User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput

Similar documents
IM 77J01H07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0

IM 77J01A07-01E 1st Edition Nov th Edition Feb Fixed code 0 Always 0. Output-2 signal

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

User s. Manual) Model VJUK Limit Alarm for Universal Input

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

General Specifications

DIGITAL INDICATOR JIR-301-M

Series Temperature Controller Instruction Sheet

Instruction manual Temperature Controller KT7

General Specifications

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

Series Digital Controller Instruction Sheet

RS485 MODBUS Module 8AI

ISOLATOR SGI SGIW INSTRUCTION MANUAL

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Instruction manual for DIN rail mounting type indicating controller DCL-33A

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Temperature Controllers

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Advanced Ultraviolet Burner Controller

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

Carbon Monoxide Transmitter

02/11/2015

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

DIN RAIL MOUNTED INDICATING CONTOLLER DCL-33A INSTRUCTION MANUAL

02/11/2015

CLEANROOM MONITOR CR3A Network - Installation Instructions

DIGITAL INDICATOR DI25

Analog Room Pressure Monitor RPC Series

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER JCD-13A, JCR-13A

I/A Series 716C 1/16 DIN Temperature Controller

1. Model ACS 1 3 A / A, Series name: ACS-13A- /A (W48 x H48 x D62mm) Control action 3 PID A1 A Alarm type can be selected by keypad.

SHIMADEN DIGITAL INDICATORS

INSTRUCTION MANUAL Micro-computer based digital indicating controller

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

GCS-300 No.GCS31E

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER GCD-200, GCR-200

Infrared Moisture Determination Balance FD-610. Operating Manual

Multi-Gas-Controller MGC2

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Instruction manual Micro-computer based digital indicating controller

CU-02 with Senaco Plus

Installation Manual Tracker 221

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

UDC 700 Universal Digital Controllers and Indicator Specifications

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Operating Manual TR600

47LV BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL DC INPUT DIGITAL PANEL METER MODEL. (4 1/2 digit, LED display type)

S304 and S305 Dust Emission Monitors. User Manual. Distributor

ESSEX ENGINEERING CORPORATION

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

PLC INTERFACE UNIT CIT-200 INSTRUCTION MANUAL

Digital Panel Meters 47 Series. DC INPUT DIGITAL PANEL METER (4 1/2 digit, LED display type) Model: 47LV OPERATING MANUAL

Digital Heater Element Burnout Detector K8AC-H

Class 1 laser beam sensor safe for your eyes

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Buzzer Unit. TAN-5000 Series. Operating Manual

User Guide. DATUM L150 Panel-Mounted Universal Level Indicator A1. ABB Instrumentation

Indoor Oxygen Monitor OX-600 Operating Manual

ME 3011C / Alarm Indication / Quick Reference Guide

AE500 Instruction Manual

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

CTT8 TEMPERATURE MONITOR DEVICE

Software Version 2.01 LEVEL MONITOR MODEL 220

WIO200 Water In Oil measuring instrument

2-wire Passive Intelligent Loop (LED) Display Meter

Pump-Up Controller MODEL 4062

Model D12-IR. Digital Gas Transmitter...

2-wire Passive Intelligent Loop (LED) Display Meter

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

Process Alarm Module RTA 421

RSMFM-2R MULTIFUNCTIONAL

Instruction Manual August sitrans CU 02

MICROJET RECORDER (180mm)

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Ionizer (Static Remover) STABLO-EX Instruction Manual

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Class 1 laser beam sensor safe for your eyes

Pump-Down Controller MODEL 4052

User Guide IM/L160_6. Wall-/Pipe-mount Level Indicator L160

Universal controller for panel mounting Models CS6S, CS6H, CS6L

F4 Process Controller Installation and Operation Guide

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

OPTISENS TUR 2000 Technical Datasheet

Nov 08 PRODUCT SPECIFICATION SHEET

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

DMFPM-2R MULTIFUNCTIONAL

Transcription:

