Are you still stuck with the current status of manual thermometer recording? X Labor Intensive X No History X Inaccurate

Similar documents
WHO PQS-Code E006/020. Fridge-tag 2 Storage temperature monitor with USB port

Q-tag CLm doc family Type: doc / doc L / doc LR / doc D

WHO PQS-Code E006/016. Q-tag CLm doc USB Multi- Limit Temperature Indicator

Fridge-tag 2 L. with external sensor OPERATION MANUAL

NYS Vaccines for Children (VFC) Program Fridge-Tag 2L Data Logger: Implementation and User Guide

Fridge-tag 2 L OPERATION MANUAL ENGLISH PAGE 1-34 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Refrigerator/Freezer Thermometer

Refrigerator/Freezer Thermometer

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-34 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor

Vaccine Storage and Handling Training. Onondaga County Health Department November 2012

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

BIOMEDICAL REFRIGERATORS

MIRADOR Real Time Monitoring

THERMOMETERS Dataloggers/Refrigerator

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

Vaccine Storage and Handling Studies at NIST

Electrolux Reseller FAQs

Daily Refrigerator Medication Temperature Log Template

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

The Ultimate Guide to Vaccine Storage. TrueBlue.

SENSOSCIENTIFIC DATA LOGGER USER MANUAL V

Stability Chambers & Rooms

Patriot Systems Limited

STUDY AND TEST MATERIAL FOR THE. FA2 and FA4 ASSESSMENTS. (Fire Alarm On-Site and Business Cert. Holder) June 14, 2017

What's new in LogTag Analyzer 2.8

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Avigilon Control Center 5 System Integration Guide

LogTag TICT - is0 Tag

iminiplus PDF User Guide Version 2.0

PHD Dolphin Installation

InTemp CX Temperature Logger (CX40x) Manual

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

3D_ISS. Integrated Software System. User Guide Manual


USER MANUAL USB Multi-Function Datalogger Model RHT35

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

AirTest Technologies Inc.

The 6 Most Important Parts of a Temperature Monitoring System

EL-USB-1-LCD Temperature Data Logger with LCD

Avigilon Control Center System Integration Guide

Ontech GSM 9040/50. Reference Manual English -1 -

Refrigerator Temperature Chart

LineGuard 2300 Program User Manual (FloBoss 107)

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

Avigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1

2014, TempSen Electronics Company

Static Pressure Control

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Installing ProSeries software for stand-alone use

Contacting Onset Mailing Address: Phone: Fax: Hours of Operation: E mail: Main Onset Web site: Copyrights and Trademarks

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Follett Performance Plus

Alarm Management Implementation on a Plant. Standards Certification Education & Training Publishing Conferences & Exhibits

User manual. Epi-Care mobile. Danish Care Technology ApS Energivej 3, DK-4180 Sorø version 1.15 Phone: Page 1 of 17

Vaccine Storage Safeguarding with the Refrigerator/Freezer Guard

PQS Quality Assurance protocol. TITLE: Cold Room/Freezer Room:

Avigilon Control Center System Integration Guide

Recording Server PRELOADED

Tri-Tech Medical Inc.

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Patriot Systems Limited

FFT Functional Family Therapy Evidence Based. Cost Effective. Sustainable. Family, Youth & Culture Sensitive.

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Refrigerated Incubator Model and Operating Instructions

Temperature Monitoring System. Specifications

Avigilon Control Center 5 System Integration Guide

Dual Probe Vaccine Temperature Data Logger w/ Software-Less Reporting

ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers

Refrigerator/Freezer Guard Models VM605, VM605E. Property Guard Models VM610, VM610E. Temperature Monitor and Alarm

ISO 6394 INTERNATIONAL STANDARD

MicroTech Series 200 Centrifugal Chiller

Med Touch Master Alarm

WebAlert WA500 Series Process Monitor Instruction Manual

Dew point set DS 400

Specifications Minimum Typical Maximum Unit

flexibility programmed settings.

