Fire Detection and Prediction Systems of

Similar documents
JST-JICA Project Wild Fire and Carbon Management in Peat-Forest in Indonesia

FOREST FIRE GROUP Current Status & Planning

Sentinel Asia. Disaster Management Support System. Wild Fire Working Group

Sentinel Asia Wildfire Monitoring

NEAR REAL TIME DETECTION OF BURNED SCAR AREA USING LANDSAT-8 IMAGERIES

ALBERTA FOREST PROTECTION THERMAL INFRARED PROGRAM

Fire Detection and Monitoring

Fire Detection and Fire Prediction Systems:FF

Forest fire detection based on MODIS satellite imagery, and Comparison of NOAA satellite imagery with fire fighters' information

DETECTION AND MONITORING OF ACTIVE FIRES USING REMOTE SENSING TECHNIQUES

Verification and Validation of OOV-TET1 Multispectral Camera Observations within the FireBIRD Project

the EU-Japan Support Mission in the Space Sector

Global Biomass Burning Emissions from a Constellation of Geostationary Satellites for Global Model Forecast Applications

Strategic Research Agenda for. High-Altitude Aircraft and Airship. Remote Sensing Applications

Wildfire Mapping Using FireBIRD Data

Fire Information for Resource Management System (FIRMS)

Interim evaluation of the New IR Sensor Technology (NIRST) as a wildfire monitoring tool

Evaluation of remote sensing-based active fire datasets in Indonesia

UWB Stepped-FM Sensor for Home Security

Recent Developments and Prospects for Innovative Remote Sensing of High-Temperature Events and Vegetation Fire Impacts

Development of a Canadian Wildland Fire Monitoring Sensor (CWFMS)

Advances in Leak Detection in the Manufacturing Process

Use of new spatially refined satellite remote sensing fire detection data in support of advanced wildfire mapping and modeling

Smart Fire Prevention

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

A Forest Fire Warning Method Based on Fire Dangerous Rating Dan Wang 1, a, Lei Xu 1, b*, Yuanyuan Zhou 1, c, Zhifu Gao 1, d

Advanced Fire Information System

Welcome to Shenzhen Keweitai Enterprise Development Co,.ltd. Safety, Professional, Easy, Long endurance, Long distance

SEVIRI/MSG sensor early fire detection performances assessment

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF

eature Enhancement of Functions of Tokaido Shinkansen Earthquake Disaster Prevention System Tadayoshi Arashika and Shigeru Nakajima

International Journal of Scientific & Engineering Research, Volume 7, Issue 7, July ISSN

Leakage detection in hydraulic and pneumatic systems through infrared thermography and CO2 as tracer gas

Understanding total measurement uncertainty in power meters and detectors

HALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM]

The New DUSTTRAK II and DRX Aerosol Monitors

OBSERVING THE EXPANSION OF THE BUILT-UP AREAS OF REGIONAL CAPTAIL CITIES IN YANGTZE RIVER DELTA BY SATELLITE IMAGES

Demands on Electro-optical Cameras for Sensing and Mapping

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

The New DUSTTRAK II and DRX Aerosol Monitors

Google-Earth use as a monitoring tool for EUMETSAT s active fire product

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

Phumza Matitiba Assistant General Manager Eastern Cape

Long-term Inventory of Fire Burned Areas and Emissions of North America s Boreal and Temperate Forests

state of the art methane leak detection CHARM and GasCam 2011 October 13 th Dr. Axel Scherello

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Unmanned Aerial Systems for Supporting Decision Makers at Forest Fires

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

FIRE-RS Project A Nanosatellite & UAVs hybrid system for wildfire characterization.

