Introducing Low Voltage DC Grid Interconnects

Similar documents
Introducing Hermaphroditic Blade and Receptacle Connector

Introducing SlimSeal SSL Connector

Quick Reference Guide Barrier Strips

Introducing Inverted SMT Thru Board Connector

SOLARLOK Interconnection System Installation Manual

Introducing Solar Identification Labels

Pin, Spool & Strain Insulators

Z-PACK TinMan 85 ohm Connector Overview

Quick Reference Guide.050 Centerline Micro-MaTch Connector Series

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Introducing Corcom DB Series

LOW POWER AND SIGNAL APPLICATION GUIDE APPLIANCES /// LOW POWER & SIGNAL APPLICATION GUIDE

Introducing Corcom CU Series 1U Height Power Entry Modules

PlanarMag Product Technology

Standard and Customized Hand Tool Kits

ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS

AMP SUPERSEAL 1.5 SERIES Connectors

Quick Reference Guide: Connectors for Mobile Devices

S200 SHIELD TERMINATORS

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

Article 393 Low Voltage Suspended Ceiling Power Distribution System

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

CII FCAC-150 Series Relay

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

Signal Connectors for Topside and Subsea Applications

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications

Battery Interconnects

WILDLIFE AND ASSET PROTECTION PRODUCTS

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO

Universal Connectivity Platform

QUADRAX D-SUB CONNECTORS

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

RAYCHEM MEDIUM VOLTAGE

Reliable solutions for electrified railway systems

Mar11 Rev C

Universal Connectivity Platform A Modular Approach to Infrastructure Design

.025 Connector Series

TE Connectivity Product & Application Guide

NECTOR S Line lighting components. Flexible solutions for your lighting designs

Jun08 Rev C

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

High Density Optical In-Line Dry-Mate Connector (ILC) High Performance Multichannel Fiber Optic Connectors

24 Volt DC Edition EMerge Alliance Registered Products

Gas Discharge Tubes GTCX25-XXXM-R02 Series

Your Pick... One Solution

Gas Discharge Tubes. Features: Benefits: Applications:

Gas Discharge Tubes GTCX28-XXXM-R05 Series

Two Circuit Heavy Duty Burner Connector

HARTMAN Smart AC Contactors

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE

KILOVAC K1K High-Voltage Contactor

Jan05 Rev A EC

Hydraulic Crimping Systems

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES

INDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

M7100 Pressure Transducer

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Application Specification MAG-MATE* Poke-In Tab Terminals

UNIQA-PRO SINGLE CRIMP WIRE PROCESSOR

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

The Importance of Pressure Sensors in HVACR Systems

I can do WHAT? A look into Compass Viewers

TE Connectivity's AMP NETCONNECT Cable Management

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Introduction. Technical Features

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

Dear Concessionaire,

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES WE GO TO EXTREMES TO MAKE EVERY CONNECTION COUNT

626 Pneumatic Tool System The Effortless Alternative to Hand Crimping

Linear Current Sensors

Project Name. Date. Cat. Number. Type

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

CABLES AND ACCESSORIES FOR TRUBLUE DATA LOGGERS

Inverted Through Board Surface

STANDARD T6 (200 C) SENSOR CABLE RANGE

RENEWABLE ENERGY. Durable solutions for maximum efficiency and the promise of reliability. ENERGY PIONEERS IN POWER SOLUTIONS

Project Name. Date. Cat. Number. Type

Model GIT 4 Gutter Snow and Ice Melting Control

MODEL 4000A & 4001A ACCELEROMETER

Raychem Link Boxes. Cable Services Limited. Powering the UK

FF 120T FF 220T EXTRON EXCLUSIVE PATENT PENDING FLAT FIELD SPEAKER WITH TRANSFORMER SPEAKERS. See How it Works WHITE PAPER

Specification Status: Released

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Lead Makers and Harness Makers

AUTOMOTIVE MINIATURE WIRE (AMW)

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

DEUTSCH D3 SERIES PCB CONTACTS FOR SERIES III-STYLE CONNECTORS

BUDI-M-SP. Building distributor. Introduction. Seals. Kit content. Accessories. Wrap around cable seals

Switches & Sensors FOR VALVES & ACTUATORS

Transcription:

Introducing Low Voltage DC Grid Interconnects

LVDC Grid Interconnects KEY FEATURES Power Feed Cable Assembly Power Feed Connectors are available upon special request comprising of the following: - Universal MATE-N-LOK housing (350777-1) - Universal MATE-N-LOK contacts (350923-3) - Strain relief (640713-2) - Self tapping screws (1-5025933-3) Load (Device) Cable Assembly Load (Device) Connectors are available upon special request comprising of the following: - Housing (2106730-1) - Clamp (2106724-1) - Contacts (2106733-1) - Black heat shrink (2079524-1) - Yellow heat shrink (2079523-1) Bus Bar to Bus Bar Cable Assembly External Bus Bar (Fixture or Device) Connector Internal Bus Bar (Fixture or Device) Connector - Positive latching - Threaded coupling Plenum rated Universal MATE-N-LOK connector, part number 350786-1, available for panel/bulkhead side connector for power supply module Descriptions LVDC Grid Interconnects are low voltage direct current (DC) connectors and cable assemblies developed to transfer power to and from lighting fixtures, power supplies, controls and other electrical devices intended for use in an EMerge Alliance compliant system. The design allows for fixture and other electrical device adds, moves and changes on both sides of a bus bar structure, i.e. above an below a suspended ceiling, without the need for hard wire changes. LVDC Grid Interconnects were designed specifically to meet the requirements of the EMerge Alliance Standard, a new power distribution platform for the use of safe, low voltage DC Power in commercial interiors SYSTEM Advantages A safe, low-voltage DC distribution system Provides a plug and play standard for integrated management and control of more energy efficient and individually controllable devices such as LED lighting and other digital devices Eliminates device level AC to DC electrical power conversions Provides flexibility to readily arrange and rearrange lighting, actuators and other devices without the need for rewiring Easier integration of on-site alternative energy sources such as solar, wind, fuel cell and batteries, with traditional AC power sources APPLICATIONS (Designed for use with the Emerge Alliance compliant systems) Power Feed Cable Assembly : Connects between a power server and a low voltage bus bar Load (Device) Cable Assembly : Connects lighting fixtures and other electrical devices to low voltage bus bar Bus Bar to Bus Bar Cable Assembly : Connects sections of low voltage bus bar together External Bus Bar (Fixture or Device) Connector : Mounts directly to a drop-in fixture enabling connection to a bus bar component, especially when the bus bar is incorporated in a suspended ceiling grid Internal Bus Bar (Fixture or Device) Connector : Provides mounting and electrical interconnect for lighting fixtures and other devices mounted to a suspended ceiling grid, i.e. and Armstrong DC FlexZone Suspended System MECHANICAL Environmental operating temperature : -55 to 85 C Internal Bus Bar (Fixture or Device) Connector : 50 cycles External Bus Bar (Fixture or Device) Connector : 50 cycles Load (Device) Cable Assembly : 50 cycles Power Feed Cable Assembly : 10 cycles Bus Bar to Bus Bar Cable Assembly : 10 cycles Tyco Electronics I LVDC Grid Interconnects *EMerge Alliance is a registered trademark of the EMerge Alliance Corporation. Armstrong DC FlexZone Suspended System is a trademark of Armstrong Ceilings.

Electrical Operating current : Up to 4.1 Amps Operating voltage : 24 Volts DC (nominal) MATERIALS Housings : Thermoplastic Contacts : Phosphor bronze Finish : Tin over nickel Standards AND SPECIFICATIONs EMerge Alliance System Standard (Pending) UL2577 ANSI/NFPA 70 Application Specification : 114-13275 Product Specification : 108-2414 Typical EMerge Alliance Compliant System AC Branch Power Optional On-Site DC Power DC Ceiling Grid HVAC Actuator Tyco Electronics interconnects are highlighted in TE Logo and Tyco Electronics are trademarks. Occupancy & Daylight Sensors AV Devices & Security IT Wireless Access Device Power Supply Lights Room Controls Copyright 2009 EMerge Alliance. All rights reserved. *Diagram courtesy of EMerge Alliance Corporation *Suspended ceiling grid shown in photos is Armstrong DC FlexZone Silhouette, courtesy of Armstrong Ceilings. *EMerge Alliance is a registered trademark of the EMerge Alliance Corporation.

LVDC Grid Interconnects PRODUCT DIMENSIONs Power Feed Cable Assembly Length ft [mm] 2106725-1 5.0 [1524.0] 2106725-2 10.0 [3048.0] 2106725-3 15.0 [4572.0] 2106725-4 20.0 [6098.0] Bus Bar to Bus Bar Cable Assembly Length ft [mm] 2106728-1 3.0 [914.4] Load (Device) Cable Assembly Length ft [mm] 2106718-1 5.0 [1524.0] 2106718-2 10.0 [3048.0] LVDC Grid Interconnects I Tyco Electronics

LVDC Grid Interconnects PRODUCT DIMENSIONS Cont. External Bus Bar (Fixture or Device) Connector Wire Size 2106739-1 18 AWG Solid Internal Bus Bar (Fixture or Device) Connector Wire Size 2106710-1 18 AWG LVDC Grid Interconnects I Tyco Electronics

FOR MORE INFORMATION www.tycoelectronics.com/lighting Technical Support Internet: www.tycoelectronics.com/help USA: +1 (800) 522-6752 Canada: +1 (905) 470-4425 Mexico & Central America: +52(0) 55-1106-0814 South America: +55 (0) 11-2103-6000 Germany: +49 (0) 6251-133-1999 UK: +44 (0) 800-267266 France: +33 (0) 1-3420-8686 Netherlands: +31 (0) 73-6246-999 China: +86 (0) 400-820-6015 Part numbers in this brochure are RoHS Compliant*, unless marked otherwise. *as defined www.tycoelectronics.com/leadfree Tyco Electronics Corporation Harrisburg, PA tycoelectronics.com 2010 Tyco Electronics Corporation All Rights Reserved. 7-1773456-1 4M FP 02/2010 MATE-N-LOK, TE (logo) and Tyco Electronics are trademarks of the Tyco Electronics group of companies and its licensors. Other products, logos, and Company names mentioned herein may be trademarks of their respective owners. While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this catalog, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco Electronics expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this catalog are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult Tyco Electronics for the latest dimensions and design specifications.