Model Series 700. detcon. Environmentally Bulletproof Gas Detection Sensors. Multi-Layer Surge Protection Water-Proof Corrosion-Proof

Similar documents
DETCON MODEL SERIES 700 GAS DETECTORS

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection

Industrial Grade Gas Detection

Fixed Gas Detectors Portable Gas Detectors Flame Detectors SmartWireless Control Solutions Gas Analyzers GF-00002A-EN

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

SIL 2. Ultima X Series Gas Monitors CERTIFIED

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Model 1000 H 2 S E-Chem/ CO 2 Process Analyzer

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

3M Oldham OLCT 100. Description. Fixed Gas Detector

Sieger Apex. Flexibility that meets your requirements

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Model D12. Digital Gas Transmitter

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

OLC(T) 100 FIXED GAS DETECTOR

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

INSTRUCTION MANUAL Detcon Model DM-700

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Model D12-IR. Digital Gas Transmitter...

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

INSTRUCTION MANUAL Detcon Model IR-700

Warranty Registration

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Fixed Gas & Flame Detection International Product Range Overview

INSTRUCTION MANUAL Detcon Model IR-700

The Art of Gas Detection

for Today s Industrial Environment

ESD3000 ESD200 Combustible / Toxic Gas Detector

Dräger Polytron 8000 Stationary gas detector (EC)

Toxic Gas Detection. Model F12. Toxic Gas Detection

INSTRUCTION MANUAL Detcon Model FP-700

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

MSA Fixed Gas & Flame Detection for the Automotive Industry

Operation & Maintenance Manual

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Transmitters/Sensors. OLCT Series

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

GAS DETECTOR ST400EC PART.NO

GAS PLUS ALARM SYSTEM

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Better detection. Better protection. Fixed Gas & Flame Detection Product Overview - North America Region

ALTAIR 5X Multigas Detector

S5000 Gas Monitor. GMS5000.com

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

INSTRUCTION MANUAL Detcon Model TP-624D

ALTAIR 5X Multigas Detector Product Specification

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

INSTRUCTION MANUAL Detcon Model TP-524D-HRT

FM Approved Fire & Gas Detection System

ESD500. ESD500 Combustible / Toxic Gas Detector

INSTRUCTION MANUAL Detcon Model TP-624D

Dräger Polytron 7000 Fixed gas detector

Danfoss gas detection unit Type GD Heavy Duty

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

M2A Transmitter Operator s Manual

ULTIMA X5000. MSAX5000.com

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Two-Channel Gas Controller

B -MG0 i gle G Detecti A rm Ma a nstructio. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Dräger Flame 2100 Flame Detection

Operation and Maintenance Manual

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

GAS DETECTION International Gas Detectors CH4 NO

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dependable Solutions for Gas Detection

Frequently Asked Questions

Monitores Personales. Personal Monitor

MSA Gas Detection. for the Water and Wastewater Industries. Does your facility meet NFPA 820?

Dräger Polytron 8700 IR Detection of flammable gases and vapors

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Detcon MicroSafe Model DM-634C Oxygen Deficiency Sensor (0-25% O2)

FIXED POINT SINGLE OR DUAL GAS MONITOR WITH DUAL ANALOG OUTPUTS

SEC Signature Process Gas Analyzer

BST-MG01 Single Gas Detecting Alarm Manual Instruction

GAS DETECTORS. When every second counts

incontrol Systems Inc. Flame and Gas Detection

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Transcription:

PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 281-367-4100 281-292-2860 (fax) sales@detcon.com detcon Model Series 700 Environmentally Bulletproof Gas Detection Sensors Multi-Layer Surge Protection Water-Proof Corrosion-Proof CHEMFET MOS Solid State H2S Sensor CATALYTIC Combustible Gas Sensor detcon inc. Catalog #700-0505 INFRARED Combustible Hydrocarbons & CO2 Sensors ELECTROCHEMICAL Range of Toxic Compound Sensors OXYGEN O2 Deficiency Sensor PHOTO IONIZATION Volatile Organic Compound Sensors www.detcon.com ISO 9001 Certified