The operational MSG SEVIRI fire radiative power products generated at the Land-SAF

Development of Seismic-induced Fire Risk Assessment Method for a Building

DEMONSTRATION OF A SEMI-OPERATIONAL FIRE RECOGNITION SERVICE USING BIRD MICRO- SATELLITE - DEMOBIRD

Risk Management of Fire using Video Based Detection

A study on the regional landscape planning framework on the relationships between urban and rural areas: case study of Tokachi region, Hokkaido, Japan

GOES-R AWG Land Team: Fire Detection and Characterization

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES

HELPCOS THE HELICOPTER BASED PIPELINE CONTROL SYSTEM OF VNG - VERBUNDNETZ GAS AG

Hi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety

Optech Thermal IR Sensing Solutions Expanding the Industry

THE NORTHSTAR SYSTEM: A NEW ERA IN EARTH OBSERVATION

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

Automated Fire and Flood Hazard Protection System

Aquarius - Spectrum. multi-layer acoustic water pipe monitoring solutions. Game changer in water network management

Automatic Detection of Defects on Radiant Heaters Based on Infrared Radiation

Further Development of an Ion current Combustion Control System (ICCS)

State-of-the-art Developments to Save Energy in Coating Drying

The use of Slocum gliders to deliver near real-time environmental data for the Oil & Gas and Mining industries Ross Dinsdale General Manager -

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

University of Puerto Rico at Mayagüez Direct Broadcast Polar Orbiter Workshop

A temporal active fire detection algorithm applied to geostationary satellite observations

Wildland fire phenomenology experiments:

VIIRS FIRE PRODUCTS UPDATE

Ombrogenous Peat Swamps and Development

Computer Modelling and Simulation of a Smart Water Heater

A Comprehensive Approach to Leak Detection

Coupling Multiple Hypothesis Testing with Proportion Estimation in Heterogeneous Categorical Sensor Networks

FALCON EYE Land Based Surveillance System

Leak Detection. Ron Threlfall Manager, Leak Detection, Maintenance and Integration

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

Figure 1: Low energy dwellings testsite

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current

The Role of Satellite Observations in Assessing Impacts of Wildfire Occurrence on Respiratory Health of Population

Time-resolved infrared imaging and spectroscopy for engine diagnostics

1.1. SYSTEM MODELING

Global fire hotspots detected by NASA satellite to help United Nations

Current Status of the Mid-Term Management Plan

Innovative protection that combines power and flexibility

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

GOFC/GOLD Fire IT Strategic Planning. Day 1 - Break Out Group Discussion

Smart Wellness. Yoshio Sekiguchi Sr. General manager, Micro Devices H.Q. OMRON Corporation

Physical concepts. Remote sensing of fires and vegetation. Applications of SEVIRI channels.

RLDS - Remote LEAK DETECTION SYSTEM

About HGH Systemes Infrarouges About HGH

Quick start. 2. Turn on the power. When all the led indicator light turns off, the device status is normal, has entered the work state.

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

I NTRODUCTI ON. Oil Palm Immature

Documentation on NORTHSTAR. Jeremy Ma PhD Candidate California Institute of Technology May 17th, 2006

Transcription:

JPTM2013, Bangkok, Thailand, 27-2929, Nov. 2013 Fire Detection and Prediction Systems of Peat-Forest t Fires in JST-JICA JSTJICA Project Toshihisa Honma, Kazuya Kaku 1, Aswin Usup 2 and 3 Agus Hidayat 3 Hkkid Hokkaido Ui University, i Japan 1 JAXA, Japan 2 UNPAR, Indonesia 3 LAPAN, Indonesia

Criteria 1Relevance Very high 2Effectiveness Medium to high 3Efficiency High 4Impact Very highh 5Sustainability High Evaluation Questions Are the Objectives of the Project still relevant? (Do they meet with the needs of beneficiaries?) e es Is the Project consistent with the development policy of the partner country? Is the Project consistent with Japan s foreign and policy and JICA s plan for country-specific program implementation? Is the Project purpose specific enough? Has the Project purpose been achieved? Did the achievement result from outputs? Is there any influence of important assumption on attainment of the Project purpose? Is the output production adequate? Were the activities sufficient to produce the output? Was the input of an adequate quantity and quality performed at the right time to conduct the activities? Does the output justify the invested cost compared to similar project? Has the Overall Goal likelyl been achieved? What are the social, economic, technical, environmental and other effects on individuals, communities, and institutions as a result of the Project? Is there any influence of important assumption on attainment of overall goal? Is there any unexpected positive or negative influence including ripple effects? Are the outcomes (activities and effects) of the Project likely to be maintained after the Project period? Institutional, technical, human resource, and financial aspect, etc.

