT IN kw RKDA-0050-CZ-M4 80 28,6 25,8 21,4 18,1 14,7 11,3 7,7 70 25,0 21,9 18,9 15,7 12,7 9,7 6,6 60 20,3 17,9 15,4 12,7 10,3 7,9 5,4 50 16,1 14,0 11,8 10,0 7,9 5,8 3,9 40 13,1 11,5 9,7 8,2 6,3 4,9 3,3 30 10,0 8,8 7,4 6,1 4,6 3,0 2,0 MOISTURE REMOVAL IN Lb./hr RKDA-0075-CZ-M4 80 73,9 63,1 53,3 43,2 33,3 23,4 15,7 70 61,5 53,8 46,1 38,4 30,8 23,1 15,4 60 50,7 43,2 35,8 28,4 21,0 13,6 6,2 50 42,7 36,3 30,0 23,6 17,3 11,0 4,7 40 33,2 28,3 23,3 18,2 13,4 8,3 3,3 30 25,2 21,2 17,3 13,4 9,4 5,4 1,5 ADDED HEAT IN kw RKDA-0075-CZ-M4 80 35,6 32,0 28,4 25,1 21,3 17,8 14,4 70 31,6 28,5 25,2 22,2 19,1 15,7 12,7 60 25,0 22,2 19,4 17,0 14,3 11,5 9,1 50 19,4 16,3 15,4 13,7 11,5 9,7 7,9 40 16,1 14,3 12,4 10,9 9,1 7,4 5,4 30 12,1 10,9 9,7 8,5 7,4 6,1 4,9 Electrical Data CFM WEIGHT VOLTAGE RLA COMPRESSOR LRA HEATER WATT MOTOR AMP. MCA BREAKER RKDA-0050-CZ-M4-2 3000 668 208-230/1/60 31.1 175 70 10.5 49.4 80 A RKDA-0050-CZ-M4-5 3000 668 208-230/3/60 22.1 115 70 5.2 32.8 50 A RKDA-0050-CZ-M4-9 3000 668 460/3/60 9.6 63 70 2.6 14.6 25 A RKDA-0050-CZ-M4-8 3000 668 575/3/60 7.2 50 70 2.08 11.1 20 A RKDA-0075-CZ-M4-5 3500 725 208-230/3/60 32.1 195 90 5.2 45.3 75 A RKDA-0075-CZ-M4-9 3500 725 460/3/60 16.4 95 90 2.6 23.1 40 A RKDA-0075-CZ-M4-8 3500 725 575/3/60 12.9 80 90 2.08 18.2 30 A 3

Example: 1: Rate of infiltration (as determined by tests or calculations) = 30,000 cu. F./hr 2: Maximum outdoor design condition = 90 F DB, 76 F WB 3: Design indoor condition = 60 F 4: Number of spectators = 330 Step 1 Step 2 Step 3 Step 4 Find specific volume of outside air at 90 F DB, 76 F WB from psychrometric chart: 14.2cu. Ft./lb. Of dry air. Determine minimum temperature of building structures resulting from the ice surface radiation effect. This temperature is affected by the distance between structure and ice surface, building material (steel, wood, etc.) and the colour of this material. In existing buildings, this temperatures can be determined through tests. A safe structure temperature is 5 F lower than room temperature and this is the maximum dew point temperature recommended in order to prevent condensation. Example: 60 F - 5 F = 55 F Determine difference in grain outdoor, indoor with the psychometric chart (_ w): Outside air at 90 F DB, 76 F WB = 114 grains/lb. of dry air Ice rink at 55 F dew point = 64 grains/lb. of dry air Example: 114 grains/lb. of dry air - 64 grains/lb. of dry air = 50 grains/lb. of dry air Find moisture removal requirement (Wt): Wt = Wi + Wo (lb./hr.) Wi = (Q x Delta w) / (V x 7000) Wo = N x Wsp Where: Wt = Required total moisture removal (lb./hr) Wi = Required moisture removal due to infiltration (lb./hr) Wo = Required moisture removal of all spectators (lb./hr) Q = Air infiltration (cu. ft./hr) Delta w = Change in grain as per Step 3 (grains/lb. Of dry air) V = Specific volume of outdoor air as per Step 1 (cu.ft./lb. Dry air) N = Number of spectators Wsp = Moisture generation constant for each spectator = 0.15 lb./hr./spectator Calculation: Wi = (30,000 x 50) / (14.2 x 7000) = 15.0 lb/hr. Wo = 330 x 0.15 = 49.5 lb./hr Wt = 64.5 lb./hr Step 5 Step 6 Determine indoor relative humidity at given 60 F DB, 55 F dew point = 85 % RH (see psychrometric chart) In order to obtain good air distribution, at least two units should be used. Select units from Moisture Removal chart. (Two RKDA-0050-CZ-M4 have a capacity of 33.3 lb./hr each at the given operating condition.) 4

Unit Location Side view Top view 5

Standard feature Kool-Air dehumidifier casing is made of prepainted white galvanized steel and all drain pans are made of insulated heavy gauge stainless steel with 1 1/4 FPT connection. Compressors are scroll compressors with internal motor protection, centrifugal oil pump for long trouble free operation. All compressors will be supplied with a crankcase heater to prevent refrigerant migration. The piping of all units includes receiver, suction accumulator with boil-out coil, thermostatic expansion valve, liquid drier, sight glass, liquid solenoid valve three way valves and check valve for hot gas defrost. All the piping is made out of copper tube, brazed connections and has an operating charge of R-404a. Each system is tested for leaks and performances. Our receiver is sized to hold the whole refrigerant charge for easy service of the unit. Rotalock valves are supplied at outlet, to isolate the refrigerant charge. All units to operate on a pump down cycle for a liquid free starting of the compressor and to minimize refrigerant migration. Evaporator and condenser coils are made of smooth copper tube mechanically expanded into self spacing aluminum plate fin for permanent bond and maximum heat transfer. All evaporator coils are leak tested at 300 psig and condenser at 400 psig. The fans used on these units are forward curved statically and dynamically balanced centrifugal blower with ball bearings. Each blower is coupled with an electric motor with adjustable pulley on the motor. Motors are 2 horse power open drip proof with permanently lubricated ball bearing. Overload relays are provided for 3 phase protection. Controls are located in an accessible control panel. Control panel include compressor contactor, motor starter, high and low pressure switch and mounted humidistat. External pilot colored lights (blue, green and yellow) are supplied for a quick assessment of what stage the unit is working. The Kool-Air RKDA unit operate on hot gas defrost actuated from a demand defrost control. The demand defrost control shall verify every 45 minutes (adjustable) if ice is present on the evaporator. If there is ice formation, it will actuate a defrost cycle and it will stop when the evaporator is ice free. REFRIGERATION KOOL-AIR INC. Québec, Canada Tel: (450) 632-5775 Fax: (450) 632-7412 Email: kool-air@kool-air-inc.com Web site: www.kool-air-inc.com Due to Kool-Air policies to continuously improve the quality of its products, specifications are subject to change without notice