BRG-N100 BACnet Objects. BRG-N100 Modbus Register Map

Similar documents
Advantage III. Gold Series by Ebtron. Installation Guide GTC116. Plug & Play Transmitter with Combination RS-485 Network Output and Dual Analog Output

Advantage III. Gold Series by Ebtron. Installation Guide GTC116-B

EB-Flow I-P Units Application Specific Airflow Measurement with Temperature & Alarm Capability (LED PWR JUMPER INSTALLED) COM

SETUP MENUS (PART 1 OF 5)

Advantage III. Gold Series by Ebtron. Installation Guide GTM116-B

EF-A2200-U (CONFIGURED AS DUAL) WIRING DIAGRAM

EB-Flow I-P Units Application Specific Airflow Measurement with Temperature & Alarm Capability (LED PWR JUMPER INSTALLED) COM

Advantage III. Gold Series by Ebtron. Installation Guide GTC108. Plug & Play Transmitter with Combination RS-485 Network Output and Dual Analog Output

Carbon Monoxide Transmitter

Greentrol Automation, Inc.

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

Product Manual SZ1145

Product Manual SZ1144

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

Analog Room Pressure Monitor RPC Series

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

CLEANROOM MONITOR CR3A Network - Installation Instructions

Carbon Monoxide Transmitter

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Process & TeMPerATUre UniversAl input DigiTAl MeTers

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

Planning Elevator Relay Groups Programming Millenium for Windows Software

Modbus RTU RS485 Manual

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

RPM1600 Series Room Pressure Monitors

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

USER MANUAL FOR OPERATING SYSTEM

21-light Remote Annunciator. Owner s Manual

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

ARO Series. Description. Features. Modbus CO2 VOC. Networkable* ARO AROB24TGVH AROB24TGH. room controller. (AROB series only) or network

Pump-Up Controller MODEL 4062

Humidity Controller Specification and Installation Instructions. Model HRO20

Networkable Fan Coil Controller Specification and Installation Instructions

Multiview Monitor / Controller

RS485 MODBUS Module 8AI

Installation Manual Tracker 221

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

Pump-Down Controller MODEL 4052

Compod. Instruction Manual IM-COMPOD Revision: F, December 2015

Temperature Controllers

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

CONTROL UNIT: REFERENCE MANUAL

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

OWNER S OPERATION MANUAL

FlameGard 5 MSIR HART

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFH24F3XYZ2 Stand-alone with Internal Humidity Sensor

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Alarm Output None. Code 5 N Y N R2 R3 A AC/DC100~240V. 2 Relays 3 Relays R4 4 Relays O2 2 Open Collect O3 3 Open Collect O4 4 Open Collect

1600 Gas Controller. User s Manual. Industrial Scientific Corporation. Version 3.2 September 1, 2006

Lift Station Level Controller

User manual. KNXgal. version

Introduction. What is the W2W Open controller?

FlameGard 5 UV/IR HART

MODEL P531, P532 AND P532UI FLAME MONITOR OPERATING MANUAL

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Products no longer available

Bacnet Room Setpoint & Temp Display. Descriptions. Specifications

Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Compod. Instruction Manual IM-COMPOD Revision: C.1, November 2010

Tri-Stack Smart System

MO n : 12JMC rév A

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Two-Channel Gas Controller

M2500 Engine Controller Installation Manual

Honeywell P531, P532 and P532UI Flame Monitors

Ethernet General Purpose

MODBUS / BACnet Adapter Installation Instructions

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Intelligent Single Loop Fire Alarm Control Panel

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

MODEL 2852-HCF. Floating Oil Spill Alarm. User Manual

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

MODEL 4200-IR-2 (Up to 2 Sensors) MODEL 4200-IR-4 (Up to 4 Sensors) MODEL 4200-IR-6 (Up to 6 Sensors)

CTT8 TEMPERATURE MONITOR DEVICE

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

Mark 25 Ultrapure Water Conductivity Analyzer

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

TSI Model 8630 PRESSURA Room Pressure Monitor Modbus Communications Application Note LC-106

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

Water Source Heat Pump Module Technical Guide

Metasys Integrator Compu-Aire Application

20 Light Remote Annunciator

F Technical Bulletin SC 370 SMART Modbus Interface

Transcription:

BRIDGE I-P Units RS-485 Network Bridge with Configurable Display and Alarm Capability 100 SERIES BRG-N100 INSTALL / SETUP DOCUMENT PN: 930-0560 BRG-N100 TYPICAL WIRING DIAGRAM BRG-N100 NETWORK BRIDGE LED PWR LED PWR JUMPER ON JUMPER OFF 1 NET + 1 NET + J2 2 NET J2 2 NET 3 NET COMMON 3 NET COMMON 1 ANALOG INPUT SIG 1 ANALOG INPUT SIG 2 ANALOG GROUND 2 ANALOG GROUND J3 3 NO CONNECTION J3 3 ALARM RELAY COM 4 ALARM LED (+15mA) 4 ALARM RELAY CONTACT 1 24VAC POWER IN J6 1 24VAC POWER IN 2 24V GROUND J6 2 24V GROUND LED PWR JUMPER J3 J6 J2 ANALOG IN/ 24VAC RS-485 ALARM OUT IN 1 2 3 1 2 3 4 1 2 GROUND 24VAC ALARM LED GROUND ALARM LED SIGNAL +15 ma ALARM RELAY DRY CONTACT ALARM RELAY COMMON GROUND 24VAC (ONLY WHEN LED PWR JUMPER IS INSTALLED) (ONLY WHEN LED PWR JUMPER IS INSTALLED) (ONLY WHEN LED PWR JUMPER IS REMOVED) (ONLY WHEN LED PWR JUMPER IS REMOVED) TRANSFORMER 24 VAC / 50-60 HZ (SEE NOTES 2 AND 3) 24 VAC OUT N.O. RELAY DRY CONTACTS 30VDC/24VAC @ 3 AMPS MAX COM LINE IN EXTERNAL LED ALARM INDICATOR EXTERNAL ALARM LED (15 ma) ILLUMINATES ON ALARM (LED PWR JUMPER MUST BE ON ) RELAY ALARM DRY CONTACTS (LED PWR JUMPER MUST BE OFF ) ANALOG DEVICE TO BE MONITORED ANALOG SIGNAL FROM DEVICE TO BE MONITORED + MONITORED ANALOG SIGNAL (TO J3-1) -MONITORED ANALOG SIGNAL COMMON/GROUND (TO J3-2 SEE NOTES 2, 3) SHIELDED TWISTED PAIR (STP) WITH GROUND IS RECOMMENDED (SUPPLIED BY OTHERS) - SEE NOTE 1 RS-485 OUTPUT TO BAS NET COMMON (FROM J2-3) NET (FROM J2-2) NET + (FROM J2-1) BUILDING AUTOMATION SYSTEM NOTES: 1: CONNECT ANALOG SIGNAL AND NETWORK CABLE DRAINS TO EARTH GROUND AT ONE END OF CABLE ONLY. 2. THE BRG-N100 IS A NON-ISOLATED DEVICE USING A HALF-WAVE RECTIFIER ON THE 24VAC POWER INPUT. IF MULTIPLE DEVICES ARE POWERED BY THE SAME TRANSFORMER OUTPUT, ALL GND CONNECTIONS MUST BE COMMON, OR A DEDICATED TRANSFORMER MAY BE USED TO PREVENT EQUIPMENT DAMAGE. 3. ALL DEVICES ON MULTIPLE BRG-N100 INSTALLATIONS WITH A COMMON 24VAC SOURCE MUST BE WIRED IN-PHASE TO THE SAME TERMINALS (e.g.: J6-1 to J6-1, J6-2 to J6-2). 4. SHIELDED TWISTED PAIR (STP) WIRING WITH GROUND IS RECOMMENDED (SUPPLIED BY OTHERS). 5. DRY RELAY CONTACT RATING MAXIMUM 30VDC/24VAC @ 3 AMPS MAXIMUM. EBTRON 1663 Hwy. 701 S., Loris SC 29569 Toll Free: 800.2EBTRON (232.8766) Fax: 843.756.1838 Internet: EBTRON.com 1

