FLEXIBLE CORRUGATED TUBE

Similar documents
Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

SOLAR SYSTEM. We follow the sun.

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

10.85 VicFlex Sprinkler Fittings

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

Corrugated Coated Stainless Steel Hoses for gas use with European Standard EN 15266:2007

ADDITIONAL PRODUCTS 65

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

MIG-FLEX EXTENSIBLE, FLEXIBLE METAL HOSES

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

TECHNICAL DATA. Wet 26a. February 22, 2009

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Sprinkler Identification Number (SIN)

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

General System Layout Sketch

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

TRUST THE ORIGINAL. SUBMITTAL PACKAGE

Seung-Jin Ind.Co.,Ltd.

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description

Quick closing oil drain valve QDV

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Victaulic VicFlex Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85

SECTION FM-200 FIRE SUPPRESSION SYSTEM

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution

Smoke extraction duct of sheet steel

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Norminal Sprinkler Temperature Rating

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

I-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION

Victaulic Vic-Flex Sprinkler Fittings Series AH2 Braided Flexible Hose 10.85

Potable Piping System

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

- FLEXIBLE SPRINKLER HOSE FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING AND CLEAN ROOM CEILING -

Instructions for Installation, Operation, Care and Maintenance

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

DURA RIMP. Goodall Duracrimp coupling system: INFERNO ISO A and SUPER INFERNO. A safe crimping connection for our GOODALL steamhoses

esfr dry pendent sprinkler Vk501 (k14.0)

MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

SPRINKLER HEAD. Upright, Pendent & Recessed Pendent Sprinklers MODEL: SD1010, SD1015, SD1030, SD1032 DESCRIPTION TECHNICAL SPECIFICATION

Automatic Sprinklers

11.2K * Pendent Extended Coverage, Light and Ordinary Hazard General Description. Model/Sprinkler Identification Numbers (SINs) Technical Data

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

Sprinkler Identification Numbers

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

General System Layout Sketch

THERMODYNAMIC STEAM TRAP

CAP SERIES SEWAGE AND WASTE WATER PUMPS

FAN ENGINEERING. Sealing of Fan Housings

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Model/Sprinkler Identification Number (SIN) Technical Data

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting

esfr dry pendent sprinkler Vk502 (k14.0)

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Automatic Sprinklers

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Numbers

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

The intelligent alternative for flue gas venting systems

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Transcription:

Back To The Natur e S O L A R S Y S T E M SPRINKLER SYSTEM B O I L E R FLEXIBLE CORRUGATED TUBE INSULATED SOLAR HOSES S Y S T E M w w w. k a s. c o m. t r

SOLAR SYSTEM

System Definition of Corrugated Flexible Hoses in Solar Industry In recognition of transfer of solar energy via metalic flexible hoses, day by day, corrugated flexible hoses have been becoming one of the alternative ways for the users in the World. As indicated in the successful results, corrugated flexible hoses have turned into a main formula in the solar industry. Stainless Steel with the quality AISI 316L operated in heat tranfers supplies many advantages. Quick Coupling System enables easier connection among the parts; whereby, the items are locked without any welding procedure or any other union parts and the system enables tightness between the metalic parts; in this regard, Quick Coupling System, developed in KAS laboratory by Research & Development Department, has become the solution in many countries in the world, especially in Europe Advantages; The heat rate is high and the system reacts faster ( m2/m) The helistic pitch prevents lime and corrosion High Water-Carrying Capacity Easy installation due to its lightness 4

Technical Specifications of KAS Flexible Stainless Steel Solar Flex DN Outer Diameter (D2) mm Internal Diameter (D1) mm Material Thickness (t) mm Material Weight ( % =) (gr / m) Surface ( %5 ± ) (m2 / m) Volume ( %5 ± ) (dm3 / m) Corrugation per 0 mm Bend Radius (Static) r min (mm) Working Pressure 20 C (bar) Nominal Pressure DIN EN ISO 380 (Pn) Code D2 t D1 16 Ø 21,3 ± 0,2 Ø 16,2 ± 0,2 0,18 AISI 31 6 L 142 0,0949 0,2728 22 25 16 16 04.16.316 20 Ø 26,4 ± 0,2 Ø 20,9 ± 0,2 0,18 AISI 31 6 L 185 0,1446 0,4271 21 30 04.20.316 25 Ø 31,2 ± 0,4 Ø 25,3 ± 0,3 0,2 AISI 31 6 L 245 0,1586 0,6335 19 35 04.25.316 FLEXIBLE ELASTOMERIC FOAM Temperature range Thermal coductivity λ W/ ( m K ) - 50 C to + 150 C 20 C 0,0040 W (m.k) 40 C 0,0042 W (m.k) 60 C 0,0045 W (m.k) 5

