CLS-1450 Series Spinner Flask Instruction Manual

Similar documents
3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

ASPIRE Laboratory Aspirator

Labconco Small Stoppering Chamber

Shaking Hot Tubs. Orbital / Reciprocating Shaking Water Bath Liter 115V S 28 Liter 115V Liter 230V

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Aluminum Heating Mantles

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

INSTALLATION INSTRUCTIONS. Cubix Widespread Faucet Part #: 3204, 5204, 3304, 5304 HANDLE STYLES

User s Manual and Operating Instructions

Corning Storage Bottles Selection and Use Guide

Corning Storage Bottles Selection and Use Guide

AUC Cell Washer. User Manual

Installation Instructions Model: EB Single-Lever Lavatory Faucet

PERFORM Operating Document

ProPet Washer. I-1020 Page 1 of 6 Rev. D /15/11

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-20B CompriCart

Winchester Heated Towel Rail. Fitting Instructions

FLASH PAK STERILIZATION CONTAINER SYSTEM

PORT700CF Portable Fume Collector

Installation and Maintenance "L" and "LS" Series

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

STERITITE INSTRUCTIONS FOR USE

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

7911A Constant Temperature Ice Bath. User s Manual

INSTRUCTION MANUAL. Instruction Manual High Throughput Homogenizer

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

Two Models Available!

Aspirator with trap flask FTA-1

Karbon Kitchen Sink Tap

5-Gallon Pail Mixer OWNERS MANUAL M-2000 SERIES MIXERS. Contents: Page: Safety, General & Receiving... 2 Operation... 3 Parts List...

This site is based on a but applies to all 1971-on Saab 99 and Saab 900.

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

INSTALLATION & OPERATING INSTRUCTIONS

QUICK PRIME INSTALLATION AND SERVICE MANUAL

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Immersion Cell (with Small Volume Vessel) User Guide Rev. C

20 High velocity Air

Gemini Satellite USER GUIDE. See brewer user guide for brewing instructions READ AND SAVE THESE INSTRUCTIONS. Style varies

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

P/N CC-100. Coolant Circulator. Operation manual

Installation & Operating Instructions

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

SYSTEMS for CATALYTIC FILTERS

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

Audi-Larm Audible Alarm

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Installation Instructions / Warranty

Murano Shower Cabin Installation Instruction

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

User s Manual and Operating Instructions

INSTALLATION INSTRUCTIONS. Uptown Contempo Widespread Faucets Part # s: 8880-****, 8881-****

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

Magnetic Stirring Systems with Heat

Operation Manual R205BV, R209BV

Troubleshooting the MPH 24FP Series Pedestal Hydrant

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

WALL MOUNTED ELECTRIC FIREPLACE HEATER. Model # : Onyx Ivory Mirror OWNER S MANUAL. AC V 60Hz 1500W

FORENSICS GLASS BLOCK MANIFOLD INNOVATION THROUGH CHEMISTRY

Econo-16 Models 2024EX, 2024STX 16oz. Popcorn Machine Instruction Manual

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-10 AseptiMini Pneumatic Portable Dental System

Industrial Vacuums, Inc

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

OSD10, OSD20 & OSD30 DRINK DISPENSER

Introduction. Table of Contents

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

Installation Instructions / Warranty. Metris 31060XX XX XX1

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

SECTION 1D ENGINE COOLING

Quick Start Guide LIQ-QSG-Hx438, Rev A June Rosemount Hx438. Amperometric Steam Sterilizable Dissolved Oxygen Sensors

INSTRUCTIONS FOR OPERATION AND CARE OF

CHILLER. Operator s & Installation Manual

RapidStill II MODEL INSTRUCTION MANUAL. Product designs are subject to change without notice REV. B / ECO A631

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

QUICK PRIME INSTALLATION AND SERVICE MANUAL

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Stainless Steel Pump to dispense portions up to 2oz MODELS INCLUDE:

USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES

VERTICAL GLANDLESS PUMP

ADVANTAGE SERIES KXRP33 AIR-TO-AIR HEAT EXCHANGER

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

Instruction Manual Hydraulic Crimping Tool

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

User s Manual and Operating Instructions

Rotary Evaporator Replacement Glassware

CL & CLG Clamp Mount Mixers

FTA-1 Aspirator with trap flask

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

Portable Induction Ranges

SECTION STEAM CONDENSATE PUMPS

High Output Vacuum/Pressure Pump

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

6. COOLING SYSTEM 6-0 COOLING SYSTEM MXU 500

EXC-450 User s Manual

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE

Transcription:

CLS-1450 Series Spinner Flask Instruction Manual Chemglass Life Sciences 3800 North Mill Road Vineland, NJ 08360 USA Phone: 800-843-1794 Email: customer-service@cglifesciences.com Web address: www.cglifesciences.com Rev. C 07/24/13

