TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

Similar documents
TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

SPLIT SYSTEM AIR CONDITIONER

SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: ASR609CL ASR612CL ASR609CL ASR612CL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: MCAF72R5TA- MCAF92R5TA- MCAF122R5TA-

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

TECHNICAL & SERVICE MANUAL SAP K181A + SAP C181A

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL MULTI-SPLIT SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K303A + SAP C303A FILE NO. REFERENCE NO. SM Destination: Australia

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER SAP K301AH + SAP C301AH FILE NO. SAP K301AH SAP C301AH REFERENCE NO.

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity 7,500BTU / h 9,000BTU / h 11,900BTU / h 17,500BTU / h 24,200BTU / h

MULTI-SPLIT SYSTEM AIR CONDITIONER

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

Service Manual. Compact Series REFRIGERANT R407C R22 COOLING ONLY HEAT PUMP. Indoor Units Outdoor Units IOD 7 CON 7 IOD 9 CON 9 IOD 12 CON 12

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

Item No. (Standard/Opposite Hand) /

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Fast Track Troubleshooting

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

DESIGN & TECHNICAL MANUAL

INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Technical manual NIBE AG-AA10 Single split air to air heat pump

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

Fast Track Troubleshooting

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

Service Manual. Alpha Series REFRIGERANT R410A COOLING ONLY HEAT PUMP. Alpha 9 Alpha 17 DF. ONG3-17 (Alpha)

Fast Track Troubleshooting

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

Service Manual. LEX Series REFRIGERANT R410A COOLING ONLY HEAT PUMP. Indoor Units Outdoor Units LEX 7 ONG 7 LEX 9 ONG 9 LEX 12 ONG 12 LEX 14 ONG 14

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Digital Inverter 4 series 8 & 10HP

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

Engineering Data Manual

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

REMOTE CONTROL MANUAL

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

II PCV1 Features

MAC N-407 Air-Cooled Chiller

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

XLF Series REFRIGERANT R410A HEAT PUMP COOLING ONLY SM XLF 1-A.1 GB

Concealed Ducted Split Series R-407C MBH

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Transcription:

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245SCH2O( I ) Cooling only model ARGO 235HPH2O( I ) Heat pump model 0.8180.519.1 11 / 2007

Table of contents Page A SPECIFICATIONS 1) Unit specifications 1 3 2) Unit specifications 2 4 3) Major Component specifications 5 / 6 B OPERATING RANGE 6 C DIMENSIONAL DATA 7 D PERFORMANCE CHARTS SC and HP1 8 E PERFORMANCE CHARTS SC and HP2 9 F PERFORMANCE CHARTS heat pump1 10 G PERFORMANCE CHARTS heat pump2 11 H WATER SIDE PRESSURE DROP 12 I REFRIGERANT FLOW DIAGRAMS 13 L FUNCTIONS 1) Cool Mode Operation 14 2) Heat Mode Operation 15 3) Auto (Cool/Heat) Mode Operation 16 4) Dry Mode Operation 17 5) Fan Mode Operation 17 6) Auto Fan Speed 17 7) Forcede mode 18 8) Protection Operations in Cool and Dry Modes 18 9) Protection Operations in Operation Heat Mode 19 10) I Feel Function 21 11) Night Function 21 12) Diagnostic 22 13) Jumpers 23 14) Contacts for building automation 27 15) Maintenance 24 16) Manual Unit control and Led indicators 25 17) Ws Imput Switch 26 M ELECTRIC WIRING DIAGRAMS 27/28 N TROUBLESHOOTING 29 O REFRIGERANT CHARGE 36 P CHECKING ELECTRICAL COMPONENTS 37 1) Measurement of Insulation Resistance 37 2) Checking Continuity of Fuse on PCS Ass'y 38 3) Checking Motor Capacitor 38 Q BOILER CONNECTION KIT 39 1) Specifications and operating limits 39 2) Performance charts 40 3) Component specifications 41 4) Hydraulic connections and valves 2 42