FLEXIBLE PRESSURE LOSS CHART 6

QUICK COUPLING SYSTEM CODE FLEX DN OUTER THREADED 60.16.012 DN 16 1/2 60.16.016 DN 16 3/4 60.16.025 DN 16 1 CODE FLEX DN OUTER THREADED 60.20.012 DN 20 1/2 60.20.016 60.20.025 DN 20 DN 20 3/4 1 CODE FLEX D CODE FLEX DN OUTER THREADED 60.25.012 DN 25 1/2 60.25.016 DN 25 3/4 60.25.025 DN 25 1 7

ASSEMBLY INSRTUCTIONS 1 2 3 Cutting the hose with a cutter T Piece Assembly of T piece with two tools. 4 5 R DED Quick Coupling Union Parts Assembly of Quick Coupling Union with two tools Correct Assembly False Assembly Bend Radius Min. Bend Radius (mm) DN 16 DN 20 DN 25 20 25 30 8

ASSEMBLY INSRTUCTIONS Before Assembly After Assembly CODE ITEM PIECE MATERIAL 8 Easy and Slippery Surface 1 7 Canal 1 CW614N 6 Nipple 1 316L 5 Corrugated Flexible Hose 1 NBR 4 Nipple Gasket Seat 1 MS63 Brass 3 Metal Gasket 1 CW614N 2 Nut 1 CW614N 1 Gasket 1 NBR 9

SOLAR FITTING GROUP CODE NAME SIZE 54.01.SP 8300-SP 251-S 252-S Brass Nut Brass Nut Brass Nut Brass Nut DN 12 DN 16 DN 20 DN 25 CODE NAME SIZE 8017 88 8112 8114 Klingerit Gasget Klingerit Gasget Klingerit Gasget Klingerit Gasget DN 12 DN 16 DN 20 DN 25 CODE NAME SIZE T-519 T-520 T-521 T-522 S. Steel Ring S. Steel Ring S. Steel Ring S. Steel Ring DN 12 DN 16 DN 20 DN 25 CODE NAME SIZE 02.02.201 02.02.202 02.02.203 Brass Nipple M/M Brass Nipple M/M Brass Nipple M/M 1/2 3/4 1 CODE NAME SIZE 19.01.914 19.01.915 19.01.916 Nipple With Ring And Nut Nipple With Ring And Nut Nipple With Ring And Nut 1/2 3/4 1 CODE NAME SIZE 46.70.000 46.70.012 46.70.016 46.70.020 Hammer Hammer Die Hammer Die Hammer Die -- 12 16 20

BOILER SYSTEM

KAS BOILER FLEX The corrugated flexible hoses applied with Stainless Steel AISI 316L for solar tanks and boiler systems transfer the heat in manifolds to tanks and boilers in order to heat the water in the tank. In this appliance, there is a heater tank fixed into the manifolds or a vertical single heater. Corrugated flexible hoses manufactured according to size of the tanks and its volume can be also fixed with seperated fittings. KAS Result & Development Departmant can also design new style fittings according to needs of the partners. Advantages; By the help of the pitch on Stainless Steel Corrugated Hoses, the system is more productive than the rigid conduit systems. The rate of heat is more productive and faster. Because of being lighter and being flexible, the system enables easy-fixing method. AISI 316L is convient for potable water. This system prevents Structural defect of the dilatation while transfering hot & cold water and enables high protection and resistance against lime and corrosion Stainles Steel AISI 316L material is suitable for drinking water. 12

TECHNICAL SPECIFICATIONS OF KAS FLEXIBLE STAINLESS STEEL BOILER FLEX DN Outer Diameter (D2) mm Internal Diameter (D1) mm Material Thickness (t) mm Material Weight ( % =) (gr / m) Surface ( %5 ± ) (m2 / m) Volume ( %5 ± ) (dm3 / m) Corrugation per 0 mm Bend Radius (Static) r min (mm) Working Pressure 20 C (bar) Nominal Pressure DIN EN ISO 380 (Pn) Code D2 t D1 16 Ø 21,3 ± 0,2 Ø 16,2 ± 0,2 0,18 AISI 31 6 L 142 0,0949 0,2728 22 25 16 16 04.16.316 20 Ø 26,4 ± 0,2 Ø 20,9 ± 0,2 0,18 AISI 31 6 L 185 0,1446 0,4271 21 30 04.20.316 25 Ø 31,2 ± 0,4 Ø 25,3 ± 0,3 0,2 AISI 31 6 L 245 0,1586 0,6335 19 35 04.25.316 32 Ø 40.6 Ø 33.4 0.25 AISI 31 6 L 400 0.0947 0.2732 22 50 16 16 01.32.316 40 Ø 49.8 Ø 39.8 0.25 AISI 31 6 L 7 0.1446 0.4271 21 60 01.40.316 50 Ø 60.8 Ø 50.5 0.25 AISI 31 6 L 850 0.1444 0.4264 21 70 01.50.316 13