M odel Series 700 Description Detcon Model Series 700 industrial gas detection sensors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. The sensors are specifically designed for harsh and extreme locations. This new and superior level of environmental durability in sensor design includes an electropolished 316 stainless steel housing, multi-layered transient spike protection circuitry and 100% epoxy encapsulated electronics. The sensor electronics are completely protected and immune to water ingress and corrosion. The gas detector sensor elements are all plug-in components and can easily be replaced in the field. Operator interface is non-intrusive via a small handheld magnet. Configuration and routine calibration is intuitive and menu driven with fully scripted instructions. Sensor status is displayed on a built-in alphanumeric LED display. Model Series 700 intelligent sensor modules feature dual redundant outputs, a linear 4-20 milliamp analog signal and a Modbus RS-485 serial output. It is becoming increasingly important for safety systems to be able to meet the Safety Integrity Level (SIL) requirements of IEC 61508 and IEC 61511. The SIL rating can only be determined by considering the complete safety system. The Detcon 700 series sensor modules are designed with this in mind and feature a new and unmatched level of preemptive fault diagnostics. Application variables like input voltage range, operating temperature range, maintenance schedule, detector reliability and output integrity are all monitored and reported via the 4-20 ma and RS-485 serial output. As a component of a SIL rated system, the Safe Failure Fraction (SFF) of Detcon Model Series 700 sensors meet the requirements for any SIL 2 rated system. Model Series 700 sensors utilize six distinctive gas detection technologies to satisfy a wide range of industrial applications that require monitoring of oxygen, toxic and flammable gases. Sensors for Hydrogen Sulfide CHEMFET MOS Solid State Technology Harsh and Extreme Locations Wide Temperature & Humidity Range 10-year Sensor Warranty Sensors for Combustible Gas Catalytic Technology Non-selective Combustible Gas Detector 3 to 5 Year Life Expectancy Rugged Construction Electrochemical Technology Long Term Calibration Stability Low Power Consumption Infrared Technology Combustible Hydrocarbon Gas Detector 5-Year Warranty Self Diagnostic Optical Detector Sensors for Toxic Gases Electrochemical Technology Long Term Calibration Stability Low Power Consumption Photo Ionization Technology Universal Non-Selective VOC Sensor Miniature Plug-in Detector Oxygen Sensors Electrochemical Technology Embedded Temperature Compensation 2-year Sensor Warranty

A natomy of a Model 700 Series Sensor Assembly 4-20 ma output 2-Way Digital communication RS-485 Modbus serial output Power 11.5-28 VDC 3/4" NPT Thread Fully Epoxy Encapsulated Circuitry Eliminates failures due to water ingress and corrosion Microprocessor Controlled Circuitry With advanced level of I/O protection Corrosion Resistant Electropolished 316SS sensor housing Viewing Lens and Display 4 character alpha-numeric LED display. Displays reading & status and supports user interface Internal Magnetic Programming Non-intrusive and simplified operator interface via handheld magnet. Plug-in Replaceable Gas Sensors Catalytic Bead, IR, Solid State H2S, Electrochemical, O2, PID Corrosion-Resistant Lower Housing Electropolished 316 SS threaded housing for quick release. Harsh Environment Splashguard Integral Calibration Port

Technology Features Environmentally Bulletproof Electropolished 316SS Construction 100% Epoxy Encapsulated Circuitry Bullet-Proof I/O Protection Over-voltage Miswiring EMI/RFI Immunity Water-Proof, Corrosion-Proof PCB Oversized Gold Plated Mating Pins Modular and Serviceable Modular Design Plug and Play Components Limited Spare Parts Universal Design Concept Quick Thread Release For Sensor Replacement Integral Calibration Port Main Housing Lower Housing Plug-in Sensor Splashguard Failsafe User-Friendly Interface LED Display With Antiglare Cover Full Text Display Method Non-intrusive Interface Scrolling Full Message/Text Display PGM1 PGM2 ZERO SPAN Pre-emptive Fault Diagnostics input voltage range Auto Zero/Auto Span Sequence 0% operating temperature Range Detector signal amplitude output signal loop integrity RS-485 Output Auto zero zero cal auto span apply 50% LEL span ok sensor life 100% remove gas span complete

Installation & Integration Options Model Series 700 gas detectors provide the end-user with a wide variety of output & integration options. The standard intelligent sensor module features an industry standard 4-20 ma output and a RS-485 MODBUS RTU interface. These outputs can be used simultaneously. Additional integration options include a Remote Display/Relay module and communication interface modules for HART, Foundation Fieldbus, Modbus TCP and, Profibus. Shown below are some typical system integration approaches. 4-20 ma Model 612-N1 Model 410-N1 4-20 ma Detcon Alarm Station Relays Serial Input Model 440-N4X Detcon Alarm Station RS-485 Relays Redundant Interface - 4-20 ma & Serial Model 880 PLC Controller RS-232, RS-485, Ethernet 4-20 ma Detcon Alarm Station RS-485 Relays Wide Range DCS/DAS Integration Options Alarm Relay Hart Profibus Ethernet Foundation Fieldbus Wireless Interface