Project Purpose Before Mid-term Evaluation Peat-forest management model in Indonesia is established. Output 1 Fire Detection and Fire Prediction System are established. Indicator: Activity 1.1 Improve the hotspot algorithms. 1.2Estimate carbon emission by biomass burning among different ecotypes 1.3Transfer in-situ fire information to each region 1.4 Construct prediction model of wild fire occurrence 1.5 Construct model of water regime 1.6 Make map of land cover/land use change 1.7Establish spectral library (plant/soil) in investigation area Project Purpose After Mid-term Evaluation Peat-forest management method to reduce carbon emission is developed. Indicator: 1) Carbon management method which can contribute to carbon reduction of 1/3 to 1/5 amount compared to current level in peatland is proposed. 2) Peat-forest management method is utilized in policy decision in developing international rules and bilateral off set mechanism. 3) Results of researches are published (Number and quality of research papers is good enough) Output 1 Fire Detection and Fire Prediction System are established. Indicator: 1) In the event of a fire with more than 1 km 2 coverage, 3 target communities can obtain fire information within 16 hours, and moreover they can obtain information on fire spread prediction within 8hours. 2) Fire detection accuracy can reach the level of more than 80%. 3) Rate between predicted fire spread coverage and real fire coverage can reach the level of more than 50%. Activity 1-1 Improve the hotspot algorithms 1-2 Estimate carbon emission by biomass burning among different ecotypes 1-3 Transfer in-situ fire information to each region 1-4 Construct prediction model of wild fire occurrence 1-5 Construct model of water regime 1-6 Make map of land cover/land use change 1-7 Establish s spectral library y(plant/soil) in investigation area 1-8 Validate established system

Major achievements to data for output 1 are as follows. Target has been achieved at 80% completion level. Fire detection and fire prediction system was established and tried. Further calculation of accuracy of models will be elaborated by the end of the project period.

1) In the event of a fire with more than 1 km 2 coverage, 3 target communities can obtain fire information within 16 hours, and moreover they can obtain information on fire spread prediction within 8hours. In the event of a fire with more than 1 km 2 coverage, 4 target communities (Tarunajaya, Tumbang Nusa, Pilang and Djabiren) can obtain fire information at an average of 13 16 hours (Average satellite detection time is 6 8 hours, hotspot data analysis time is 4 hours, fire information data production time is 1 hour and SMS data transmission time is 2 3 hours). Fire spread prediction time for 2km area from the target villages is about 4 hours applying simplified fire extension model in accordance with the needs of villages. This current radius (2km) of fire alert target area is adjustable in accordance with demand. MODIS hotspot map and ground water table map are available at http://jica jst.lapanrs.com/

2) Fire detection accuracy can reach the level of more than 80%. All record of 10 hotspot data (July 2009) and 2 current firing hotspot data (September 2012) detected by the improved algorithm were confirmed to be burnt or burning area by UAV photographs (100%). Considering bothomissionomission and commission errors, hotspot detection accuracy is assumed to be able to achieve 80% level though further monitoring is required for statistic accuracy.

3) Rate between predicted fire spread coverage and real fire coverage can reach the level of more than 50%. By using the simplified fire extension model, 1km square hotspot is approximated by either an inscribed circle with the radius 1/2 km or a circumscribed circle with the radius 2/2 km. Considering the interval of satellite image acquisition, predicted fire spread coverage error becomes within 50% if the velocity of hotspot center is less than 2m/min (f (if it is faster than that, it is detected as different fire, not the extension of the same fire by this algorithm).

