BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

Similar documents
Integrated Heat Pump Water Heater

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

50A KP 70A KP 90A KP 120A KP 150A KP 210A

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Advance Split

The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future!

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AQUAHEAT ADVANCE SPLIT

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

S-Therm Air to Water Heat Pumps

HERO SERIES-DC INVERTER HEAT PUMPS

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Heat Pumps COMFORT NEED IT. When You

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

LZA High efficiency air to water heat pumps with HP compressor

PAC BT LOW TEMPERATURE HEAT PUMP

PRODUCT GUIDE

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Neosys Product catalogue

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Do you want a versatile solution

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

DES IGN I T ALI A N O

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

LZT High efficiency air to water heat pumps with E.V.I. compressors

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

NATURAL HEATING MACHINE

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Product Line Introduction. Karl Zhang Technical support engineer

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

DESIGN ITALIANO


WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Air cooled industrial chillers

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

HT V2 HT Split

THE HEAT PUMP CHOICE OF PROFESSIONALS

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

Air Cooled Scroll Chiller

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Blue Box Epsilon Echos +

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

CHAPTER 6 CONDENSING UNITS

HYDRONIC RESIDENTIAL

SWIMMING POOL HEAT PUMPS

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

WZH Ground source heat pumps

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Air to water Heat Pump System

AIR SOURCE HEAT PUMPS DUAL CLIMA

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

DESIGN & TECHNICAL MANUAL

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Split Type System. Air to Water Heat Pump

Transcription:

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

1 Enjoy comfortable life with BLUEWAY DC Inverter Air to Water Heat Pump is an innovative system of house heating, domestic hot water and even space cooling, with advanced DC inverter technology, saving 40% electricity than normal on/off heat pump in practical operation. It offers the users with maximum comfort the whole year through. It can work with solar, boiler or electric heater according to practical condition of the heating system. Features Inverter technology ensures super efficient performance and low energy consumption 5 modes: heating only, heating+hot water, hot water only, cooling only, cooling+hot water. With control output for 3 way valve With Intelligent temperature compensation function, the water setting temperature adjusts automatically as the house s heat loss changes Automatically variable fan speed in 3 grades to optimize heating efficiency Can work with room thermostat Can work with auxiliary heater Low ambient design, the units can work at low ambient conditions up to -20

Enjoy comfortable life with 2 SUPER PERFORMANCE THANKS TO THE INVERTER TECHNOLOGY The high COP (coefficient of performance) of the unit is largely attributed to Buleway s inverter technology. An integrated frequency-converter adjusts the rotational speed of the compressor to suit the heating demand. Therefore, the system seldom operates at full capacity and the customer only pays for the energy which they actually need. BLUEWAY INVERTER AIR-to-WATER HEAT PUMPS BENEFITS BOTH NEW CONSTRUCTION AND RETROFIT INSTALLATIONS

3 Enjoy comfortable life with DC INVERTER Split type heat pump BLUEWAY Split Type Inverter Air to Water Heat Pump has an outdoor unit and an indoor unit. The compressor is located in the outdoor unit and the hydronic components are located in the indoor unit. The outdoor unit and indoor unit are connected with refrigerant piping. The compact outdoor unit extracts heat from the outside ambient air and transfers it inside through refrigerant piping to supply heating. Free Standing Indoor Unit Wall Mounted Indoor Unit Outdoor Unit FEATURES Split design with water system indoor, preventing water frozen problem Aviation plug for wire connection between indoor unit and outdoor unit, simplifies installation and avoids mistakes Allows absence of buffer tank With water pressure gauge in indoor unit