O rdering Information Combustible Gas Sensor (matched pair catalytic bead) FP-700 Combustible Gas 0-100 % LEL -40 C to +75 C 2 Years Hydrogen Sulfide Gas Sensor (solid state metal oxide semiconductor) TP-700 Hydrogen Sulfide/H2S 0-100 ppm -40 C to +75 C 10 Year conditional Oxygen Gas Sensor (galvanic metal air battery) DM-700-O2 Oxygen/O2 0-25 % -20 C to +50 C 2 Years Combustible Hydrocarbon & Carbon Dioxide Gas Sensors (non-dispersive infrared optical - NDIR) IR-700-CH Combustible Hydrocarbons 0-100 % LEL -40 C to +75 C 5 Years pro-rated IR-700-CO2 Carbon Dioxide/CO2 0-3 % -40 C to +75 C 5 Years pro-rated Volatile Organic Compound (VOC) Gas Sensors (photo ionization detector - PID) PI-700-VOC Volatile Organic Compounds 0-10 ppm -20 C to +50 C 6 Months PI-701-VOC Volatile Organic Compounds 0-1,000 ppm -20 C to +50 C 6 Months Toxic Gas Sensors (electrochemical fuel cell) DM-700-C2H3O Acetaldehyde/C2H3O 0-100 ppm 20 C to +50 C 2 Years DM-700-C2H2 Acetylene/C2H2 0-100 ppm 20 C to +50 C 2 Years DM-700-C3H3N Acrylonitrile/C3H3N 0-100 ppm 20 C to +50 C 2 Years DM-702-NH3 Ammonia/NH3 0-100 ppm 40 C to +50 C 2 Years DM-700-AsH3 Arsine/AsH3 0-1 ppm 20 C to +40 C 1 1/2 Years DM-700-Br2 Bromine/Br2 0-5 ppm 20 C to +50 C 2 Years DM-700-C4H6 Butadiene/C4H6 0-100 ppm 20 C to +50 C 2 Years DM-700-CS2 Carbon Disulfide/CS2 0-100 ppm 20 C to +50 C 2 Years DM-700-CO Carbon Monoxide/CO 0-100 ppm 40 C to +50 C 3 Years DM-700-COS Carbonyl Sulfide/COS 0-100 ppm 20 C to +50 C 2 Years DM-700-Cl2 Chlorine/Cl2 0-10 ppm 20 C to +50 C 2 Years DM-701-ClO2 Chlorine Dioxide/ClO2 0-1 ppm 20 C to +50 C 2 Years DM-700-B2H6 Diborane/B2H6 0-5 ppm 20 C to +40 C 1 1/2 Years DM-700-C2H6S Dimethyl Sulfide/C2H6S 0-100 ppm 20 C to +50 C 2 Years DM-700-C3H5OCl Epichlorohydrin/C3H5OCl 0-100 ppm 20 C to +50 C 2 Years DM-700-C2H5OH Ethanol/C2H5OH 0-100 ppm 20 C to +50 C 2 Years DM-700-C2H5SH Ethyl Mercaptan/C2H5SH 0-100 ppm 40 C to +50 C 2 Years DM-700-C2H4 Ethylene/C2H4 0-100 ppm 20 C to +50 C 2 Years DM-700-C2H4O Ethylene Oxide/C2H4O 0-100 ppm 20 C to +50 C 2 Years DM-700-F2 Fluorine/F2 0-1 ppm 10 C to +40 C 1 1/2 Years DM-700-CH2O Formaldehyde/CH2O 0-100 ppm 20 C to +50 C 2 Years DM-700-GeH4 Germane/GeH4 0-2 ppm 20 C to +40 C 1 1/2 Years DM-700-N2H4 Hydrazine/N2H4 0-1 ppm 10 C to +40 C 1 Year DM-700-H2 Hydrogen/H2 0-100 ppm 20 C to +50 C 2 Years DM-701-H2 Hydrogen/H2 LEL 40 C to +40 C 2 Years DM-702-H2 Hydrogen/H2 0-1% 40 C to +40 C 2 Years DM-700-HBr Hydrogen Bromide/HBr 0-30 ppm 20 C to +40 C 1 1/2 Years DM-700-HCl Hydrogen Chloride/HCl 0-30 ppm 20 C to +40 C 1 1/2 Years DM-700-HCN Hydrogen Cyanide/HCN 0-30 ppm 40 C to +40 C 2 Years DM-700-HF Hydrogen Fluoride/HF 0-10 ppm 20 C to +35 C 1 Years DM-700-H2S Hydrogen Sulfide/H2S 0-100 ppm 40 C to +50 C 2 Years DM-700-CH3OH Methanol/CH3OH 0-100 ppm 20 C to +50 C 2 Years DM-700-CH3SH Methyl Mercaptan/CH3SH 0-100 ppm 40 C to +50 C 2 Years DM-700-NO Nitric Oxide/NO 