User s Manual Model VJS Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput Types) --, Naka-cho Musashino-shi, Tokyo 80-80 Japan You can download the latest manuals from the following website: http://www.yokogawa.com/ns/juxta/im/ Thank you for purchasing the JUXTA Signal Conditioner. Please read through this manual before use for correct handling. IM J0S0-0E th Edition Feb. 0 ARY NOTES FOR SAFE USE OF THE PRODUCT This User s Manual should be carefully read before installing and operating the product. Please keep this User s Manual for future reference. For more information of the safety precautions, please refer to the Precautions on the Use of the JUXTA Series (IM J0A00-Z). The related manuals and general specifications are shown in the table below. Doc. Name Doc. Number Precautions on the Use of the JUXTA Series (User s Manual) IM J0A00-Z Model VJS Potentiometer Converter (User s IM J0S0-0E Manual) (This manual) Model VJS Potentiometer Converter (General GS J0S0-0E Specifications) User s manuals in the above table are essential parts of the product; keep it in a safe place for future reference. This manual is intended for the following personnel; Engineers responsible for installation, wiring, and maintenance of the equipment. Personnel responsible for normal daily operation of the equipment. The following symbol is used on the product and in this manual to ensure safe usage. WARNING Calls attention to actions or conditions that could cause serious or fatal injury to the user, and indicates precautions that should be taken to prevent such occurrences. Calls attention to actions or conditions that could cause injury to the user or damage to the instrument or property and indicates precautions that should be taken to prevent such occurrences. CHECKING THE PRODUCT SPECIFICATIONS AND THE CONTENTS OF PACKING () Checking the Model and Product Specifications Check that the model and specifications indicated on the nameplate attached to the main unit are as ordered. () Contents of the Packing Check that the package contains the following items: VJS: unit Standard Accessories: Tag number label: sheet Range label: sheet User s manual (IM J0S0-0E, this manual): copy User s manual (IM J0A00-Z): copy GENERAL This plug-in type converter is used in combination with transmitters which send displacement information of regulator valves by resistance change signals from a potentiometer, and converts the resistance change into isolated DC current or DC voltage signals. Output- can be selected from DC voltage signal, DC current signal, communication function (RS-8), or alarm output ( relay contacts). (Isolated Dual-output Type) Various parameters such as input range can be set and modified using a PC (VJ(sold separately)) or Handy Terminal (JHT00(sold separately) and the like). MODEL AND SUFFIX CODES Model Suffix codes Description VJS -0 x x - x x 0 /x Potentiometer Converter (Multifunction) Fixed code -0 Always -0 Output configuration output outputs Power supply 00-0 V AC/DC (*) -0V DC (*) Input signal - Potentiometer resistance (Total resistance: 00Ω to 0kΩ) -Z Optional signals of resistance other than the code- resistance above Output- A to 0mA DC B to 0mA DC C to ma DC D 0 to 0mA DC E 0 to ma DC F 0 to 0mA DC G 0 to ma DC 0 to 0mV DC 0 to 00mV DC 0 to V DC 0 to 0V DC 0 to V DC to V DC 0 to 0V DC Z (Custom Order) (*) Output- A to 0mA DC to V DC P Communication function (RS-8) T Alarm output ( relay contacts) N No output- Fixed code 0 Always 0 Option /SN No socket (with socket if not specified) /C0 HumiSeal coating (*) /FB Fuse bypass (*) * Operating range: 8- V AC/DC * Operating range: - V DC * DC voltage signal or DC current signal * When option code /C0 or /FB is specified, the conformity to the safety and EMC standards is excluded. CE marking is not applicable.