BACNET OBJECTS LIST Type, ID Name Default Units Device BRG-N100 BRG-N100 BACnet Objects AI, 1 Analog Input FPM AI, 2 Alarm Status None BO, 1 Relay None BO, 2 LED None Notes: Writable Properties: Present Value, COV, Out of Service, Units, Max Present Value, Min Present Value, Polarity (Relay). Default Baud is 76,800. Internal write is at Priority 16. Priority 1-8 are non-volatile. Notes INACTIVE = Open, ACTIVE = Close; Write at any Priority less than 16 INACTIVE = Off, ACTIVE= On; Write at any Priority less than 16 MODBUS REGISTER MAP Function Address Type Description Range/Value 2 10001 boolean Trouble Status 0:OK, 1:Trbl 4 30001-30002 float AI1 Scaled Value Minscale to Fullscale 4 30003 BRG-N100 Modbus Register Map 16 bit unsigned Alarm Status - Write 0 to clear 0: No alarm 1: High Alarm 2: Low Alarm 3: Both 4 30005-30006 float Analog Input Fullscale 0 to 999,999 4 30007-30008 float Analog Input Minscale -999,999 to 999,999 4 30009 16 bit unsigned Relay 0 = Open, 1 = Closed; Any other value clears write 4 30010 16 bit unsigned LED 0 = Off, 1 = On; Any other value clears write 4 30201 16 bit unsigned Float word order 0: high word first; 1: low word first Note: Default is 19,200, even parity, 1 stop bit. SYSTEM OF UNITS MENU SYSTEM OF UNITS MENU Simultaneously depress/release ENTER + ESC keys during normal operation to select * Factory Default/Current Setting Enter (move ) Enter (move ) Enter (action, move ) Esc (normal oper.) Esc (move ) Esc (move ) ACTION *IP/SI=IP SYS SET IP/SI? IP/SI=IP SYS IP/SI=SI SYS Set system units to IP (FPM, CFM) Set system units to SI (MPS, LPS) 2 EBTRON 1663 Hwy. 701 S., Loris SC 29569 Toll Free: 800.2EBTRON (232.8766) Fax: 843.756.1838 Internet: EBTRON.com

SETUP MENUS (PART 1 OF 4) SETUP MENU Simultaneously depress/release + keys during normal operation to select * Factory Default/Current Setting Enter (move ) Enter (move ) Enter (move ) Enter (move ) Enter (action, move ) Esc (normal oper.) Esc (move or prev setting) Esc (move or prev setting) Esc (move ) Esc (move ) ACTION SETUP GENERAL *NAME={unit serial#} SET NAME? Instruction text: "USE AND ENT" then: NAME= _ Enter Name for BRG-N100 transmitter (Default = Unit Serial Number) *IN1 TYPE=AIN SET IN1 TYPE? IN1 TYPE=AIN Set input type to Analog Input IN1 TYPE=NET Set input type to Network *IN1 UM=FPM SET IN1 UM? IN1 UM=NONE Set input units of measure. IN1 UM=FPM Note: Changing this value will reset the defaults for fullscale, minscale, and alarm setup. IN1 UM=CFM IN1 UM=% IN1 UM=CUSTOM if IN1 UM=CUSTOM *UNITS=% SET UNITS? USE & ENT Enter custom units. Note: Instructions will be displayed until key is pressed. if IN1 UM=NONE or CUSTOM *PRECIS=1 SET PRECIS? PRECIS=1 Set precision when units of measure is NONE, or CUSTOM. PRECIS=0.1 PRECIS=0.01 PRECIS=0.001 PRECIS=0.0001 *LLIMIT=0 SET LLIMIT? LLIMIT=0 Set the measurement value below which, readings are ignored by the transmitter. DISPLAY *LCD DSPL=IN1 SET LCD DSPL? LCD TRBL=OFF Set LCD display to OFF or IN1 LCD TRBL=IN1 *LCD TRBL=ON SET LCD TRBL? LCD TRBL=OFF Set LCD to display TROUBLE indication LCD TRBL=ON O 1A O 1B TO PART 4 TO PART 2 EBTRON 1663 Hwy. 701 S., Loris SC 29569 Toll Free: 800.2EBTRON (232.8766) Fax: 843.756.1838 Internet: EBTRON.com 3

SETUP MENUS (PART 2 OF 4) FROM PART 1B O if IN1 TYPE = AIN ANALOG IN *AI1 SGNL=mA SET AI1 SGNL? AI1 SGNL=VDC Set analog input signal type AI1 SGNL=mA if AI1 SGNL=mA *AI1 RNGE=4-20 AI1 RNGE=FIXED if AI1 SGNL=VDC *AI1 RNGE=0-10 SET A1 RNGE? A1 RNGE=0-10 Set analog input signal range A1 RNGE=0-5 A1 RNGE=2-10 A1 RNGE=1-5 *AI1 FS=3000 SET AI1 FS? AI1 FS=3000 Set analog input full scale value *AI1 MS=0 SET AI1 MS? AI1 MS=0 Set analog input minimum scale value *AI1 INTG=3 SET AI1 INTG? AI1 INTG=3 Set analog input integration value (number of readings that are averaged for each input measurement) NETWORK *NETOUT=BACNET SET NETOUT? NETOUT=BACNET Set network output type. Note: If input type is network then BACNET is the only option. NETOUT=MODBUS Modbus is only available if input type is analog. *NETADDR= 2 SET NETADDR? NETADDR=2 Set network address. *NETBAUD=76800 SET NETBAUD? NETBAUD=76800 Set baud rate. NETBAUD=38400 NETBAUD=19200 NETBAUD=9600 if NETOUT = MODBUS *PARITY=EVEN SET PARITY? PARITY=EVEN Set parity. PARITY=ODD PARITY=NONE1 PARITY=NONE2 if NETOUT = BACNET *NETDI=2 SET NETDI? NETDI=2 Set network device instance. if IN1 TYPE = NET *INDI=2 SET INDI? INDI=2 Set input network device instance. *INOBJ=AI SET INOBJ? INOBJ=AI Set input network object type INOBJ=AO INOBJ=AV *OBJID=1 SET OBJID? OBJID=1 Set input network object ID *POLLING=60 SET POLLING? POLLING=60 Set polling time in seconds O 2 TO PART 3 4 EBTRON 1663 Hwy. 701 S., Loris SC 29569 Toll Free: 800.2EBTRON (232.8766) Fax: 843.756.1838 Internet: EBTRON.com