BRS Mechanically-Agitated BioReactor MA 100. Quick Reference Guide Ver2.0

UTRED day Logger with display

[ [ ADMIN PANEL USER GUIDE

Synergy Controller Application Note 125 January 2016, Revision A Tidal Engineering Corporation 2016

Bosch TCU Integration Module Administrator's Guide

Ion Gateway Cellular Gateway and Wireless Sensors

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

PBI Manual. Paradox to KNX-BUS Interface

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

Blood bank refrigerators

Exceptional data integrity. Complete peace of mind.

REBATE. Ductless Mini-Split Heat Pump

Tri-Tech Medical Inc.

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

Platform Services BACnet Alarm Management

TABLE OF CONTENTS. Your Northwood Intouch Unit (Diagram)...1. How to use your Emergency Response System... 2

Step 1 - Install ProSeries Basic software

Alarm Coordination Connected Components Building Block. Quick Start

Transcription:

Fridge-tag 2 Current Status Are you still stuck with the current status of manual thermometer recording? X Labor Intensive X No History X Inaccurate Future State with The Fridge-tag 2 The future is here with the Fridge-tag 2! Automated Report Generation Visible Alarm Notification ISO 17025 Certificate of Calibration

Why is temperature important?

Current State Today Data is lost every day Manually read & record daily No memory Temperature accuracy typically +/- 1.0c

Why temperature monitoring recommendations changed Interpreting CDC recommendations

Why temperature monitoring recommendations changed Twice daily monitoring only is insufficient and ineffective Reports of temperature abused vaccine brought attention to the issue OIG report confirmed issue and provided independent data Without a continuous temperature monitoring system the likelihood of undiscovered temperature excursions occurring is high

Why should a doctor/provider use a data logger? Continuous temperature information Assuring vaccine potency Protect ALL vaccines including the most vulnerable Problems? You have the information! Because ultimately it makes patient care easier, more efficient and safer

What VFC Coordinators Like Training & Support Experience No Software Berlinger = manufacturer Be ready for the future

What VFC Coordinators Like Training & Support Experience Web training: DPH staff & providers Useful videos: quick reminders On-line tools Customer service line

What VFC Coordinators Like No Software 30% of providers cannot download software 100% of providers confused by software: logging interval/alarms Factory set alarms- standard or custom alarms

What VFC Coordinators Like Berlinger = manufacturer We listen & we adapt product features to changing requirements We work thru local & national approved distributor vendors If you need something and don t see it in this presentation, ask for it we change

What VFC Coordinators Like Be ready for the future More reporting features planned for 2016 Building a database for these files? Ask about our data storage OR how to use the raw data file to connect with your data base easily We own the company so we make products you want!

What the instructions look like

Easy Instructions

On-line Video Help Back Sticker

Fridge-tag 2: Read report Download the report

Plug into Any Computer Fridge-tag 2

Click on Folder Like Any Removable Memory Stick

Then Click the PDF

Fridge-tag 2: Read the report PDF document of the Fridge-tag 2 Identification number: BBBA00073 Date and time of report creation: 03/31/2014 08:07h Upper alarm limit: Lower alarm limit: Above +8ºC for 60 min Below +2ºC for 15 min Lower alarm limit Upper alarm limit Ext. sensor connection error No Date Events* Average Status Min Duration Alarm Alarm Status Max Temp. Duration Alarm Alarm Status Duration Alarm Signature/notes (mm.dd.yyyy) temp. temp. out of trigger ambient out of trigger ambient trigger range time temp. range time temp. time 1 Today am +4.6 In progress +3.6 OK +5.5 In progress 2 3/30/14 +4.6 ok +3.6 OK +5.6 ok 3 3/29/14 am,pm +3.7 ok +2.9 OK +4.5 ok 4 3/28/14 am,pm +3.2 ok +2.3 OK +4.1 ok 5 3/27/14 am,pm +3.3 ok +2.5 OK +4.1 ok 6 3/26/14 am,pm +2.8 ALARM +1.7 1h 15 min 18:30 +25.3 OK +3.8 ok 2min 7 3/25/14 am,pm +5.4 ok +4.1 OK +6.6 ok 8 3/24/14 am,pm +5.6 ok +4.4 OK +6.7 ok 3min 9 3/23/14 +5.5 ok +4.0 OK +6.9 ok 10 3/22/14 am,pm +5.7 ok +4.3 OK +7.0 ok 11 3/21/14 am,pm +5.8 ok +4.3 OK +7.2 ok 12 3/20/14 am,pm +5.8 ok +4.1 OK +7.4 ok 13 3/19/14 am,pm +5.7 ok +3.9 OK +7.5 ok 14 3/18/14 am,pm +5.8 ok +3.9 OK +7.7 ok 15 3/17/14 am,pm +7.1 ok +3.7 ALARM +12.0 3h 52 min 19:12 +23.7 ok 4min Sample Monthly Report

