Copeland Scroll Outdoor Refrigeration Unit

Similar documents
These units are available now from the Distribution Center. For a list of available models, click here.

Copeland Scroll. Product Information. Outdoor condensing units for refrigeration applications

The Copeland Scroll Outdoor Condensing Unit (X-Line Series) for commercial refrigeration applications offers c-store operators the greatest energy

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Copeland Scroll Condensing Units for the Food Service Market

500 EX Fusion Compressor Series

The Copeland Scroll Outdoor Condensing Unit (X-Line Series) for commercial refrigeration applications offers c-store operators the greatest energy

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

Air-Cooled Condensing Units with Compact Screw Compressors

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Application Engineering

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

INDEXING AND CLASSIFICATION SYSTEM

Copeland Scroll ( HP) ZB*KA and ZF*KA for Refrigeration

TECHNICAL SPECIFICATIONS

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

NO: 9-16 DATE: 2/11/16 EMERSON CLIMATE TECHNOLOGIES WHOLESALERS -EXECUTIVES -PRODUCT MANAGERS -EMERSON TM TECHNICAL SPECIALISTS -BRANCH PERSONNEL

BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

horizontal air discharge outdoor discus condensing unit

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

NQ Series Portable Chillers

Air-Cooled Condensing Units with Bitzer Compressors

roof finish is 26 gauge acrylic coated stucco galvanized steel.080 textured aluminum interior floor finish, where required

30GN FLOTRONIC II AIR-COOLED CHILLERS

Condensing Units w/ Screw Compressors

3-22 HP CONDENSING UNITS Technical Guide

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

A Complete Line Of Remote Rack Refrigeration Systems

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

CONDENSERS AND CONDENSING UNITS

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control

September 2016 AE Application Guidelines for Copeland CS**KIE Compressors in Ice Machines AE4-1421

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

Refrigeration System Report March 2017

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT

10-Bilt. Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Precise Temperature Control; Compact Footprint

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

Modular Air Cooled Scroll Chillers

30GT FLOTRONIC AIR-COOLED CHILLERS

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

commercial refrigeration products

DROP-IN + PLUG-IN UNITS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Installation, Operation, and Maintenance Information

Application Guidelines for Glacier K3 Copeland Scroll Refrigeration Compressors

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Condensing Units CUS 15-60

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Variable Refrigerant Flow

COOLTEC. C O O LT E C R E F R I G E R A T I O N C O R P O R A T I O N 1250 east Franklin Avenue Pomona Ca l i f o r n i a p h o n e

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

2 shp 13 lc 1 36 t - 1 a

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

MEDICAL CHILLER SYSTEMS

Optimize your HVAC/R application with the right Danfoss components

Emerson Superheat Control. The smart solution for your application

MODELS LIST. Nominal Capacity RT

ThermoSaver TM Hot Gas Defrost System

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

Kramersaver Air Cooled Condensing Units

Kirby Commander Condensing Unit

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

SMALL AIR COOLED CONDENSERS

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

PACKAGED AIR COOLED Product Data Catalog

RSG16**S1M. Split System Air Conditioner 16 SEER

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID

Liebert CSU3000 Chiller

Natural Refrigeration with Hydrocarbons Emerson s R290 Solutions

Heat Pumps COMFORT NEED IT. When You

TECHNICAL SPECIFICATIONS

LQ AQ SQ. Air-cooled and water-cooled portable chillers

MACH N-407 Heat Pump Air-Cooled Chiller

SCA 620C AIR COOLED SCREW CHILLER

LG VRF Systems. Air Conditioning Technologies

High Profile Evaporator

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

AND WORRY-FREE PERFORMANCE

Distributed Systems Sales Brochure

ThermoSaver TM Hot Gas Defrost System

Transcription:

Copeland Scroll Outdoor Refrigeration Unit Medium and low temperature applications Convenience Store Restaurant R-22, 134a, 404A/507A, 407C/A, 448A/449A 1.5-6 HP