A SPECIFICATIONS 1) UNIT SPECIFICATIONS 1 UNIT MODEL NOTE Rating conditions cooling : City water : ambient temp. 27 C d.b. / 19 C w.b.- inlet water temp.18 C - outlet 36 C. Water loop : ambient temp. 27 C d.b. / 19 C w.b. - inlet water temp. 30 C - outlet 35 C Hot-water system : ambient temp. 20 C - inlet water temp. 70 C - outlet 60 C. ARGO 245SCH2O Power source 220-240 V 50 Hz PERFORMANCES IN CITY WATER IN WATER LOOP COOLING COOLING Capacity (air BTU / h 9650 9200 conditioner) kw 2,83 2,7 Capacity (hot-water system) BTU / h kw 7160 2,1 Air circulation (high/med/low) m 3 / h 330-300-280 Water flow m 3 / h 0,165 0,575 Pressure drop kpa 2,0 32,0 Moisture removal (high speed) Cooling l / h 1,2 Dry 27 C ( 60% R.U.) liters / 24h 30 Dry 30 C (80% R.U.) liters / 24h 59 ELECTRICAL RATINGS Voltage rating V 220-240 Available voltage range V 198-264 Running Ampere (air conditioner) A 2,9 3,0 Running Ampere (hot-water system) A 0,10 Power input (air conditioner) W 640 650 Power input (hot-water system) W 27 Power factor 0,96 0,94 E.E.R. / C.O.P 4,42 4,15 Compressor locked rotor amperes A 17 FEATURES Controls / temperature control Microprocessor / I.C. Thermostat Control unit Wireless remote control unit Timer ON / OFF 24 hours and program Fan speed (air conditioner) 3 + Auto Fan speed (hot-water system) 3 Airflow direction Horizontal Auto (manual for hot water system) (Indoor) Vertical Manual Air filter Washable, easy access Compressor Rotary (hermetic) Refrig./Stand. Charge at shipment R410A 360g Refrigerant control Capillary tube Sound pressure Air conditioner Hi/Me/Lo db-a 44-42-41 level Hot-water system Hi/Me/Lo db-a 42-39-32 Water connections diameter 1/2 " Gas DIMENSIONS AND WEIGHT Height Widht Depht Net weight mm mm mm kg 735 839 260-280 46 Data can be changed without notice 3

2) UNIT SPECIFICATIONS UNIT MODEL Power source PERFORMANCES Capacity (air conditioner) Capacity (hotwater system) 220-240 V 50 Hz IN CITY WATER IN WATER LOOP COOLING HEATING COOLING HEATING BTU / h 10060 10740 10230 12140 kw 2,95 3,15 3,00 3,56 BTU / h kw 7160 2,1 m 3 / h 330-300-280 m 3 / h 0,165 0,575 Air circulation (high/med/low) Water flow Pressure drop kpa 2,0 40,0 Moisture removal (high speed Cooling l / h 1,3 -------- 1,3 -------- Dry 27 C ( 60% R.U.) liters / 24h 32 -------- 32 -------- Dry 30 C (80% R.U.) liters / 24h 61 -------- 61 -------- ELECTRICAL RATINGS Voltage rating V 220-240 Available voltage range V 198-264 Running Ampere (air conditioner) A 2,9 3,8 3,11 3,9 Running Ampere (hot-water system) A 0,10 Power input (air conditioner) W 630 830 680 860 Power input (hot-water system) W 27 Power factor 0,94 0,95 0,95 0,96 E.E.R. / C.O.P 4,68 3,8 4,41 4,14 Compressor locked rotor amperes A 17 FEATURES Controls / temperature control Microprocessor / I.C. Thermostat Control unit Wireless remote control unit Timer ON / OFF 24 hours and program Fan speed (air conditioner) Fan speed (hot-water system) Airflow Horizontal direction Vertical Air filter Compressor Refrig./Stand. Charge at shipment R410A Refrigerant control Sound Air conditioner Hi/Me/Lo db-a pressure level Hot-water system Hi/Me/Lo db-a Water connections diameter DIMENSIONS AND WEIGHT Height Widht Depht Net weight mm mm mm kg NOTE Rating conditions cooling / heating : City water cooling : ambient temp. 27 C d.b. / 19 C w.b.- inlet water temp.18 C - outlet 36 C. City water heating : ambient temp. 20 C d.b. - inlet water temp.18 C - outlet 6 C. Water loop cooling : ambient temp. 27 C d.b. / 19 C w.b. - inlet water temp. 30 C - outlet 35 C Water loop heating : ambient temp. 20 C d.b. - water temp. 15 C Hot-water system : ambient temp. 20 C - inlet water temp. 70 C - outlet 60 C. ARGO 235HPH2O 3 + Auto 3 Auto (manual for hot water system) Manual Washable, easy access Rotary (hermetic) 470g Capillary tube 44-42-41 42-39-32 1/2 " Gas 735 839 260-280 48 Data can be changed without notice 3

