Oil Streak Streak Sensing Unit

Similar documents
SA-3841 User Manuel. 1U 4 Fans Unit with Thermostat Sensor. Version 1.1 Copyright All Rights Reserved

Sitron s CF Line of Flow Switch Monitors

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

Crimping Tools for Non - Insulated Terminals

Snifter. User Manual. Distributor

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

FlexSQUARE Square shaped beacons

Toll Free: Tel: Fax:

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

Snifter ATEX22 VERSION. User Manual. Distributor

Battery Interconnects

CAPACITIVE SENSORS. Reliable detection of objects and fi ll levels.

EC3-X33 Stand-alone Superheat Controller Technical Data

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Dräger Polytron 5700 IR Detection of flammable gases and vapours

NT DUAL CHANNEL DISPLAY. User Guide

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

B-40/B-41 Modulating Temperature Controller

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Electric Coils. Blower Coils. Product Information

Building and Characterizing 14GHz InGaAs Fiber Coupled Photodiodes

Retro-reflective Sensing range: 0mm to 2000mm

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

WIO200 Water in oil sensor

TraceNet TM TCM2 CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

WATER SUPPLY HOOK-UP DISPLAY 0-WSH-1

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Centro-Matic Automated Lubrication Systems System Controls

HART XL High Sensitivity Smoke Detection

Ramsey Motion Monitoring Systems

SCC Inc. FLMTR Series Natural Gas Flow Meter Kits for Boiler Commissioning or Flow Totalization. Technical Instructions

y Small dimensions. Easy to install in refrigerated counters or cold rooms

CHECKFIRE 210 Detection and Actuation System

LaserFOCUS VLF-250 Engineering Specification

Using the DewTrak II Dew Point/ Humidity Transmitter

Crimping Tools. For Non-Insulated Terminals. For Pre-Insulated Terminals. For Closed End Connectors. Tool-Terminals Cross Reference.

Event Detection System (EDS)

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

SS-100. Pyrometer. Temperature Range: 800~2400

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter

MMEngineering. Suction lifter. Lightning fast suction for lifting and moving. with only on vaccum line. Suction lifters Vacuum-operated

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Software Version 2.01 LEVEL MONITOR MODEL 220

Fan speed controller Type Saginomiya XGE

Instruction Manual Model Backup Switch, 1 for 8

INVITATION TO TENDER ITT NO. PS KILLARNEY COMMUNITY CENTRE ENERGY UPGRADE ADDENDUM NO. 2

Chlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253

Weight / 003 -Z M5 (SUCOFEED ¼ HF) bulk 10 pcs g / 5.25 oz.

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

Sintrol Snifter A2 EX. Manual. Version 1.2.3

M7100 Pressure Transducer

TECHNICAL DATA SHEETS

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

Pressure Transducers Ultrahigh-Purity

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

Roto-Jet I & II Tube Cleaning Systems

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

M1000 Alarm Annunciator

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

OPTISENS TUR 2000 Technical Datasheet

Vacuum generators VADM/VADMI

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Humidifiers. Model 400/400M Humidifiers NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO.

Dräger Polytron 8310 IR Detection of flammable gases and vapour

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

Rogue 4 specializes in extreme output high performance LED lighting.

F3UV. Monitoring output state of UV (ultraviolet light)/illumination light source. Ultraviolet power monitor/illumination monitor.

SmartAlarm Annunciator

AS950 PORTABLE SAMPLERS

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

Danfoss gas detection Controller unit

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Arc Fault Protection System D1000

Multifunctional Gate Box MGB. More than safety.

Brivis Touch Controller. Installer Manual

VADA - Rain2Main Automatic Rainwater Controller

Accessories. Safety Shut-off Valves. Certifications. Accessories. ASV375NT Safety Shut-off Valve. Combination Gas Control/Valve

Annunciator Unit SACO 16 D1. Product Guide

V-PIX Vision Bar LED Pixel Bar Light. User Manual KEEP THIS MANUAL FOR FURTURE NEEDS

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

SECTION AUTOMATIC TRANSFER SWITCHES

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Transcription:

Oil Streak Streak Sensing Unit GENERAL The Streak Sensing Unit system detects and monitors lubrication for high-speed spindles and other applications requiring accurate oil deliveries. The Streak Sensing Unit is versatile and allows multiple configurations that enable systems to be designed to suit various applications. Refer to the following documents: Operators Manual: 35651_Oil Streak Sensing Unit_2012_1_GB Datasheet: 35720_Oil Streak Generating Unit_2012_1_GB Datasheet: 35721_Oil Streak Mixing Unit_2012_1_GB Datasheet: 35465_SureFire PDI Lubricator_2012_1_GB APPLICATION The Streak Sensing Unit is designed to detect oil traces in the air tube, down to 5mm 3 /min. The product has been designed using a primary/secondary concept. The primary sensor, while monitoring a single tail tube, also incorporates a 4-segment LED display, 3 soft keys for programming and configuring, and an M12 electrical connector for power supply and fault alarm output. The secondary sensors may be piggybacked to the primary sensor, up to a maximum of 3, or may be remotely connected via an interconnecting cable. One secondary sensor can monitor one tail tube. The sensors are designed for either 4mm or 6mm tube. The sensor works by detecting and counting pulses, generated from the oil particles in the air stream passing through optical components of the sensor. The count value is checked periodically and compared with the calibrated value. Should the count value fall below a certain predetermined point, then the unit will initiate an alarm. The calibrated value is the value as determined by a calibration sequence which is initiated by the user, on initial setup, and once a steady-state stream of oil can be clearly seen in the tubes. Various other parameters may be configured through the menu on the primary sensor. The sensors may be sold separately, or as a kit, or indeed may come incorporated in an Air-Oil spindle lubrication system panel. On such a panel, the sensors have been designed to interface directly with the SureFire Lubricator with a controller. page 1-6

