HERZ Differential Pressure Control Valve 4002

Similar documents
HERZ Regulating valve 4002

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

TS RD 7761 RD, 7761 RD

Brawa-Mix Thermostatic mixing valves

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Say heating. Say Herz. HERZ-Supply Engineering

Thermostatic valve bodies

Mikrotherm. Manual Radiator Valves With presetting

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Multilux 4-Eclipse-Set

Thermostatic valves with radiator connection systems

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Control valves for floor heating systems. Floor Heating Manifolds

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Standard. thermostatic valve body without presetting

CALIS-TS-3-D. HERZ Armaturen. Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Three-Way Valves in 3-D Design for One-Pipe Systems

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Three-way reversing valve

IMI Heimeier Kit Hydroca ble

Regulux. Radiator lockshield with drain-off facility. To be precise.

Thermostatic valve bodies

Automatic balancing valves ASV-PV (new generation) DN 32-50

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Partner Valve/High Quality Ball Valve LENO MSV-S

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Flush individual room control for floor heating systems

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

manifold, for radiators

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Radiator valve inserts

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

Valves, controls + systems Flow, pressure and temperature balancing

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Floor Control Set. Floor Heating Controller For constant control of the supply temperature

thermostatic valve body with stepless precision presetting

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Distributors for Floor Heating Systems

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

TECHNICAL DATA. Wet 26a. February 22, 2009

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

TA-Compact-P. Giving you MORE by giving you LESS

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

PrimusCenter DWC7000. Domestic Water Centre. Product specification sheet

Systems for central heating

CATALOGUE NUMBERS. Pressure Reducing Valve (PRV)** Mains Supply. Cold Water Outlets

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

Radiator Trap Radiator Valve

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Indirect Expansion. USER MANUAL FOR OPERATORS AND PLUMBERS HEAT INTERFACE UNITS

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

Thermostatic mixing valves with interchangeable cartridges

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Heating Controls Thermostatic and Manual Radiator Valve range

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Chemical Pumps Vertical Chemical Pump Type TNP

product overview ProControl

PROMAX XL MODELS CIRCULATING LOOP HEAT EXCHANGER MANUAL. Installation. Operation. Maintenance. Fill in the Rating Pate Information Here:

SECTION REFRIGERANT PIPING

Temperature controller for steam (PN 25) AVT / VGS - external thread

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

DISCALDIRT deaerator-dirt separator

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Transcription:

HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002 64 1 4002 74 1 4002 45 1 4002 65 1 4002 75 1 4002 46 1 4002 66 1 4002 76 DN G L H1 H2 B B1 B2 15 3/4 G 66 133 28 95 26 29 20 1 G 76 134 29 95 28 30 25 1 1/4 flatsealing 76 134 29 95 28 30 32 1½ flatsealing 114 150 47 95 40 1¾ flatsealing 132 160 55 95 50 2 3 8 flatsealing 140 160 55 94 Technical data max. operating pressure 16 bar max. differential pressure 2 bar (body/diaphragm) min. operating temperature 2 C (pure water) min. operating temperature - 20 C (frost protection) max. operating temperature up to DN 32 130 C from DN 40 110 C DP Range 4002 4x 5-30 kpa DP Range 4002 6x 25-60 kpa DP Range 4002 7x 45-80 kpa Important note: The capillary must be connected when you make pressure tests and any isolating valves (1 0269 09, 1 4007 78,...) in the capillary must be open. During flushing, capillary isolating valves should be shut to prevent the valve from attempting to regulate the flow. To prevent damage of the body and the diaphragm a maximum differential pressure of 2 bar between supply and return is allowed at all times. Page 1

Application The differential pressure controller is a straight-version linear controller and works without auxiliary power. The nominal differential pressure can be continuously adjusted from 50 to 300 mbar and 250 to 600 mbar, respectively. The value for the setting can be read from the diagram. The nominal set point is factory preset to a minimum. If necessary, the nominal set point can be adjusted using the pre-setting key (1 4002 01). A capillary (1000 mm) is included and should be connected to the circuit regulating valve in the flow. Materials Body: dezincification-resistant brass Membranes and O-rings: EPDM Water purity in accordance with the ÖNORM H 5195 and VDI 2035 standards Ethylene and propylene glycol can be mixed to a ratio of 25-50 vol. [%] EPDM gaskets can be affected by Mineral oils lubricants and thus lead to failure of the EPDM seals. Please refer to manufacturers documentation when using ethylene glycol products for frost and corrosion protection Installation The valve is fitted in the return flow in any orientation. The arrow on the valve body should align with the direction of flow. It is recommended that an isolation valve is fitted both upstream and downstream of the differential pressure controller kv values DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 4002 2,66 4,36 5,38 9,48 14,95 14,95 Page 2

Connection elements 1 6220.. Iron pipe connection, consisting of nut, seal and pipe nipple with male pipe thread 1 6236.. Soldering connection, consisting of nut, seal and soldering nipple 1 6240.. Welding connection, consisting of nut, seal and welding nipple 1 6210.. Iron pipe connection consisting of nut, seal and pipe nipple with male pipe thread 1 6235.. Soldering connection, consisting of nut, seal and soldering nipple Tips The valves must be installed for the correct application using clean fittings. A HERZ strainer (4111) should be fitted to prevent impurities.. Test points Two test points are fitted on the same side of the valve and factory sealed. Thanks to this arrangement they are easily accessible and measurement devices can be quickly fitted, no matter in what position the valve has been installed. Pre-setting The valve setting is clearly shown on the scale on the valve indicator. The preset value can be easily adjusted. Once set, the differential pressure controller can always be adjusted to any position. Application examples Please note: all diagrams are indicative in nature and do not claim to be complete. Page 3