Fridge-tag 2: Read the report 2 Year Calibration Tracks when READ button is pressed: 2x day temp. checks

Fridge-tag 2: Read the report

Fridge-tag 2: Read the report

Fridge-tag 2: Read the report PDF document of the Fridge-tag 2 Identification number: BBBA00073 Date and time of report creation: 03/31/2014 08:07h Upper alarm limit: Lower alarm limit: Above +8ºC for 60 min Below +2ºC for 15 min Lower alarm limit Upper alarm limit Ext. sensor connection error No Date Events* Average Status Min Duration Alarm Alarm Status Max Temp. Duration Alarm Alarm Status Duration Alarm Signature/notes (mm.dd.yyyy) temp. temp. out of trigger ambient out of trigger ambient trigger range time temp. range time temp. time 1 Today am +4.6 In progress +3.6 OK +5.5 In progress 2 3/30/14 +4.6 ok +3.6 OK +5.6 ok 3 3/29/14 am,pm +3.7 ok +2.9 OK +4.5 ok 4 3/28/14 am,pm +3.2 ok +2.3 OK +4.1 ok 5 3/27/14 am,pm +3.3 ok +2.5 OK +4.1 ok 6 3/26/14 am,pm +2.8 ALARM +1.7 1h 15 min 18:30 +25.3 OK +3.8 ok 2min 7 3/25/14 am,pm +5.4 ok +4.1 OK +6.6 ok 8 3/24/14 am,pm +5.6 ok +4.4 OK +6.7 ok 3min 9 3/23/14 +5.5 ok +4.0 OK +6.9 ok 10 3/22/14 am,pm +5.7 ok +4.3 OK +7.0 ok 11 3/21/14 am,pm +5.8 ok +4.3 OK +7.2 ok 12 3/20/14 am,pm +5.8 ok +4.1 OK +7.4 ok 13 3/19/14 am,pm +5.7 ok +3.9 OK +7.5 ok 14 3/18/14 am,pm +5.8 ok +3.9 OK +7.7 ok 15 3/17/14 am,pm +7.1 ok +3.7 ALARM +12.0 3h 52 min 19:12 +23.7 ok 4min Sample Monthly Report

Take the plunge this summer

Take the plunge this summer TRY A FREE FRIDGE-TAG 2 STATE VFC ORGANIZATIONS ONLY Valid until 8/14/15 Answer 4 questions @ www.berlingerusa.com/testdrive Agree to provide feedback in a telephone Q&A

VFC Mass Vaccination Clinics CLm doc LR = Reusable data logger Easy to monitor: OK = Not OK = X One button push: No software INFO = current temp every hour & mark report to prove it was checked No software

What users say We don t even think about tracking temperatures anymore we can see so clearly if there is ever an issue,we can t miss it It s so easy to make the report This is the first time I had 24/7 documentation to save my vaccines from a power outage. Now I need one for my other refrigerator & freezer It took me about 5 minutes to figure out how to use it now everything runs smoothly

Global Reach Distribution Partner Canada Berlinger AG Global HQ Ganterschwil, CH Distribution Partner Russia Distribution Partner India Berlinger USA Westborough, MA, USA Distribution Partner Japan Distribution Partner To Be Announce

Products built for you Patrick McGrath General Manager 508-366-0084 patrick.mcgrath@berlinger.ch Next Steps: Try a free unit take the plunge Bring decision team together for a capabilities review 222 Turnpike Road Westborough, MA 01581 USA Info.us@berlinger.ch www.berlinger.com

Fridge-tag 2 Data output via USB ASCII Files PDF File

Fridge-Tag 2

Berlinger Overview 6th Generation, private owner Andrea Berlinger: President ISO 9001 & 14,001 Certificate Global Operations Long-term stable growth year over year