Innovative design based on three factors demanded by industry users 1 Energy Efficiency The Copeland Scroll Outdoor Refrigeration Unit significantly reduces energy consumption by utilizing scroll compressor technology, variable speed fan motors, large capacity condenser coils and advanced control algorithms. Compared to hermetic reciprocating units, end-users will save more than $350 in annual energy costs. 2 Reliability Combining the proven reliability of Copeland Scroll compressors with advanced CoreSense Diagnostics, equipment reliability is greatly enhanced. Fault code alerts and fault code retrieval capabilities provide information to help improve speed and accuracy of system diagnostics. Integrated electronics provide protection against over-current, over-heating, incorrect phase rotation, compressor cycling, high pressure resets, low pressure cut-outs and liquid flood-back conditions that cause unexpected performance losses or worse, unplanned equipment failure. As part of the Emerson family of products, the Copeland Scroll Outdoor Refrigeration Unit provides unsurpassed access to system status, diagnostics, and operational control. 3 Flexibility The light weight and slim-line profile ease the installation process. The ultra quiet variable-speed fan motor significantly reduces exterior sound levels, allowing use in noise restricted residential zones. With high and low ambient operation capability, coated coils for coastal applications, multi-refrigerant capabilities, and optional wall mounting capability, the units deliver unmatched mounting and environmental location flexibility. Perfectly suited for walk-in and display case cooler and freezer applications. All units integrate the many benefits of scroll compressor technology, fan speed control, and CoreSense Diagnostics, delivering higher energy efficiency and lower sound levels, while ensuring reliable performance and operation in foodservice applications. Two sound values shown represent the X-Line unit s lowest and highest operating dba measurements, or typical industry outdoor unit published data, for both MT and LT products. Sound pressure values are 10 feet from the unit at 25 F evap for MT and -10 F evap for LT at 90 F ambient. A sound reduction of up to 3 dba will occur in ambient temperatures below 70 F This data is typical of free field conditions for horizontal air cooled condensing units and may vary depending on the condensing unit installation. There are many factors that affect the sound reading of a condensing unit such as unit mounting, reflecting walls, background noise and operating condition.

Standard Features Electronic control module consolidating all unit operations, defrost, diagnostics, compressor protection, and communications External service valves and hinged service panel for easy setup and service Standard moisture indicator and liquid filter drier Quiet variable speed condenser fan Heated and insulated receiver with pressure relief valve Powder-coated galv-annealed chassis and coated condenser fins for corrosion protection Standard accumulator and oil separator on low temp models. Optional accumulator on medium temp models. Accessories Part Number Description Purpose 074-7286-00 Wall bracket Allows mounting unit to walls 074-7289-00 Adjustable stand Raises unit 12 inches from ground level 943-0224-00 PC interface kit Allows direct connection of unit to PC 943-0058-00 Remote display Control/view unit status up to 30 feet from unit Nomenclature Nomenclature X F A M 0 2 0 Z T F C 0 8 1 Family = X-Line F = Multi-refrigerant A = Air-Cooled L = Low Temp M = Medium Temp P = Multiple Applications 1.5 to 6.0 = H.P. Z = Scroll CFV = 208/230V-1ph- 60Hz TFC = 208/230V-3ph- 60Hz To place an order select Base Model > Electrical > Bill of Material 0 = UL Listed Product 81 = Standard Feature Energy improvement (More than $350 per year) Sound improvement Diagnostic protection capabilities Slim profile, lighter weight, and optional wall mount capability Multi-refrigerant* Owner/Enterprise Benefit Lower operating costs Creating a more comfortable environment for guests Beneficial for regions with noise ordinances Reduce nuisance calls Extends life of your equipment Faster, more accurate service, and reduced call-backs Maintains your equipment to original standards, maintaining energy efficiency and temperature control Have confidence in what your contractor is fixing Lower installation costs Improved appearance of your enterprise site Avoids more costly solutions for potential location issues R-22, R-134a, R-404A, R-407C/A, R-448/449A Scalable electronics can operate as a stand-alone unit Emerson family of electronics or connect as part of a full intelligent store * Visit EmersonClimate.com/OPI for specific refrigerant approvals for each model.