TECHNICAL DATA Operating Voltage :... 10 to 30 V DC Operating Temperature :... 0 o C to 50 o C Certification :... CE Fault Alarm Relay Contact Rating :... 0.13 A, 24 V IP Enclosure Rating: without enclosure :... IP54 in Enclosure :... IP66 Weight :... primary: 50 g, secondary: 40 g Materials : Main body... Nylon 66 (black) Cover... Zinc plated steel Fastners... Zinc plated steel Tube fittings... Nickel plated Brass M12 connector... Nickel plated Brass Power Consumption :... primary: 1.5 W, secondary: 0.5 W Overall Dimensions :... 262mm x 372mm x 190mm HOW TO ORDER Name Description Part # Streak Sensing Unit Primary 4 mm tubing OSS-M4 6 mm tubing OSS-M6 Secondary 4 mm tubing OSS-S4 6 mm tubing OSS-S6 Streak Sensing Unit: 2-way assembly, 4 mm tubing (1 primary & 1 secondary) OSS-B42 Primary & Secondary Sensors 3-way assembly, 4 mm tubing (1 primary & 2 secondary) OSS-B43 (Complete assembly w/brackets) 4-way assembly, 4 mm tubing (1 primary & 3 secondary) OSS-B44 2-way assembly, 6 mm tubing (1 primary & 1 secondary) 3-way assembly, 6 mm tubing (1 primary & 2 secondary) 4-way assembly, 6 mm tubing (1 primary & 3 secondary) When ordering, specify by name, description and part number, e.g. Streak Sensing Unit, Primary, 4 mm tubing, Part #0SS-M4. OSS-B62 OSS-B63 OSS-B64 ATTENTION The Streak Sensing Unit is for indoor use only. page 2-6

STREAK SENSING UNIT AT A GLANCE Primary Sensor 4-Segment LED Display Membrane Keys (3) Secondary Sensor Connector M 12 Connector LED Indicators (Red & Green) Nylon Housing Zinc Plated Steel Cover Data Label Tube Clamp Fitting Mounting Foot (2) Secondary Sensor LED Indicators (Red & Green) Data Label Sensor Connector (Female) Sensor Interconnector (Male) Zinc Plated Steel Cover Nylon Housing Tube Clamp Fitting Mounting Foot (2) page 3-6

ACCESSORIES Description Part # Mounting Bracket 2-way, complete with mounting fastners OSS-B2 3-way, complete with mounting fastners 4-way, complete with mounting fastners OSS-B3 OSS-B4 Electrical Cord M 12, straight, 2 m long (connects to sensor) M124S02U34 M 12, 90 o, 2 m long (connects to sensor) M 12, straight, 5 m long (connects to sensor) M 12, 90 o, 5 m long (connects to sensor) M 12, straight, 10 m long (connects to sensor) M 12, 90 o, 10 m long (connects to sensor) M124A02U34 M124S05U34 M124A05U34 M124S10U34 M124A10U34 Electrical Cord Extension M 12, straight, 1 m long (connects to sensor & SureFire) M124SS01EXT M 12 Connector (no cable supplied) M 12, straight, 3 m long (connects to sensor & SureFire) M 12, straight, 5 m long (connects to sensor & SureFire) M 12, straight, 10 m long (connects to sensor & SureFire) Field-wireable, straight (connects to sensor) 23694 M124SS03EXT M124SS05EXT M124SS10EXT Field-wireable, angled (connects to sensor) 23694-1 Field-wireable, straight (connects to SureFire) 23846 Field-wireable, angle (connects to SureFire) 23846-1 OSS Tube Size Conversion Kit Convert sensor from 6 mm to 4 mm OSS-K4 Convert sensor from 4 mm to 6 mm OSS-K6 IP 66 Enclosures 4-way enclosure for 4 mm tubing OSS-E4 Complete Enclosure Assemblies 4-way enclosure for 6 mm tubing 1-way enclosure for 4 mm tubing (c/w primary sensor & 5 m trailing cable) 2-way enclosure for 4 mm tubing (c/w primary & secondary 3-way enclosure for 4 mm tubing (c/w primary & 2 secondary 4-way enclosure for 4 mm tubing (c/w primary & 3 secondary 1-way enclosure for 6 mm tubing (c/w primary sensor & 5 m trailing cable) 2-way enclosure for 6 mm tubing (c/w primary & secondary 3-way enclosure for 6 mm tubing (c/w primary & 2 secondary 4-way enclosure for 6 mm tubing (c/w primary & 3 secondary OSS-E6 OSS-E41 OSS-E42 OSS-E43 OSS-E44 OSS-E61 OSS-E62 OSS-E63 OSS-E64 page 4-6

DIMENSIONS (mm) Sensors Primary Sensor IP Enclosure page 5-6

page 6-6