0-100 ppm 20 C to +50 C 3 Years DM-700-NO2 Nitrogen Dioxide/NO2 0-10 ppm 20 C to +50 C 2 Years DM-700-O3 Ozone/O3 0-1 ppm 10 C to +40 C 2 Years DM-700-COCl2 Phosgene/COCl2 0-1 ppm 20 C to +40 C 1 1/2 Years DM-700-PH3 Phosphine/PH3 0-5 ppm 20 C to +40 C 1 1/2 Years DM-700-SiH4 Silane/SiH4 0-50 ppm 20 C to +40 C 1 1/2 Years DM-700-SO2 Sulfur Dioxide/SO2 0-20 ppm 20 C to +50 C 2 Years DM-700-C4H8S Tetrahydrothiophene/C4H8S 0-100 ppm 10 C to +40 C 2 Years DM-700-C4H4S Thiophane/C4H4S 0-100 ppm 20 C to +50 C 2 Years DM-700-C4H6O2 Vinyl Acetate/C4H6O2 0-100 ppm 20 C to +50 C 2 Years DM-700-C2H3Cl Vinyl Chloride/C2H3Cl 0-100 ppm 20 C to +50 C 2 Years Accessories Description Part Number NEMA 7 aluminum terminal J-box with solid cover - 3 Port 897-850000-000 NEMA 7 316 stainless steel terminal J-box with solid cover - 3 Port 897-850000-316 *Standard Range - contact factory for other ranges. **Replaceable plug-in sensor. Contact the factory for other gases not on this list. Cross sensitivity data available on request. Specifications Common Specifications Input Voltage 11.5-28 VDC standard Power Consumption <2 watts typical Outputs Linear 4-20 ma DC RS-485 Modbus -RTU Electrical Classification Explosion Proof Class I, Division 1, Groups B, C, D Class I, Zone 1, Group IIC Safety Approvals (pending) CSA/NRTL (US OSHA Certified) ATEX Dimensions 7" High x 2 1/8" Diameter Weight 2 Lbs Functional Safety Rating Designed in Accordance with IEC 61508/61511 as a SIL 2 safety system component Technology Specifications Accuracy/Repeatability FP-700: ±3% 0-50% LEL; ±5% 50-100% TP-700: ±10% of reading or ±2 ppm (greater of) DM-700-O2: ±2% full scale IR-700-CH: ±3% 0-50% LEL; ±5% 50-100% LEL IR-700-CO2: ±5% full scale PI-700: ±10% of reading; ±2.5% of range (greater of) DM-700 (toxics): ±2% full scale Response/Clearing Time FP-700: T50 <10 seconds; T90 <30 seconds TP-700: T50 <30 seconds; T80 <60 seconds DM-700-O2: T90 <20 seconds IR-700-CH: T50 <10 seconds; T90 <30 seconds IR-700-CO2: T50 <15 seconds; T90 <40 seconds PI-700: T50 <10 seconds; T90 <30 seconds DM-700 (toxics): Contact factory for specific gases Operating Humidity Range (Continuous) FP-700: 0-99% RH non-condensing TP-700: 0-99% RH non-condensing DM-700-O2: 0-99% RH non-condensing IR-700-CH: 0-99% RH non-condensing IR-700-CO2: 0-99% RH non-condensing PI-700: 0-100% non-condensing DM-700 (toxics): typically 10-90% RH contact factory for specific gases Warranty Detcon Inc. warrants each new Model 700 Intelligent Sensor to be free from defects in material and workmanship under intended normal use for a period of two years from the date of shipment to the original purchaser. Detcon warrants each new plug-in replaceable sensor to be free from defects in material and workmanship under intended normal use for the period described in the table on the left. All warranties are FOB the Detcon factory located in The Woodlands, Texas, USA.