Single Zone Air Conditioner SVC MANUAL (Exploded View)

Similar documents
Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

SVC Manual(Exploded View)

LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)

Room Air Conditioner SVC MANUAL(Exploded View)

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Air Conditioner SVC MANUAL(Exploded View)

Ductless Split Systems Concealed Duct Heat Pumps

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)

SVC Manual(Exploded View)

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Ductless Split Systems Ceiling Cassette Heat Pumps

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

DESIGN & TECHNICAL MANUAL

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Multi Inverter Air Conditioning Condensing Units - Summary

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

DESIGN & TECHNICAL MANUAL

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

Ductless Split Systems Wall-mounted, Multizone Heat Pump

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

DESIGN & TECHNICAL MANUAL

DUCTLESS ROOM AIR CONDITIONERS

Room Air Conditioner SVC MANUAL(Exploded View)

Samsung 360 Cassette, Single Zone, Split System

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

High Heat COP. High/Low Stage

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Digital Inverter 4 series 8 & 10HP

Multi V Air Conditioner SVC MANUAL(Exploded View)

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)


SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

SUBMITTAL DATA: PVA-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

Multi V Air Conditioner SVC MANUAL(Exploded View)

SUBMITTAL DATA: PEAD-A30AA7 & PUZ-A30NHA7(-BS) 30,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A30NHA7

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

ASU18RLF ASU24RLF AOU18RLXFW1 AOU24RLXFW1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

Multi V Air Conditioner SVC MANUAL(Exploded View)

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

TABLE OF CONTENTS. Air Conditioner

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

FLOOR CONSOLE / UNDER CEILING DUAL type

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

Breeze A revolution in room cooling.

J SERIES DUCTLESS SPLIT SYSTEMS

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

ASU18RLF ASU24RLF AOU18RLXFWH AOU24RLXFWH CONTENTS WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

TECHNICAL DATA & SERVICE MANUAL

DESIGN & TECHNICAL MANUAL

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

SERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

Multi V Air Conditioner SVC MANUAL(Exploded View)

Wall Mounted Air Conditioner

LG Electronics AE Company, Commercial Air Conditioning

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

Multi V Air Conditioner SVC MANUAL(Exploded View)

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

DESIGN & TECHNICAL MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

LG Electronics AE Company, Commercial Air Conditioning

Multi V Air Conditioner SVC MANUAL(Exploded View)

Transcription:

Single Zone Air Conditioner SVC MANUAL (Exploded View) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. MODEL: MR36UY3J 960-920-10

1. Specification Indoor Unit MD36Y3J MC36Y3J Cooling Min. ~ Rated ~ Max. kw 4.7~10.5~12.1 4.10 ~ 10.5 ~ 12.3 Capacity Min. ~ Rated ~ Max. Btu/h 16,200 ~ 36,000 ~ 41,400 14,000 ~ 36,000 ~ 42,000 Heating Min. ~ Rated ~ Max. kw 5.2 ~ 11.7 ~ 13.4 4.25 ~ 11.7 ~ 13.1 Min. ~ Rated ~ Max. Btu/h 18,000 ~ 40,000 ~ 46,000 14,500 ~ 40,000 ~ 45,000 Power Input Cooling Rated kw 2.97 2.97 Heating Rated kw 3.36 3.2 EER / COP Btu/h W 12.1/- 13.5 / - SEER / HSPF Btu/h W 17.6 / 9.2 19.0 / 9.5 Model Name MR36UY3J Power Supply V, Ø, Hz 208-230 / 1 / 60 Starting Current Cooling Max. A - Heating Max. A - Wiring Connections Power Supply Cable (included Earth) No. x mm 2 (AWG) 3C x 5.0 (10) Casing Color - Warm Gray Dimensions W x H x D mm 950 1,380 330 W x H x D inch 37-13/32 54-11/32 13 Net Weight kg (lbs) 92.0 (202.8) Type - Twin Rotary Compressor Model Model x No. GPT442MBA x 1 Motor type - BLDC Motor Output W x No. 4,000 x 1 Type - R410A Precharged Amount g (oz) 3,400 (119.9) Refrigerant Chargeless-Pipe Length m (ft) 7.5 (24.6) Additional Charging Volume g/m (oz/ft) 40 (0.43) Control - Electronic Expansion Valve Refrigerant Oil Type - FVC68D Charged volume cc x No. 1,300 x 1 Heat Exchanger (Row x Column x Fins per inch) x No. - (2 x 32 x 14) x 2 Fan Type - Propeller Air Flow Rate m 3 /min(ft 3 /min) x No. 55(1942) 2 Fan Motor Type BLDC Output W x No. 124.0 x 2 Sound Pressure Level Cooling Rated db(a) 52 Heating Rated db(a) 54 Sound Power Level Rated db(a) 67 Piping Connections Liquid Outer Dia. mm(inch) Ø 9.52 (3/8) Gas Outer Dia. mm(inch) Ø 15.88 (5/8) Piping Length Max. m (ft) 75 (246.1) Maximum Height Difference Outdoor Unit ~ Indoor Unit Max. m (ft) 30 (98.4) Operation Range (Outdoor Temperature) Cooling Min. ~ Max. DB ( DB) -15 (5.0) ~ 48 (118.4) Heating Min. ~ Max. WB ( WB) -18 (-0.4) ~ 18 (64.4) Note: 1. All data are based on the following conditions: - Cooling Temperature : Indoor 26.7 (80 ) DB / 19.4 (67 ) WB Outdoor 35 (95 ) DB / 23.9 (75 ) WB - Heating Temperature : Indoor 21.1 (70 ) DB / 15.6 (60 ) WB Outdoor 8.33 (47 ) DB / 6.11 (43 ) WB - Piping Length : Interconnected Pipe Length = 7.5m - Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero. 2. Wiring cable size must comply with the applicable local and national code. 3. Due to our policy of innovation some specifications may be changed without notification. 4. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased (maximum 3dB(A)) owing to ambient conditions during operation. - 2 -