Specifications Unit Model Refrigerant Compressor Chassis Receiver Capacity (Lbs @ 90% Volume) Length Width Height Connections Max MCA Electrical Size Fuse Liquid Suction R-22 R-134a R-404A R-407A R-407C XFAM-015Z-CFV ZS09KAE-PFV 13.55 20 XFAM-015Z-TFC ZS09KAE-TF5 11.05 15 XFAM-017Z-CFV ZS11KAE-PFV 16.80 25 XFAM-017Z-TFC ZS11KAE-TF5 14.05 20 1 FAN 33.1 10.3 10.4 8.9 9.8 9.8 XFAM-022Z-CFV ZS15KAE-PFV 20.68 35 XFAM-022Z-TFC ZS15KAE-TF5 14.30 20 XFAM-030Z-CFV ZS21KAE-PFV 30.05 50 XFAM-030Z-TFC ZS21KAE-TF5 20.05 30 XFAM-045Z-CFV ZS33KAE-PFV 37.35 60 XFAM-045Z-TFC ZS33KAE-TF5 29.98 50 XFAM-050Z-CFV ZS38K4E-PFV 2 FAN 48.9 15.1 15.3 13.1 14.4 14.3 41.85 70 16.7 40.5 1/2 S 7/8 S XFAM-050Z-TFC ZS38K4E-TF5 28.85 45 XFAM-060Z-TFC ZS45K4E-TF5 31.975 50 XFAL-020Z-CFV ZXI06KCE-PFV 21.55 35 XFAL-020Z-TFC ZXI06KCE-TF5 16.175 25 1 FAN 33.1 8.9 9.8 9.8 XFAL-030Z-TFC ZXI09KCE-TF5 17.175 25 XFAL-035Z-CFV ZXI11KCE-PFV 34.05 50 XFAL-040Z-CFV ZXI14KCE-PFV N/A N/A 40.1 60 XFAL-040Z-TFC ZXI14KCE-TF5 27.1 45 XFAL-050Z-TFC ZXI15KCE-TF5 2 FAN 48.9 13.1 14.4 14.3 28.85 45 XFAL-051Z-CFV ZXI16KCE-PFV 44.725 70 XFAL-060Z-TFC ZXI18KCE-TF5 33.975 50 Dimensional Drawings Single Fan Unit 1.5-3 HP Bottom View All Models Dual Fan Unit 4-6 HP