3) MAJOR COMPONENT SPECIFICATIONS UNIT MODEL ARGO 245SCH2O ARGO 235HPH2O CONTROLLER (PCB) Part No. Controls Control circuit fuse (F1) Jumper Setting J1.J5 (see Electric waring diagram) SWITCH INDICATOR ASSY Model Led color REMOTE CONTROL UNIT THERMISTOR (COIL SENSOR) TH1 Resistance (at 25 C) kω THERMISTOR (ROOM SENSOR) TH2 Resistance (at 25 C) kω FAN & FAN MOTOR (FMI) Model Number / Diameter / Lenght mm No. of pole / rpm (230 V, high) Nominal input W Coil resistance (at 25 C) Ω Safety device Open Setting Close Run capacitor (C2) COMPRESSOR (CM) Model Nominal cooling capacity Compressor oil RB68A or Freol Alpha68M Coil resistance (at 20 C) Run capacitor (C1) Overload relay (OLR) Operating Open temperature Close Operating amp. (Ambient temp. 25 C) C µf VAC W cc Ω Ω µf VAC C C SAC ON-OFF IDU Microprocessor 250VAC - 5A -T 2,54mm - 3 pcs 2,54mm - 2 pcs PCB 384208021 TMR : blu - STB : yellow - OPR : green RC-7 (ST) RC-7 (RC) NTC (with brass pipe) 10 ± 3% 10 ± 5% K35406-MO2024 Cross-flow 1 / Ø100 / 515 4 / 1350 30 GRY-WHT: 545 630 WHT-VLT: 92 105 VLT-ORG: 62 71 GRY-BRN: 78 90 (Internal bimetallic type) 150 ± 10K Autoreset 1,5 440 Rotary ( Hermetic) 5PS102EAA 2350 350 C-R : 3.863 C-S : 3.309 30 450 External 148 ± 5 C 69 ± 9 C Trip in 6 to 16 sec. at 16A 4

UNIT MODEL ARGO 245SCH2O ARGO 235HPH2O FLAP MOTOR (FLP) Model Rating Coil resistence (Ambient temp. 25 C) Ω 4 WAYS VALVE (20S) Model Coil rating Coil resistence (Ambient temp. 20 C) Ω HEAT EXCHANGER COIL Coil Rows Fin pitch mm Face area m 2 PLATE EXCHANGER Model Plate N Gas connections Øi mm Water connections Øi mm SOLENOID VALVE Model Coil resistance (at 20 C) Ω Rating C Nominal input FLOW SWITCH Model Water flow rate( ON ) l / min Water flow rate( OFF ) Reed switch features : HIGH PRESSURE SWITCH OPERATING PRESSURE SETTING Contact rating l / min V W bar MP24GA1 DC 12V WHT-BLU (respectively 4 wires) : 380 ± 7% --- --- --- Aluminium plate fin / copper tube 3 1,6 0,107 S09 14 20 9,6 14,3 1132/04A6 1050 220-230VAC~50Hz 68mA CH23 IT 2 1,2 250 VAC-200 VDC 30 SQ-136 AC 220V, 50 Hz, 6W 1440 ± 5% OFF ON 42 ± 1 33 ± 1,5 250 V - 6A B OPERATING RANGE Cooling only model Cooling Dry Heat pump model Cooling Heating Dry Temperature Maximum Minimum Maximum Minimum Temperature Maximum Minimum Maximum Minimum Maximum Minimum Indoor air intake temp. 32 C DB/ 23 C WB 19 C DB/ 14 C WB 32 C BS/ 80% R.U. 16 C BS/ 80% R.U. Indoor air intake temp. 32 C DB/ 23 C WB 19 C DB/ 14 C WB 27 C DB // 32 C BS/ 80% R.U. 16 C BS/ 80% R.U. 5