Enjoy comfortable life with 4 APPLICATIONS Heating+ Cooling+ Domestic Hot Water Heating using under floor heating loops, Low temperature radiators and fan coil units. Cooling using only fan coil units. Hot water for domestic use is delivered by the domestic hot water tank connected to the indoor unit. APPLICATION R-410A REFRIGERANT PIPING Between outdoor unit and indoor unit H2O PIPING INSTALLER'S ADVANTAGES Between indoor unit and indoor heating terminals ( under floor heater, radiator, domestic hot water tank, fan coil unit) No extra insulation of H2O piping required to protect from freezing up Refrigerant out Refrigerant in Water in Water out Water in Demestic hot water Water out Radiators Fan Coil Under-floor heating

5 Enjoy comfortable life with KEY COMPONENTS INDOOR UNIT STANDARD UNIT COMPOSITION SUS 316 OF BRAZED PLATE HEAT EXCHANGER MOTORIZED 3-WAY VALVE (OPTIONAL) CIRCULATION WATER PUMP EXPANSION VESSEL BUFFER TANK WITH ELECTRIC BACK UP HEATER ELEMENT SAFETY VALVE AIR PURGE VALVE FULL SEALED CONTROL BOX WITH WATER PROOF LEVEL IPX5 INTELLIGENT USER INTERFACE WATER PRESSURE GUAGE RERIGERANT PRESSURE GUAGE FLOW SWITCH FOR WATER FLOW PROTECTION BASE FRAME AND EXTERNAL FRAME MADE OF POWDER COADTED STEEL 1 Refrigerant gas connection(3/4) 2 Refrigerant liquid connection(1/2) 3 Air conditioner water outlet(g1) 4 Air conditioner water return(g1) 5 Sanitary hot water outlet(g1) 6 Sanitary hot water return(g1) 7 Y style water filter 8 Non return valve 9 Control panel 10 Electronic 3 way valve 11 Pressure gauge(refrigerant) 12 Water pump 13 Expansion tank 14 Flow switch 15 Electric compartment 16 Pressure relief valve 17 Air purge valve 18 Buffer Tank with back-up heating elements 19 Plate Heat Exchanger OUTDOOR UNIT STANDARD UNIT COMPOSITION INVERTER ROTARY OR SCROLL COMPRESSOR WITH CRANKCASE HEATER AND THERMAL PROTECTION ECO-FRIENDLY HIGH EFFICIENCY R410A REFRIGERANT AIR HEAT EXCHANGER MADE OF INNER GROOVED COPPER TUBES AND BLUE HYDRAULIC COATED ALLUMINUM FINS, FOR HIGH EFFICENCY AND CORROSION RESISTANCE FACTORY WIRED AMBIENT AIR TEMPERATURE SENSOR HEAVY GUAGE GALVANIZED STEEL CABIENT WITH EPOXY POWDER PAINTING FOR LONG LASTING OUTDOOR LIFE SPAN ELECTRIC EXPANSION VALVE AIR PURGE VALVE AUTOMATIC INTELLIGENT DEFROSTING BOTTOM PLATE HEATER TO KEEP THE BASE FREE OF ICE AND THE DRAIN HOLES OPEN HIGH PRESSURE AND LOW PRESSURE PRETECTION