R-404A MT Model Comp 0 5 10 15 20 25 30 35 40 45 90 Ambient XFAM-015Z ZS09KAE 7,400 8,260 9,200 10,200 11,300 12,500 14,100 15,400 16,900 18,400 XFAM-017Z ZS11KAE 8,880 9,900 11,000 12,200 13,500 14,900 16,800 18,400 20,000 21,800 XFAM-022Z ZS15KAE 12,000 13,400 14,800 16,400 18,100 20,000 22,300 24,300 26,400 28,600 XFAM-030Z ZS21KAE 17,600 19,600 21,600 23,900 26,200 28,800 31,800 34,500 37,200 40,100 XFAM-045Z ZS33KAE 24,400 27,100 30,000 33,100 36,400 40,000 44,500 48,200 52,000 56,000 XFAM-050Z ZS38K4E 29,100 32,000 35,200 38,500 42,100 45,800 51,500 56,000 60,500 65,000 XFAM-060Z ZS45K4E 34,500 37,900 41,500 45,400 49,500 54,000 60,500 65,500 70,500 76,000 100 Ambient XFAM-015Z ZS09KAE 6,850 7,630 8,490 9,420 10,400 11,500 12,900 14,100 15,400 16,800 XFAM-017Z ZS11KAE 8,220 9,140 10,200 11,300 12,500 13,700 15,400 16,800 18,300 19,900 XFAM-022Z ZS15KAE 11,100 12,300 13,700 15,100 16,700 18,400 20,500 22,300 24,100 26,100 XFAM-030Z ZS21KAE 16,300 18,000 19,900 21,900 24,000 26,400 29,300 31,600 34,100 36,700 XFAM-045Z ZS33KAE 22,500 25,000 27,600 30,400 33,400 36,700 41,000 44,300 47,800 51,500 XFAM-050Z ZS38K4E 26,600 29,300 32,200 35,200 38,400 41,800 47,400 51,500 55,500 60,000 XFAM-060Z ZS45K4E 31,700 34,700 38,000 41,500 45,200 49,100 55,500 60,500 65,000 70,000 110 Ambient XFAM-015Z ZS09KAE 6,260 6,960 7,730 8,570 9,480 10,500 11,800 12,900 14,000 15,200 XFAM-017Z ZS11KAE 7,500 8,330 9,240 10,200 11,300 12,500 14,100 15,400 16,700 18,100 XFAM-022Z ZS15KAE 10,100 11,200 12,400 13,700 15,100 16,700 18,800 20,400 22,100 23,800 XFAM-030Z ZS21KAE 14,800 16,300 18,000 19,800 21,700 23,800 27,100 29,200 31,400 33,700 XFAM-045Z ZS33KAE 20,500 22,600 25,000 27,500 30,200 33,200 38,000 41,000 44,100 47,400 XFAM-050Z ZS38K4E 24,100 26,500 29,000 31,700 34,600 37,700 43,200 46,900 50,500 55,000 XFAM-060Z ZS45K4E 28,700 31,500 34,400 37,500 40,800 44,400 51,000 55,000 59,500 64,000 Capacities rated at 40 F return gas (65 return gas for capacities in bold), 5 F subcooling R-404A LT Model Comp -40-35 -30-25 -20-15 -10-5 0 90 Ambient XFAL-020Z ZXI06KCE 5,700 6,960 8,210 9,450 10,690 11,920 13,140 14,360 15,570 XFAL-030Z ZXI09KCE-TF5 7,840 9,390 10,950 12,500 14,060 15,620 17,170 18,730 20,280 XFAL-035Z ZXI11KCE-PFV 9,700 11,100 12,600 14,200 15,900 17,700 19,700 21,700 23,900 XFAL-040Z ZXI14KCE 12,690 14,430 16,280 18,240 20,300 22,470 24,740 27,120 29,610 XFAL-050Z ZXI15KCE-TF5 14,030 16,040 18,140 20,350 22,660 25,060 27,570 30,170 32,880 XFAL-051Z ZXI16KCE-PFV 14,030 16,040 18,140 20,350 22,660 25,060 27,570 30,170 32,880 XFAL-060Z ZXI18KCE 18,000 20,500 23,000 25,700 28,600 31,600 34,700 38,100 41,500 100 Ambient XFAL-020Z ZXI06KCE 5,640 6,840 8,020 9,200 10,370 11,530 12,680 13,830 14,970 XFAL-030Z ZXI09KCE-TF5 6,940 8,520 10,100 11,680 13,260 14,840 16,420 18,000 19,580 XFAL-035Z ZXI11KCE-PFV 9,090 10,300 11,700 13,100 14,700 16,300 18,100 20,000 21,900 XFAL-040Z ZXI14KCE 12,370 13,980 15,710 17,540 19,480 21,530 23,680 25,940 28,300 XFAL-050Z ZXI15KCE-TF5 13,110 14,960 16,900 18,940 21,080 23,320 25,660 28,100 30,640 XFAL-051Z ZXI16KCE-PFV 13,110 14,960 16,900 18,940 21,080 23,320 25,660 28,100 30,640 XFAL-060Z ZXI18KCE 17,240 19,480 21,930 24,380 27,030 29,780 32,740 35,800 38,200 110 Ambient XFAL-020Z ZXI06KCE 5,500 6,610 7,710 8,810 9,890 10,970 12,040 13,100 14,160 XFAL-030Z ZXI09KCE-TF5 5,830 7,420 9,010 10,590 12,180 13,770 15,350 16,940 18,530 XFAL-035Z ZXI11KCE-PFV 9,020 10,140 11,340 12,720 14,200 15,690 17,380 19,190 21,090 XFAL-040Z ZXI14KCE 11,850 13,350 14,950 16,660 18,480 20,400 22,420 24,560 26,800 XFAL-050Z ZXI15KCE-TF5 11,920 13,590 15,370 17,250 19,220 21,300 23,470 25,740 28,110 XFAL-051Z ZXI16KCE-PFV 11,920 13,590 15,370 17,250 19,220 21,300 23,470 25,740 28,110 XFAL-060Z ZXI18KCE 16,170 18,330 20,500 22,760 25,130 27,600 30,200 32,960 34,700 Capacities rated at 65 F return gas, 5 F subcooling

Application Engineering Bulletins available at Emerson.com/OPI 4-1273 Factors to Consider in Converting Compressor Rated Capacity to Actual Capacity 4-1327 Economized Vapor Injection (EVI) Compressors 11-1147 Suction Accumulators 11-1297 Liquid Line Filter Driers 17-1260 Compressor Overheating 17-1268 Compressor Ratio as it Affects Compressor Reliability 22-1182 Liquid Refrigerant Control in Refrigeration and Air Conditioning Systems 5-1412 Copeland Scroll Outdoor Refrigeration Unit X-Line User Manual This bulletin is provided with each unit and is a source for additional product details. For more information visit: Emerson.com/CopelandOutdoorUnit 2009IP-50 R6 (11/16) Emerson, Copeland Scroll and CoreSense are trademarks of Emerson Electric Co. or one of its affiliated companies. 2016 Emerson Climate Technoligies, Inc. All rights reserved.