. MOUNTING METHODS Plug/disconnect the main unit into/from the socket vertically to the socket face. Otherwise the terminals may bend and it may cause bad contact. The converter shall not tilt degrees or more in either direction when installed. When the converter is not connected to the socket, it is necessary to protect the socket against ingress of dust to the connector part. Keep this product in a conductive bag when plugged out, during transport or storage.. Wall Mounting Loosen the main unit-fixing screw of the product and pull out the main unit from the socket. Fix the socket on the wall with screws. Next, insert the main unit into the socket and fasten the main unit with the main unit-fixing screw. Main unit Mounting screws Main unit-fixing screw Threaded hole for fixing the main unit Socket (Part no.: T0FL) Mounting Dimensions ±0. Unit: mm. or more -M or ±0. -ø. or more. DIN Rail Mounting Insert a into the upper part of the groove on the rear of the socket, and then slide the slide lock at the lower part of the socket upwards until the socket is fixed into position as shown below Push Fit into here Socket (Part no.: T0FL) (Rear of socket) Slide look. Mounting Using When using a multi-mounting base, see the User's Manual for VJCE (VJCE Mounting Base).. Using a Duct When using a wiring duct, install the duct at least 0 mm away from the top and bottom faces of the main unit.. INSTALLATION LOCATION Avoid the following environments for installation locations: Areas with vibrations, corrosive gases, dust, water, oil, solvents, direct sunlight, radiation, a strong electric field, and/or a strong magnetic field, direct radiant heat, wind, temperature fluctuation,,000 m or more above sea level. If there is any risk of a surge being induced into the power line and/or signal lines due to lightning or other factors, a dedicated lightning arrester should be used as protection for both the product and a field-installed device. Operating temperature/humidity range: -0 to C (-0 to C for side-by-side mounting*)/ to 0%RH (no condensation) * If the previous model (style S.xx earlier) is installed together, the ambient temperature is 0 to 0 C. Continuous vibration: (at to Hz) Half amplitude of mm or less (at to 0 Hz).8m/s or less, oct/min for 0 minutes each in the three axis directions Impact: 8 m/s or less, ms, axes, directions, times each. EXTERNAL WIRING WARNING To avoid the risk of an electric shock, turn off the power supply and use a tester or similar device to ensure that no power is supplied to a cable to be connected, before carrying out wiring work. Do not operate the product in the presence of flammable or explosive gases or vapors. To do so is highly dangerous. Use of the product ignoring the specifications may cause overheating or damage. Before turning on the power, ensure the following: Power supply voltage and input signal value applied to the product should meet the required specifications. The external wiring to the terminals and wiring to ground are as specifications. Wiring should be connected to the terminals on the socket of the product. The terminals for external connections are of M screws. Use crimp-on terminal lugs for connections to the terminals. Recommended cables: A nominal cross-sectional area of 0. mm or thicker for signal cables, and that of. mm or thicker for power cables. Input 00% CENTER 0% Power Supply 0 8 L N GND 8 0 Output- signal Analog output Alarm output RS-8 Communication ALM B A Output- signal Analog output ALM Do not use output- for the isolated single-output type. The power line and input/output signal lines should be installed away from noise-generating sources. Otherwise accuracy cannot be guaranteed. Make sure to earth ground the ground terminal through minimum resistance. The length and thickness of the grounding cable should be as short and thick as possible. Directly connect the lead from the ground terminal (terminal no. 8) of the product to the ground. Do not carry out daisy-chained interground terminal wiring The product is sensitive to static electricity; exercise care in operating it. Before you operate the product, touch a nearby metal part to discharge static electricity. If an inductance (L) load such as auxiliary relays or solenoid valves is used, always insert a spark killer for diminishing sparks, such as a CR filter or a diode in parallel with the inductance load. Otherwise a malfunction or relay failure may occur. Refer to the following guidelines for a capacitor and resistor: C: 0. to µf with respect to a contact current of A R: 0. to Ω with respect to a contact voltage of V If the ambient temperature is 0 C or more, please use the cable that the rated temperature is 0 C or more. IM J0S0-0E th Edition Feb.0, 0-00