Enjoy comfortable life with 6 SPECIFICATION DATAS Model Split DC Inverter Air To Water Heat Pump DHP-09S DHP-12S DHP-15S DHP-15ST DHP-18ST DHP-24ST DHP-30ST HP 3 4 5 5 6 8 10 Power supply V/Ph/Hz 200-240V/1Ph/50Hz 380-415V/3Ph/50Hz Heating capacity kw 9 12.0 15.0 15.0 18.0 24.0 30.0 +7 / 35 floor heating Power input kw 2.1 2.70 3.50 3.40 4.30 5.60 7.30 COP - 4.2 4.4 4.3 4.4 4.2 4.3 4.1 Heating capacity kw 6.8 11.3 12.7 12.7 15.3 21.7 25.6 +2 / 35 floor heating Power input kw 2.1 3.40 3.85 3.80 4.60 6.60 8.20 COP - 3.2 3.30 3.30 3.30 3.30 3.30 3.10 Cooling capacity kw 6 10.0 11.0 11.0 13.3 18.9 22.3-7 / 35 floor heating Power input kw 2.4 3.85 4.40 4.40 5.40 7.60 9.20 EER - 2.5 2.60 2.50 2.50 2.45 2.50 2.40 Heating capacity kw 7.8 10.3 13.0 13.0 15.3 20.6 25.5 +7 / 45 radiators Power input kw 2.4 3.30 4.00 4.00 4.80 6.30 8.20 COP - 3.2 3.10 3.30 3.30 3.20 3.30 3.10 Heating capacity kw 7.6 10.1 13.0 13.0 15.2 20.6 25.3-7 / 45 radiators Power input kw 3.4 5.00 6.20 6.20 7.20 9.80 12.60 COP - 2.2 2.00 2.10 2.10 2.10 2.10 2.00 Cooling capacity kw 7 10.0 11.8 11.8 14.5 20.0 25.0 +35 / 7 fan coil Power input kw 2.6 3.60 4.50 4.50 5.80 7.10 10.00 EER - 2.7 2.80 2.60 2.60 2.50 2.80 2.50 Noise level DB(A) 52 53 55 55 55 56 56 Rated outlet water temp. Max outlet water temp. Ambient temperature range 7~55 60-20~43 Rated water flow rate L/S 0.43 0.57 0.72 0.72 0.86 1.15 1.43 Rated pressure drop kpa 30 40 45 45 45 40 47 Refrigerant Bar 44 44 44 44 44 44 44 Max. Working Pressure Water Bar 7 7 7 7 7 7 7 Water connection inch 1" 1" 1" 1" 1" 1-1/4" 1-1/4" Controller - Micro processor based digital wire controller with LCD display External cabinet - Galvanized steel with powder coating Make - Mitsubishi Hitachi Type - Rotary Scroll Compressor Nos. - 1 1 1 1 1 1 1 Refrigerant Refrigerant amount Kg 1.45 1.9 2.5 R410A 2.5 2.6 4.2 4.5 Water heat exchanger Type - Brazed plate heat exchanger Materials - SUS 316 Copper pipe Diameter Gas/Liquid inch 5/8"/1/4" 5/8"/3/8" 3/4"/3/8" 7/8"/1/2" Built in electric heater KW optional optional optional optional optional optional optional Built in 3-way valve - yes yes yes yes yes yes yes Built in pump - Wilo/Xinhu Indoor Unit mm 660*650*1150 660*650*1150 660*650*1150 660*650*1150 660*650*1150 660*650*1250 660x650x1250 (Free Standing Type) Dimension Indoor Unit (W*D*H) mm 508*406*947 508*406*947 508*406*947 508*406*947 508*406*947 508*406*1000 508*406*1000 (Wall Mounted Type) Outdoor Unit mm 880*360*780 830*310*1230 830*310*1260 930*390*1270 930*390*1270 1105x515x15001105x515x1500 Note: 1.The values of heating(cooling) capacity/power input/cop(eer) are based on measurement of EN14511 standard.usage environment,such as operation of the heating equipment,room temperature,and controller adjustments, may cause disparities between practically determined and these values. 2.Sound pressure level measured at distance of 1m from the device. 3.For Free standing type, the compressor is located in the indoor unit; While for Wall Mounted Type, the compressor is located in the outdoor unit.

7 Enjoy comfortable life with DC INVERTER Monobloc type heat pump BLUEWAY Monobloc Type Inverter Air to Water Heat Pump adopts inverter technology, supplying heating, cooling and hot water. FEATURES Compact, weather-resistant and easy to install Built in water pump Bottom heater included Built in electric heating element APPLICATIONS NOTE: 1, Heat Pump 2, Storage Tank 3, Water Collector 4, Water Separator 5, Floor Heating 6, Vertical Fan Coil 7, High Wall Fan Coil 8, Sanitary hot water 8