RP R OD OD TECHNICAL INFORMATION FOR KAS BOILER FLEXIBLE HOSES Tecnical Data DN Inner Threaded (Rp ) Outer Threaded (R ) ØD 16 3/8 * 3/8 1/2 * 1/2 21.3 20 1/2 * 1/2 3/4 * 3/4 26.9 25 3/4 * 3/4 1 * 1 33.7 32 40 50 1 * 1 1 1/4 * 1 1/4 1 1/4 * 1 1/4 1 1/2 * 1 1/2 1 1/2 * 1 1/2 2 * 2 2 * 2-42.4 48.3 60.3 70 1 2 1 2 L1 L1 L L Material 1 Fittings Stainless Steel AISI 316 2 Hose Stainless Steel AISI 316 L 14

INSULATED SOLAR HOSES

KAS INSULATED FLEX Kas Solar Flex Single Tube Without Cable UV Cover DIAMETER SIZE DESCRIPTION THICKNESS DN 16 13x22 mm Solar Flex Single 13 DN 20 13x28 mm Solar Flex Single 13 Kas Solar Flex Double Tube Without Cable UV Cover DIAMETER SIZE DESCRIPTION THICKNESS DN 16 13x22 mm Solar Flex Double 13 DN 20 13x28 mm Solar Flex Double 13 Kas Solar Flex Single Tube With Cable UV Cover DIAMETER SIZE DESCRIPTION THICKNESS DN 16 13x22 mm Solar Flex Single 13 DN 20 13x28 mm Solar Flex Single 13 Kas Solar Flex Double Tube With Cable UV Cover DIAMETER SIZE DESCRIPTION THICKNESS DN 16 13x22 mm Solar Flex Double 13 DN 20 13x28 mm Solar Flex Double 13 16

TECHNICAL DATA SHEET PROPERTY TECHNICAL DATA TEST METHOD LAB / TEST REPORTS Thermal conductivity (A) 0 C - 0.035W/mK C - 0.036W/mK EN 12667 20 C - 0.037W/mK EN ISO 8497 40 C - 0,040W/mK DEMOKRITOS Permeability ( j) > 7000 EN 13469, EN 12086. RTU / BDA KEUR Density (p) 50-65 Kgr/rrr EN 13470 & EN 1602 Tensile strength (Pa) >0.15 Mpa EN ISO 1798 Tensile strength (Pa) of UV Film >0. Mpa ASTM D 882 Elogation at break > 150% EN ISO 1798 Elogation at break of UV Film > 200% Operating temperatures ( C) Pıpes. Slit & Seal: -40 C to +5 C EN 14706. EN 14707 Solar Film -80 C i'toc, -80 C Fire rating B-s3, do Class 0, Class 1 DİN 42-1 or EN 13501-1 Prüfinstitut Hoch Diameter tolerance Pipes, Slit & Seal: PrEN 13467 06-042: +1mm to +3mm Thickness Pipes: 6mm, 9mm,13mm: ±1% PrEN 13467 19mm: ±2% 25mm,30mm: ±2% Slit & Seal: PrEN 13467 19mm: ±1,5mm 25mm: ±2mm Overlap Slit & Seal: DİN 53370 120 jm: ±15 UV Film: < 0,15mm DİN 53370 Oil & Grease resistance Very good ASTM D 471 UV resistance Excellent ASTM D 518 VVeather resistance Excellent ASTM D 518 Noise reduction Up to 30dB DİN 49 Dimensional stability 1.5-3% PrEN 14304. EN 1604 Colour of UV Film Black CFC, HFC, HCFC Free Odor Neutral Adhesion for Slit & Seal Overlap: 6 N/cm NF EN 1464 ISO 4578 IOP 041 Self adhesive stripe FINAT NO 9-IOP 043 6 N/cm Static temperature resistance 0 C continuous Slit & Sealv The written figures are these that have been measured in our laboratory, under typical conditions. They can be modified vvithout prior notice. You are kindly requested to assert their validity before any special usage. 17