. DESCRIPTION OF FRONT PANEL. Front Panel The communications connector in the front panel is used for setting up parameters through a PC (VJ PC-based Parameters Setting Tool) or the Handy Terminal. The alarm- and alarm- LEDs light up if an alarm occurs (those LEDs are provided only when the output- is specified for alarm output (the output- suffix code is T).) Communication connector Alarm indicator lamp (for alarm ) Alarm indicator lamp (for alarm ). Connector for Communication Use the connector for communication when setting the parameters using a PC (VJ Parameters Setting Tool) or the Handy Terminal <How to connect with the setting tool> PC with the VJ installed JHT00 Handy Terminal JUXTA communication cable with -pin connector Dedicated cable Dedicated adapter Modular jack conversion adapter JUXTA VJ Series Use the VJ of version R.0.0 or later. The modular jack conversion adapter does not come with the JHT00 Handy Terminal. It is sold separately.. SETTING PARAMETERS Set the parameters using a PC (VJ Parameter Setting Tool) or the Handy Terminal. Refer to. LIST OF PARAMETERS in this manual and the User s Manual for VJ PC-based Parameters Setting Tool (IM J0J-0E) or the User s Manual for JHT00 Handy Terminal (IM J0H0-0EN). Parameters are indicated inside the [ ]. Set the parameters in order starting with (). () Burnout () Total resistance () Input range Set the burnout action before setting the input range. Changing the burnout action setting resets the input range.. Settings Related to Inputs and Outputs.. Burnout Set the burnout operation in [D: BURN OUT]. Set OFF, UP, or DOWN... Total resistance Set the total resistance in [D: RESIST]. Setting range: 00 to 0000 Ω.. Input Range Set the input low range in [P: IN LOW_RNG], and input high range in [P: IN HIGH_RNG]. () Resetting the input range Select and set RESET in [P: IN LOW_RNG] or [P: IN HIGH_RNG]. Then the input low range [D: INPUTL_RNG] or input high range [D: INPUTH_ RNG] are reset. () Setting the input low range Apply the stable signal equivalent to 0% input from the connected potentiometer. Select and set EXECUTE in [P: IN LOW_RNG]. Then the input low range [D: INPUTL_RNG] is set automatically. () Setting the input high range Apply the stable signal equivalent to 00% input from the connected potentiometer. Select and set EXECUTE in [P: IN HIGH_RNG]. Then the input high range [D: INPUTH_RNG] is set automatically... Software Filter Set the software filter in [D: S/W FILTER]. OFF, LOW, MIDDLE, HIGH (default value: OFF) When LOW, MIDDLE, or HIGH is selected, a first-order filter equivalent to 00 ms, 00 ms, or s is inserted in the input... Direction of Output Action Analog output signals can be reversed. To reverse the signal from output-, set [D0: OUT DR] to REVERSE. For output-, set [D OUT DR] to REVERSE. To return the output- signal to normal, set [D0: OUT DR] to DIRECT. For output-, set [D: OUT DR] to DIRECT.. Settings Related to Communication Function Set the following parameters when output- is specified for communication function. For more information on the communication function, see the Instruction Manual for VJ Series Communication Function (IM JJ-0E)... Communication Protocol Set the communication protocol by selecting from among PCLINK, PC-LINK WITH SUM, MODBUS ASCII, MODBUS RTU, and LADDER in [F0: PROTOCOL]... Communication Address Set the address number of the isolator numerically in a range of to in [F0: ADDRESS]... Baud Rate Set the baud rate by selecting from among 00, 00, 800, 00, 00 and 800 bps in [F0: BAUD RATE]... Parity Select and set NONE, EVEN, or ODD in [F0: PARITY]... Data Length Select and set bits or 8 bits in [F0: DATA LEN]... Stop Bit Select and set bit or bits in [F0: STOP BIT]... Input Decimal Point Position Number of digits of decimal places (setting of D register [D000]) can be set. Select and set among 0 to digits in [F0: INPUT DEC PT].. Settings Related to Alarm Output Set the following parameters when output- is specified for alarm output... Alarm Setpoints Set the alarm setpoints of alarm- and alarm- in [E0: SET POINT] and [E0: SET POINT] numerically. Setting range: A range of 0 to 00% of input range Setting resolution: 0.%.. Direction of Alarm Action Select the direction of alarm- action and that of alarm- action from among HIGH ALM (high-limit alarm) and LOW ALM (low-limit alarm) and set each in [E0: ALM ACTION] (direction of alarm- action) or [E0: ALM ACTION] (direction of alarm- action). To activate alarm status when input signal alarm setpoint, select HIGH ALM. To activate alarm status when input signal alarm setpoint, select LOW ALM. IM J0S0-0E th Edition Feb.0, 0-00