Enjoy comfortable life with 8 SPECIFICATION DATAS Monobloc DC Inverter Air To Water Heat Pump Model DHP-09M DHP-12M DHP-15M DHP-15MT DHP-18MT DHP-24MT DHP-30MT HP 3 4 5 5 6 8 10 Power supply V/Ph/Hz 200-240V/1Ph/50Hz 380-415V/3Ph/50Hz Heating capacity kw 9 12.0 15.0 15.0 18.0 24.0 30.0 +7 / 35 floor heating Power input kw 2.1 2.70 3.50 3.40 4.30 5.60 7.30 COP - 4.2 4.4 4.3 4.4 4.2 4.3 4.1 Heating capacity kw 6.8 11.3 12.7 12.7 15.3 21.7 25.6 +2 / 35 floor heating Power input kw 2.1 3.40 3.85 3.80 4.60 6.60 8.20 COP - 3.2 3.30 3.30 3.30 3.30 3.30 3.10 Cooling capacity kw 6 10.0 11.0 11.0 13.3 18.9 22.3-7 / 35 floor heating Power input kw 2.4 3.85 4.40 4.40 5.40 7.60 9.20 EER - 2.5 2.60 2.50 2.50 2.45 2.50 2.40 Heating capacity kw 7.8 10.3 13.0 13.0 15.3 20.6 25.5 +7 / 45 radiators Power input kw 2.4 3.30 4.00 4.00 4.80 6.30 8.20 COP - 3.2 3.10 3.30 3.30 3.20 3.30 3.10 Heating capacity kw 7.6 10.1 13.0 13.0 15.2 20.6 25.3-7 / 45 radiators Power input kw 3.4 5.00 6.20 6.20 7.20 9.80 12.60 COP - 2.2 2.00 2.10 2.10 2.10 2.10 2.00 Cooling capacity kw 7 10.0 11.8 11.8 14.5 20.0 25.0 +35 / 7 fan coil Power input kw 2.6 3.60 4.50 4.50 5.80 7.10 10.00 EER - 2.7 2.80 2.60 2.60 2.50 2.80 2.50 Noise level DB(A) 52 53 55 55 55 56 56 Rated outlet water temp. Max outlet water temp. Ambient temperature range 7~55 60-20~43 Rated water flow rate L/S 0.43 0.57 0.72 0.72 0.86 1.15 1.43 Rated pressure drop kpa 30 40 45 45 45 40 47 Max. Working Pressure Refrigerant Bar 44 44 44 44 44 44 44 Water Bar 7 7 7 7 7 7 7 Water connection inch 1" 1" 1" 1" 1" 1-1/4" 1-1/4" Controller - Micro processor based digital wire controller with LCD display External cabinet - Galvanized steel with powder coating Make - Mitsubishi Hitachi Type - Rotary Scroll Compressor Nos. - 1 1 1 1 1 1 1 Refrigerant R410A Refrigerant amount Kg 1.45 1.9 2.5 2.5 2.6 4.2 4.5 Water heat exchanger Type - Brazed plate heat exchanger Materials - SUS 316 Built in electric heater KW optional optional optional optional optional optional optional Built in 3-way valve - yes yes yes yes yes yes yes Built in pump - Wilo/Xinhu Outdoor Unit mm 1105*470*780 1105*470*1230 1105*470*1260 1105*470*1230 1105*470*12601405x515x15001405x515x1500 1.The values of heating(cooling) capacity/power input/cop(eer) are based on measurement of EN14511 standard.usage environment,such as operation of the heating equipment,room temperature,and controller adjustments, may cause disparities between practically determined and these values. 2.Sound pressure level measured at distance of 1m from the device.

FOSHAN BLUEWAY ELECTRIC APPLIANCES CO.,LTD. ADD: 2-9# Zhanye Rd,Honggang Industrial Area,Shunde District,Foshan Guangdong Tel: +86 757 22629989 / 22629286 Fax: +86 757 26154598 Email: info@heatpumpworld.com Website: www.blueway.hk www.heatpumpworld.com