HERZ-Connection elements R D R Ø L L 6210/6211 6235 R D R Ø R Ø L 6220/6221 L 6236 L 6240/6241 Valve dimension Order number R D ø L DN 15 1 6210 21 3/4 1/2 25 DN 15 1 6210 26 3/4 1/2 21 DN 15 1 6210 11 3/4 1/2 30 DN 15 1 6211 00 3/4 3/8 24 DN 20 1 6210 02 1 3/4 30 DN 20 1 6210 12 1 1/2 30 DN 25 1 6220 63 1¼ 1 35 DN 32 1 6220 64 1½ 1 40 DN 40 1 6220 65 1¾ 1½ 49 DN 50 1 6220 66 2¾8 2 56 DN 15 1 6235 21 3/4 12 13 DN 15 1 6235 31 3/4 15 13 DN 15 1 6235 41 3/4 18 18 DN 20 1 6235 12 1 18 18 DN 25 1 6236 63 1¼ 28 24 DN 32 1 6236 64 1½ 35 27 DN 40 1 6236 65 1¾ 42 31 DN 50 1 6236 66 2¾8 54 37 DN 25 1 6240 63 1¼ 34 51 DN 32 1 6240 64 1½ 42 54 DN 40 1 6240 65 1¾ 48 57 DN 50 1 6240 66 2¾8 60 60 B A L Valve dimension Order number A B L DN 15 P 7014 81 G 3/4 14 x 2 50 DN 15 P 7016 81 G 3/4 16 x 2 50 DN 15 P 7018 81 G 3/4 18 x 2 50 DN 15 P 7020 81 G 3/4 20 x 2 50 DN 25 P 7026 43 G 1¼ 26 x 3 50 DN 25 P 7032 43 G 1¼ 32 x 3 50 DN 25 P 7040 43 G 1¼ 40 x 3,5 70 DN 32 P 7032 44 G 1½ 32 x 3 50 DN 32 P 7040 44 G 1½ 40 x 3,5 70 DN 32 P 7050 44 G 1½ 50 x 4 70 Page 4

Accessories and spare parts 1 4117 xx HERZ-STRÖMAX circuit control valves, angle version 1 4217 xx HERZ- STRÖMAX circuit control valves, straight version 1 4017 xx HERZ- STRÖMAX circuit control valves with integrated metering orifice plate 1 4125 xx HERZ shut-off valves, angle version 1 4115 xx HERZ shut-off valves, angle version 1 4215 xx HERZ shut-off valves, straight version, also variants with male threads. For details please refer to the corresponding data sheets. 1 0284 01 test point for HERZ circuit control valve, blue cap (return) 1 0284 02 test point for HERZ circuit control valve, red cap (flow) 1 0284 11 test point for HERZ circuit control valve, extended model, blue cap (return) 1 0284 12 test point for HERZ circuit control valve, extended model, red cap (flow) 1 0284 21 HERZ test point with draining function, blue cap (return) 1 0284 22 HERZ test point with draining function, red cap (flow) 1 0284 00 test point adapter set 1 0273 09 screw plug 1/4 1 4006 02 HERZ pre-setting key for differential pressure control 1 4002 78 control capillary with ball valve G 1/8 1 4002 80 control capillary with connections G 1/4 length 2000 mm 1 4096 1x Insulation shell made of EPP (expanded polypropylene) According to DIN 4102 and E after DIN EN 13501-1 Weight 45 kg/m³ A B C Order number DN A B C 1 4095 11 15 96 78,5 75 1 4095 12 20 110 82 83 1 4095 13 25 112 84 100 1 4095 14 32 152 120 110 1 4095 15 40 170 130 123 1 4095 16 50 179 130,5 147 Page 5

Dimensioning Example: required differential pressure 400 mbar flow rate 1000 l/h preset at position 4 Use the flow chart to determine the preset position for the valve, in the example below it can be clearly seen that the preset position is 4.0 Durchfluss [l/h] dp [mbar] Page 6

Art. Nr. 1 4002 41 Dim. DN 15 Page 7

Art. Nr. 1 4002 61 Dim. DN 15 Page 8

Art. Nr. 1 4002 71 Dim. DN 15 Page 9

Art. Nr. 1 4002 42 Dim. DN 20 Page 10

Art. Nr. 1 4002 62 Dim. DN 20 Page 11

Art. Nr. 1 4002 72 Dim. DN 20 Page 12

Art. Nr. 1 4002 43 Dim. DN 25 Page 13

Art. Nr. 1 4002 63 Dim. DN 25 Page 14

Art. Nr. 1 4002 73 Dim. DN 25 Page 15

Art. Nr. 1 4002 44 Dim. DN 32 400 350 300 250 200 150 100 50 0 Page 16

Art. Nr. 1 4002 64 Dim. DN 32 1000 900 800 700 600 500 400 300 200 100 0 Page 17

Art. Nr. 1 4002 74 Dim. DN 32 Page 18

Art. Nr. 1 4002 45 Dim. DN 40 Page 19

Art. Nr. 1 4002 65 Dim. DN 40 Page 20

Art. Nr. 1 4002 75 Dim. DN 40 Page 21

Art. Nr. 1 4002 46 Dim. DN 50 Page 22

Art. Nr. 1 4002 66 Dim. DN 50 Page 23

Art. Nr. 1 4002 76 Dim. DN 50 Page 24