C DIMENSIONAL DATA 6

D ARGO 245SCH2O Cooling model ARGO 235HPH2O Heat pump model Conditions: Power source 230 V - 1-50 Hz - Single phase Indoor air velocity High speed Cooling characteristics Indoor relative humidity 48% Capacity (%) COOLING CAPACITY 120 115 110 105 100 95 90 85 Tamb 19 C 80 Tamb 27 C 75 Tamb 32 C 70 12 15 18 21 24 INLET WATER TEMP - C Power input (%) CAPACITY - %W POWER INPUT - %W POWER INPUT 120 115 110 105 100 95 90 85 80 75 70 12 15 18 21 24 INLET WATER TEMP - C Tamb 19 C Tamb 27 C Tamb 32 C E.E.R. (%) 130 EER EER - %W/W 120 110 100 90 80 70 60 12 15 18 21 24 INLET WATER TEMP - C 7 Tamb 19 C Tamb 27 C Tamb 32 C

E PERFORMANCE CHARTS SC and HP2 ARGO 245SCH2O Cooling model ARGO 235HPH2O Heat pump model 140 MOISTURE REMOVAL MOISTURE REMOVAL - %l/h 130 120 110 100 90 80 70 60 50 40 12 15 18 21 24 INLET WATER TEMP - C Tamb 19 C Tamb 27 C Tamb 32 C 130 CORRECTION FACTOR 125 120 115 110 % 105 100 95 90 85 80 110 210 310 410 510 WATER FLOW RATE - l/h CAPACITY EER INPUT MOISTURE 8

F PERFORMANCE CHARTS heat pump1 ARGO 235HPH2O Heat pump model Conditions: Power source 230 V - 1-50 Hz - Single phase Indoor air velocity High speed Heating characteristics Indoor relative humidity 48% capacity 120 115 110 capacity - %W 105 100 95 90 Tamb 15 C Tamb 20 C Tamb 25 C 85 80 12 15 18 21 24 inlet water temp - C power input 125 120 power input - %W 115 110 105 100 95 90 Tamb 15 C Tamb 20 C Tamb 25 C 85 80 12 15 18 21 24 inlet water temp - C 9

G PERFORMANCE CHARTS heat pump2 ARGO 235HPH2O Heat pump model Heating characteristics Indoor relative humidity 48% cop 120 115 5 / 6 110 COP - %W/W 105 100 95 90 Tamb 15 C Tamb 20 C Tamb 25 C 85 80 12 15 18 21 24 inlet water temp - C correction factor 125 120 115 % 110 105 capacity power input cop 100 95 90 100 200 300 400 500 600 water flow rate -l/h 10

H WATER SIDE PRESSURE DROP ARGO 245SCH2O Cooling model ARGO 235HPH2O Heat pump model WATER SIDE PRESSURE DROP 45 4500 40 4000 35 3500 PRESSURE DROP (kpa) 30 25 20 15 10 3000 2500 2000 1500 1000 WATER PRESSURE DROP(mm c.a.) 5 500 0 0 0 100 200 300 400 500 600 700 WATER FLOW RATE(l/h) 11

I REFRIGERANT FLOW DIAGRAMS REFRIGERANT FLOW DIAGRAM AND WATER CONNECTION FOR COOLING MODEL ARGO 245SCH2O REFRIGERANT FLOW DIAGRAM AND WATER CONNECTION FOR HEAT PUMP MODEL ARGO 235HPH2O 12

GL FUNCTIONS 1 Cool Mode Operation In Cool mode, the operation of Compressor ( CM ), Solenoid Valve ( SV ) and Indoor Fan ( FMI ) are determined by the difference between the Room Temperature (RAT) and the Set Point Temperature (SPT) as in the graph above. Notes: a. In this graph, the FMI is operating in the"auto Fan Speed" setting. If the user has selcted the low, medium or high fan speed, the FMI will run constantly at that speed only. b. In addition to the value of ( RAT-SPT ), the operations of the relays are also controlled by protection delays.for example,(a) the minimum On/Off time of the ( CM ) is 3min respectively, and (b) the FMI can change speed only after it has operated at de same speed for 30sec.wen in autofan setting and 1sec. for H/M/L setting. 13

2 Heat Mode Operation The Heating mode operation is similar to the Cooling mode operation.the compressor CM,solenoid valve SV and fan motor indoor FMI are mainly controlled by the value of ( RAT SPT ).In the graph above, the FMI is operating in AUTO speed mode. Therefore, the FMI speed changes automatically according to the ( RAT - SPT ). NOTES 1. After the CM has stopped, the FMI runs for 30s in order to purge heat from the indoor coil. 2. The FMI will not be turned on until the indoor coil temperature is warm enough to prevent the supply of cool air (see COLD DRAFT PREVENTION feature for details). The indoor fan can change speed only after it has operated at the same speed for 30 sec if in AUTO and 1 sec for the other settings (High, Med, Low). 14