Activity 1-1 Improve the hotspot algorithms 1-2 Estimate carbon emission by biomass burning among different ecotypes 1-3 Transfer in-situ fire information to each region 1-4 Construct prediction model of wild fire occurrence 1-5 Construct model of water regime 1-6 Make map of land cover/land use change 1-7 Establish spectral library (plant/soil) in investigation area 1-8 Validate established system

Established Systems FF1: Construct wild/peat fire control systems Step1:Detection 1 of Fire Hot Spots by Satellites (resolution:1kmx1km) Step 2:Validation V i of Hot Spots by UAV (Ground Truth) Step 3:Transmission T i i of Fire Information by SMS FF2: Mapping and modeling the land cover Step 4:Calculation of Burnt Area Step 5:Estimation Eti of CO2 Emission i by Biomass Burning among Different Type Ecosystems Step 6:Estimation Eti of CO2 Emission i from Burnt tarea

1 : 6~8 hours STEP 1 1 STEP 2 : 2~3 hours STEP 3 2 STEP 4 6 : 4~5 hours 3 4 5 6 7

1. Improve fire hotspot algorithms

MODIS (1 km 2 mesh) fire hot spot detection system was transferred to the server in LAPAN. Data has been accumulated every day since 20 May 2011. To verify the hot spot dt data obtained by satellites, aerial photography was taken by the electrically powered unmanned aerial ilvehicle (UAV) equipped with optical camera and infrared camera. During the project, two UAV design were developed dand tried. The improved UAV which can fly about 1 hour took kthe forest tfire photography h dt detected tdby the satellite for the first time in September 6, 2012.

In order to validate the satellite detection accuracy of hotspots data, thehotspotsmapdetected hotspots injuly, 2009 was utilized because there were no fires occurred in study site duringdrydry seasons in 2010 2011. 2011.

All 10 hotspots in the 2009 map were confirmed to be burnt area by UAV aerial photography in 2011 and 2012. 48km 38km 7km 6km 4km 6km 10km F 1 (2011.02) F 2 (2011.09) F 3 (2012.09) 43km

F-2(2011)

Ground Validation with UAV(Sep. 2011) Canal UAV Route Taruna Jaya Site Sebangau River Burned Area Mapping Source : JAXA, PALSAR 10m Mosaic Image, Central Kalimantan

F-3 (2012)

3 September, 2012 Two hotspots detected by satellite in 3rd September, 2012 were also confirmed to be real on going fires by UAV aerial photography taken in 6th September, 2012. 22km 20km

MODIS pixel Observed by UAV Flight Distance A~B: 10km Burnt Area: 15~20% A Flight Height: 200m B Plantation Area: Oil Palm

The improved hotspot detection algorithm could find the fire at 100% accuracy though the sample cases are limited. It is concluded that hotspots are detected by the algorithm with the very high precision.

3. Transfer in situ fire information to each region

Village center Taking aerial photography by UAV was conducted above Tarunajaya and Tumbang Nusa, and the possibility of translating the geographical information including its latitude and longitude into the local language was considered,

Fire extension extension direction Peat forest fire information: Velocity < 2m/min date of fire detection distance & direction to hotspots fire dangerous index (FDI) fire extension direction 2 km Time sequence hotspots t Village center Time sequence hotspots t 1 km 1 km : Hotspot inside village : Hotspot outside village Fire extension direction Velocity > 2m/min 4 pilot villages : Tarunajaya, Tumbang Nusa, Pilang and Djabiren

village heads leaders of fire fighting teams LAPAN The first trial to send SMS was successfully conducted in September 26 2013 through the activity 8.

4. Construct prediction model of wild fire occurrence

Wind field around Palangka Raya, at 13:00 local time, 4 September 2006 Palangka Raya A climate prediction model, MM5, was installed in the server in Hokkaido University, it and data dt inputs as well as parameter setting which h reflect the weather condition in Indonesia was examined, and a wind atlas was developed with 5km resolution. by Mr.Hatanaka

Eo 1.0 (= a o /(a F +a o )) A S = k A F A F=a F+a o K=0.5 K=0.75 K=1.0 K=1.33 05 0.5 K20 K=2.0 Ec<Eo<0.5 a o a F a c A S =a F +a c Eo<Ec<0.5 0.0 0.5 1.0 A simulation model on forest tfire spread, tki taking into Ec (= a c /(a F +a c )) consideration the vegetation data, was developed and its validity was examined.