.. Hysteresis Set alarm- and alarm- hysteresis, in [E0: HYSTERESIS] and [E0: HYSTERESIS]. Hysteresis is a value added to the alarm setpoint in order for an alarm status to be released (to normal) after the alarm status has been activated. The alarm status will be released in the following conditions, depending on the direction of alarm action. * When HIGH ALM (high-limit alarm) is set: Alarm is released when input signal < (alarm setpoint - hysteresis). * When LOW ALM (low-limit alarm) is set: Alarm is released when input signal > (alarm setpoint hysteresis). Setting range: A range of 0 to 00% of input range Setting resolution: 0.%.. Alarm ON Delay and Alarm OFF Delay Set alarm- and alarm- ON delays in [E: ON DELAY] and [E: ON DELAY] and then alarm- and alarm- OFF delays in [E: OFF DELAY] and [E: OFF DELAY]. An alarm ON delay is a delay time from the establishment of alarm condition to alarm output; an alarm OFF delay is a delay time from the establishment of return-to-normal condition to output. Setting range: 0 to seconds Setting resolution: second (Note that about 0. second will be added to set time to prevent erroneous operation.) For example, when an alarm ON delay is set to second, alarm output is generated if alarm status continues for more than second after the input value exceeds the alarm setpoint. Further, when an alarm OFF delay is set to seconds, alarm output is released if normal condition continues for more than seconds after the input value has returned to normal from the alarm status... Direction of Relay Action Set the direction of relay energizing in alarm- normal condition and alarm- normal condition by selecting from among NRM DEENERGIZED (de-energized under normal condition) and NRM ENERGIZED (energized under normal condition) in [E: RL ACTION] and [E: RL ACTION] and set them.. DESCRIPTION OF ALARM ACTIONS This chapter describes examples of alarm actions under the following conditions. Item Alarm- Alarm- Parameter Setpoint Parameter Setpoint Direction of alarm E0: ALM ACTION High-limit E0: ALM ACTION Low-limit action alarm alarm Alarm setting E0: SET POINT 80% E0 : SET POINT % Hysteresis E0: HYSTERESIS 0% E0 : HYSTERESIS % Alarm ON delay E: ON DELAY sec. E : ON DELAY sec. Alarm OFF delay E: OFF DELAY sec. E : OFF DELAY sec. Description of alarm actions [%] 00 80 0 0 0 0 Alarm conditions sec. sec. Alarm- hysteresis (%) Alarm- action Alarm- action Alarm The alarm sounds if the condition where the input value is 80% or more of high-limit alarm continues for more than second. After the alarm sounds, when the condition where input value is less than 0%of the high-limit alarm continues for more than seconds, the status returns to normal High-limit alarm ON conditions [] [] High-limit alarm OFF Alarm- ON delay Alarm- OFF delay Alarm- setpoint (%) Alarm- setpoint (80%) Alarm- hysteresis (0%) The alarm sounds if the condition where the input value is % or less of low-limit alarm continues for more than seconds. After the alarm sounds, when the condition where input value is more than 0% of the low-limit alarm continues for more than seconds, the status returns to normal. []: Alarm status does not continue for more than second after the alarm conditions are at alarm-. []: status does not continue for more than seconds after the normal conditions are at alarm-. []: Alarm status does not continue for more than seconds after the alarm conditions are at alarm-. []: status does not continue for more than seconds after the normal conditions are at alarm-. Low-limit alarm ON Low-limit alarm OFF Alarm conditions conditions Alarm- Alarm- ON delay OFF delay [] sec. [] sec. Alarm Elapsed time sec.. LIST OF PARAMETERS Parameter Display Item MODEL Model TAG NO Tag no. SELF CHK Self-check result A DISPLAY Display * A0 INPUT Input value A0 OUTPUT Output value A0 OUTPUT Output value A ALM STATUS Alarm- status A ALM STATUS Alarm- status A STATUS Status * A REV NO Rev. no. A8 MENU REV MENU REV A0 SELF CHK Self-check result B DISPLAY Display * B0 INPUT Input value B0 OUTPUT Output value B0 OUTPUT Output value B ALM STATUS Alarm- status B ALM STATUS Alarm- status B0 SELF CHK Self-check result D SET (I/O) Setting (I/O) * D0 TAG NO. Tag no. D0 TAG NO. Tag no. D0 MENT Comment D0 MENT Comment D RESIST Total resistance D INPUT L_RNG Input low range D INPUT H_RNG Input high range D OUT L_RNG Output- low range * D OUT H_RNG Output- high range * D OUT L_RNG Output- low range * D OUT H_RNG Output- high range * D BURN OUT Burnout D0 OUT DR Direction of output- action D OUT DR Direction of output- action D S/W FILTER Software filter D NMRR Frequency setting * D0 SELF CHK Self-check result E SET(ALM) Setting (alarm output) * E0 SET POINT Alarm- setting (%) E0 SET POINT Alarm- setting (%) E0 ALM ACTION Direction of alarm- action E0 ALM ACTION Direction of alarm- action E0 HYSTERESIS Alarm- hysteresis (%) E0 HYSTERESIS Alarm- hysteresis (%) E ON DELAY Alarm- ON delay setting E ON DELAY Alarm- ON delay setting E OFF DELAY Alarm- OFF delay setting E OFF DELAY Alarm- OFF delay setting E RL ACTION Direction of alarm- relay action E RL ACTION Direction of alarm- relay action E0 SELF CHK Self-check result F SET() Setting (communication) * F0 PROTOCOL Communication protocol F0 ADDRESS Address F0 BAUD RATE Baud rate F0 PARITY Parity F0 DATA LEN Data Length F0 STOP BIT Stop bit F0 INPUT DEC PT Decimal point position of input F0 SELF CHK Self-check result P ADJUST Adjustment * P IN LOW RNG Input- low range setting P IN HIGH RNG Input- high range setting P0 OUTZERO ADJ Zero adjustment of output- P OUTSPAN ADJ Span adjustment of output- P OUTZERO ADJ Zero adjustment of output- P OUTSPAN ADJ Span adjustment of output- P0 SELF CHK Self-check result Q TEST Test * Q0 OUT TEST Forced output (output ) Q0 OUT TEST Forced output (output ) Q0 ALM TEST Forced output (alarm ) Q ALM TEST Forced output (alarm ) Q0 SELF CHK Self-check result * The Status is displayed for service personnel to see history records. * There are items not displayed depending on what output- is specified. * The parameters are the items to be set at the factory. IM J0S0-0E th Edition Feb.0, 0-00