3 Auto (Cool/Heat) Mode Operation In Auto Mode, the unit switches automatically between the Auto Cooling and Auto Heating in order to maintain the room temperature (RAT) at the prescribed set point (SPT). The switching between the two modes is according to the above graph. Refer to the sections 1.COOLING MODE and 2.HEATING MODE for system operation details. 15

4 Dry Mode Operation Reducing the ambient temperature. This is done cycling ON and OFF indoor and outdoor units according to below. ROOM TEMP DRY LEVEL SPT+2 C LEVEL 0 Operation according to COOLING mode CM on < SPT+2 C LEVEL 1 FMO on SPT-1 C FMI switches between L and off (30 seconds) RV off CM switches 9 minutes off and 3 minutes on < SPT-1 C LEVEL 2 FMO switches 9 minutes off and 3 minutes ON 15 C FMI switches off and L during CM operation RV off CM off < 15 C DRY OFF ZONE FMO off FMI off RV off SPT = Set Point Temperature 5) Fan Mode Operation With this mode, the indoor fan is turned on while CM, FMO and RV stay off all the time. The user can select between 3 speeds: HIGH, MEDIUM and LOW. 6) Auto Fan speed With this option selected, the indoor fan speed changes automatically according to the difference between the detected air temperature (RAT sensor) and the set point (SPT): COOLING MODE 2 (RAT SPT): HIGH speed 1 (RAT SPT) < 2: MEDIUM speed (RAT SPT) < 1: LOW speed HEATING MODE 2 (SPT - RAT): HIGH speed (SPT - RAT) < 2: MEDIUM speed NOTE SPT = Set Point Temperature 16

7) Forcede mode means of the OPERATION button on the front panel. The operation modes can be selected pressing the button in a cyclic way (OFF COOL HEAT OFF ). The settings are: COOLING mode SET POINT temperature = 25 C FAN SPEED = HIGH HEATING mode SET POINT temperature = 21 C FAN SPEED = HIGH See also paragraph 15 for additional details. 8) Protection operations in Cool and Dry Mode 8.1 Freeze-up This protection prevents ice formation on the indoor coil heat exchanger. The protection is activated by the indoor coil temperature (ICT sensor) and only after 6 minutes of compressor operation. This protection acts in 2 levels: LEVEL 1 INDOOR FAN SPEED: ANY (as selected from remote controller) COMPRESSOR: ON OUTDOOR FAN: cycling (30 seconds ON 30 seconds OFF). DRAIN PUMP: operates according to paragraph 17 LEVEL 2 INDOOR FAN SPEED: ANY (as selected from remote controller) COMPRESSOR: OFF for at least 6 minutes and until ICT 8 C OUTDOOR FAN: OFF for at least 6 minutes and until ICT 8 C DRAIN PUMP: always ON ( stops when exiting the protection) The system exit this protection routine when ICT temperature rises above 8 C. 17

9) Protection operations in Heat Mode 9.1 Cold draft This feature prevents the supply of cold air forcing the indoor fan to a speed which cannot be changed by the user. As soon as the protection mode is exited speed can be changed manually through the remote controller. The protection acts in the following 18

9.2 Overheat This feature prevents the build up of high pressure in the indoor heat exchanger during heating 19

10) I Feel Function sensor equipped in the wireless remote controller (icon I FEEL shown on the display). This feature provides a personalised environment since the temperature can be detected where the remote controller is located. It is possible to de-activate this option pressing the I FEEL button on the remote controller. In this case the I FEEL icon is no longer displayed and room temperature is detected trough the sensor included in the indoor unit. 11) Night Function When this function is active, room temperature changes automatically to compensate for body temperature variations while sleeping. After 10 hours of operation system switches automatically to OFF state. This mode of operation is available both in COOLING and HEATING mode. 20

10) 12) Diagnostic With this feature is possible to have a visual signal that a trouble is occurring. In case of no troubles the LEDS status follows its normal function. NOTES The troubles are showed according a priority list that is in case of more than one trouble present, is always showed, at first, the one with the highest priority (1 2 3 etc). Sensor damaged means a situation where sensor is short-circuited or opened. In case of damaged sensors, the system (CM, FMO, FMI etc), if in OFF state, does not start. WRONG MODE SELECTED means a situation where the operating mode chosen with remote controller does not comply with the one allowed by jumpers settings. Priority TROUBLE LEDS status LD1(stby) LD2(opr) LD3(timer) 1 RAT damaged F O O 2 ICT damaged F F O 3 WRONG MODE F F F SELECTED Effects System does not operate O = LED off F = LED blinking 21