Simplified fire extension model Calculation of burnt area based on time series of 2 km hotspot data b km 36 h c km 1< x km 60 h 72 h 48 h Non extended hotspot 24 h Non extended hotspot 60 h 2< x km 0 h 12 h 24 h Elapsed time Burnt area 72 h a km 1 km 12h a km 2 24h (a + 1) km Movement distance of hotspot center x(km) 2 36h (a + 1 + b) km 0 km < x < 1 km : 2 an inscribed circle approx. 48h (a + 1 + b + 2 + π/8) km 1 km < x < 2 2 km: a circumscribed circle approx. 60h (a + 1 + b + 2+ π/8 + c π/8) km 2 The time sequence of 1km 2 hotspot data was examined and the fire occurrence process in time was clarified. The simplified fire extension model was developed based on time series hotspot data and the fire extension area was estimated as the movement distance of the hotspot center.

5. Construct model of water regime

By Wataru Takeuchi, University of Tokyo, Japan A model was established to estimate the spatial distribution of soil moisture based on satellite data, and the validity of the model was verified by comparing the measurement data of ground water level with the model. By integrating the data from fixed point observation into the satellite data, the spatial distribution of soil moisture was presented with high precision for the first time in the world.

:no peat/forest fire small damage of peat/forest fire heavy damage of peat/forest fire Ground Surface Fires Surface Layer Peat Fires Deep Layer Peat Fires 250 Plot 2 50 Plot 1B Camp Plot 1B no data itation (m mm) 日雨量 (mm) Dail ly Precip 200 0 no data 150-50 100-100 50-150 Groun nd Water 地下水位 Level (cm) (c cm) 0-200 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 Ground water level in a peat swamp forest and the level of damages of peat/forest fire for 11 years The validity of the established water fluctuation/soil il moisture estimation i model Water level for was examined though the accumulation of data and fixed point measurement. 11 years

Fire Dangerous Index (FDI) Ground Water Table, CO2 Emission and Peat Fire Index FDI 1 :Ground Water Level 20cm~ 50cm Ground Surface Fire FDI 2:Ground Water Level 50 cm ~ 100cm Surface Layer Peat Fire FDI 3:Ground Water Level 100cm~ Deep Layer Peat Fire The level lof the peat fire index (PFI) was dfi defined dby the correlation of the ground water level with the number of fire occurrence and the fire dangerous index based on PFI was developed.

8. Validate established system

The practical operation of fire detection and prediction based on the integrated systems and SMS, is carried out. The several fire processes such as satellite hotspot detection hotspot data The several fire processes such as satellite hotspot detection, hotspot data analysis, fire information production and delivery, and UAV verification is integrated.

Specification of F 4 UAV : 2013.09 Length/Wing Length/Height 21m/2 2.1m/2.76m/0.47m Weight:5.5kg with Battery Power:Brushless Motors : 2 units Flight Speed:Max 100km/h Cruising Speed 50 80km/h Flight Time: Max 90 min. Payload: Max 1kg Data Link: 2.4GHz (Specified Low Power Wireless) Communication Distance: 10km

100 Comparison of UAV Specification Electric Motors 300 Electricity vs. Gasoline 90 80 250 70 200 60 50 40 F 2 F 3 F 4 150 F 4 Gasolin Eng. 30 100 20 50 10 0 Wing Length Length Weight Flight Time 0 Wing Length Length Weight Flight Time

Specification of UAV with Engine Length/Wing Length/Height 2.6m/3.2m/0.9m Weight:35kg with Engine Engine: BT 86B7.5HP 86cc 2 Cycle Gasoline Engine 2 Cylinders Flight Speed: Max 180km/h Cruising Speed: 120km/h Flight Time:Max 4hours Flight Height :Max 4500m(14800f) Payload: Max 6kg Data Link:2.4GHz (Specified Low Power Wireless) Communication Distance: 10km

After suppression of fires, leaders of fire fighting teams reported to participants at meeting about the suppression activities based on fire information delivered through SMS, in which suppression starting and ending time, the type of fire, the fire burned area size and personal impression etc. are reported. In addition, leader of UAV monitoring team explained the UAV flight performance and current moving images of real fires taken by UAV. The usefulness of the information system for suppression of real fires by fire fighters is confirmed.

Conclusion

Green