SPRINKLER HOSE WITH BRAIDING AND CONNECTION ADAPTER

GENERAL EXPLANATIONS KAS sprinkler hose and connection kit can be safely used in fire extinguishing systems due to its structure not being affected by seismic motions and the braided hose s resistance to heat and pressure. Primary advantages are connecting the sprinkler to the fire line with minimum effort and installing the device easily into ceiling with its connection kit. Public places like shopping centers, hotels, theaters, cinemas where the response time is really important are where the system is mostly chosen. There are many advantages using KAS Sprinkler Hose and Connection Adapter to mount sprinkler systems. Most important ones are minimum workmanship time provided by easy installation, safer sprinkler systems against seismic motions and adjustability without being dependent upon design of installation lines. Proficiency and time is needed for adjusting the steel installation line to the desired sprinkler mounting point using elbows, couplings etc. By using KAS Sprinkler Adapter, it is quite easy to align and tighten sprink side of sprinkler hose with desired point (usually middle point of grid) of ceilings. Additionally, due to convenient design of hose fixing apparatus, sprink side of hose can be adjusted on vertical axis. As a result, height of sprinkler head and escutcheon can be adjusted relative to ceilings. 20

GENERAL SPECIFICATIONS Dimensions and Operating Conditions Hose Diameter DN 20-3/4 DN 25-1 Connection Diameter Nipple Side 1 / Sprink Side 1/2 Standard Length Operating Pressure 600-900 - 1200-1500 - 1800 mm 20 bar / 290 psi Ambient Temperature Rating 149 C / 300 F Minimum Bending Radius 70 mm 0 mm Largest K-Factor Wet Dry Systems Connection to Fire Sprinkler 8.0 GPM/psi½ Both Direct Material Specifications Hose Braiding Wire Connections Connection Adapter AISI 316L Stainless Steel AISI 304 Stainless Steel Carbon Steel (Standard) / Stainless Steel (Optional) Carbon Steel (Zinc Coated) Friction Losses and Specifications (UL Listed) Model No Hose Length Input Diameter Output Diameter Max. No of 90 Bends Equivalent Length of 1 Sch 40 Pipe Maximum Pressure A-SP600-20 0.6m 2ft 1 inch 1/2 inch 2 40 20 bar/290 psi A-SP900-20 0.9m 3ft 1 inch 1/2 inch 3 60 20 bar/290 psi A-SP1200-20 1.2m 4ft 1 inch 1/2 inch 3 71 20 bar/290 psi A-SP1500-20 1.5m 5ft 1 inch 1/2 inch 3 87 20 bar/290 psi A-SP1800-20 1.8m 6ft 1 inch 1/2 inch 3 7 20 bar/290 psi 21

TECHNICAL DRAWINGS Kit Fixing Apparatus (Lay-in) Kit Fixing Apparatus (Clip-in) Hose Fixing Apparatus Kit Suspension Profile DN20 Hose Technical Drawing DN25 Hose Technical Drawing 22

INSTALLATION INSTRUCTIONS 1 2 3 The hose is attached and tightened to the mechanical-t, tee or vvelded vvrench. On this process, because the thread of nut is conical (NPT, BSPT), no gasket is required. You may need to consult NFPA sealant during this process. are attached to the approximate middle of metal grid by rule of thumb and tightened using a SVV- vvrench not to be fully tight. İt is recommended not to complete may be required. At this phase, the bolts upper parts of tightened. direction at the same plane. has equal lengths stuck at both sides. 4 5 6 The upper bolts of right and left kit apparatuses are tightened using a SW- vvrench. İt is recommended to do this by a torque-limited vvrench at 2 pound-foot (2.7 N.m) torque. Sprink side of the sprinkler hose is apparatus is adjusted to be aligned vvith the hole on ceiling. The bolt of the apparatus is tightened using SVV-19 vvrench. İt is recommended to do this by a torque-limited vvrench at 5 pound-foot (6.8 N.m) torgue. The vvhole set is aligned so that the sprink side of hose is aligned vvith the hole on ceiling. The bottom bolts of right and left kit a SVV- vvrench. İt is recommended to do this by a torque-limited vvrench at 2 pound-foot (2.7 N.m) torgue. 7 8 9 The sprinkler head and escutcheon are tightened to sprink end of hose according to NFPA and sprinkler head manufacturer's guidelines. Thread type of sprinkler head and hose is conical (NPT), so, no gasket is required. You may need to consult NFPA sealant during this process. apparatus and adjust the level of sprink side of sprinkler hose relative to ceiling structure as desired. Finally tighten the bolt using a SW-19 vvrench. İt is recommended to do this by a torque-limited vvrench at 5 pound-foot (6.8 N.m) torgue. Test the installation of sprinkler system against leaks per NFPA. Finally, sprinkler hose and connection adapter is ready to help protecting living beings Resistance of our product against pressure, temperature, vibration and corrosion is tested in UL Laboratories, USA. 23

Back To The Natur e >>