13) Jumpers configuration Unit is shipped with jumpers set according to the following table: JUMPER STATUS JP1 open JP2 open for H/P models - closed for other versions JP3 open JP4 closed JP5 closed 22

14) CONTACTS FOR BUILDING AUTOMATION INPUT CONTACT (J4 - green) - AVAILABLE ONLY IF "BOILER CONNECTION KIT" IS NOT INSTALLED The status of this input affects system operation according to the following: Contact OPEN : system does not operate (always OFF) inputs from wireless remote controller are not processed Contact CLOSED: system operates in the normal way according to the inputs coming from wireless remote controller OUTPUT CONTACT (J12) This connector is directly tied to the contact (normally open) of a power relay which activates every time the following alarm condition occur: RAT damaged ICT damaged In this case when alarm happens, on poles 1 and 3 of J12 connector, 220 VAC-50Hz are available. Max electrical load: 1A- 240VAC 23

15) Maintenance address to each unit in order to avoid operation conflicts. Address is set acting on the dip-switches located on the indoor PCB and on the remote controller. The PCB settings must match the corresponding ones on the wireless remote controller How to change address of the air conditioner Dip switch is located on the indoor PCB near the buzzer. Set the PCB to the address desidered UNIT SETTINGS ADDRESS SW1 SW2 1 off off 2 off on 3 on off 4 on on As default switches SW1 and SW2 are in off status (PCB factory state). How to change address on Remote Control Unit Dip switch is located on the battery compartment. 1) Pull out the door and remove the batteries. 2) Set the switch SW1 and SW2 according to the indoor PCB settings (do not act on SW3 and SW4) 3) Insert the batteries and pull on the door As default switches SW1 and SW2 are in off status (remote controller factory state). 24

16) Manual Unit Control and Led indicators The push button switch and the LED indicators on display panel let the user to control the unit operation without a R/C (Remote Controller). Their operations are provided below. Push Button Switch : Use to cycle the operation mode of the A/C unit among COOL, HEAT and OFF modes, without using the R/C. OPERATION BUTTON Every time this switch is pressed, the next operation mode is selected, in order: - Off => Cool mode => Heat mode => Off => (for heat pump model) - Off => Cool mode => Off => (for cooling only model) - The A/C will start in High fan speed. The temperature setting is 25 C for cooling and 21 C for heating mode. WARNING: the OFF position does not disconnect the power. Use the main power switch to turn off power completely. Led indicators : TIMER LAMP STANDBY LAMP OPERATION LAMP 1. Lights up during Timer operation. 1. Lights up when the Air conditioner is connected to power and ready to receive the Remote Control command. 2. Blinks continuously in case of any thermistor failure. 1. Lights up in Operation mode ( Note: OFF in standby mode). 2. Blinks for 0,5 sec., to announce that a R/C infrared signal has been received and stored. 3. Blinks continuously in case of any thermistor failure. 4. Blinks continuously in case of FS (Float Switch) trips for high water level. TIMER+STBY+OPR LAMP 1. Blinks continuously in case of wrong mode selected. Recovery from Power Failure 25

17 Ws Imput Switch The WS switch status (open/closed) rules system operation in two different way. 16.1 WATER FLOW-RATE MODE This mode is available when the WS_FLG parameter is set to 2 (water flow rate type). Drain pump is not present. WS status affects system operation only when unit is ON and according to the following chart: 26

M ELECTRIC WIRING DIAGRAMS 1- Cooling only model ARGO 245SCH2O LEGENDA PCB Controller board SW-IND-ASSY Indicator assy FMI Indoor fan motor TH1-2-4 Thermistor RL1 Power relay TP Terminal plate CM Compressor motor HWC Hot water control OLR Overload relay TM Water min temperature thermostat SV Solenoid valve EWV Electrically operated water valve C1-2 Capacitor FLP Flap motor HT High pressure switch F1 Fuse F Flow switch 27