8. MAINTENANCE The product starts running immediately when the power is turned on; however, it needs 0 to minutes of warm-up before it meets the specified performance. 8. Calibration Apparatus -dial decade resistance boxes units (YOKOGAWA 0 or equivalent) A digital multimeter (DMM) (YOKOGAWA or equivalent) A precision resistor of 0 Ω ±0.0%, W Setting tool for adjustment (Refer to ". Connector for Communication" in this manual.) 8. Calibration Procedure. Connect the instruments as shown below. First adjust the output- signal and then the output- signal. 00% 0% R R R Input -dial decade resistance box -dial decade resistance box R Power supply 0 8 L N GND 8 0 Output- R DMM Alarm- ALM DMM Alarm- ALM DMM Output- R DMM R: For current output using 0 Ω precision resistor. Operate the variable resistor according to the specifications (total resistance, 0%, 00% resistance) of the potentiometer to be connected. Keeping total resistance constant, change each value of R and R to apply the resistance equivalent to 0,, 0,, and 00% of the input range to the converter.. Check to see the corresponding output voltages are 0,, 0,, and 00% respectively and within the specified accuracy rating. ( R is used for current output.) For alarm output, check the relay action by the alarm indicator lamp or resistance of output terminals. Use the setting tool (VJ Parameter Setting Tool or JHT00 Handy Terminal) to adjust the input/output signals. User s Manual for VJ [Document No.: IM J0J-0E] User s Manual for JHT00 [Document No.: IM J0H0-0EN]. SAFETY AND EMC STANDARDS The following will be acquired. Safety: IEC/EN 00- compliance (CE), IEC/EN 00--00 compliance (CE) CAN/CSA C. No.00- compliance (CSA) UL00- (CSA NRTL/C) Installation category II Pollution degree Measurement category O (other) Rated measurement input voltage: ±0. V DC max. Rated transient overvoltage: 00 V (*) * This is a reference safety standard value for Measurement Category I of CSA/UL00- and Measurement Category O of EN 00--00. This value is not necessarily a guarantee of instrument performance. Entrance Cable IV Internal Wiring III T O Outlet Measurement Description category O (other) For measurements performed on circuits not directly connected to MAINS. II CAT.II For measurements performed on circuits directly connected to the low-voltage installation. III IV CAT.III For measurements performed in the building installation. CAT.IV For measurements performed at the source of the low-voltage installation. II Remarks Appliances, portable equipments, etc. Distribution board, circuit breaker, etc. Overhead wire, cable systems, etc. EMC standards: CE marking: EN - Class A, Table EN -- * The instrument continues to operate at a measurement accuracy of within ±0% of the range during testing. EN 0 Class A Group EN 000-- Class A EN 000-- EMC Regulatory Arrangement in Australia and New Zealand (RCM): EN 0 Class A, Group KC marking: Electromagnetic wave interference prevention standard, electromagnetic wave protection standard compliance Caution to comply with EMC standards: When operating this instrument by external power supply, use an independent power unit conforming to CEmarking. Be sure to use the lightning arrester to comply EMC standards. Note: When option code /C0 or /FB is specified, the conformity to the safety and EMC standards is excluded. 0. ENVIRONMENT STANDARD RoHS Directive: EN 08 (However, when option code /C0 or /FB is specified, CE marking is not applicable because the product does not comply with the Safety and EMC standards.). TRANSPORT AND STORAGE CONDITIONS Temperature: - to 0 C Temperature change rate: 0 C per hour or less Humidity: to %RH (no condensation) Keep this product in a conductive bag when plugged out, during transport or storage. This instrument is for Measurement Category O (other). Do not use it for measurements in locations falling under Measurement Categories II, III, and IV. IM J0S0-0E th Edition Feb.0, 0-00