2. Piping Diagrams Refrigerant Flow Cooling Heating Outdoor Unit Heat exchanger Outlet temperature Heat exchanger inlet air temperature Ø9.52 Flare Connection Heat exchanger temperature M Strainer Strainer Electronic Expansion Valve Pressure Sensor Ø15.88 Flare Connection Accumulator 4 way Valve discharge temperature suction temperature Inverter Compressor Description suction temperature discharge temperature Heat exchanger inlet air temperature Sen for Heat exchanger inlet air temperature Heat exchanger temperature Pressure Sensor PCB Connector CN_TH3 CN_TH2 CN_TH4 P-SENSOR(H) - 3 -

3. Wiring Diagrams MAIN PCB CN_MOTOR1 CN_MOTOR2 CN_N/F CN_EEV1 CN_4WAY CN_COOLING CN_TH2 P_SENSOR (H)-RD CN_TH3 CN_TH4-4 -

4. Exploded View 549610 554030A 552111 237204 435300 559010 546810A 552115 352111 546810B 559010 435512 554030B 649950 263230C Air / Cond-Out 55211G 661400 548490 437212 349480 237202 Cond-Mid 263230A 261704 268711A 552200 W4810 W620 0 W52240 552117 237205 435301 W0FZZ 263230B Suction / Discharge pipe W6640 552202 561410 552116 447910 148000 165010 Pressure sensor 552560 135500 552203A W6631 349480 552203B W4986A 435301 437211 137213 435513 554160 W4986B 430410 152503 550140B Location No. Description Sensor Information Housing Color 263230A Thermistor S2(CN-TH4) Cond-Mid Blue 263230B Thermistor S4/S3(CN-TH3) Suction /Discharge pipe Red 263230C Thermistor S6/S5(CN-TH2) Air / Cond-Out White 165010 Pressure sensor(p-sensor (H)-RD) Pressure Sensor Red - 5 -

Model: MR36UY3J Loc No. Description Friedrich Part # 548490 Accumulator Assembly 67600102 447910 Barrier Assembly, Outdoor 67600303 430410 Base Assembly, Outdoor 67600600 W4810 Bracket Assembly 67600706 549610 Bracket Assembly, Motor(Outdoor) 67600709 649950 Case Assembly, Control(Outdoor) 67600927 661400 Coil 67601100 554160 Compressor Set, Korea 67601203 554030A Condenser Assembly, First 67601309 554030B Condenser Assembly, First 67601310 W6640 Connector, Terminal Block 67601400 135500 Cover 67601503 435512 Cover Assembly, Top(Outdoor) 67601612 435513 Cover Assembly, Tubing 67601615 550140B Damper, Compressor 67601701 561410 Drawing, Assembly 67601904 559010 Fan, Propeller 67602117 W6200 Filter, AC Line 67602203 W0FZZ Fuse, Time Delay 67602301 W4986A Gasket 67602409 W4986B Gasket 67602410 435301 Grille, Discharge 67602511 435300 Grille, Rear 67602516 W6631 Harness, Multi 67602600 546810B Motor Assembly, DC 67603303 546810A Motor Assembly, DC, Indoor 67603308 546810A Motor Assembly, DC, Outdoor 67603314 552560 Muffler 67603401 152503 Nipple, Drain 67603500 349480 Orifice 67603602 437211 Panel Assembly, Front(Outdoor) 67603805 437212 Panel Assembly, Rear(Outdoor) 67603817 137213 Panel Assembly, Side 67603843 237202 Panel, Front 67603834 237205 Panel, Rear 67603839 237204 Panel, Side 67603841 268711A PCB Assembly 67603902 165010 Sensor, Pressure 67607400 W52240 Strainer 67607500 148000 Supporter 67604602 263230C Thermistor Assembly, NTC 67604804 263230A Thermistor Assembly, NTC 67604812 263230B Thermistor Assembly, NTC 67604814 261704 Transformer,Linear 67604900 352111 Tube Assembly 67605000 552111 Tube Assembly,Capillary 67605102 55211G Tube Assembly,Expansion 67605900 552115 Tube Assembly,Menifold(Outdoor) 67606011 552116 Tube Assembly,Reverse 67606109 552117 Tube Assembly,Suction(Outdoor) 67606200 552200 Valve,Expansion Body 67606303 552202 Valve,Reverse 67606400 552203A Valve,Service 67606514 552203B Valve,Service 67606511

Friedrich Air Conditioning Co. I 10001 Reunion Place, Suite 500 I San Antonio, TX 78216 I 877.599.5665 www.friedrich.com