2- Heat pump model ARGO 235HPH2O LEGENDA PCB Controller SW-IND-ASSY Indicator assy FMI Indoor fan motor TH1-2-4 Thermistor RL1 Power relay TP Terminal plate CM Compressor motor HWC Hot water control OLR Overload relay TM Water min temperature thermostat SV Solenoid valve EWV Electrically operated water valve C1-2 Capacitor FLP Flap motor HT High pressure switch F1 Fuse F Flow switch 20S 4-way valve 28

N 29

C 30

D 2) 31

E 32

Unit still does not run Unit still does not run 33

F Only if IFEEL is selected Temperature difference between suction and discharge air is large enough (approx. 15 C or more) install an additional unit G Only if IFEEL is selected 34

H RT RT 35

O REFRIGERANT CHARGE REFRIGERANT CHARGE R410A ARGO 245SCH2O 360 g ARGO 235HPH2O 470 g IMPORTANT When recharging the unit please use the high-pressure service pipe. Preliminary operation after refrigerant charge To distribute the oil to all the moving/sliding portions, run the compressor for at least 3 seconds within 15 minutes after refrigerant charge 36

P 37

38

Q BOILER CONNECTION KIT Hot water coil Typical installation Existing water connections By installer 1/2" Gas Female diameter Electric water valve Controller By installer Boiler connection Kit Air conditioner unit 1) SPECIFICATIONS Power source 230 V ~ 50 Hz Capacity at standard conditions Power input W W 2100 27 Fan speed Standard conditions: Ambient temp. C 3 ( Hi - Me - Lo ) 20 Fan speed High Inlet water temp. C 70 T water K 10 Water coil only P water kpa 0,7 ( 70 mmh2o) water flow l/h 155 ( 2,6 l/min.) Valve and tubes P water kpa 2,9 ( 290 mmh2o) including water flow l/h 190 ( 3,1 l/min.) OPERATING LIMITS Max temperature inlet hot water C Max pressure bar 39 70 C 10

2) PERFORMANCE CHARTS Performance on different conditions Capacity ruduction factor : High speed = 1 ; Med. speed = 0,96 ; Low speed = 0,93 Capacity 140% 120% 70 C inlet water temp. 10 9 8 Pressure drop kpa 100% 7 60 C 6 80% 5 60% 50 C 4 40% 20% 3 2 1 0% 4 6 8 10 12 14 16 t = (inlet water temp.) - (outlet water temp.) 0 Pressure drop kpa WATER FLOW AND PRESSURE DROP ( 3 WAY VALVE AND PIPE INCLUDING ) 8 7 6 5 4 3 2 1 0 0.8180.519.1 11 / 2007 50 100 150 200 40 250 300 Water flow 350 l/h

3) COMPONENT SPECIFICATIONS ( Boiler connection kit ) CONTROLLER ( HWC ) Type Controls Thermostat THERMISTOR ( ROOM SENSOR ) TH4 Type Resistance (at 25 C) as alternative CONTROLLER ( HWC ) Type Controls Thermostat THERMISTOR ( ROOM SENSOR ) TH4 Type Resistance (at 25 C) LIMIT WATER THERMOSTAT ( TM ) Electrical rating Control setting Differential WATER ELECTRIC VALVE ( EWV ) Electric Thermal Actuator Supply voltage Power consumpion: Nominal force Nominal stroke Full stroke time at 50 C 3-way Forged brass valve Body Type Threaded Male Connection Close-Off Pressure Water HEAT EXCHANGER COIL Coil Rows Fin pitch Setting Differential kω Setting Differential Type kω Continous Start-up Actuator stem Actuator stem Type Type kpa mm Face area m 2 Threaded Male Connection 000TSA Manual 6 C ±1 C 30 C ±1 C 1K STLNGY050 4,7 ±2% 078564-00 Manual 6 C ±1 C 30 C ±1 C 1K 77798 6,8 ±2% 10(1,6) A - 250Vac Autoreset Open : 31 C ±3 C - Close: 42 C±4 C 11K VA-7040-23 230VAC ± 15% 2,5 W 36 W (150 ma) max 125 N 4,5 mm extends : 60 sec retract : 10 min VG-5510EC 3-way NO bypass 1/2" Gas 100 Aluminium plate fin / Copper tube 1 2,0 0,102 1/2" Gas 41

4) HYDRAULIC CONNECTIONS AND VALVE 43

Via Varese, 90-21013 Gallarate - Va - Italy Tel. +39 0331 755111 - Fax +39 0331 776240 www.argoclima.it