SETUP MENUS (PART 3 OF 4) FROM PART 2 O ALARM *LO ALRM=OFF SET LO ALRM? LO ALRM=OFF Enable LO alarm LO ALRM=ON *HI ALRM=OFF SET HI ALRM? HI ALRM=OFF Enable HI alam HI ALRM=ON *SETPNT=0 SET SETPNT? SETPNT=0 Enter setpoint for alarm *TOLTYPE=% SET TOLTYPE? TOLTYPE=% Set tolerance type, either as a percent of setpoint or as a fixed value above or below setpoint TOLTYPE=VAL *TOL=0 SET TOL? TOL=0 Enter tolerance as fixed value *TOL=10% SET TOL? TOL=10% Enter tolerance as percent of setpoint *DELAY=2 MIN SET DELAY? DELAY=2 MIN Set alarm delay *ZERO OFF=NO SET ZERO OFF? ZERO OFF=NO Enable ZERO OFF. If set to YES, ALARM will be inactive (OFF) when measured input is below LOW LIMIT. ZERO OFF=YES *RESET=AUTO SET RESET? RESET=AUTO RESET=MANUAL Set alarm reset to AUTO or MANUAL. AUTO will clear alarm activation when alarm condition is no longer present. MANUAL requires user to clear alarm activation. RELAY *RLAY ASN=ALRM SET RLAY ASN? RLAY ASN =TRBL Set relay assignment RLAY ASN =ALRM RLAY ASN =BOTH RLAY ASN =NONE *NORMAL=CLOSE SET NORMAL? NORMAL=OPEN Set normal state of relay NORMAL=CLOSE LED *LED ASN=ALRM SET LED ASN? LED ASN =TRBL Set LED assignment LED ASN =ALRM LED ASN =BOTH LED ASN =NONE EBTRON 1663 Hwy. 701 S., Loris SC 29569 Toll Free: 800.2EBTRON (232.8766) Fax: 843.756.1838 Internet: EBTRON.com 5

SETUP MENUS (PART 4 OF 4) FROM PART 1'A' O 4 TOOLS SECURITY *LOCK SEC=LOW SET LOCK SEC? LOCK SEC=LOW Enable LOW setting where code is last four digits of board serial number. LOCK SEC=MED Enable MED setting where code is entered from user. Contact Customer Service to unlock if code is lost. LOCK SET=HIGH Enable HIGH setting where code is entered from user. If code is lost, unit must be returned to factory to unlock. *LOCK=OFF SET LOCK? LOCK=OFF LOCK=ON ENTR CODE:0000 CONF CODE:0000 Enter code and confirm code (NOTE: if LOCK SEC= HIGH, DO NOT lose code!) RESET RESET ALL ARE YOU SURE? RESET ALL=YES Reset transmitter to defaults RESET ALL=NO RESET NET ARE YOU SURE? RESET NET=YES Reset network settings RESET NET=NO RESET TRBL SET ARE YOU SURE? RESET TRBL SET=YES Resets any disabled trouble codes RESET TRBL SET=NO DIAGNOSTICS TRBL CODES 1: (TROUBLE code) DSBL TRBL CODE? DSBL TRBL=NO Do not disable active TROUBLE indication DSBL TRBL=YES Disable active TROUBLE indication TRBL HISTORY 1: (TROUBLE code) View last 5 TROUBLE codes SERIAL NUMBERS UNIT ####### BRD ##### FW REV V1.## INPUT VALUE AIN= ##### Displays input value INPUT VOLTS AI1= ##.### Displays input volts if analog input NET STATUS NO ERRORS Displays network status IG_BRG-N100_R1C 6 EBTRON 1663 Hwy. 701 S., Loris SC 29569 Toll Free: 800.2EBTRON (232.8766) Fax: 843.756.1838 Internet: EBTRON.com