CLS-1450 Series Spinner Flask Instruction Manual Description: The Chemglass Life Sciences spinner systems are designed for long life, high efficiency and low maintenance. Spinners are the ideal environment for culturing a wide variety of cell cultures such as insect cells, hybridomas and many other suspension adapted cells. Features: Dimpled vessel 100mL up to 1L. 3L vessel has flat bottom. Heavy wall center port and side arms FDA approved materials Material Specifications: Spinner flasks are constructed of high quality components with the following specifications: Vessels: Shafts: Magnets: Paddle: Cap: Compression fitting: Liner: O-ring: Borosilicate type 1 glass Borosilicate glass 7mm PTFE encapsulated PTFE Polypropylene Polypropylene Silicone Silicone Material certifications: 21 CFR 177.1550 21 CFR 177.2600 TSE\BSE Declarations ASTM E-438, USP Type 1, Class A glass Material certifications are available upon request. Manual Symbols: The warning symbol indicates attention to an operation that could cause injury, equipment or process damage. 2

Operating and Assembly Instructions: The cap and paddle assemblies are shipped partially assembled. Glass Rod Installation (refer to Figure 1): Remove the magnet from the magnet holder by pushing the magnet through the holder until free. Next, remove the impeller blade by pulling it free of the magnet holder. Insert the glass rod (suspension shaft) into the hole in the bottom of the magnet holder. Insert the silicone plug and then replace the impeller blade and reinstall the magnet. Figure 1 WARNING: Be careful handling the glass shaft as accidental breakage can cause injury 3

Internal Cap Assembly (refer to Figures 2, 3, 4): Place the white silicone gasket in the inside of the center screw cap and thread the compression fitting body on to the cap stud. Next locate the impeller assembly and cap nut, and then insert the end of the glass shaft in the cap nut and slide the o- ring over the shaft. Next, loosely screw the cap nut with o-ring and glass shaft (with attached impeller assembly) to the compression fitting body. Do not fully hand tighten until the impeller assembly is adjusted to be about ¼ inch to ½ inch from the bottom of the flask, then fully hand tighten (see figures 3 & 4). Figure 2 Figure 3 CAP STUD From impeller to dimple ¼ to ½ Figure 4 With Impeller assembly attached (from Figure 1) From impeller to bottom ¼ to ½ WARNING: Be careful handling the glass shaft as accidental breakage can cause injury 4

100 & 250mL Spinners 500mL Spinner 5

1L Spinner 3L Spinner 6

Cleaning: Use a commercial cleanser approved for glass. Chemglass Life Sciences recommends item number CLS-4752, 7X and 7X-O-Matic cleaning solutions. Rinse all glassware as soon as possible after use. To decontaminate ware, autoclave contaminated items in water containing cleanser. Disassemble spinner assemblies, compression fittings and paddle assemblies for cleaning and to avoid the trapping of disinfectants and cleansers. Failure to do so may result in the release of these compounds during use with possible detrimental effects to cultures or assays. Thoroughly rinse items in tap water then distilled or deionized water - even the smallest products. Rigorously follow your rinsing protocol. Do not use glassware that is scratched, chipped or cracked for centrifugation, pressure, vacuum, heating or freezing. Breakage may result. Sterilizing: To prevent warping of the top cap and magnet holder, it is recommended that the flask be autoclaved in the standing position only. In large vessels, place a few ml of distilled water in the flask to generated additional steam in the vessel. Place approximately 20 ml of water (or PBS buffer) for each 10 liter of flask volume and autoclave @ 121C for 15 to 30 minutes. Make sure that the vessel is vented so that pressure or vacuum will not build up and cause vessel to explode or implode. Chemglass Life Sciences Warranty and Limitation of Liability Guarantee: Chemglass Life Sciences, herein known as CGLS, warrants the equipment to be free from all defects and guarantees acceptable performance assuming the equipment has been installed in accordance with the instructions provided by CGLS, and has been used for the specific design purpose, and has been maintained according to the maintenance instructions accompanying the equipment or other CGLS published documents. The warranty period is for one year from the date of sale. If the unit is determined to have a defect in materials or workmanship, then it will be repaired or replaced at no charge. NOTE: THE MAGNET HOLDER (P/N S: 1451-062, -063, -064, 1430-064) WILL WEAR OVER TIME AND SHOULD BE INSPECTED AND REPLACED PERIODICALLY 7

Return Authorization: CGLS must authorize any return of material. Please contact a customer service representative via the correspondence listed below to obtain a Return Merchandise Authorization (RMA) number. The purchaser is responsible for all packing and shipping to CGLS. If the equipment or material came in contact or was proximate to any biological organism, toxic or corrosive material, or any agent reasonably deemed to be potentially harmful, it must be cleaned and decontaminated prior to receipt by CGLS. The purchaser is obligated to disclose fully in writing, the cleaning and decontamination method. We reserve the right not to accept any unauthorized or potentially harmful shipment. Correspondence: Chemglass Life Sciences 3800 North Mill Rd. Vineland, NJ 08360 USA Phone: 800-843-1794 Email: customer-service@cglifesciences.com Web: www.cglifesciences.com 8